• Title/Summary/Keyword: 상승 및 하강시간

Search Result 100, Processing Time 0.034 seconds

Analysis of Loop-Rating Curve in a Gravel and Rock-bed Mountain Stream (자갈 및 암반 하상 산지하천의 고리형 수위-유량 관계 분석)

  • Kim, Dong-Su;Yang, Sung-Kee;Yu, Kwon-Kyu
    • Journal of Korea Water Resources Association
    • /
    • v.45 no.9
    • /
    • pp.853-860
    • /
    • 2012
  • It is well-known that loop effect of the stage-discharge relationship is formulated based on many field observations especially for the sand rivers. Theoretical understandings of the loop effect for the sand rivers have been widely provided, based on the facts that it is driven by the flood wave propagation and bed form changes over the given flood period. However, very few theoretical studies or field observations associated with loop-rating curves in the gravel or rock-bed mountain streams have been attempted so far, due particularly to the difficulties in the accurate discharge measurement during the flood in such field conditions. The present paper aims to report a unique loop-rating curve measured at a gravel and rock-bed mountain stream based on the flood discharge observation acquired during the typhoon, Muifa that passed nearby Jeju Island in summer of 2011. As velocity instrumentation, a non-intrusive Surface Velocity Doppler Radar to be suitable for the flood discharge measurement was utilized, and discharges were consecutively measured for every hour. Interestingly, the authors found that the hysteresis of the loop-rating curve was adverse compared to the typical trend of the sand bed streams, which means that the discharge of the rising limb is smaller than the falling limb at the same stage. We carefully speculate that the adverse trend of the loop-rating curve in the gravel bed was caused by the bed resistance change that works differently from the sand bed case.

A study on the performance evaluation and technical development of an eco-environmental photovoltaic solar leisure boat with applied sail control device (접이식 풍력 Sail 돛 제어장치를 적용한 친환경 태양광 레져보트의 성능평가)

  • Moon, Byung-Young;Lee, Sung-Bum;Lee, Ki-Yeol
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.3
    • /
    • pp.240-248
    • /
    • 2016
  • As a new technical approach, the achievement of an eco-environmental leisure boat with a photovoltaic system is attempted by simultaneously actuating nine photovoltaic solar panels, in association with an applied sail control system by use of wind. In this approach, the photovoltaic system consists of a solar module, an inverter, a battery, and relevant components, while the sail control device is equipped with a sail up/down and mast-turning instrument. Furthermore, this research conducts a performance evaluation of the manufactured prototype and acquires the purposed quantity value and the development purpose items. The significant items-sail up/down speed (seconds) and mast turning angle (degrees)-are evaluated during the performance test. In the process of the performance evaluation, a wind direction sensitivity of 90% and a maximum instant charging power of 900 W were also obtained. In addition, the maximum sail time is evaluated in order to acquire the optimum quantity.

The Effect of Interannual Variations in Water Temperature on the Yellowtail Catch, Seriola Quinqueradiata, in the Eastern Part of the Korean Peninsula (동해 연근해 수온의 경년변화가 방어 어획량에 미치는 영향)

  • Kim, Sang-Woo;Ahn, Ji-Suk;Lee, Yoon
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.23 no.7
    • /
    • pp.909-917
    • /
    • 2017
  • In this study, we investigated the relationship between catches of yellowtail and water temperature at the set net fisheries of Gyeongsangbuk-do (Gyeongbuk) and Gangwon-do (Gangwon) off the east coast of Korea from May-November, 1980-2010. We also analyzed the water temperature and fluctuation of catches during the northward moving period (May-August) and southward moving period (September-November) using NOAA satellite images. Although the total catches fluctuated year by year, catches increased during the southward moving period when the water alongside the coast warmed. Yellowtail catches during the southward period in fall were higher than those during the northward period in spring or summer. The catch when the water temperature decreased was larger in Gyeongbuk than in Gangwon for all periods However, the catch when the water temperature increased was much larger in Gangwon than in Gyeongbuk. This indicates that high summer temperatures (> $25^{\circ}C$) affected the coast of Gangwon, with high water temperature ($20^{\circ}C$) maintained in the region during fall. Therefore, the increased catch in Gangwon was due to longer yellowtail presence caused by increased water temperature.

