Magma Pathway of Alkali Volcanic Rocks in Goseong, Gangwon-do, Korea (강원도 고성지역에 분포하는 알칼리 현무암질 마그마의 상승경로)

  • Kil, Young-Woo;Shin, Hong-Ja;Ko, Bo-Kyun
    • The Journal of the Petrological Society of Korea
    • /
    • v.16 no.4
    • /
    • pp.196-207
    • /
    • 2007
  • Miocene basalt plugs in Goseong contain a large variety of crustal and mantle xenoliths and xenocrysts. One of basalt plugs, Unbongsan, are derived from 160 km depth. Whole-rock geochemistry and pressure and temperature conditions of mineral phases indicate that Unbongsan volcanic rocks are alkali basalts and the source magma of the alkali basalts was generated from about $0.2{\sim}2%$ partial melting of depleted garnet peridotite. Crystallization pressures and temperatures of mineral phases within ascending magma of Unbongsan alkali basalt indicate that olivines, clinopyroxenes, and plagioclases were crystallized at $75{\sim}110km,\;40{\sim}52km,\;37{\sim}54km$ depth, respectively. The ascending magma of Unbongsan alkali basalts enclosed mantle xenoliths at about $57{\sim}67km$ depth.

A Study on the Heating of Lipiodol during Lymphangiography (림프관 조영술 시 리피오돌의 가온에 관한 고찰)

  • Kang, Rae-Wook;Kim, Jae-Seok
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.5
    • /
    • pp.597-602
    • /
    • 2020
  • The study was conducted to improve the efficiency of the test and to reduce the exposure dose of patients and operators by analyzing the difference in the moving speed of Lipiodol according to the temperature during lymphography. The device for injecting Lipiodol at a constant pressure was self-made, and after inserting Lipiodol into the Connecting Tube, the moving speed of the contrast agent was photographed at temperatures of 26℃, 36℃, and 46℃ using a heat transfer device. Lipiodol movement time from the Support Catheter to 20cm was measured and analyzed, and statistical significance was confirmed. In the 46℃ environment, the average moving time was 11 seconds, at 36℃ the average was 13 seconds, and at 26℃ the average was 17 seconds. Lipiodol showed a significant difference in moving time with increasing temperature (p<.001), and it was confirmed that the higher the temperature, the faster the moving speed. In the case of lymphangiography, when heated to a certain temperature (46 degrees) rather than injecting Lipiodol at room temperature, the injection speed can be increased and the speed of movement in the lymphatic vessel can be improved.

Environmentally Sound Land Use Planing in Cheju Island, Korea (제주도 중산간 지역의 환경보전적 토지 이용 계획)

  • 양하백
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 1997.11a
    • /
    • pp.145-159
    • /
    • 1997
  • Cheju Island is the most attractive resort area in Korea for its exotic landscape, natural beauty, and traditional culture which is quite different from that of the mainland. Until now, most of the recreational facilities and accomodations have been constructed along the coastal areas. Recently, mid-mountain area has been under very heavy development pressure because it is suitable for new sites for tourism facilities and the land price in the coastal area is very high. The mid-mountain area is the land located 200-600m above the sea level. It is a major source of water supply for the island and has exotic scenic beauty, which cannot be found in mainland but it is the area very vulnerable to water pollution Therefore, it is very important to manage this area based on the concept of environmentally sound and sustainable development in order to meet ever increasing demand for the land development The purposes of this project are: 1) to establish Geographic Information System for the whole island, 2)to formulate environmentally sound landuse plat However, There has been accuracy of the original map, defining criteria of analysis, updating of the data were identified for future tasks to be studied.

  • PDF

Evaluation of Metering Accuracy of Hydrogen Station Using Master Meter Method (표준유량계법을 적용한 수소 충전소 계량 정확도 평가)

  • Han, Wonguk;Yim, Sangsik;Song, Bohee;Kil, Sunghee;Kim, Younggyu;Kim, Hongchul
    • Journal of the Korean Institute of Gas
    • /
    • v.23 no.6
    • /
    • pp.67-73
    • /
    • 2019
  • Hydrogen is difficult to accurately measure the amount of charge due to sudden temperature changes and pressure rise when charging the vehicle. In order to construct a hydrogen infrastructure, it is important to precisely measure the amount of charge that can be a sensitive issue in commercial transactions. In this study, the accuracy of metering of domestic hydrogen stations was evaluated as a study for metering management of hydrogen dispenser. For the experiment, we constructed metering system using master meter method and measured the flow rate in the actual hydrogen vehicle charging environment. As a result of error occurred about 10% on average, and the hydrogen loss per one charge was found to be up to 60g.

