• Title/Summary/Keyword: 상대 습도

Search Result 992, Processing Time 0.031 seconds

A Study on the Change of Humidity by City Size in South Korea (한국의 도시 규모별 습도 변화에 관한 연구)

  • Ko, Myungchan;Lee, Seungho
    • Journal of the Korean Geographical Society
    • /
    • v.48 no.1
    • /
    • pp.19-36
    • /
    • 2013
  • This study aimed to investigate the change of humidity by city size in South Korea. Using daily mean relative humidity and water vapor pressure during the period of 1954~2011 for 14 weather stations in South Korea, the change of humidity by city size was analyzed. The change of relative humidity had a continuous decreasing trend for the period of 1954~2011. The decreasing trend in large city was bigger than these of rural one. The seasonal relative humidity was significantly changed in spring and winter. The change of water vapor pressure was rarely changed significance of the results by city size. It was not shown the result to constant trend by city size. There was a negative correlation between relative humidity and mean temperature. And change of relative humidity was correlated with city size. Moreover, there was not correlation between relative humidity and water vapor pressure by city size. The decreasing trend of relative humidity was similar to increasing trend of temperature by urbanization. However, there was not shown significant result of water vapor pressure.

  • PDF

Desorption EMC/ERH of Soybean (콩의 탈습 평형함수율/평형상대습도)

  • Choi, Byoung-Min
    • Food Science and Preservation
    • /
    • v.15 no.1
    • /
    • pp.74-78
    • /
    • 2008
  • Desorption experiments were carried out on soybean (Taegwang) at 5, 15, 25, 35, $45^{\circ}C$ for moisture contents between 6.74 and 28.87%(db). The method employed was to measure the equilibrium relative humidity (ERH) of air in contact with the grain under static conditions, using an electronic hygrometer. The effects of temperature and moisture contents were investigated, and the measured values were fitted to the modified Henderson, the modified Chung-Pfost, the modified Halsey, the modified Oswin and the modified GAB model. The ERHs of soybean under the moiture content of 16.67%(db) decreased with an decrease in moisture content and temperature, but the ERH of the moisture content of 28.87%(db) material decreased with an increase of temperature. The modified GAB model was the best in describing the EMC/ERH of soybean.

Effect of Scindapsus aureus and Syngonium podophyllum on the Improvement in Indoor Humidity by a Difference of Hydoroculture Volume Ratio and Pot Media (하이드로컬쳐 부피비와 화분용토에 따른 스킨답서스, 싱고늄의 실내습도 개선효과)

  • Ju, Jin-Hee
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.37 no.4
    • /
    • pp.94-99
    • /
    • 2009
  • The purpose of this study was to utilize hydroculture by the vital means of the improvement of indoor relative humidity. This experiment employed a search of the effect of Scindapsus aureus and Syngonium podophyllum that are generalized for hydroculture foliage plant by a difference of volume ratio, pot media and plants species. In the case of Scindapsus aureus, relative humidity was high for growth chamber in which plants presented as opposed to control growth chambers in which there were no plants. Although relative humidity was 25% in control chamber, there was an increase of 40% at a 2% volume ratio, 45% at a 3% volume ratio and 50% at a 5% volume ratio. The relative humidity of Syngonium podophyllum was 40% at a 2% volume ratio, 44% at a 3% volume ratio and 46% at a 5% volume ratio, while the control treatment was 25% relative humidity in hydroculture. Both the control treatment and hydroball pot in a hydroball container were high at first. As time progressed, artificial soil pots in water containers was similar when housed within the control chamber by about 45% relative humidity. Hydroball pots in water container had about 30% relative humidity. Ardisia pusilla of hydroball poIt in hydroball container had about 38% relative humidity.

Effect of Humidity and Flooding on the Performance of Proton Exchange Membrane Fuel Cell (고분자전해질 연료전지의 성능에 미치는 습도와 플러딩의 영향)

  • Hwang, Byungchan;Chung, Hoi-Bum;Song, Myung-Hyun;Oh, Sung-June;Na, Il-Chai;Park, Kwonpil
    • Korean Chemical Engineering Research
    • /
    • v.55 no.3
    • /
    • pp.302-306
    • /
    • 2017
  • Humidity affect performance and durability of proton exchange membrane fuel cell (PEMFC). High humidity of gases generally enhance the performance, but high humidity have the danger of flooding. I-V performance, linear sweep voltammetry, cyclo voltammetry, and impedance of micro-channel cell measured with change of relative humidity (RH). Flooding phenomena started at RH 70%. Ion conductivity of membrane reached maximum value at RH 80%. Maximum current density of $1,700mA/cm^2$ (at 0.6 V) was obtained at RH 80%. Therefore the effect of ion conductivity increasement was higher than that of mass transfer decrease by flooding at RH 80%.

