• Title/Summary/Keyword: 산출세

Search Result 734, Processing Time 0.03 seconds

Development of Cloud Detection Method Considering Radiometric Characteristics of Satellite Imagery (위성영상의 방사적 특성을 고려한 구름 탐지 방법 개발)

  • Won-Woo Seo;Hongki Kang;Wansang Yoon;Pyung-Chae Lim;Sooahm Rhee;Taejung Kim
    • Korean Journal of Remote Sensing
    • /
    • v.39 no.6_1
    • /
    • pp.1211-1224
    • /
    • 2023
  • Clouds cause many difficult problems in observing land surface phenomena using optical satellites, such as national land observation, disaster response, and change detection. In addition, the presence of clouds affects not only the image processing stage but also the final data quality, so it is necessary to identify and remove them. Therefore, in this study, we developed a new cloud detection technique that automatically performs a series of processes to search and extract the pixels closest to the spectral pattern of clouds in satellite images, select the optimal threshold, and produce a cloud mask based on the threshold. The cloud detection technique largely consists of three steps. In the first step, the process of converting the Digital Number (DN) unit image into top-of-atmosphere reflectance units was performed. In the second step, preprocessing such as Hue-Value-Saturation (HSV) transformation, triangle thresholding, and maximum likelihood classification was applied using the top of the atmosphere reflectance image, and the threshold for generating the initial cloud mask was determined for each image. In the third post-processing step, the noise included in the initial cloud mask created was removed and the cloud boundaries and interior were improved. As experimental data for cloud detection, CAS500-1 L2G images acquired in the Korean Peninsula from April to November, which show the diversity of spatial and seasonal distribution of clouds, were used. To verify the performance of the proposed method, the results generated by a simple thresholding method were compared. As a result of the experiment, compared to the existing method, the proposed method was able to detect clouds more accurately by considering the radiometric characteristics of each image through the preprocessing process. In addition, the results showed that the influence of bright objects (panel roofs, concrete roads, sand, etc.) other than cloud objects was minimized. The proposed method showed more than 30% improved results(F1-score) compared to the existing method but showed limitations in certain images containing snow.

Development of High-Resolution Fog Detection Algorithm for Daytime by Fusing GK2A/AMI and GK2B/GOCI-II Data (GK2A/AMI와 GK2B/GOCI-II 자료를 융합 활용한 주간 고해상도 안개 탐지 알고리즘 개발)

  • Ha-Yeong Yu;Myoung-Seok Suh
    • Korean Journal of Remote Sensing
    • /
    • v.39 no.6_3
    • /
    • pp.1779-1790
    • /
    • 2023
  • Satellite-based fog detection algorithms are being developed to detect fog in real-time over a wide area, with a focus on the Korean Peninsula (KorPen). The GEO-KOMPSAT-2A/Advanced Meteorological Imager (GK2A/AMI, GK2A) satellite offers an excellent temporal resolution (10 min) and a spatial resolution (500 m), while GEO-KOMPSAT-2B/Geostationary Ocean Color Imager-II (GK2B/GOCI-II, GK2B) provides an excellent spatial resolution (250 m) but poor temporal resolution (1 h) with only visible channels. To enhance the fog detection level (10 min, 250 m), we developed a fused GK2AB fog detection algorithm (FDA) of GK2A and GK2B. The GK2AB FDA comprises three main steps. First, the Korea Meteorological Satellite Center's GK2A daytime fog detection algorithm is utilized to detect fog, considering various optical and physical characteristics. In the second step, GK2B data is extrapolated to 10-min intervals by matching GK2A pixels based on the closest time and location when GK2B observes the KorPen. For reflectance, GK2B normalized visible (NVIS) is corrected using GK2A NVIS of the same time, considering the difference in wavelength range and observation geometry. GK2B NVIS is extrapolated at 10-min intervals using the 10-min changes in GK2A NVIS. In the final step, the extrapolated GK2B NVIS, solar zenith angle, and outputs of GK2A FDA are utilized as input data for machine learning (decision tree) to develop the GK2AB FDA, which detects fog at a resolution of 250 m and a 10-min interval based on geographical locations. Six and four cases were used for the training and validation of GK2AB FDA, respectively. Quantitative verification of GK2AB FDA utilized ground observation data on visibility, wind speed, and relative humidity. Compared to GK2A FDA, GK2AB FDA exhibited a fourfold increase in spatial resolution, resulting in more detailed discrimination between fog and non-fog pixels. In general, irrespective of the validation method, the probability of detection (POD) and the Hanssen-Kuiper Skill score (KSS) are high or similar, indicating that it better detects previously undetected fog pixels. However, GK2AB FDA, compared to GK2A FDA, tends to over-detect fog with a higher false alarm ratio and bias.

