THE LIGHT CURVE ANALYSIS OF AW CAM (AW CAM의 광도곡선 분석)

  • 김천휘;한원용
    • Journal of Astronomy and Space Sciences
    • /
    • v.12 no.1
    • /
    • pp.21-29
    • /
    • 1995
  • The $\beta$ Lyrae-type eclipsing binary AW Cam was observed photoelectrically in three wavelength regions. The obtained UBV light curves of AW Cam were analyzed with two separate modes(mode 2 for detached systems and mode 5 for semi-detached ones) of the Wilson-Devinney binary mode. It is intended to resolve the discrepancy in AW Cam system that the photometrio mass ratio (q=0.21) derived by Russo and Milano (1983) is not consistent with the spectroscopic result (q=0.43) by Mammano et al.(1967). Our photomtric solutions derived with mode 2 are fitted better to the observed light curves than those of mode 5, supporting that AW Cam may be not a normal semi-detached system but a detached one. Three dimensional Roche configuration of AW Cam system calculated with the derived mass ratio (q=0.43) reveals that the less massive secondary with the confined within its inner Roche lobe, while the more massive rimary is in marginally contact. From the Roche geometry, the constancy of the orbital period and other photometric evidences of AW Cam, it is provisionally concluded that the system is an unevolved detached binary in is provisionally concluded that the system is an unevolved detached binary in the phase of case A evolution toward 'contact phase' rather than and evolved one in 'broken-contact phase' suggested by Giuricin and Mardrossian (1981).

  • PDF

THREE DIMENSIONAL FINITE ELEMENT ANALYSIS ON THE MINIMUM CONTACT FRACTION OF BONE-IMPLANT INTERFACE (골조직과 임플랜트 계면의 최소접촉분율에 관한 삼차원 유한요소분석적 연구)

  • Jang, Kyoung-Soo;Kim, Yung-Soo;Kim, Chang-Whe
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.35 no.4
    • /
    • pp.627-646
    • /
    • 1997
  • In order to find the degree of osseointegration at bone-implant interface of clinically successful implants, models including the 3.75mm wide, 10mm long screw type $Br{\aa}nemark$ implant as a standard and cylinder, 15mm long, 5.0mm wide, two splinted implants, and implants installed in various cancellous bone density were designed. Also, the amount of load and material of prostheses were changed. The stress and minimum contact fraction were analyzed on each model using three-dimensional finite element method(I-DEAS and ABAQUS version 5.5). The results of this study were as follows. 1. 10mm long, 3.75mm diameter-screw type implant had $36.5{\sim}43.7%$ of minimum contact fraction. 2. Cylinder type implant showed inferior stress distribution and higher minimum contact fraction than screw type. 3. As implant length was increased, minimum contact fraction was increased a little, however, maximum principal stress was decreased. 4. Implants with a large diameter had lower stress value with slightly higher minimum contact fraction than standard screw type. 5. Two splinted implants showed no change of minimum contact fraction. 6. The higher bone density, the lower stress value. 7. The material of occlusal surface had no effect on the stress of the bone-implant interface.

  • PDF

Analytical and Numerical Investigation of Horizontal Force and Stable Position of Work Roll in Backup-Roll-Drive 4-High Cold-Rolling Mill (보강롤 구동 4 단 냉간압연기에서 작업롤의 수평하중 거동분석과 안정위치 결정을 위한 해석적 및 수치적 고찰)

  • Byon, Sang-Min;Lee, Jae-Hyeon;Park, Heung-Sik
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.9
    • /
    • pp.977-982
    • /
    • 2011
  • The horizontal force acting on a work roll was examined. This force results from the contact force between the work roll and backup roll in a backup-roll-drive 4-high cold-rolling mill. This horizontal force bends the work roll horizontally and therefore exerts reciprocal action on the roll-gap contour. An analytical model for predicting the horizontal force acting on a work roll, which generates a mean value in the steady state, was presented. The material used for the analysis was high-silicon steel (about 3% Si). A three-dimensional finite element (FE) model was also employed to investigate the non-steady-state behavior of the horizontal force. Results showed that the horizontal force varied with the off-center distance between the work roll and backup roll. In addition, the optimal off-center distance was determined to minimize the horizontal force.

