• Title/Summary/Keyword: 상단

Search Result 1,100, Processing Time 0.03 seconds

Bandwidth Redistribution Based Fairness Control Method for the IEEE 802.17 Resilient Packet Ring (IEEE 802.17 레질런트 패킷링을 위한 대역폭 재분배 기반 공정성 제어 방식)

  • Kim, Tae-Joon;Kim, Hwang-Rae
    • Journal of Korea Multimedia Society
    • /
    • v.9 no.7
    • /
    • pp.844-853
    • /
    • 2006
  • The IEEE 802.17 Resilient Packet Ring (RPR) for future Local, Metropolitan, and Wide Area Networks was recently standardized, but it still suffer from delay jitter deterioration and even some bandwidth loss under unbalanced overload. In order to overcome these drawbacks, this paper proposes a bandwidth redistribution based fairness control method, compatible with the legacy one, in which each congested node measures the amount of available bandwidth of its bottleneck link resulted from regulating upstream nodes' shares of the link bandwidth, calculates optimal fair rate with the number of uptream nodes requiring more bandwidth, and then redistributes the available bandwidth to the upstream nodes by advertising the rate. The performance evaluation results show that the proposed method fairly redistributes 95% of the bottleneck link bandwidth with even only two redistributions.

  • PDF

Effects of Corner Radius on the Stress Strength Safety of LPG Steel Cylinder (LPG 강재용기의 응력강도 안전성에 미치는 코너반경의 영향)

  • Kim, Chung Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.1
    • /
    • pp.18-22
    • /
    • 2015
  • This paper presents the stress strength safety of LPG steel cylinder for various corner radiuses of upper round end plate and lower round end plate by using a finite element method. The FEM analyzed results indicate that the most influential elements is a corner radius of upper round end plate and lower round end plate rather than a thickness of LPG cylinder. But, the thickness of a steel cylinder is an important design element considering for a weight reduction of a cylinder. Thus, this paper recommends that the LPG steel cylinder thickness is 2.3~2.6mm and the corner radius of upper round end plate and lower round end plate is over 157mm as an optimum design for the maximum testing pressure of 3.04MPa.

Study of an Explicit Guidance Algorithm Applicable for Upper Stages of Space Launch Vehicles (발사체 상단의 외연적 유도 알고리듬 적용 연구)

  • Song, Eun-Jung;Cho, Sang-Bum;Park, Chang-Su;Roh, Woong-Rae
    • Aerospace Engineering and Technology
    • /
    • v.10 no.1
    • /
    • pp.89-97
    • /
    • 2011
  • This paper considers improved IGM (Iterative Guidance Mode), one of the explicit guidance algorithms, to determine the guidance algorithm for upper stages of a space launch vehicle. IGM, which has been employed successfully for the Saturn to put its payload into the parking orbit and lunar transfer orbit, is applied here for guidance of the launcher during the second and third stages. The orbit injection accuracy is evaluated through the 3-DOF computer simulations and an accurate prediction method, which can eliminate the prediction error of the downrange position at the orbit injection, is also proposed here.

A Study on the Risk Assessment and Mitigation Plan about Fire Explosion of n-Pentane in EPS Process (EPS공정에서 발생하는 n-Pentane의 화재폭발에 대한 위험성평가 및 위험성 완화 대책에 관한 연구)

  • Seo, Min Su;Kim, Ki Sug;Kim, Bo Min;Kang, Dong Cheon;Kang, Kil Jae;Chon, Young Woo
    • Korean Journal of Hazardous Materials
    • /
    • v.6 no.2
    • /
    • pp.39-46
    • /
    • 2018
  • 최근 전자제품 생산업체에서 EPS를 직접생산하게 되면서 EPS 공정이 증가하고 있다. EPS에는 펜탄이 포함되어 있으며, 펜탄은 하이브리드 혼합물로 구분할 수 있어 높은 화재폭발의 위험성을 가지고 있다. 각 공정별 펜탄의 누출률은 발포기, 사일로실, 저장실 순이나 발포기의 경우 일반적으로 밀폐되어 있으므로 사일로 실이 가장 화재폭발 위험성이 높다고 판단하였다. 사일로실의 누출률 중 70%는 사일로 상단을 통해 누출되며, 사일로 상단을 통해 누출되는 펜탄의 거동을 분석하여 사일로실 위험성 완화대책을 수립하였다. 1. 폭발위험구역 2종으로 관리, 2. 사일로상단 50cm이내 환기설비 설치 또는 Push-Pull 구조의 환기설비설치, 3. 사일로 하단 1.4m이내에 가스감지기 설치, 4. 60%이상의 습도유지

Quantitative Evaluation of Image Quality using Automatic Exposure Control & Sensitivity in the Digital Chest Image (디지털 흉부영상에서 자동노출제어 및 감도변화를 이용한 영상품질의 정량적인 평가)

  • Lee, Jin-Soo;Ko, Seong-Jin;Kang, Se-Sik;Kim, Jung-Hoon;Kim, Dong-Hyun;Kim, Changsoo
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.8
    • /
    • pp.275-283
    • /
    • 2013
  • The patient radiation dose is different depending on selection of Ion chamber when taking Chest PA which using AEC. In this paper, we studied acquiring the best diagnostic images according to selection of Ion chamber on AEC mode as well as minimizing patient radiation dose. Experimental methods were selection of Ion chamber and change of sensitivity under the same conditions as Chest PA projection. At AEC mode, two upper ion chambers sensors and one lower ion chamber sensor were divided into 7 cases according to selection of on/off. after measuring five times respectively, we obtained average value and calculated exposure dose. Image assessment was done with measured Modulation Transfer Function, Peak Signal to Noise Ratio, Root Mean Square, Signal to Noise Ratio, Contrast to Noise Ratio, Mean to Standard deviation Ratio respectively. In exposure assessment results, selection of two upper chambers was the lowest. In resolution assessment results, image of two upper chambers had the second high spatial frequency at sensitivity at 625(High) was 1.343 lp/mm. RMS value of image selecting two upper chambers was low secondly. SNR, CNR, MSR were the high value secondly. As the sensitivity was increased, radiation dose was decreased but better image could be obtained on image quality. In order to obtain the best medical images while minimizing the dose, usage of two upper ion chambers is considered to be clinically useful at sensitivity 625(High).