The Advancement of Underwriting Skill by Selective Risk Acceptance (보험Risk 세분화를 통한 언더라이팅 기법 선진화 방안)

  • Lee, Chan-Hee
    • The Journal of the Korean life insurance medical association
    • /
    • v.24
    • /
    • pp.49-78
    • /
    • 2005
  • Ⅰ. 연구(硏究) 배경(背景) 및 목적(目的) o 우리나라 보험시장의 세대가입율은 86%로 보험시장 성숙기에 진입하였으며 기존의 전통적인 전업채널에서 방카슈랑스의 도입, 온라인전문보험사의 출현, TM 영업의 성장세 等멀티채널로 진행되고 있음 o LTC(장기간병), CI(치명적질환), 실손의료보험 등(等)선 진형 건강상품의 잇따른 출시로 보험리스크 관리측면에서 언더라이팅의 대비가 절실한 시점임 o 상품과 마케팅 等언더라이팅 측면에서 매우 밀접한 영역의 변화에 발맞추어 언더라이팅의 인수기법의 선진화가 시급히 요구되는 상황하에서 위험을 적절히 분류하고 평가하는 선진적 언더라이팅 기법 구축이 필수 적임 o 궁극적으로 고객의 다양한 보장니드 충족과 상품, 마케팅, 언더라이팅의 경쟁력 강화를 통한 보험사의 종합이익 극대화에 기여할 수 있는 방안을 모색하고자 함 Ⅱ. 선진보험시장(先進保險市場)Risk 세분화사례(細分化事例) 1. 환경적위험(環境的危險)에 따른 보험료(保險料) 차등(差等) (1) 위험직업 보험료 할증 o 미국, 유럽등(等) 대부분의 선진시장에서는 가입당시 피보험자의 직업위험도에 따라 보험료를 차등 적용중(中)임 o 가입하는 보장급부에 따라 직업 분류방법 및 할증방식도 상이하며 일반사망과 재해사망,납입면제, DI에 대해서 별도의 방법을 사용함 o 할증적용은 표준위험율의 일정배수를 적용하여 할증 보험료를 산출하거나, 가입금액당 일정한 추가보험료를 적용하고 있음 - 광부의 경우 재해사망 가입시 표준위험율의 300% 적용하며, 일반사망 가입시 $1,000당 $2.95 할증보험료 부가 (2) 위험취미 보험료 할증 o 취미와 관련 사고의 지속적 다발로 취미활동도 위험요소로 인식되어 보험료를 차등 적용중(中)임 o 할증보험료는 보험가입금액당 일정비율로 부가(가입 금액과 무관)하며, 신종레포츠 등(等)일부 위험취미는 통계의 부족으로 언더라이터가 할증율 결정하여 적용함 - 패러글라이딩 년(年)$26{\sim}50$회(回) 취미생활의 경우 가입금액 $1,000당 재해사망 $2, DI보험 8$ 할증보험료 부가 o 보험료 할증과는 별도로 위험취미에 대한 부담보를 적용함. 위험취미 활동으로 인한 보험사고 발생시 사망을 포함한 모든 급부에 대한 보장을 부(不)담보로 인수함. (3) 위험지역 거주/ 여행 보험료 할증 o 피보험자가 거주하고 있는 특정국가의 임시 혹은 영구적 거주시 기후위험, 거주지역의 위생과 의료수준, 여행위험, 전쟁과 폭동위험 등(等)을 고려하여 평가 o 일반사망, 재해사망 등(等)보장급부별로 할증보험료 부가 또는 거절 o 할증보험료는 보험全기간에 대해 동일하게 적용 - 러시아의 경우 가입금액 $1,000당 일반사망은 2$의 할증보험료 부가, 재해사망은 거절 (4) 기타 위험도에 대한 보험료 차등 o 비행관련 위험은 세가지로 분류(항공운송기, 개인비행, 군사비행), 청약서, 추가질문서, 진단서, 비행이력 정보를 바탕으로 할증보험료를 부가함 - 농약살포비행기조종사의 경우 가입금액 $1,000당 일반사망 6$의 할증보험료 부가, 재해사망은 거절 o 미국, 일본등(等)서는 교통사고나 교통위반 관련 기록을 활용하여 무(無)사고운전자에 대해 보험료 할인(우량체 위험요소로 활용) 2. 