• Title/Summary/Keyword: 상부 냉각

Search Result 89, Processing Time 0.028 seconds

Natural convection cooling of discrete heaters with same heat generation in a vertical open top cavity (상부가 개방된 수직 캐비티내에 장착된 불연속 균일 발열체의 자연대류 냉각)

  • Yu, Gap-Jong;Chu, Hong-Rok;Kim, Byeong-Ha;Choe, Byeong-Cheol
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.1
    • /
    • pp.1-14
    • /
    • 1997
  • Natural convection cooling of discrete heaters located in a two-dimensional vertical open top cavity is investigated experimentally. The five discrete heaters with same heat generation are located on the wall of the cavity. The heaters are arranged in two configurations; flush-mounted on a vertical wall and protruding from the wall about 4.5 mm. The materials used for the vertical walls are copper and epoxy-resin, and air is used as the cooling fluid. The temperature and flow fields in the cavity were visualized by means of Mach-Zehnder interferometer and smoke-method. Also, local temperature measurements are made along the vertical wall. Results are obtained for cavity aspect ratios of 4.6, 7.5 and 9.5 and modified Rayleigh numbers ranging from 10$^{3}$ to 10$^{6}$ . Results indicate that the cooling efficiency for the copper wall is superior to that of the epoxy-resin. For the epoxy-resin wall, the protrusion of the heaters plays a role in decreasing the heat transfer performance. The location of maximum temperature is significantly influenced by the wall materials and heater configurations. Correlations relating the Nusselt number to the modified Rayleigh number are proposed.

Numerical Study and Firing Test of a Liquid Rocket Engine Head with a Coolant Manifold (로켓엔진 헤드용 냉각 매니폴드의 해석 및 시험)

  • Park, Jinsoo;Choi, Jiseon;Yu, Isang;Ko, Youngsung;Kim, Sunjin;Shin, Dongsun
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.1021-1025
    • /
    • 2017
  • Numerical heat/flow analysis was performed on a liquid rocket engine head with the cooling water manifold to ensure the durability of a ground test facility for heat exchanger. Through these studies, the shapes of the injector and the flow path were determined and applied to the head of the engine under development. Firing tests were conducted to verify the designed coolant manifold and no thermal damage was found on the engine-head-face. Comparing the combustion test results with the numerical analysis, the outlet temperature of coolant showed a difference of about $15^{\circ}C$. This trend is reasonable considering existence of LOX manifold, thermal barrier coating, and the actual location of flame.

  • PDF

The Impact of Interaction between Cloud and Longwave Radiation In Asia Monsoon Circulation (구름-장파복사 상호작용이 아시아 몬순 순환에 미치는 영향)

  • Yu, Geun-Hyeok;Son, Byeong-Ju
    • 한국지구과학회:학술대회논문집
    • /
    • 2003.09a
    • /
    • pp.112-125
    • /
    • 2003
  • 구름의 몬순의 활동에 있어서 직접적으로나 간접적으로 영향을 준다. 본 연구에서는 이러한 구름이 몬순의 활동에 어떠한 영향을 주는지를 알아보기 위해 ISCCP 구름자료와 GAME 재분석 자료를 입력자료로한 장파 복사 모델을 수행하였다. 모델 수행의 결과로 얻어진 대기 상부에서의 플럭스는 CERES 관측치와 비교하였으며, 구름에 의한 가열율은 몬순활동을 해석하기 위해 사용하였다. 구름이 몬순에 끼치는 영향을 파악하기 위해 맑은 대기의 가열율과 구름을 포함한 평균 대기의 가열율의 차이를 구하였으며, 이를 수평과 연직분포의 관점에서 해석하였다. 가열율의 지리적 분포는 수평적으로는 인도양에서 장파 복사 가열율의 최대가 나타났으며, 가열의 최저 (냉각)은 티벳고원에 나타났다. 이러한 공간적 분포는 구름이 남북방향으로 차등가열을 유발시키고 있음을 보여주고 있어 구름의 분포가 열적인 몬순순환을 강화시켜주고 있음을 시사하고 있다. 이러한 차등가열의 강화는 동서방향으로도 나타나 구름이 동서방향 순환에도 영향을 줄 수 있음을 보여준다. 구름에 의한 복사 가열의 연직구조는 운정에 의한 냉각과 운저에 의한 가열이 일어날 수 있음을 보여주고 있으며, 이로 인해 대기의 불안정성이 높아져 연직 운동을 향상시킬 수 있는 역할을 하고 있음이 밝혀졌다. 즉 몬순순환에 의해 생성된 구름은 구름 생성의 원인이 되었던 순환을 더욱 강화시키고 있음을 보이고 있다.