Reversely Zoned Compositional Variations and their Origins of the Andong Pluton, Andong Batholith, Korea (안동심성암체의 역누대 초성변화와 그 성인)

  • 황상구;이보현
    • Economic and Environmental Geology
    • /
    • v.35 no.1
    • /
    • pp.75-95
    • /
    • 2002
  • The Andong pluton in the Andong Batholith is composed of comagmatic plutonic rocks, in which the lithofacies comprise hornblende biotite tonalite in the central paft biotite granodiorite in the marginal paft and porphyritic biotite granite at the topside (noJthea~tern paft) of the pluton. The pluton is petrographically and petrochemically zoned, having more mafic center than margin and topside. Distribution pallern of the lithofacies represents a reverse zoning in the pluton. Modal and chemical data in the pluton show progressive and gradual compositional variations from the centrer via the margin to the topside. Quartz and K-teldspar increase toward the topside of the pluton, whereas hornblende, biotite and color index increase toward the center. The bulk composition in the pluton is also reversely zoned, with high $Si0_2$ and $K_{2}O$ in the topside facies, and high MnO, CaO, $Ti0_2$, $Fe_{2}O_{3}$t, MgO and $P_{2}O_{5}$ in the central facies. The reverse zoning is also evident in higher Cr. V, Ni, Sc and Sr of the more mafic tonalite in the interior. The reversely zoned pluton results from remobilization (resurgence) of the lower more mafic compositional zone into the upper more felsic zones of the pluton modified by thennogravitational diffusion and fractional crystallization. In the initial stages of evolution, the pluton was a petrochemical system that fonned chemical compositional zonation with mafic tonalitic magma in the lower. granodioritic one in the middle and granitic one in the upper paft of the magma chamber. Periodic influxes of more mafic magma from the ba~e resulted in mingling of liquids and redistribution of minerals, and may have triggered the remobilil.ation of the lower compositional zone into the upper more felsic zones.

Conceptual Design of a LOX/Methane Rocket Engine for a Small Launcher Upper Stage (소형발사체 상단용 액체메탄 로켓엔진의 개념설계)

  • Kim, Cheulwoong;Lim, Byoungjik;Lee, Junseong;Seo, Daeban;Lim, Seokhee;Lee, Keum-Oh;Lee, Keejoo;Park, Jaesung
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.26 no.4
    • /
    • pp.54-63
    • /
    • 2022
  • A 3-tonf class liquid rocket engine that powers the upper stage of a small launcher and lifts 500 kg payload to 500 km SSO is designed. The small launcher is to utilize the flight-proven technology of the 75-tonf class engine for the first stage. A combination of liquid oxygen and liquid methane has been selected as their cryogenic states can provide an extra boost in specific impulse as well as enable a weight saving via the common dome arrangement. An expander cycle is chosen among others as the low-pressure operation makes it robust and reliable while a specific impulse of over 360 seconds is achievable with the nozzle extension ratio of 120. Key components such as combustion chamber and turbopump are designed for additive manufacturing to a target cost. The engine system provides an evaporated methane for the autogenous pressurization system and the reaction control of the stage. This upper stage propulsion system can be extended to various missions including deep space exploration.

Comparison of Methanotrophic Activity at Top and Bottom Layers in Up-flow Biofilters (상향식 바이오필터에서 상.하층의 메탄 산화 특성 비교)

  • Yun, Jeonghee;Kim, Jung Mi;Kim, Ji Eun;Lee, Daseul;Cho, Kyung-Suk
    • Microbiology and Biotechnology Letters
    • /
    • v.41 no.2
    • /
    • pp.221-227
    • /
    • 2013
  • The methane oxidation characteristics at the top and bottom layers in up-flow biofilters were investigated. Two biofilters were packed with perlite and tobermolite (biofilter A: respectively top and bottom; biofilter B: respectively bottom and top) and then compared. The methane oxidation rate was analyzed with the packed bed of the biofilter layers. The bacterial population in the biofilter was characterized using quantitative real-time PCR. For the methane oxidation rate of the biofilter A column, the perlite top part ($845.16{\pm}64.78{\mu}mol{\cdot}VS^{-1}{\cdot}h^{-1}$) gave a relatively higher value than the tobermolite bottom part ($381.85{\pm}42.00{\mu}mol{\cdot}VS^{-1}{\cdot}h^{-1}$). For the methane oxidation rate of the biofilter B column, the tobermolite top part ($601.25{\pm}37.78{\mu}mol{\cdot}VS^{-1}{\cdot}h^{-1}$) provided a relatively higher value than the perlite bottom part ($411.07{\pm}53.02{\mu}mol{\cdot}VS^{-1}{\cdot}h^{-1}$). The pmoA gene copy numbers, responsible for methanotrophs, in the top layer of biofilter A (1.27E+13 pmoA gene copy number/mg-VSS) was higher than in the bottom layer (3.33E+13 pmoA gene copy number/mg-VSS). However, the population of methanotrophs in biofilter B was not significantly different between the top and bottom layers. These results suggest that although the methane oxidation rates of perlite and tobermolite in the top parts of biofilter A and B were high, methanotroph populations were higher in the bottom parts of both biofilters, with a rapid decline in methane concentrations within the biofilters.