• Title/Summary/Keyword: 상사법칙

Search Result 111, Processing Time 0.029 seconds

A Study on the Theory of Simulation Rule for Scale Model Experiment in Architectural Acoustics (건축음향모형실험의 상사법칙의 이론에 관한 연구)

  • Kim, Cheon-Su;Sin, Yeong-Mu;Park, Byeong-Jeon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.13 no.1
    • /
    • pp.93-98
    • /
    • 1994
  • This study aims to find the theoretical consideration of the basic simularity rule between scale model experiment and real building as a results ; 1. In the case of room acoustics, $f_m=n\cdot{f_r}\;T_m=T_r/n\; \alpha_m(f_m)=\alpha_r(f_r)$ 2. That of sound Insulation : $TL_m(f_m)=TL_r(f_r)$

  • PDF

Plane buoyant jet in cross flow (가로흐름에 방류되는 평면부력젤)

  • Han, Mun-U;Yoon, Tae-Hun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 1987.07a
    • /
    • pp.89-97
    • /
    • 1987
  • 가로흐름에 방류되는 연직평면부력젤의 젤중심선경로와 온도분포를 실험자료와 기본방정식으로부터 유도된 적분식에 의하여 해석한다. 기본방정식으로부터 적분식의 유도는 상사법칙과 특성길이를 도입하여 연직상향 및 수평방향흐름영역에 대한 차원해석을 하였고, 실험은 속도비(R=Wo/Ua)와 방류밀도Froude수를 변화시키면서 각각에 따른 젤중심선경로와 온도분포를 획득하였다. 속도비 R과 방류밀도Froude수 Fo에 따라 부력젤의 흐름특성은 달라지게 되며, 초기조건(운동량및 부력)에관계없이 부력젤은 항상 운동량지배영역이 존재함을 알 수 있었고 적분식에 의한 역법칙(power law)과 실험 자료는 대체로 일치된결과를 나타내었다.

  • PDF

Failure Mechanism of Geosynthetic Reinforced Segmental Retaining Well in Tiered Configuration Using Reduced-scale Model Tests (축소 모형 실험에 의한 계단식 보강토옹벽의 파괴 메카니즘)

  • Yoo Chung-Sik;Jung Hyuk-Sang;Jeon Sang-Soo;Lee Bong-Won;Kim Ki-Yeon;Jeon Han-Yong
    • Journal of the Korean Geotechnical Society
    • /
    • v.21 no.3
    • /
    • pp.65-77
    • /
    • 2005
  • This paper investigates the failure mechanism of geosynthetic-reinforced segmental retaining walls with tiered configuration using reduced-scale model tests. The reduced scale model test set-up was established to simulate a 5 m high full-scale wall. The geometry and material properties used in the model test were determined based on the Similitude Laws. The wall failures in the model tests were successfully generated by their self weight without any surface loading and analyzed examining the digital video recordings. The failure mechanisms was examined with respect to the various offsets between the lower and upper teres and the reinforcement length. Based on the results the appropriateness of the current design guideline was discussed.

Plane Experiment Study on Drainage Capacity of Sluice Gate by Slope and Length of Apron (Apron 경사 및 길이에 따른 수문구조물 배수능 평면실험 연구)

