• Title/Summary/Keyword: 상부구조 질량

Search Result 43, Processing Time 0.024 seconds

A Study on the Influence of a supporting structure on the Seismic Response of a Roof Structure (하부구조가 지붕구조의 지진응답에 미치는 영향에 관한 연구)

  • Jung, Chan-Woo;Kang, Joo-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.7 no.2 s.24
    • /
    • pp.63-74
    • /
    • 2007
  • Large spatial structures consist of roof structure and its supporting structure. Authors simply call the supporting structure "lower parts" and roof structure "upper parts". To study the influence of an lower part on the seismic response of the upper part of a structure as a first step, authors substitute the upper part and the lower part of the structure to a single degree of freedom system individually, and set up a new 2 DOF structural model connected by them. It is clarified that the mass ratio and the period ratio of an upper part to a lower part are important parameters to find the amplification or reduction of the seismic response of an upper part.

  • PDF

Experimental Study on Natural Period for Arch Structure with Column (하부기둥에 따른 아치구조물의 고유주기 변화에 관한 실험적 연구)

  • Kang, Joo-Won;Seok, Keun-Yung;Lee, Sang-Hoon;Kim, Gee-Cheol
    • Journal of Korean Association for Spatial Structures
    • /
    • v.9 no.2
    • /
    • pp.83-90
    • /
    • 2009
  • The previous studies for dynamic behavior of spatial structure have been zoomed in on roof structure by numerical analytic method. But the roof structure of real spatial structures is supported by lower structure as column and wall. So, when earthquake is occurred, it is predicted that dynamic behavior of roof structure is affected by lower structure. Therefore, on this study, natural period characteristics of arch structures are analyzed according to section, length and the modulus of elasticity of brass column and polycarbonate column and additional mass of roof structure by the scale-down model of arch structure as the most simple structure of spatial structures. The changes of natural periods are generally alike. But, when Polycarbonate column is connected to roof structure, the change of natural period for change of section is relatively large. That means that change of section and section and length of column and additional mass of roof structure have less influence on change of stiffness because the modulus of elasticity of brass is relatively large.

  • PDF

Analysis of Natural Frequency Change of Pier According to Bridge Superstructure Modeling Methods (교량 상부구조물의 모델링 방법에 따른 교각 고유진동수 변화분석)

  • Park, Byung-Cheol;Chang, Sung-Hee;Kim, Young-Hoon
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2010.04a
    • /
    • pp.187-190
    • /
    • 2010
  • 기초세굴에 따른 교각에서의 1차 모드 고유진동수 변화를 이용하여 교량 세굴 건전성을 정량적으로 평가하기 위하여 공용중인 광탄1교의 T형 교각 1기에 대하여 충격진동실험을 수행하였으며, 교축직각방향의 1차 모드 고유진동수를 수치해석결과와 비교하였다. 교량 상부구조물의 모델링 방법에 따라 상부구조물을 전체 모델링한 방법과 교각만을 모델링하고 상부구조물의 영향범위를 가정하여 교량받침 위치에 질점질량으로 변환하여 적용한 방법으로 구분하여 수치해석을 수행하였다. 상부구조물을 전체 모델링한 경우와 집중하중 형태로 상부구조물을 모델링한 경우 모두 고유진동수는 충격진동실험결과와 큰 차이를 보였다. 충격진동실험을 통해 얻은 고유진동수는 교각의 국부적인 진동수로 사료되는 반면, 수치해석을 통해 구한 결과는 교량 상부와 하부의 Coupling 효과가 반영된 시스템 전체의 고유진동수이기 때문에 결과의 큰 편차가 생기는 것으로 판단된다. 따라서 충격진동실험에서 구한 고유치 양상을 올바로 구현하기 위한 모델링을 찾기 위해서는 새로운 접근 방법이 필요할 것으로 사료된다.