신체적위험도(身體的危險度)에 따른 보험료차등(保險料差等) (1) 표준미달체 보험료 할증 1) 총위험지수 500(초과위험지수 400)까지 인수 o 300이하는 25점단위, 300점 초과는 50점 단위로 13단계로 구분하여 할증보험료를 적용중(中)임 2) 삭감법과 할증법을 동시 적용 o 보험금 삭감부분만큼 할증보험료가 감소하는 효과가 있어 청약자에게 선택의 기회를 제공할수 있으며 고(高)위험 피보험자에게 유용함 3) 특정암에 대한 기왕력자에 대해 단기(Temporary)할증 적용 o 질병성향에 따라 가입후 $1{\sim}5$년간 할증보험료를 부가하고 보험료 할증 기간이 경과한 후에는 표준체보험료를 부가함 4) 할증보험료 반환옵션(Return of the extra premium)의 적용 o 보험계약이 유지중(中)이며, 일정기간 생존시 할증보험료가 반환됨 (2) 표준미달체 급부증액(Enhanced annuity) o 영국에서는 표준미달체를 대상으로 연금급부를 증가시킨 증액형 연금(Enhanced annuity) 상품을 개발 판매중(中)임 o 흡연, 직업, 병력 등(等)다양한 신체적, 환경적 위험도에 따라 표준체에 비해 증액연금을 차등 지급함 (3) 우량 피보험체 가격 세분화 o 미국시장에서는 $8{\sim}14$개 의적, 비(非)의적 위험요소에 대한 평가기준에 따라 표준체를 최대 8개 Class로 분류하여 할인보험료를 차등 적용 - 기왕력, 혈압, 가족력, 흡연, BMI, 콜레스테롤, 운전, 위험취미, 거주지, 비행력, 음주/마약 등(等) o 할인율은 회사, Class, 가입기준에 따라 상이(최대75%)하며, 가입연령은 최저 $16{\sim}20$세, 최대 $65{\sim}75$세, 최저보험금액은 10만달러(HIV검사가 필요한 최저 금액) o 일본시장에서는 $3{\sim}4$개 위험요소에 따라 $3{\sim}4$개 Class로 분류 우량체 할인중(中)임 o 유럽시장에서는 영국 등(等)일부시장에서만 비(非)흡연할인 또는 우량체할인 적용 Ⅲ. 국내보험시장(國內保險市場) 현황(現況)및 문제점(問題點) 1. 환경적위험도(環境的危險度)에 따른 가입한도제한(加入限度制限) (1) 위험직업 보험가입 제한 o 업계공동의 직업별 표준위험등급에 따라 각 보험사 자체적으로 위험등급별 가입한도를 설정 운영중(中)임. 비(非)위험직과의 형평성, 고(高)위험직업 보장 한계, 수익구조 불안정화 등(等)문제점을 내포하고 있음 - 광부의 경우 위험1급 적용으로 사망 최대 1억(億), 입원 1일(日) 2만원까지 제한 o 금융감독원이 2002년(年)7월(月)위험등급별 위험지수를 참조 위험율로 인가하였으나, 비위험직은 70%, 위험직은 200% 수준으로 산정되어 현실적 적용이 어려움 (2) 위험취미 보험가입 제한 o 해당취미의 직업종사자에 준(準)하여 직업위험등급을 적용하여 가입 한도를 제한하고 있음. 추가질문서를 활용하여 자격증 유무, 동호회 가입등(等)에 대한 세부정보를 입수하지 않음 - 패러글라이딩의 경우 위험2급을 적용, 사망보장 최대 2 억(億)까지 제한 (3) 거주지역/ 해외여행 보험가입 제한 o 각(各)보험사별로 지역적 특성상 사고재해 다발 지역에 대해 보험가입을 제한하고 있음 - 강원, 충청 일부지역 상해보험 가입불가 - 전북, 태백 일부지역 입원급여금 1일(日)2만원이내 o 해외여행을 포함한 해외체류에 대해서는 일정한 가입 요건을 정하여 운영중(中)이며, 가입한도 설정 보험가입을 제한하거나 재해집중보장 상품에 대해 거절함 - 러시아의 경우 단기체류는 위험1급 및 상해보험 가입 불가, 장기 체류는 거절처리함 2. 