Characteristics of fruit body of Neolentinus lepideus according to relative humidity (상대습도에 따른 잣버섯의 생육형태)

  • Jang, Myoung-Jun
    • Journal of Mushroom
    • /
    • v.12 no.4
    • /
    • pp.363-366
    • /
    • 2014
  • This study was focused on finding a relationship between fruit-body growth and relative humidity in Neolentinus lepideus cultivation. The higher the relative humidity, the moisture content of pileus and stipe were also tends to be increased. The day of formation of primordia and development of fruit body was shortest at the relative humidity 95%. The yield and commercial yield were higher in the relative humidity 95% than in the other treatment. Individual weight of fruit body was the highest at the relative humidity 75% and 85%. Crack indices of pileus was the strongest at the relative humidity 65%.

Effect of Relative Humidities on the Qualities of White Ginseng during Storage -II. On the Changes of Saponins and Sugars- (저장상대습도(貯藏相對濕度)가 백삼품질(白蔘品質)에 미치는 영향(影響) -제2보(第2報) : Saponin 및 당(糖)의 변화(變化)-)

  • Noh, Hye-Won;Do, Jae-Ho;Kim, Sang-Dal;Oh, Hoon-Il
    • Korean Journal of Food Science and Technology
    • /
    • v.15 no.1
    • /
    • pp.32-36
    • /
    • 1983
  • The contents of ginseng saponins in white ginseng, particularly ginsenoside $-Rb_1$, -Rc, -Re, and -Rg, were greatly decreased during the storage at high relative humidities. The contents of glucose and fructose were initially increased and thereafter decreased during the storage at 75-96% R.H., but successively increased during the storage at relative humidifies below 67%. The content of sucrose was decreased during storage of white ginseng and the rate of change was accelerated at the relative humidities higher than 75% R.H..

  • PDF

Variation of surface humidity across South Korea over the last century (지난 한 세기 동안 우리나라 지표면 습도의 변화)

  • Lee, Jisoo;Kang, Dongwoon;Paik, Kyungrock
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.164-164
    • /
    • 2022
  • 대기의 습한 정도는 기상 현상과 밀접한 관계를 가진다. 공기가 건조하면 가뭄이나 산불이, 반대로 습윤하면 홍수나 극한 강우가 내리기 쉽다. 산업화 이후 지구의 평균 기온이 상승하면서, 세계적으로 상대습도가 감소하는 경향성이 보고되고 있다. 이러한 경향이 우리나라에서도 확인되는지 파악하고자, 이 연구에서는 장기간에 걸친 상대습도 관측치가 존재하는 종관기상관측소 6개소의 자료를 분석하였다. 기온은 시간에 따라 증가하고, 포화 수증기압도 그에 따라 증가해온 것으로 나타났다. 하지만, 상대습도의 증감은 포화 수증기압뿐만 아니라 실제 수증기압의 변화에도 민감하게 반응한다. 우리는 실제 수증기압 변화의 원인을 수증기압에 영향을 주는 다양한 기후 변수들의 시계열 자료를 통해 분석해보았다. 우리나라 지역별로 상당한 변동성이 나타났는데, 대표적으로 동해안과 서해안 사이의 차이, 내륙과 해안의 차이에 대해 자세히 발표할 것이다.

  • PDF

The Assessments of Integrity of SA516 Gr.70 Material for the 60 days Exposure in over 40% Relative Humidity Environments (상대습도 40%이상 환경에서 SA516 Gr.70 재료의 장기간 노출에 따른 건전성 평가)