  • PDF

Analysis on Pool Temperature Variation along Pool Water Management System Operation in Research Reactor (연구용원자로에서 수조수관리계통 운전에 따른 수조수 온도 해석)

  • Choi, Jungwoon;Lee, Sunil;Park, Ki-Jung;Seo, KyoungWoo
    • Transactions of the KSME C: Technology and Education
    • /
    • v.5 no.2
    • /
    • pp.135-143
    • /
    • 2017
  • The domestic unique research reactor, HANARO (Hi-flux Advanced Neutron Application ReactOr), has been constructed with the open-pool, the core is submerged in, for the multi-purpose neutron application. The reactor has a primary cooling system to remove the fission heat from the core and its connected fluidic systems. Since the works are required at the reactor pool top as a characteristic of the research reactor, the radiation shall be minimized with the operation of the hot water layer system to avoid unnecessary radiation exposure on the workers during work at the pool top. Moreover, the pool water management system is connected to the reactor pool to maintain the pool temperature below $50^{\circ}C$ to minimize the uprising radioactive gas or impurity from the colder pool bottom. For the efficient flow rate of the PWMS, the thermal capacity of heat exchanger is selected with 260 kW in the normal operation condition. In this paper, the modeling is formulated to figure out whether or not each pool temperature maintains below the temperature limit and the calculation results show that the designed PWMS heat exchanger has enough capacity with the design margin regardless of the reactor operation mode.

Linear Stability of Variable-Viscosity Fluid Layer under Convection Boundary Condition (대류 조건하의 가변 점성 유체층의 선형 안전성)

  • 송태호
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.1
    • /
    • pp.132-141
    • /
    • 1992
  • The critical condition for onset of Benard convection with variable viscosity .nu.=.nu.$_{0}$exp(-CT) has been obtained using a linear stability theory. The bottom wall is rigid while the upper surface may be either free or rigid. The two boundaries are subject to convective heat transfer. The critical Rayleigh numbers are presented up to maximum viscosity ratio of 3000. It is greater for smaller upper and/or lower surface Biot numbers. Its dependence on the viscosity ratio is complicated. However, a simple sublayer theory is found to be applicable for extremely large viscosity ratio. In such cases, the critical Rayleigh number and the critical wave number are functions of viscosity ratio and lower surface Biot number.r.

Development of Casting Furnace for Directional Solidification Ingot (잉곳의 방향성 응고를 위한 주조 로 개발)

  • Ju, Jin-Young;Lee, Seung-Jun;Baek, Ha-Ni;Oh, Hun;Cho, Hyun-Seob;Lee, Choong-Hun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.2
    • /
    • pp.808-816
    • /
    • 2012
  • This paper is the study for the directional solidification of the ingot through the thermal analysis simulation and structural change of casting furnace. With the results of thermal analysis simulation, the silicon as a whole has reached the melting temperature as the retention time 80 min. The best cooling conditions showed at the upper cooling temperature $1,400^{\circ}C$ and cooling time 60min. The fabricated wafers showed the superior etching result at the grain boundary than that of existing commercial wafers. The FTIR measurements of oxygen and carbon impurities were not in the critical value for solar conversion efficiency. The NAA analysis of metal impurities were also detected the total number of 18 different metals, but the concentration distribution showed no significant positional deviations in the same position from the top to the bottom.

Estimation of Directional Solidification Ingot with Heating Position (발열 위치에 따른 잉곳의 방향성 응고 평가)

  • Jun, Ho-Ik;Cho, Hyun-Seob
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.4
    • /
    • pp.1915-1920
    • /
    • 2013
  • This paper is the study for the directional solidification of the ingot through the thermal analysis simulation and structural change of casting furnace. With the results of thermal analysis simulation, the silicon as a whole has reached the melting temperature as the retention time 80 min. The best cooling conditions showed at the upper cooling temperature $1,400^{\circ}C$ and cooling time 60min. The fabricated wafers showed the superior etching result at the grain boundary than that of existing commercial wafers. The FTIR measurements of oxygen and carbon impurities were not in the critical value for solar conversion efficiency. The NAA analysis of metal impurities were also detected the total number of 18 different metals, but the concentration distribution showed no significant positional deviations in the same position from the top to the bottom.