Microwave Irradiation에 따른 용액 공정에 의한 HfOx 기반의 MOS Capacitor의 전기적 특성 평가

  • Jang, Gi-Hyeon;O, Se-Man;Park, Jeong-Hun;Jo, Won-Ju
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.358-358
    • /
    • 2014
  • 인간과 기기간의 상호작용 심화에 의하여 모든 기기의 지능화, 첨단화 등이 요구됨에 따라 정보 기술 및 디스플레이 기술의 개발이 활발히 이루어지고 있는 가운데 투명 전자 소자에 대한 연구가 급증하고 있다. 산화물 반도체는 가시광 영역에서 투명하고, 비정질 반도체에 비하여 이동도가 100 배 이상 크고, 결정화 공정을 거친 폴리 실리콘과 비슷한 값을 가지거나 조금 낮으며 유연한 소자에도 쉽게 적용이 가능하다는 장점을 가지고 있어 투명 전자 소자 제작시에 주로 이용되는 물질이다. 대부분의 산화물 반도체 박막 증착 방법은 스퍼터링 방법이나 유기금속 화학증착법과 같은 방법으로 막을 형성하는데 이러한 증착 방법들은 고품질의 박막을 성장시킬 수 있다는 장점이 있으나 고가의 진공장비 및 부대 시설이 이용되고 이로 인한 제조비용의 상승이 되고, 기판 선택에 제약이 있는 단점이 있다. 따라서, 이러한 문제점을 개선하기 위하여 고가의 진공 장비가 필요 없이 스핀 코팅 방법이나 딥핑 방법 등에 의하여 공정 단계의 간소화, 높은 균일성, 기판 종류에 상관없는 소자의 대면적화가 가능한 용액 공정 기술이 각광을 받고 있다. 그러나 용액 공정 기반의 박막을 형성하기 위해서는 비교적 높은 공정온도 혹은 압력 등의 외부 에너지를 필요로 하므로 열에 약한 유리 기판이나 유연한 기판에 적용하기가 어렵다. 최근 이러한 문제점을 해결하기 위하여 높은 온도의 열처리(thermal annealing) 를 대신 할 수 있는 microwave irradiation (MWI)에 대한 연구가 보고되고 있다. MWI는 $100^{\circ}C$ 이하에서의 저온 공정이 가능하여 높은 공정 온도에 대한 문제점을 해결할 뿐만 아니라 열처리 방향을 선택적으로 할 수 있다는 장점을 가지고 있어 현재 투명 디스플레이 분야에서 주로 이용되고 있다. 따라서 본 연구에서는 HfOx 기반의 metal-oxide-semiconductor (MOS) capacitor를 제작하여 MWI에 따른 전기적 특성을 평가하였다. MWI는 금속의 증착 전과 후, 그리고 시간에 따른 조건을 적용하였으며 최적화된 조건의 MWI은 일반적인 퍼니스 장비에서의 높은 온도 열처리에 준하는 우수한 전기적 특성을 확인하였다.

  • PDF

Optimization of Parallel Code for Noise Prediction in an Axial Fan Using MPI One-Sided Communication (MPI 일방향통신을 이용한 축류 팬 주위 소음해석 병렬프로그램 최적화)

  • Kwon, Oh-Kyoung;Park, Keuntae;Choi, Haecheon
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.7 no.3
    • /
    • pp.67-72
    • /
    • 2018
  • Recently, noise reduction in an axial fan producing the small pressure rise and large flow rate, which is one type of turbomachine, is recognized as essential. This study describes the design and optimization techniques of MPI parallel program to simulate the flow-induced noise in the axial fan. In order to simulate the code using 100 million number of grids for flow and 70,000 points for noise sources, we parallelize it using the 2D domain decomposition. However, when it is involved many computing cores, it is getting slower because of MPI communication overhead among nodes, especially for the noise simulation. Thus, it is adopted the one-sided communication to reduce the overhead of MPI communication. Moreover, the allocated memory and communication between cores are optimized, thereby improving 2.97x compared to the original one. Finally, it is achieved 12x and 6x faster using 6,144 and 128 computing cores of KISTI Tachyon2 than using 256 and 16 computing cores for the flow and noise simulations, respectively.