신체적위험도(身體的危險度)에 따른 인수차별화(引受差別化) (1) 표준미달체 인수방법 o 체증성, 항상성 위험에 대한 초과위험지수를 보험금삭감법으로 전환 사망보험에 적용(최대 5년(年))하여 5년(年)이후 보험 Risk노출 심각 o 보험료 할증은 일부 회사에서 주(主)보험 중심으로 사용중(中)이며, 총위험지수 300(8단계)까지 인수 - 주(主)보험 할증시 특약은 가입 불가하며, 암 기왕력자는 대부분 거절 o 신체부위 39가지, 질병 5가지에 대해 부담보 적용(입원, 수술 등(等)생존급부에 부담보) (2) 비(非)흡연/ 우량체 보험료 할인 o 1999년(年)최초 도입 이래 $3{\sim}4$개의 위험요소로 1개 Class 운영중(中)임 S생보사의 경우 비(非)흡연우량체, 비(非)흡연표준체의 2개 Class 운영 o 보험료 할인율은 회사, 상품에 따라 상이하며 최대 22%(영업보험료기준)임. 흡연여부는 뇨스틱을 활용 코티닌테스트를 실시함 o 우량체 판매는 신계약의 $2{\sim}15%$수준(회사의 정책에 따라 상이) Ⅳ. 언더라이팅 기법(技法) 선진화(先進化) 방안(方案) 1. 직업위험도별 보험료 차등 적용 o 생 손보 직업위험등급 일원화와 연계하여 3개등급으로 위험지수개편, 비위험직 기준으로 보험요율 차별적용 2. 위험취미에 대한 부담보 적용 o 해당취미를 원인으로 보험사고(사망포함) 발생시 부담보 제도 도입 3. 표준미달체 인수기법 선진화를 통한 인수범위 대폭 확대 o 보험료 할증법 적용 확대를 통한 Risk 헷지로 총위험지수 $300{\rightarrow}500$으로 확대(거절건 최소화) 4. 보험료 할증법 보험금 삭감 병행 적용 o 삭감기간을 적용한 보험료 할증방식 개발, 고객에게 선택권 제공 5. 기한부 보험료할증 부가 o 위암, 갑상선암 등(等)특정암의 성향에 따라 위험도가 높은 가입초기에 평준할증보험료를 적용하여 인수 6. 보험료 할증법 부가특약 확대 적용, 부담보 병행 사용 o 정기특약 등(等)사망관련 특약에 할증법 확대, 생존급부 특약은 부담보 7. 표준체 고객 세분화 확대 o 콜레스테롤, HDL 등(等)위험평가요소 확대를 통한 Class 세분화 Ⅴ. 기대효과(期待效果) 1. 고(高)위험직종사자, 위험취미자, 표준미달체에 대한 보험가입 문호개방 2. 보험계약자간 형평성 제고 및 다양한 고객의 보장니드에 부응 3. 상품판매 확대 및 Risk헷지를 통한 수입보험료 증대 및 사차익 개선 4. 본격적인 가격경쟁에 대비한 보험사 체질 개선 5. 회사 이미지 제고 및 진단 거부감 해소, 포트폴리오 약화 방지 Ⅵ. 결론(結論) o 종래의 소극적이고 일률적인 인수기법에서 탈피하여 피보험자를 다양한 측면에서 위험평가하여 적정 보험료 부가와 합리적 가입조건을 제시하는 적절한 위험평가 수단을 도입하고, o 언더라이팅 인수기법의 선진화와 함께 언더라이팅 인력의 전문화, 정보입수 및 시스템 인프라의 구축 등이 병행함으로써, o 보험사의 사차손익 관리측면에서 뿐만 아니라 보험시장 개방 및 급변하는 보험환경에 대비한 한국 생보언더라이팅 경쟁력 강화 및 언더라이터의 글로벌화에도 크게 기여할 것임.

