• 제목/요약/키워드: 상시진동 실험

Search Result 41, Processing Time 0.022 seconds

Free and Ambient Vibration of Steel-Deck Truss Bridge (강합성 데크 트러스 보도교의 자유진동해석 및 상시진동실험에 관한 연구)

  • Jung, Sung Yeop;Oh, Soon Taek
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.4
    • /
    • pp.60-68
    • /
    • 2012
  • This study describes an analytical and experimental investigation of the pedestrian steel-deck truss bridge in the City of Rochester, New York, U.S.A. This investigation was undertaken to provide assurance that this important bridge continues to be functional for this use. An ambient vibration experiment on full-scale structures is a way of assessing the reliability of the various assumptions employed in the mathematical models used in analysis. It is also the most reliable way of determining the structural parameters of major importance in structural dynamics, such as the mode shapes and the associated natural frequencies. Pedestrian-induced vibrations have been measured on the bridge to determine the displacement and the vertical and transverse dynamic characteristics of the steel deck truss. In the analytical modeling, three-dimensional finite element analysis was developed and validated against the ambient tests.

Dynamic Response Analysis of Caisson-Type Breakwater Using Wave-Induced Ambient Vibration (파랑유발 상시진동을 이용한 케이슨 방파제 구조물의 진동응답분석)

  • Lee, So-Young;Yi, Jin-Hak;Nguyen, Khac-Duy;Lee, Po-Young;Kim, Jeong-Tae
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2011.04a
    • /
    • pp.606-609
    • /
    • 2011
  • 본 연구에서는 실제 케이슨 방파제 구조물의 진동기반 안정성 평가를 위한 기초연구로서, 현장실험을 통해 케이슨 방파제 구조물의 진동응답을 분석하였다. 이를 위해 첫째, 대상구조물로서 부산항 오륙도 케이슨 방파제를 선정하였다. 둘째, 파랑에 의한 상시진동 가속도응답을 계측하였다. 마지막으로, 계측된 가속도신호로부터 파워스펙트럼밀도함수, 고유진동수 및 모드강성도 분석을 통해 케이슨 방파제의 진동특성을 분석하였다.

  • PDF

Natural Frequency of Tall Building Through Ambient Vibration Measurement (고층건물의 상시진동계측을 통한 고유진동수)

  • Yoon, Sung Won;Ju, Young Kyu
    • Journal of Korean Society of Steel Construction
    • /
    • v.15 no.2
    • /
    • pp.117-124
    • /
    • 2003
  • Wind-induced motions, like acceleration for instance, often influence designs for high-rise buildings. As a consequence, correct assessment of natural frequency becomes important. The empirical expressions used to quantify this parameter at the design phase tend to yield values that are significantly different from each other. This paper is concerned with the natural periods of steel buildings. It describes the vibration measurement methods that were employed for testing buildings. This paper will also present reliable methods of assessing the natural period from ambient vibration tests. Data from measurements on 21 buildings in Seoul were provided while 21 buildings were tested by ambient vibration measurements to obtain the natural periods. While regression formulas of natural periods for steel-frarried tall buildings were suggested,the obtained formula was compared with the empirical expressions of structural standards and the Eigen-value analysis.

A Study on the Efficient Tension Estimation of Cables under Ambient Vibration using Minimized Measurement and Signal Processing System (최소화된 계측 및 신호 처리 시스템을 이용한 상시진동 케이블의 효율적인 장력 추정에 관한 연구)

  • Lee, Hyeong-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.11
    • /
    • pp.594-603
    • /
    • 2018
  • Recently, according to the development of measurement techniques, it has become possible to take complicated and time-consuming field measurements in a simple and convenient manner. In this background, this study estimated the tension of cables under ambient vibration using minimized measurement and signal processing. The VBDM using video-only by low-cost equipment was used as a minimized measurement. An estimation of the natural frequency using the mirror frequency concept was also proposed to solve the shortage of frequency band in this case. Furthermore, the FDD method was adopted for a natural frequency estimation in the ambient vibration related to field application. Experimental studies using a cable-stayed bridge model were carried out to examine the properties of the mirror frequency and the applicability of FDD with the proposed minimized system. The results showed that FDD for ambient vibration also works properly in an estimation of the natural frequency using the minimized system. In addition, the mirror frequency concept can allow a high natural frequency estimation even in a distorted signal by low-speed recording, which can overcome the limit of the minimized system. Overall, the proposed minimized system can be effective for the tension estimations of a cable under ambient vibration.

Evaluation of Short and Long-Term Modal Parameters of a Cable-Stayed Bridge Based on Operational Modal Analysis (운용모드해석에 기반한 사장교의 장단기 동특성 평가)

  • Park, Jong-Chil
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.4
    • /
    • pp.20-29
    • /
    • 2022
  • The operational modal analysis (OMA) technique, which extracts the modal parameters of a structural system using ambient vibrations, has been actively developed as a field of structural health monitoring of cable-supported bridges. In this paper, the short and long-term modal parameters of a cable-stayed bridge were evaluated using the acceleration data obtained from the two ambient vibration tests (AVTs) and three years of continuous measurements. A total of 27 vertical modes and 1 lateral mode in the range 0.1 ~ 2.5 Hz were extracted from the high-resolution AVTs which were conducted in the 6th and 19th years after its completion. Existing OMA methods such as Peak-Picking (PP), Eigensystem Realization Algorithm with Data Correlation (ERADC), Frequency Domain Decomposition (FDD) and Time Domain Decomposition (TDD) were applied for modal parameters extraction, and it was confirmed that there was no significant difference between the applied methods. From the correlation analysis between long-term natural frequencies and environmental factors, it was confirmed that temperature change is the dominant factor influencing natural frequency fluctuations. It was revealed that the decreased natural frequencies of the bridge were not due to changes in structural performance and integrity, but to the environmental effects caused by the temperature difference between the two AVTs. In addition, when the TDD technique is applied, the accuracy of extracted mode shapes is improved by adding a proposed algorithm that normalizes the sequence so that the autocorrelations at zero lag equal 1.