  • PDF

Response Analysis of RC Bridge Pier with Various Superstructure Mass under Near-Fault Ground Motion (근단층지반운동에 대한 상부구조 질량 변화에 따른 RC 교각의 응답분석)

  • Park, Chang-Kyu;Chung, Young-Soo;Lee, Dae-Hyung
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.5
    • /
    • pp.667-673
    • /
    • 2010
  • The near fault ground motion (NFGM) is characterized by a single long period velocity pulse with large magnitude. NFGMs have been observed in recent strong earthquakes, Northridge (1994), Japan Kobe (1995), Turkey Izmit (1999), China Sichuan (2008), Haiti (2010) etc. These strong earthquakes have caused considerable damage to infrastructures because the epicenter was close to the urban area, called as NFGM. Extensive research for the far field ground motion (FFGM) have been carried out in strong seismic region, but limited research have been done for NFGM in low or moderate seismic regions because of very few records. The purpose of this research is to investigate and analyze the seismic response of reinforced concrete bridge piers subjected to near-fault ground motions. The seismic performance of six RC bridge piers depending on three confinement steel ratios and three superstructure mass was investigated on the shaking table. From these experimental results, it was confirmed that the reduction of seismic performance was observed for test specimens with lower confinement steel ratio or more deck weight. The displacement ductility of RC bridge piers in terms of the stiffness degradation is proposed based on test results the shaking table.

The Response Characteristics of Push-over and Nonlinear Time History Analysis with Variations in the Upper Stories of the Mixed Building Structure (복합구조물의 상부층수 변화에 따른 탄소성 정적 및 동적 응답특성)

  • 강병두;전대한;김재웅
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.5 no.5
    • /
    • pp.73-83
    • /
    • 2001
  • The mass and stiffness of upper wall-lower frame system(mixed building structures) change sharply at transfer floor due to different structural system in upper and lower part. These mixed building structures generally show the stiffness, weight or geometric vertical irregularities. The purpose of this study is to investigate the response characteristics of these structures by push-over analysis and nonlinear time history analysis. For four types of analysed models, only the variation of upper wall stories was considered. The conclusions of this study are following; (1) In the push-over analysis, yielding hinges in beams and columns of lower frame occurred at the base shear of similar magnitude in all models. But as the number of stories of upper wall increases, yielding hinges at ends of coupling beams were observed in the small magnitude of base shear. (2) In the nonlinear time history analysis, yielding of lower frame occurred at beams with as small ground acceleration as 55gal, and in upper walls yielding was concentrated on coupling beams and shear walls near the transfer floor. (3) As the number of stories of upper walls decreases, the story stiffness of the lower frames decreased relatively and the occurrence of soft stories in the lower frame was observed.

  • PDF

Application of Mid-Story Isolation System for Reducing Seismic Response of Space Structure (공간구조물의 지진응답 저감을 위한 중간면진장치의 적용)

  • Kim, Gee-Cheol;Kang, Joo-Won;Kim, Hyung-Man
    • Journal of Korean Association for Spatial Structures
    • /
    • v.9 no.4
    • /
    • pp.97-103
    • /
    • 2009
  • The seismic isolation system reduces the seismic vibration that is transmitted from foundation to upper structure. This seismic isolation system can be classified into base isolation and mid-story isolation by the installation location. In this study, the seismic behavior of arch structure with mid-story isolation is analyzed to verify the effect of seismic isolation. Mid-story isolation is more effective than base isolation to reduce the seismic responses of roof structure. Also, this isolation would be excellent in structural characteristics and construction.

  • PDF

Seismic Isolation Effects Due to the Difference Between the Center of Mass of the Building and the Center of Stiffness of Isolation Layer (건물의 질량중심과 면진층의 강성중심 차이에 따른 면진효과)

  • Hur, Moo-Won;Chun, Young-Soo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.5
    • /
    • pp.107-115
    • /
    • 2014
  • In this study, we examined the seismic isolation effects due to the difference between the center of mass of the building and the center of stiffness of isolation layer. Because the base isolation technique is a technique that is highly dependent on the performance of seismic isolation devices installed on the seismic isolation layer, we have to examine the horizontal stiffness of seismic isolation devices after making them. If difference between the design stiffness and the actual stiffness of the seismic isolation device occurred, a big problem may be generated in the upper members on the seismic isolation layer. The analytical results show that the more eccentricity increases, the more maximum response acceleration, story shear and the member forces of the upper part of the structure increases, and the damage is expected to be in excess. Therefore, it is recommended that if possible, isolation devices have to be designed to coincide the center of mass of the building with the center of stiffness of isolation layer. If not after making isolation devices, they need to be relocated to prevent the eccentricity.