Numerical Analysis of Laboratory Heating Experiment on Granite Specimen (화강암의 실내 가열실험에 대한 수치해석적 검토)

  • Dong-Joon, Youn;Changlun, Sun;Li, Zhuang
    • Tunnel and Underground Space
    • /
    • v.32 no.6
    • /
    • pp.558-567
    • /
    • 2022
  • The evolution of temperature and thermal stress in a granite specimen is studied via heating experiment in the context of a high-level radioactive waste repository. A heating condition based on the decay-induced heat is applied to a cubic granite specimen to measure the temperature and stress distributions and their evolution over time. The temperature increases quickly due to heat conduction along the heated surfaces, but a significant amount of thermal energy is also lost through other surfaces due to air convection and conduction into the loading machine. A three-dimensional finite element-based model is used to numerically reproduce the experiment, and the thermo-mechanical coupling behavior and modeling conditions are validated with the comparison to the experimental results. The most crucial factors influencing the heating experiment are analyzed and summarized in this paper for future works.

ANALYSIS OF ER:YAG LASER IRRADIATION ON CUTTING EFFICACY OF ENAMEL AND DENTIN (Er:YAG 레이저의 법랑질 및 상아질의 삭제효과 비교)

  • Hong, Seong-Su;Lee, Sang-Ho;Lee, Chang-Seop;Kim, Su-Gwan
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.4
    • /
    • pp.728-734
    • /
    • 2001
  • The purpose of this study was to investigate the effects of Er:YAG laser on cutting of efficacy of enamel and dentin in primary and permanent teeth. We used the enamel and dentin specimens of human teeth which contain the physiologic saline and maintain the pulpal pressure in dentinal tubules. Each specimen was exposed to Er:YAG laser with non-contact mode under different treatment condition of irradiation energy, pulse repetition rate. We investigated the cutting efficacy of Er:YAG laser by Scanning Intensity Microscopy, and obtained following results. 1. Cutting volume of enamel and dentin in primary and permanent teeth were increased by increasing the irradiation energy, pulse repetition rate. 2. Cutting volume of primary teeth was larger than that of permanent teeth. 3. Cutting volume of dentin was larger than that of enamel in primary and permanent teeth. From these results, Er:YAG laser would be more effective in cutting dentin than enamel, and in cutting primary teeth than permanent teeth for clinical application.

  • PDF

Effect of machining precision of single ceramic restorations on the marginal and internal fit (단일 도재 수복물의 가공 정밀도가 변연 및 내면 적합도에 미치는 영향)

  • Son, Keunbada;Yu, Beom-Young;Lee, Kyu-Bok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.4
    • /
    • pp.313-320
    • /
    • 2020
  • Purpose: The purpose of this study was to evaluate the machining precision and the marginal and internal fit of single restorations fabricated with three types of lithium disilicate ceramic blocks and to evaluate the correlation. Materials and methods: Single restorations were designed using a CAD software program. The crown designed model file was extracted from the CAD software program. Three types of lithium disilicate blocks (Rosetta; HASS, IPS e.max CAD; Ivoclar vivadent, VITA Suprinity; VITA) were milled using a milling machine. For the fabrication of the crown scanned model file, the intaglio surface of the restoration was digitized using a contact scanner. Then, using the three-dimensional inspection software (Geomagic control X; 3D Systems), the process of the overlap of the crown designed model and the scanned model and 3-dimensional analysis was conducted. In addition, the marginal and internal fit of the crowns was evaluated by a silicone replication method. The difference among three types of single ceramic crown was analyzed using a Kruskal-Wallis H test, and Spearman correlation analysis was performed to analyze the correlation between machining precision and fitness (α=.05). Results: There was a significant difference in the machining precision and the marginal and internal fit according to the type of ceramic block (P<.001). In addition, the machining precision and the marginal and internal fit were positively correlated (P<.001). Conclusion: The marginal fit of crowns fabricated according to the types of ceramic blocks was within the clinically acceptable range (< 120 ㎛), so it can be regarded as appropriate machining precision applicable to all clinical as aspects in terms of the marginal fit.