  • Yoon, Kwang-Seok;Yeo, Kyu-Dong
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2005.05b
    • /
    • pp.1031-1035
    • /
    • 2005
  • 조력발전 건설사업에서 우선적으로 고려되어야 할 사항은 조수간만에 의해 외해부와 조지부 사이를 이동하는 해수를 적절히 소통시키는 것이다. 즉, 조력발전소에서 수문구조물의 목적은 주어진 조건 하에서 계획된 유량을 충분히 그리고 안전하게 배제시키는 것이다. 본 연구에서는 수문구조물에 대한 Apron의 길이와 경사의 변화에 의한 외해 조위와 시화호 수위차 조건에 따른 유량계수를 구해 배수능력과 유$\cdot$출입부, 외해, 시화호 및 큰가리섬 주위의 흐름 특성을 검토하고자 하였다. 이를 위해 시화호를 실험대상으로 하여 구조물을 중심으로 외해측으로 1,000m, 시화호측으로 500m, 폭 1,500m의 범위를 선정하였다. 수리모형을 1대50의 축척비로 제작하였다. 표 1은 실험별 Apron과 수문구조물의 제원을 나타내며, 수문구조물은 7기로 이루어졌다. 시화호의 흐름은 관성력과 중력이 지배력이 되며, 이때 상사법칙은 Froude 상사법칙을 적용할 수 있다. 실험III은 실험II에서 Apron의 경사를 1대10에서 1대5로 수정한 실험으로 수위조건은 외해측 -2.530 EL.m이고, 시화호측은 -1.603EL.m이다. 유량계수를 산정하기 위하여 6개 실험조건을 기본계획에서 제시된 수위-조위 조건에서 수위차 및 통수유량을 분배하여 결정하였고 유량계수 산정식에 따라 구조물의 유입부와 유출부에서 유속-면적법에 의해서 유량을 측정하였다. 그리고 국부평면 실험모형에서의 전체적인 해류의 흐름을 분석하기 위해 2차원 유속을 측정하였다. 또한, 유$\cdot$출입부 안정성을 검토하기 위해 Apron 지점과 수문구조물 지점에 3점법으로 유속을 측정하였으며, 색소를 이용하여 유황을 관찰하였다. 시화호와 외해의 수위차가 1.011 m일 때의 전체 수문구조물을 통과하는 유량을 비교한 결과, 실험II 및 실험III의 통과유량은 각각 $10,924m^3/s$$10,075m^3/s$로서 실험 I의 $2,757m^3/s$에 비해 통수능이 많이 개선되었음을 알 수 있다.

  • PDF

Experimental study for analysis of hydraulic characteristics around dams (댐 주변의 수리특성 분석을 위한 실험적 연구)

  • Baek, Donghae;Yoon, Jae-Seon;Lee, Byeong Wook;Jang, Eun Cheul;Song, Hyun-Gu
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.257-257
    • /
    • 2022
  • 댐 건설은 홍수 및 가뭄에 대응하기 위한 구조적 방법으로써 우리나라와 같이 지표수에 의존적인 지역에서는 가용 수자원을 확보하기 위한 확실한 수단으로 활용되어왔다. 신규 댐의 건설은 대상 하천의 수리학적 특성에 큰 변화를 야기할 수 있으며, 댐의 안정성 및 하천의 하도보호를 위해 댐 주변의 수리적 특성의 변화에 대해서도 사전에 인지하여 설계 시 반영할 필요가 있다. 수공구조물 신설에 따라 변화되는 수리학적 특성을 분석하는 방법으로는 그 수단에 따라 상사법칙을 적용한 수리모형실험과 수치기법을 활용한 수치모형실험으로 나눌 수 있다. 본 연구에서는 수리모형실험을 통한 실험적 방법을 이용하여 댐 상하류 구간의 수리학적 특성을 분석하였다. 해당 실험은 한국농어촌공사 농어촌연구원의 대형수리모형실험시설에서 수행되었다. 적용대상 댐의 제원은 높이 약 70m, 길이 약 230m이며, 폭 55m의 여수로를 포함하는 구조로 설정하였다. 수리모형은 Froude 상사법칙을 적용하여 1/30 규모로 축소하였으며, 콘크리트 및 아크릴 재료를 이용하여 제작되었다. 댐 모형이 설치되는 하천구간은 댐 구조물을 포함하여 실규모를 기준으로 흐름방향으로 약 800m, 하폭방향으로 약 450m의 범위를 포함하도록 설계되었으며, 하류구간에 사행하천이 존재하는 것이 특징이다. 본 실험에서 유량은 총 12개의 펌프를 이용하여 공급되었으며, 최대 4cms에 해당하는 유량공급이 가능하도록 설계하였다. 공급유량은 정교한 절차에 의해 보정된 전자식 유량계를 통해 통제되었으며, 사용된 유량계의 허용오차는 약 0.5% 수준인 것으로 나타났다. 수위 측정은 오차범위 0.05mm 수준의 초음파 수위측정기를 이용하였으며, 유속측정은 약 0.5cm/s의 정확도를 지닌 3차원 전자기 유속계를 이용한 접촉식 측정과 흐름구조 가시화를 위한 비접촉식 입자추적기법을 병행하였다. 실험조건은 실규모 기준으로 방류량 3,000~5,000cms에 대해 수행하였으며, 각 방류량별 댐 상하류의 흐름패턴에 대해 정량적으로 분석하였다.