A Study on the Optimum Clearance Selection of Fuel Pump Journal Bearing with Elasto-hydrodynamic Lubrication Analysis (탄성유체윤활해석에 의한 연료 펌프 저널베어링 최적간극 선정 연구)

  • An, Sung Chan;Lee, Sang Don;Son, Jung Ho;Cho, Yong Joo
    • Tribology and Lubricants
    • /
    • v.33 no.1
    • /
    • pp.23-30
    • /
    • 2017
  • The electric controlled marine diesel engine has fuel pump generating the high pressurized fuel for fuel injection to combustion chamber via a common rail. Fuel pump consists of a cam-roller system. Journal bearing installed between a roller and a cam-roller pin is subjected to fluctuating heavy and instant loads by cam lift. First, Kinematic analysis is carried out to predict bearing loads during one cycle acting on the journal bearing. Second, flexible multi-body dynamic analysis and transient elasto-hydrodynamic(EHD) lubrication analysis for journal bearing considering elastic deformation of cam-roller pin, roller and bearing are conducted using AVL EXCITE/PU software to predict lubrication performance. The clearance ratio and journal groove shape providing lubrication oil are important parameter in bearing design having good performance and can be changed easier than other design parameters such as diameter, width, oil supply pressure and bearing material grade. Generally, journal bearing performance is represented by the minimum oil film thickness(MOFT) and peak oil film pressure(POFP). As well as the traditional design parameters(MOFT, POFP), in this study, temperature rise of lubrication oil is also evaluated through the side leakage flow of supplied oil. By the evaluating MOFT, POFP and temperature rise, the optimum bearing clearance ratio is decided.

Study on the Radioactive Liquid Waste Treatment of Cooling and Decompression Process of Spent Fuel Assembly Cask (사용후핵연료 집합체 캐스크 감온, 감압 공정의 방사성 액체폐기물 처리 대한 연구)

  • 손영준;전용범;김은가;엄성호;권형문;민덕기;양송열;이은표;이형권
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2003.11a
    • /
    • pp.83-89
    • /
    • 2003
  • A temperature- and pressure-reducing process is utilized to handle the spent fuel assembly in the post-irradiation examination facility. This process includes three separated unit processes. First one is the decontamination process to clean the spent fuel assembly casks. The second process is the temperature-reducing process to reduce the temperature elevated by decay process in the spent fuel assembly. The third process is the filtration process to remove insoluble particles existed in the casks using filters. Up-to-date technologies as well as practical theories related to the temperature- and pressure-reducing process is reviewed in this report. The test-operation process for various tests and the test results of the temperature- and pressure-reducing process for J-44 and K-23 spent fuel assemblies are also described in detail. This report must be effectively used for the normal operation of the facility with the awareness of unprecedented problems which could occur by continuing operation of the PIE facility.

  • PDF

Effect of Injector Cooling on Ignition of Cryogenic Spray (분사기 냉각이 초저온 분무의 점화에 미치는 영향)

  • Kim, Do-Hun;Lee, Jin-Hyuk;Koo, Ja-Ye
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.40 no.3
    • /
    • pp.222-229
    • /
    • 2012
  • The cooling of a injector effects on the vapor pressure of cryogenic oxidizer spray, and it decides the phase transition point at the ignition process, when the combustion chamber pressure increases drastically. The phase transition of oxidizer spray affects the ignition characteristics, and several ignition tests with the LOx/$GCH_4$ uni-element coaxial swirl injector was performed in the different initial temperatures of oxidizer injector, in order to investigate the effect of injector cooling on the ignition transient characteristics. At the transition point of oxidizer phase, where the combustion chamber pressure increased over the LOx vapor pressure, the temporary quenching phenomenon of the flame occurred. The lower temperature of chilled down injector and tubing tends to move up the phase transition earlier.

Solid Circulation Characteristics in a 3 kW Chemical-looping Combustor (3 kW급 매체순환식 가스연소기의 고체순환특성)

  • Ryu, Ho-Jung;Park, Jaehyeon;Kim, Hong-Ki;Park, Moon-Hee
    • Korean Chemical Engineering Research
    • /
    • v.46 no.6
    • /
    • pp.1057-1062
    • /
    • 2008
  • To overcome disadvantages of conventional two interconnected fluidized beds system, a novel two-interconnected fluidized bed process has been adopted to 3kW chemical-looping combustor. This system has two bubbling beds, solid injection nozzles, solid conveying lines, and downcomers. In this study, effects of operating variables such as gas velocity through the solid injection nozzle, fluidizing velocity, solid height, geometry of solid intake hole, bed temperature on solid circulation rate have been investigated in a 3kW chemical-looping combustor. The solid circulation rate increased as the solid height and the opening area of solid intake holes increased. The effect of the fluidizing velocity and the bed temperature were negligible. Moreover, long-term operation of continuous solid circulation up to 50 hours has been performed to check feasibility of stable operation. The pressure drop profiles in the bubbling beds and the downcomers were maintained steadily and solid circulation was smooth and stable.