Physiological and Biochemical Response of Blood on Low Temperature Stress in Sevenband Grouper, Epinephelus septemfasciatus (저수온 스트레스에 따른 능성어 (Epinephelus septemfasciatus) 혈액의 생리생화학적 반응)

  • Park, Jong Youn;Park, Jae Min;Hong, Chang Gi;Kim, Kyong Min;Cho, Jae Kwon
    • Korean Journal of Ichthyology
    • /
    • v.28 no.1
    • /
    • pp.1-8
    • /
    • 2016
  • This study was conducted to investigate the physiological responses of sevenband grouper, Epinephelus septemfasciatus at low temperature condition in winter season. Water temperature was dropped from $12^{\circ}C$ to $5^{\circ}C$ by two different interval (interval I: $-1^{\circ}C/24h$ and interval II: $-1^{\circ}C/8h$). The experimental fishes were exposed for 9 days at each water temperature condition, and were observed survival rate. The blood sample was collected from fishes for analysis of cortisol, glucose, total protein (TP), and electrolytes ($Na^+$, $Cl^-$, $K^+$). Mortality of fish was not observed until $5^{\circ}C$. The mortality (12 individuals) began after 170 h and all fish were death after 174 h in interval I case, whereas the mortality (9 individuals) began after 72 h and all fish were death after 76 h in interval II case. Little different was observed in the physiological responses, but trend was similar between two intervals. The physiological metabolism of plasma cortisol and glucose were increased rapidly, and swimming ability and respiration response was faster at $7^{\circ}C$. This result means that the critical temperature of sevenband grouper was $7^{\circ}C$ at low water temperature condition.

Design of Enhanced IEEE 1500 Wrapper Cell and Interface Logic For Transition Delay Fault Test (천이 지연 고장 테스트를 위한 개선된 IEEE 1500 래퍼 셀 및 인터페이스 회로 설계)

  • Kim, Ki-Tae;Yi, Hyun-Bean;Kim, Jin-Kyu;Park, Sung-Ju
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.44 no.11
    • /
    • pp.109-118
    • /
    • 2007
  • As the integration density and the operating speed of System on Chips (SoCs) become increasingly high, it is crucial to test delay defects on the SoCs. This paper introduces an enhanced IEEE 1500 wrapper cell architecture and IEEE 1149.1 TAP controller for the wrapper interface logic, and proposes a transition delay fault test method. The method proposed can detect slow-to-rise and slow-to-fall faults sequentially with low area overhead and short test time. and simultaneously test IEEE 1500 wrapped cores operating at different core clocks.

The Fabrication and Evaluation of HgI2 Semiconductor Detector as High Energy X-ray Dosimeter Application (고에너지 X선 선량계 적용을 위한 TiO2 첨가된 요오드화수은 반도체 검출기 제작 및 평가)

  • Choi, Il Hong;Noh, Sung Jin;Park, Jung Eun;Park, Ji Koon;Kang, Sang Sik
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.7
    • /
    • pp.383-387
    • /
    • 2014
  • In this paper, for a new detection system development with the better accurate dose evaluation and beam distribution imaging using the small field irradiation of linear accelerator, the compound semiconductor based detection sensors were fabricated and the performance evaluation was investigated. The special particle-in-binder sedimentation was used for a large area film sensor fabrication. The detection properties for high energy x-rays were investigated from a dark current, an output current, a rising time, a falling time, and response delay measurement. The experimental results, the $TiO_2$ mixed $HgI_2$ sensor showed the best electrical characteristics than $PbI_2$, PbO, pure $HgI_2$. Linearity, repeatability, and accuracy tests from LINAC were tested, the $TiO_2$ mixed $HgI_2$ sensor showed the better performance than the commercially available dosimetry devices.