Effect of Implant Length on the Immediate Loading at the Anterior Maxilla (즉시하중시 상악 전치부에 식립된 임플란트 길이 변화에 따른 응력 분포의 삼차원 유한요소 연구)

  • Lee, Joon-Seok;Kim, Myung-Joo;Kwon, Ho-Beom;Lim, Young-Jun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.3
    • /
    • pp.255-265
    • /
    • 2009
  • Recently many studies have been published on application of immediate loaded implants. However, the immediate loading protocol has not been well documented. The purpose of the present study was to evaluate the stress distribution between bone-implant interfaces and the effect of implant length in the anterior maxilla using 3 dimensional finite element analyses. The diameter 4.0 mm threaded type implants with different length(8.5 mm, 10.0 mm, 11.5 mm, 13.0 mm, 15.0 mm) were used in this study. The bone quality of anterior maxillary bone block was assumed to D3 bone. Bone-implant interfaces of immediately loaded implant were constructed using a contact element for simulating the non osseointegration status. For simplification of all the processing procedures, all of the material assumed to be homogenous, isotropic, and linearly elastic. The 178 N of static force was applied on the middle of the palatoincisal line angle of the abutment with $120^{\circ}$ angle to the long axis of abutment. Maximum von Mises stress were concentrated on the labial cortical bone of the implant neck area, especially at the cortical-cancellous bone interfaces. Compared the different length, highest peak stress value was observed at the 8.5 mm implants and the results indicated a tendency towards favorable stress distribution on the bone, when the length was increased. Presence of cortical bone was very important to immediate loading, and it appears that implants of a length more than 13 mm are preferable for immediate loading at the anterior maxilla.

A Study on the Impact Fracture of Fragile Materials (취성재료의 충격파괴에 관한 연구 II)

  • 양인영;김택현;정낙규;이상호;김선규
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.6
    • /
    • pp.1417-1425
    • /
    • 1990
  • In this paper, when the glass plate of fragile material is subjected to impact load, the fracture pattern and the generation phenomenon of cone crack were theoretically clarified by using the analysis method of impulsive stress in the first paper. The numerical analysis results of strain distribution at a distance of 0.1cm, from the impact loading point to 5cm, were compared with experimental results. The main conclusions obtained are as follows; (1) The generation phenomenon of cone crack at the impact fracture of the glass plate can be analytically confirmed by using the three dimensional dynamic theory of elasticity. And the numerical analysis results of strain distribution using this theory are relatively in close agreement with the crack size obtained from the impact fracture experiment. (2) After the stress wave generated at the impact point propagated to the spherical compressive wave, this stress wave reflected from the back surface and reached again at the surface of the plate to the spherical stress wave. Then the generation of cone crack can be confirmed along the stress wave surface. (3) The plate is the thicker, the more is the generation phenomenon of cone crack at the lower impact velocity range (20m/s-35m/s). Because the fracture generate before the maximum tensile stress acting to the glass plate, cone crack was rarely ever generated.