  • PDF

Respiratory Gas Exchange and Ventilatory Functions at Maximal Exercise (최대운동시의 호흡성 가스교환 및 환기기능)

  • Cho, Yong-Keun;Jung, Tae-Hoon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.6
    • /
    • pp.900-912
    • /
    • 1995
  • Background: Although graded exercise stress tests are widely used for the evaluation of cardiorespiratory performance, normal standards on respiratory gas exchange and ventilatory functions at maximal exercise in Koreans have not been well established. The purpose of this study is to provide reference values on these by sex and age, along with derivation of some of their prediction equations. Method: Symptom-limited maximal exercise test was carried out by Bruce protocol in 1,000 healthy adults consisting of 603 males and 397 females, aged 20~66 years. Among them VC, $FEV_1$ and MVV were also determined in 885 cases. All the subjects were members of a health center, excluding athletes. During the exercise, subjects were allowed to hold on to front hand rail of the treadmill for safety purpose. Results: The $VO_2\;max/m^2$, $VCO_2\;max/m^2$ and $V_E\;max/m^2$ were greater in males than in females and decreased with age. The RR max in men and women was similar but decreased slightly with age. The $V_T$ max was markedly greater in men but showed no significant changes with age in either gender. The mean of $V_T$ max/VC, $V_E$ max/MVV and BR revealed that there were considerable ventilatory reserves at maximal exercise even in older females. The regression equations of the cardinal parameters obtained using exercise time(ET, min), age(A, yr), height(Ht, cm), weight(W, kg), sex(S, 0=male; 1=female), VC(L), $FEV_1$(L) and $V_E$ max(L) as variables are as follows: $VO_2\;max/m^2$(L/min)=1.449+0.073 ET-0.007A+0.010W-0.006Ht-0.209S, $VCO_2\;max/m^2$(L/min)=1.672+0.063ET-0.008A+0.010W-0.005Ht-0.319S, VE max/$m^2$(L/min)=58.161+1.503ET-0.315A-9.871S or VE max/$m^2$(L/min)=47.873+6.548 $FEV_1$-5.715 S, and VT max(L)=1.497+0.223VC-0.493S. Conclusion: Respiratory gas exchange and ventilatory variables at maximal exercise were studied in 1,000 non-athletes by Bruce protocol. During exercise, the subjects were allowed to hold on to hand rail of the treadmill for safety purpose. We feel that our results would provide ideal target values for patients and healthy individuals to be achieved, since our study subjects were members of a health center whose physical fitness levels were presumably higher than ordinary population.