Hydrological survey and analysis considering field conditions (현장여건을 고려한 수문조사 및 분석)

  • HwangBo, Jong-Gu;Yu, Young-moo;Jeong, Chan-Woong;Lee, Sang-Ho;Seo, Jeong-Min
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.265-265
    • /
    • 2022
  • 유량조사는 측선수, 측정시간, 측정위치, 측정방법 등 많은 기준이 있으며 이를 잘 준수하는 것이 높은 품질의 유량측정 성과를 확보하는 방법이다. 그러나 이러한 기본적인 기준을 잘 준수하더라도 현장 상황에 따라 유량측정 성과에 오차가 포함 될 수 있다. 본 연구에서는 상류 소수력발전소의 방류량에 따라 유량이 변화하고 수위관측소 부근에 큰 저류공간이 있는 현장 여건이 유량측정성과에 어떠한 영향을 끼치는지 검토하였다. 홍천군(주음치교) 관측소는 홍천강 상류에 위치하며 소수력발전소의 운영에 따라 관측소를 흘러가며 그 유량이 소수력발전소의 영향으로 점변한다. 일반적으로 이러한 경우 측정시간을 최대한 짧게 가져가 유량자료의 정확도를 확보한다. 하지만 홍천군(주음치교)의 경우 수위관측소 주변에 큰 저류공간이 있어 이를 동시에 고려해야 하며 단순하게 측정시간을 짧게 하는 것만으로는 측정성과의 품질을 확보 할 수 없다. 왜냐하면 이 저류 공간으로 물이 유입되는 시간동안은 수위관측소의 수위 상승은 미미하지만 하천 유량은 증가하는 부등류가 발생한다. 유량측정은 등류가정에 의한 것으로 수위관측소 주변이 부등류가 발생하면 유량측정 성과에 큰 오류가 나타나기도 한다. 홍천군(주음치교)에서 현장 상황이 등류일 때와 부등류일 때 모두 측정을 실시하였으며 그 차이를 확인하였다. 저류공간의 물 유입이나 유출이 없는, 즉 등류 상태의 유량측정 성과는 수위-유량관계식과 2.86%차이를 보였으며 부등류 상태의 유량측정 성과는 19.85%차이를 보여 큰 차이를 보였다(기준수위 0.49m). 또한 소수력발전소 운영에 따라 유량 상승 시에는 수위-유량관계곡선식 대비하야 양(+)의 편차율이 발생하고, 유량이 하강 시에는 수위-유량관곡선식 대비 음(-)의 편차율 발생하는 것으로 나타났다. 소수력 발전소는 동절기를 제외한 상시 운영으로 홍천군(주음치교) 관측소의 정확한 수위-유량관계식을 확인하기 위하여 소수력 발전소 운영을 중단하고 측정을 실시하였으며 유량변동을 멈추고, 즉 등류 흐름에서 측정한 성과는 수위-유량관계식과 차이가 1.06% 불과한 것으로 나타났다. 수문조사는 측선수, 측정시간, 측점수 등 많은 기준이 있다. 그러나 이러한 측정기준과는 별개로 현장은 다양한 조건이 발생하며 측정성과의 정확도에 영향을 끼치는 경우가 발생하기도 한다. 따라서 유량측정 기준을 잘 준수하는 것도 중요하지만 현장상황을 파악하고 이에 적절한 유량측정을 실시해야 그 오차를 최소화 할 수 있다.

  • PDF

A Study on the Remote Control for Exit Sign Using High Efficiency LED (고효율 LED를 이용한 유도등의 원격제어에 관한 연구)

  • 백동현;홍석표
    • Fire Science and Engineering
    • /
    • v.16 no.2
    • /
    • pp.1-7
    • /
    • 2002
  • In the normally, exit sign is always lighting on status by the connected to normal electrical source. So, there are happened to rise of the economical cost such as power consumption, maintenances and repair replacement of lamp etc. This paper are study on the new exit sign circuits by using high efficiency LED that is available for remote control and reduceible to power consumption, maintenance cost by the way of compensation fluorescent and incandescent lamps. As a results on the study, exit sign lamp is capable of control and supervisory in trigger angle by the remote control switch, widely and easily. And then, the response time was very fast in 600〔$\mu$s〕and also it can be find that the rising and fall time of oscillate circuit is maximum 200〔ns〕 as high sensitively. Finally, it obtain to the result that reducible of electrical power consumption and not required for replacement of lamp by using the high efficiency LED lighting source.