Natural Period Estimation for the Buildings of Upper Wall and Lower Frame Type (상부벽식-하부골조를 가진 복합구조물의 고요주기예측)

  • 박기수;김희철;김종헌
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.4 no.4
    • /
    • pp.1-13
    • /
    • 2000
  • 상부벽식 하부골조를 가진 복합구조물은 부족한 대지를 효율적으로 활용하기 위하여 건설되고 있다. 이러한 복합건물은 상부벽식-하부골조를 가지는 구조로써 일반적으로 전이보 또는 전이판으로 상하부를 연결하고 있다. 따라서 상하부 구조사이의 강성과 질량에 많은 차이가 발생하게 된다. 구보물의 고유주기는 지진하중과 밑면전단력을 결정하기 위한 중요한 변수이다. 그러나 현재 국내 규준에서 제안하는 고유주기 산정식은 이러한 건물에는 적용할 수 없다. 본 연구에서는 상부벽식-하부골조를 가진 복합구조물의 고유주기의 산정에 영향을 미치는 변수들 중 가장 큰 영향을 미치는 건물의 상하부 층수에 따른 변수만을 고려하여 고유주기산정식을 제안하였다. 하부는 2~5개 층을 가지고, 상부는 10~18개 층을 가지는 15~20층의 건물이면 정형적인 평면을 가지는 복합구조물로 한정하였다. 건물 내부의 채움벽에 대한 효과를 고려한 고유주기 제안식은 다음과 같다. 장변 방향 : $T_{L}$=($0.20H_{h}+0.05H_{i}$)/$sqrt{B}$-0.42 단변 방향 :$T_{S}$=($0.07H_{h}+0.12H_{i}$)/$sqrt{B}$-0.40

  • PDF

2-D Dynamic analysis method of base-isolated pool structure (면진수조의 2차원 동적 해석기법 개발)

  • 전영선;최인걸;김진웅
    • Computational Structural Engineering
    • /
    • v.8 no.3
    • /
    • pp.67-74
    • /
    • 1995
  • This study develops 2-D analysis method of a base-isolated pool structure, and verifies the method through shaking table test using a scaled model. A wall of the pool structure is modeled as lumped mass, and added mass of the fluid is imposed on the nodes of the structure to consider the hydrodynamic effect of contained fluid. The equation of motion of base-isolated pool structure is obtained by coupling of two equations for superstructure composed of wall and fluid, and for bottom slab and isolator. The scaled model for shaking table test is made with transparent acryle, and 4-high damping laminated rubber bearings are used. The responses of the scaled model by the test are generally good agreement with those by the analysis. It is shown that 2-D analysis method gives somewhat conservative results.

  • PDF

Design of CFRP-Metal Hybrid Pantograph Upper-arm (탄소섬유 복합재료-금속 하이브리드 팬터그래프 상부암 설계)

  • Jeon, Seung-Woo;Han, Min-Gu;Chang, Seung-Hwan;Cho, Yong-Hyeon;Park, Chul-min
    • Composites Research
    • /
    • v.28 no.5
    • /
    • pp.327-332
    • /
    • 2015
  • In this research, a parametric study was carried out to design a metal-carbon fiber reinforced plastics (CFRP) hybrid pantograph for weight reduction of high speed train (KTX). To design a light-weight and high-stiffness pantograph, some parts of the original steel upper arm was replaced by CFRPs with appropriate stacking sequences. For the parametric study, steel was replaced by aluminium considering structure stiffness and weight of hybrid upperarm of a pantograph. Finite element analysis (FEA) was performed for checking the structure stiffness with varying design parameters. Static vertical load stiffness and weight changing ratio were derived from real CX-PG pantograph model analyses. From the FEA results, the geometries of high-stiffness, light-weight pantograph have been suggested.