Structural Design of 3D Printer Nozzle with Superior Heat Dissipation Characteristics for Deposition of Materials with High Melting Point (고 용융점 소재의 압출적층성형을 위한 우수한 방열특성을 갖는 3차원 프린터 nozzle부 기구설계)

  • Kim, Wan-Chin;Lee, Sang-Wook
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.15 no.2
    • /
    • pp.313-318
    • /
    • 2020
  • Since the engineering plastics having a melting point of higher than 300 degrees have a high mechanical rigidity, chemical resistance, friction and abrasion performance, those are being highlighted as metal replacement materials in various industries. In this study, 3D printer nozzle with excellent heat dissipation characteristics are designed and analytically verified to form engineering plastics with high melting points in 3D printers based on the melt-lamination modeling method. In order to insulate between the heat block heated to a melting point of filament material and the upper part of the nozzle where the filament is transferred, the heat brake part with low thermal conductivity was designed to have two separate parts, and a cooling fin structure is further applied to the heat brake part to lower steady-state temperature by air convection. Optimized structural design on FDM nozzle part reduces the temperature at the heat sink and at the end part of heat brake by 50% and 14% respectively, compared to the conventional BCnozzle structure.

CHIME Zircon Age of the Gamaksan Alkaline Meta-Granitoid in the Northwestern Margin of the Gyeonggi Massif, Korea, and its Tectonic Implications (경기육괴 북서 연변부 감악산 알칼리 변성화강질암의 CHIME 저어콘 연대와 지체구조적 의의)

  • Cho, Deung-Lyong;Lee, Seung-Ryeol;Suzuki, Kazuhiro
    • The Journal of the Petrological Society of Korea
    • /
    • v.16 no.3
    • /
    • pp.180-188
    • /
    • 2007
  • We carried on CHIME zircon age dating for the Gamaksan alkaline meta-granitoid (GAM) from the northwestern margin of the Gyeonggi massif, and obtained a timing of regional metamorphism at $247{\pm}14Ma$ (n=103, MSWD=0.92). The age is compatible with Permo-Triassic regional metamorphic ages from the Imjingang Belt which has been regarded as possible eastward extension of Triassic collisional belt in China. Considering an extensional ductile shearing of the Gyeonggi (Kyonggi) Shear Zone which deformed GAM occurred at 226 Ma with temperature condition about $500^{\circ}C$ (Kim et al., 2000), and the Late Triassic to Early Jurassic Daedong Group unconformably overlies on top of the ductile shear zone, cooling rate of GAM over the period can be estimated as $18{\sim}10^{\circ}C/Ma$. Since new zircon begin to pow at temperature higher than upper-amphibolite facies condition (${\sim}700^{\circ}C$), cooling rate of GAM from peak metamorphism (247 Ma) to deposition of the Daedong G.oup (${\sim}$Early Jurassic) would be higher than $10^{\circ}C/Ma$. Such rapid cooling rate is compatible with that reported from exhumation stage of the Dabie-Sulu Belt, and supports an idea that the Gyeonngi massif is a part of Permo-Triassic orogenic belt in East Asia.

Heat Transfer Characteristics for Inward Solidification in a Horizontal Cylinder Packed with P.C.M. (상변화물질을 충전한 수평원통관 내에서 응고시 열전달특성)

  • Yum, Sung-Bae;Hong, Chang-Shik;Lee, Chai-Sung
    • Solar Energy
    • /
    • v.11 no.2
    • /
    • pp.51-62
    • /
    • 1991
  • Heat transfer characteristics for heat retrieving processes in a paraffin-filled horizontal circular cylinder was studied. Theoretical and experimental analyses were carried out. In the theoretical analysis, solid and liquid phases were treated separately. Namely, convection for liquid and conduction for solid phase were investigated respectively. The retrieved heat was calculated from the experimentally determined solidified mass. Furthermore, the effects of initial temperature of the liquid and cooling temperature on the heat discharge rate were also studied. In the heat retrieving process, the governing factor for the solidifying rate is the cooling temperature, because most of the liquid sensible heat is rapidly discharged in the initial stage of solidification. Hence heat transfer mechanism during heat retrieving process can be safely considered as conduction. In the cut of frozen paraffin, there showed an empty space in the upper region. It is caused by the temperature drop in the liquid paraffin. While volume shrinkage caused by phase transition was indiscernible. Irrespective of cooling temperature and initial liquid temperature, solidified mass was well-correlated with the product of Fourier number and Stefan number in the solid phase.

  • PDF