Development of the Hydraulic Performance Graph Model and its Application (수리거동곡선 모형의 개발 및 적용)

  • Seo, Yongwon;Seo, Il Won;Shin, Jaehyun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.5
    • /
    • pp.1373-1382
    • /
    • 2014
  • This paper presents a hydraulic performance graph model in which the flow carrying capacity of a channel system was determined by accounting the interacting backwater effect among channel reaches and incoming lateral flow. The method utilizes hydraulic performance graphs (HPGs), and the method is applied to a natural channel Nakdong River to examine its applicability. This research shows that estimation results using HPG are close to records from the stage station and the results from a widely-accepted model, HEC-RAS. Assuming that a water level gage site is ungaged, water level estimations by HPGs compared with observation show that with a flood event, the HPGs underestimate in the water level ascension phase, but in the recession phase they overestimate results. The accuracy of estimation with HPGs was greatly improved by considering the time difference of flooding between the observation and estimation locations.

Classification of hysteretic loop feature for runoff generation through a unsupervised machine learning algorithm (비지도 기계학습을 통한 유출 발생 내 이력 현상 구분)

  • Lee, Eunhyung;Jeon, Hangtak;Kim, Dahong;Friday, Bassey Bassey;Kim, Sanghyun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.360-360
    • /
    • 2022
  • 토양수분과 유출 간 관계를 정량화하는 것은 수문 기작 및 유출 발생 과정의 이해를 위한 중요한 정보를 제공한다. 특히, 유출과정의 특성화는 수문 사상에 따른 불포화대 내 토양수 및 토사 손실 제어와 산사태 및 비점오염원 발생 예측을 위해 필수적이다. 유출과정과 관련된 비선형성과 복잡성을 확인하기 위해 토양수분과 유출 사이의 이력 거동이 조사되었다. 특히, 수문 과정 내 이력 현상 구체화를 위해 정성적인 시각적 분류 및 정량적 평가를 위한 이력 지수들이 개발되었다. 정성적인 시각적 분류는 시간에 따라 시계 및 반시계방향으로 다중 루프 형상을 나누는 방식으로 진행되었고, 정량적 평가의 경우 이력 고리(Hysteretic loop) 내 상승 고리(Rising limb)와 하강 고리(Falling limb)의 차이를 기준으로 한 지수로 이력 현상을 특성화하였다. 이전에 제안된 방법론들은 연구자의 판단이 들어가기 때문에 보편적이지 않고 이력 현상을 개발된 지수에 맞춤에 따라 자료 손실이 나타나는 한계가 존재한다. 자료의 손실 없이 불포화대 내 발생 가능한 대표 이력 현상을 자동으로 추출하기 위해 적합한 비지도 학습기반 기계학습 방법론의 제안이 필요하다. 우리 연구에서는 국내 산지 사면에서 강우 사상 동안 다중 깊이(10, 30, 60cm)로 56개의 토양수분 측정지점에서 확보된 토양수분 시계열 자료와 산지 사면 내 위어를 통해 확보된 유출 시계열 자료를 사용하였다. 먼저, 기존에 분류 방법을 기반으로 계절 및 공간특성에 따라 지배적으로 발생하는 토양수분-유출 간 이력 현상을 특성화하였다. 다음으로, 토양수분-유출 간 이력 패턴을 자료 손실 없이 형상화하여 자동으로 데이터베이스화하는 알고리즘을 개발하였다. 마지막으로, 비지도 학습방법을 이용하여 데이터베이스화된 실제 발현 이력 현상 내 확률분포를 최대한 가깝게 추정하는 은닉층을 반복적인 재구성 학습을 통해 구현함으로써 대표 이력 현상 패턴을 추출하였다.

  • PDF