  • PDF

A Study on the Analysis of Hydrologic Similarity of the Catchment Response(I) (유역응답의 수문학적 상사성해석에 관한 연구(I))

  • 조홍제;이상배
    • Water for future
    • /
    • v.23 no.4
    • /
    • pp.421-434
    • /
    • 1990
  • The problems of hydrologic similarity among river basins was analyzed by a geomorphologic response model using Hortons*s ordering scheme. The Nash model was used for deriving the geomorphologic response function, and for the optimization of the responsefunction, imcomplete gamma function andRosso*s regression equation were used. The application of this method was tested on some observed flood data of Pyungchang river basin and Wi Stream basin and Bocheong stream, and predictions of hydrologic response were compared with that of the Moment method. The results show that the proposed model and dimensionless instantaneous unit hydrograph can be used for the runoff analysis of an ungauged basin and the analysis of hydrologic similarity.

  • PDF

로켓엔진용 연료펌프의 성능 시험

  • Kim, Dae-Jin;Hong, Soon-Sam;Choi, Chang-Ho;Kim, Jin-Han
    • Aerospace Engineering and Technology
    • /
    • v.4 no.1
    • /
    • pp.143-149
    • /
    • 2005
  • To evaluate the hydraulic and cavitation performance of a fuel pump for a liquid rocket engine, performance tests of the pump, which consist of hydraulic tests and cavitation tests, were conducted in water environment with various condition. In the hydraulic tests, the head, efficiency and volute pressure distribution of the pump are found to follow the conventional similarity rule, whereas the secondary flow pressure shows a small deviation from the similarity rule. As the floating gap is constricted, the efficiency of the pump improves and the secondary flow pressure decreases. However, the inner diameter of bypass line orifice does not show clear relationship with the pump efficiency. In the cavitation tests, measurements of the head and the NPSH indicate that the pump shows better cavitation performance as the rotational speed of the pump increases.

  • PDF

Analysis of drainage structure for river basin on the basis of power law distribution (멱함수 법칙분포를 기반으로 한 유역의 배수구조에 대한 해석)

  • Kim, Joo-Cheol;Kang, Heeseung;Jung, Kwansue
    • Journal of Korea Water Resources Association
    • /
    • v.49 no.6
    • /
    • pp.495-507
    • /
    • 2016
  • This study aims at hydrologically demonstrating the universality of power law distribution by analyzing runoff aggregation structures of river basins. Power law distribution is fitted to cumulative drainage area of basins of interest by maximum likelihood, which results in the power law exponents. And then those exponents are assessed in terms of the shape of catchment plan-form. As a main result all of the basins in this study have similar distributions of catchment area. The exponents from this study tend to be higher than the ones from previous researches reflecting self-similar property of the catchment plan-forms of interest. Further study is required about the universality of power law distribution by means of the more realistic flow routing scheme within the framework of DEM.

Applicability of Similitude Law for 1-g shaking table tests (1-g 진동대 모형시험에서의 상사법칙 적용성 평가)

  • 황재익;김성렬;이용재;김명모
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2002.03a
    • /
    • pp.75-82
    • /
    • 2002
  • Shaking table model tests are performed to reproduce the dynamic behavior of a gravity quay wall and a pile-supported wharf damaged by Kobe earthquake in 1995. Using the scaling relations suggested by Scott and Iai(1989), the results of the model tests are compared with field measurements as well as with those of the model tests previously executed. The displacements of the gravity quay wall predicted by the current model tests are, at most, one third of the measured displacements, while the displacements of the model pile-supported wharf are about two thirds of the measured values. One possibility for the discrepancy is speculated to be the use of too big scaling factor, i.e., too small size of model.

  • PDF

Study on the Development of Integrated Vibration and Sound Generator (휴대폰용 일체형 음향 및 진동 발생장치 개발을 위한 연구)

  • 신태명;안진철
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.13 no.11
    • /
    • pp.875-881
    • /
    • 2003
  • The received signal of a mobile phone is normally sensed through two independent means which are the sound generation of a speaker and vibration generation of a vibration motor. As an improvement scheme to meet the consumer's demand on weight reduction and miniaturization of a mobile phone, the design and development of an integrated vibration and sound generating device are performed in this research. To this purpose, the optimal shapes of the voice coil. the permanent magnet and the vibration plate are designed, and the excitation force applied to the vibration system of the new device is estimated and verified through theoretical analyses, computer simulation, and experiments using an expanded model. In addition, vibration performance comparison of the device with the existing vibration motor is performed, and from the overall process, therefore, the method and procedure for the vibration performance analysis of the integrated vibration and sound generating device are established.