Estimation of Dynamic Characteristics of Existing Dam Floodgate Using Ambient Vibration (상시 진동을 이용한 댐 수문의 동특성 추정)

  • Kim, Nam-Gyu;Lee, Jong-Jae;Bea, Jung-Ju
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.31 no.4
    • /
    • pp.343-350
    • /
    • 2011
  • Recently, as the catastrophic disasters due to earthquake happen frequently all over the world, it draws lots of attention to seismic capacity evaluation and/or structural integrity assessment of deteriorated civil infra-structures. However, there have been few studies on the existing dam flood gates, expecially in Korea. In this study, a proper vibration testing method applicable to a dam flood gate has been suggested, since the dynamic characteristics of a darn flood gate can be fundamental data for seismic capacity evaluation or structural integrity assessment. The frequency domain decomposition technique has been incorporated for modal parameter identification. Two kinds of vibration tests using an impact hammer and ambient vibration sources were carried out on two types of dam floodgates with different shapes. Through the field tests, the effectiveness of the ambient vibration tests were verified.

Forced Vibration Testing of a Four-Story Reinforced Concrete Frame Building (철근콘크리트조 4층 골조건물의 강제진동실험)

  • Yu, Eun-Jong;Wallace, John W.
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.11 no.2 s.54
    • /
    • pp.27-38
    • /
    • 2007
  • A series of forced vibration tests and ambient vibration measurement was conducted on a four-story reinforced concrete building damaged in the 1994 Northridge earthquake. Both low amplitude broadband and moderate amplitude harmonic excitation were applied using a linear shaker and two eccentric mass shakers, respectively, and ambient vibrations were measured before and after each forced vibration test. Accelerations, interstory displacements, and curvature distributions were monitored using accelerometers, LVDTs and concrete strain gauges. Natural frequencies and the associated mode shapes fur the first 7 modes were identified. Fundamental frequencies determined from the eccentric mass shaker tests were 70% to 75% of the values determined using ambient vibration data, and 92% to 93% of the values determined using the linear shaker test data. Larger frequency drops were observed in the NS direction of the building, apparently due to damage that was induced during the Northridge earthquake.

Damage Estimation of Bridge Using Vibration Data Caused by Ordinary Traffic Loadings (교통하중에 의한 상시진동기록을 이용한 교량의 손상추정기법)

  • 윤정방;이진학;이종원;김재동;정환욱
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.14 no.1
    • /
    • pp.77-85
    • /
    • 2001
  • 본 연구에서는 차량하중에 의한 상시진동기록을 이용한 교량의 손상추정기법을 연구하였다. 즉, 차량진행 중 측정된 신호로부터 구조물의 모드특성을 구하고, 이를 이용하여 손상위치 및 손상정도를 추정하는 알고리즘을 제안하였다. 제안기법의 검증을 위하여 차량하중을 재하할 수 있는 모형교량을 제작하여 손상실험을 수행하였다. 차량진행 중 교량의 수직가속도를 계측하였으며, 측정된 가속도시계열로부터 random decrement(RD) 기법을 사용하여 자유진동신호를 구한 후, 이로부터 구조물의 모드특성을 추정하였다. 추정된 모드특성을 기초로 신경망기법을 적용하여 손상위치 및 손상정도를 추정하였으며, 추정된 결과는 실제 손상과 비교적 잘 일치하였다.

  • PDF

A Basic Experimental Study on Vibration Power Generation Using Bridge Vibration (교량의 진동을 이용한 진동력 발전 기초실험연구)

  • Jo, Byung-Wan;Lee, Yun-Sung;Kim, Yung-Ji;Yoon, Kwang-Won
    • International Journal of Highway Engineering
    • /
    • v.12 no.4
    • /
    • pp.121-129
    • /
    • 2010
  • Through this paper, we studied on the basic concept of vibration-induced power generation for urban infrastructures. Since the travelling of automobiles on the bridge cause vibration, it is possible to convert the vibration energy into green-electric energy by utilizing magnetic induction technology. In this paper we define the concept of green-bridge vibration power generation system which contains the concept of magnetic induction technology and propose a vibration power generation device for converting the bridge vibration energy into the electric energy. Also, an experiment was held by applying the vibration power generator on a real bridge. The results showed the applicability and effectiveness of the vibration power generator.

Modal Parameter Extraction of Seohae Cable-stayed Bridge : II. Natural Frequency and Damping Ratio (서해대교 사장교의 동특성 추출 : II. 고유진동수와 감쇠비)

  • Kim, Byeong Hwa;Park, Jong-Chil
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.5A
    • /
    • pp.641-647
    • /
    • 2008
  • This paper introduces a new technique that can extract natural frequencies and damping ratios from output-only vibration data. Firstly, the free vibration data is obtained from the cross correlations of the output-only response data using a singular value decomposition process. Secondly, the well-known system identification algorithm is applied to extract the natural frequencies and damping ratios from the extracted free vibration data. Comparing to ERADC technique, the accuracy of the proposed modal parameter identification algorithm has been numerically examined. Furthermore, the practicability of the proposed algorithm has been examined through the output-only acceleration data collected from the Seohae cable-stayed bridge. Using the proposed technique, total 24 modes have been identified for the deck plate motions of the bridge.