Effect of Bone Quality on Insertion Torque during Implant Placement; Finite Eelement Analysis (임플란트 식립 시 골질이 주입회전력에 미치는 영향에 관한 삼차원 유한요소 분석)

  • Jeong, Jae Doug;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.2
    • /
    • pp.109-123
    • /
    • 2009
  • The aim of the study was to assess the influence of insertion torque of bone quality and to compare axial force, moment and von Mises stress using finite element analysis of plastoelastic property for bone stress and strain by dividing bone quality to its thickness of cortical bone, density of trabecular bone and existence of lower cortical bone when implant inserted to mandibular premolar region. The $Br{\aa}nemark$ MKIII. RP implant and cylindrical bone finite model were designed as cortical bone at upper border and trabecular bone below the cortical bone. 7 models were made according to thickness of cortical bone, density of trabecular bone and bicortical anchorage and von Mises stress, axial force and moment were compared by running time. Dividing the insertion time, it seemed 300msec that inferior border of implant flange impinged the upper border of bone, 550msec that implant flange placed in middle of upper border and 800msec that superior border of implant flange was at the same level as bone surface. The maximum axial force peak was at about 500msec, and maximum moment peak was at about 800msec. The correlation of von Mises stress distribution was seen at both peak level. The following findings were appeared by the study which compared the axial force by its each area. The axial force was measured highest when $Br{\aa}nemark$ MKIII implant flange inserts the cortical bone. And maximal moment was measured highest after axial force suddenly decreased when the flange impinged at upper border and the concentration of von Mises stress distribution was at the same site. When implant was placed, the axial force and moment was measured high as the cortical bone got thicker and the force concentrated at the cortical bone site. The influence of density in trabecular bone to axial force was less when cortical bone was 1.5 mm thick but it might be more affected when the thickness was 0.5 mm. The total axial force with bicortical anchorage, was similar when upper border thickness was the same. But at the lower border the axial force of bicortical model was higher than that of monocortical model. Within the limitation of this FEA study, the insertion torque was most affected by the thickness of cortical bone when it was placed the $Br{\aa}nemark$ MKIII implant in premolar region of mandible.

Dentoalveolar Compensation of Hyperdivergent Skeletal Pattern in Children and Adults (개방교합성 골격 형태를 가진 아동과 성인의 치성보상 양상)

  • Jeon, Young-Mi;Park, Dong-Cheol;Kim, Jong-Ghee
    • The korean journal of orthodontics
    • /
    • v.29 no.2 s.73
    • /
    • pp.197-207
    • /
    • 1999
  • Although there is a severe underlying skeletal deformity, the dentition has often maintained some occlusal contact and interdigitation by the teeth compensating in their positions for the skeletal problem, and these dental compensations are manifested in all three planes of space. The purposes of present investigation were 1) to study the pattern of dentoalveolar compensation of hyperdivergent skeletal pattern , and 2) to compare the dentoalveolar compensations of hyperdivergent skeletal pattern in children with adults. The samples selected for this study were consisted of 60 subjects in normal group, 60 subjects in hyperdivergent group. Each was divided into two subgroups by age ; child groups($8\~12yr$ old) and adult groups(17yr old over). The findings of this study were as follows; 1. In child, hyperdivergent subjects had smaller posterior lower facial height(p<0.01) and slightly longer anterior lower facial height than normal ones. In adults, they still expressed smaller posterior lower facial height and much longer anterior lower facial height than normal ones(p<0.01). 2. Hyperdivergent subjects had larger amount of upper and lower incisor relative eruption to their basal bone length than normal ones(p<0.05). In adult, relative eruption of upper incisor was increasing(p<0.05), although relative eruption of lower incisor remained the same as the child. 3. In child, there was no difference between hyperdivergent group and nomal one in the upper and lower molar relative eruption to their basal bone length. In adult, hyperdivergent group had target amount of upper molar relative eruption than normal ones(p<0.01), but relative eruption of lower molar was similar to normal ones. 4. Hyperdivergent group had larger angle between lower occlusal plane and mandibular plane than normal group(p<0.01). Upper occlusal plane of adult groups rotated more antero-superiorly than child groups, and adult hyperdivergent group had sleeper upper occlusal plane than normal group(p<0.05).

  • PDF