  • Gwon, Hyeok-Cheol;Lee, Du-Ho;Seong, Gi-Bang
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2014.11a
    • /
    • pp.193-194
    • /
    • 2014
  • 원전은 고온기능시험 이후 2차계통 내부를 상대습도 40%이하로 관리하여 계통 재질 부식을 최소화하고 있다. 일반적으로 발전소에서는 운전 정지 후 상대습도 40%이하로 낮추는데 15일정도 소요되지만, 발전소 계통 중 일부 곡관부위는 약 60일정도 소요된다. 본 연구는 일부 계통 재료가 상대습도 제한치(<40%) 이상의 환경에서 장기간(최대 60일) 노출시 재료 건전성에 미치는 영향 평가이다. 평가를 위해 시편의 실험 전, 후 무게변화를 이용한 부식률 측정과 표면분석을 위해 광학현미경을 이용하였다. 사용 시편의 재료는 SA516 Gr.70이며 표면상태를 인위적으로 산화피막을 생성 시킨 것(2개)과 산화피막이 없는 것(6개)으로 2종류로 제작하였다. 총 시험기간은 60일이고 시험기간 중 산화피막이 없는 시편은 7일, 21일, 60일에 시편을 2개씩 꺼내어 무게를 측정하여 부식률을 계산하였다. 실험결과, 산화피막이 없는 시편은 노출되는 시간에 따라 부식률이 각각 0.35(7일), 0.21(21일), 0.67(60일) mpy이었고 산화피막이 있는 시편은 0.06(60일) mpy였다. 산화표면 분석결과, 산화피막이 없는 시편은 노출되는 시간에 관계없이 물방울이 맺힌 부분에 pitting을 확인하였다. 하지만, 산화피막이 있는 시편은 pitting의 흔적은 없었다. 산화피막이 없는 시편의 경우 시간에 따라 부식률은 높아지지만 학계에서 통용되는 뛰어난 내부식성 재료의 부식률 기준인 < 1 mpy이하기 때문에 재료 건전성에 미치는 영향은 거의 없을 것으로 판단된다. 또한, 대부분 원전의 경우 고온기능시험 또는 운전기간 동안에 2차계통 구성 재료 표면에 산화막이 생성되었기 때문에 산화피막이 있는 시편의 결과로 판단하면 상대습도 40%이상에 60일 이상 노출되어도 부식은 거의 일어나지 않았을 것으로 사료된다. 실증실험결과를 가지고 종합적으로 평가하면 상대습도 40%이상 환경에서 곡관부위가 60일이상 노출되어도 재료 건전성에 미치는 영향은 거의 없을 것으로 판단된다.

  • PDF

Cooling Fluid Study in Proton Exchange Membrane Fuel Cell (고분자전해질형 연료전지의 냉각유체에 대한 연구)

  • 김준범;이흥주
    • 한국전기화학회:학술대회논문집
    • /
    • 2005.07a
    • /
    • pp.93-96
    • /
    • 2005
  • 고분자전해질형 연료전지에서는 수소이온의 이온전도성 저하를 방지하기 위하여 외부에서 가습하여 주는 방식이 일반적이지만, 가습에 소요되는 부품을 일부라도 제거할 경우 연료전지의 효율은 높이고 제작단가도 경감할 수 있다. 이를 위하여 저가습 및 무가습 실험을 수행하였으며, 정확한 data의 수집과 시험장비의 자동제어를 위하여 National Instrument사의 compact field point (cFP)를 사용하였다. Humidifier와 heater의 온도를 조절하여 공급유체의 상대습도 및 온도를 각각 조절하였으며, 이에 필요한 이론적 온도는 Antoine equation 을 사용하여 산정하였다. Anode와 cathode 양측 $100\%$ 가습 경우를 기준으로 가습량을 조절하면서 실험을 수행하였으며 성능 차이를 그래프로 도시하여 양측의 변화에 대한 영향을 볼수 있도록 하였다. Stack의 온도가 $70^{\circ}C$이고 양측 무가습일 경우에 성능 측정이 어려워서 stack의 온도를 저온에서부터 변화시키면서 무가습 성능을 실시간으로 측정하여 보았다. 일반적으로 hydronium ion은 anode측에서 cathode측으로 계속 이동하여야 전기를 생성할 수 있으므로 cathode측 무가습이 anode측 무가습보다 성능이 더 잘 나오는 것으로 예측하였으나 이와 반대되는 경향의 실험 결과를 얻었다. 양측 무가습의 경우에는 공기 중의 상대습도와 back diffusion 등에 영향을 받을 수 있으므로 각종 변수들의 영향을 분리하여 관찰할 수 있는 실험을 수행 중에 있다.

  • PDF

Temperature and Humidity Aging Characteristics of Composite Solid Propellant (혼합형 고체 추진제 온$cdot$습도 노화 특성)

  • Lee Kyung-Joo
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.9 no.2
    • /
    • pp.46-53
    • /
    • 2005
  • We have analyzed the temperature and humidity aging test results of a composite solid propellant. The temperature aging test was performed to evaluate the storage life of a propellant, while the humidity aging test could provide the hygroscopicity of Ammonium Perchlorate(AP) exposed to .elative humidity (RH) 10, 30, $50\%$ environment. A specimen was used in the temperature test, and a block of propellant from the actual motor was used in the humidity test. We report that the 4-month storing at 60 degree is equivalent to the 10-year 60 degree condition. The composite solid propellant with HTPB binder showed signs of hardening with time lapse but the effect of humidity up to RH $50\%$ was not noticeable.