  • PDF

Nutrition knowledge, eating attitudes, nutrition behavior, self-efficacy of childcare center foodservice employees by stages of behavioral change in reducing sodium intake (어린이집 조리종사자 대상의 나트륨 저감화 행동변화단계에 따른 영양지식, 식태도, 식행동, 자아효능감 비교)

  • Ahn, Yun;Kim, Kyung Won;Kim, Kyungmin;Pyun, Jinwon;Yeo, Ikhyun;Nam, Kisun
    • Journal of Nutrition and Health
    • /
    • v.48 no.5
    • /
    • pp.429-440
    • /
    • 2015
  • Purpose: The purpose of this study was to examine sodium-related nutrition knowledge, eating attitudes, eating behaviors, and self-efficacy by stages of behavioral change in reducing sodium intake among childcare center foodservice employees. Methods: Subjects (n = 333) were categorized according to two groups based on the stages of change; Pre-action stage (PA group: precontemplation/contemplation/preparation stage), Action stage (A group: action/maintenance stage). Results: A major source of sodium-related nutrition information was TV/radio (56.6%) and only 166 people (49.8%) have experienced nutrition education specific to sodium. Although the A group showed slightly higher scores for nutrition knowledge than the PA group, the difference was not significant. The percentages of correct answers for 'daily goal of sodium intake for adults (27.0%)', 'calculation of sodium content in nutrition labeling (30.3%)' were low for both groups. The A group (total score: 40.3) had more desirable eating attitudes regarding reducing sodium intake than the PA group (36.6, p < 0.001). The total score for eating behaviors was slightly higher in the A group (49.6) than in the PA group (48.5), but without statistical significance. The A group (total score: 58.2) also received higher scores for self-efficacy regarding reducing sodium intake than the PA group (52.5, p < 0.001). Conclusion: This study suggests that nutrition education for childcare center foodservice employees should be expanded and customized education should be implemented according to the stages in reducing sodium intake. It is also suggested that food companies make efforts to develop low-sodium products.

Study on PM10, PM2.5 Reduction Effects and Measurement Method of Vegetation Bio-Filters System in Multi-Use Facility (다중이용시설 내 식생바이오필터 시스템의 PM10, PM2.5 저감효과 및 측정방법에 대한 연구)

  • Kim, Tae-Han;Choi, Boo-Hun
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.48 no.5
    • /
    • pp.80-88
    • /
    • 2020
  • With the issuance of one-week fine dust emergency reduction measures in March 2019, the public's anxiety about fine dust is increasingly growing. In order to assess the application of air purifying plant-based bio-filters to public facilities, this study presented a method for measuring pollutant reduction effects by creating an indoor environment for continuous discharge of particle pollutants and conducted basic studies to verify whether indoor air quality has improved through the system. In this study conducted in a lecture room in spring, the background concentration was created by using mosquito repellent incense as a pollutant one hour before monitoring. Then, according to the schedule, the fine dust reduction capacity was monitored by irrigating for two hours and venting air for one hour. PM10, PM2.5, and temperature & humidity sensors were installed two meters front of the bio-filters, and velocity probes were installed at the center of the three air vents to conduct time-series monitoring. The average face velocity of three air vents set up in the bio-filter was 0.38±0.16 m/s. Total air-conditioning air volume was calculated at 776.89±320.16㎥/h by applying an air vent area of 0.29m×0.65m after deducing damper area. With the system in operation, average temperature and average relative humidity were maintained at 21.5-22.3℃, and 63.79-73.6%, respectively, which indicates that it satisfies temperature and humidity range of various conditions of preceding studies. When the effects of raising relatively humidity rapidly by operating system's air-conditioning function are used efficiently, it would be possible to reduce indoor fine dust and maintain appropriate relative humidity seasonally. Concentration of fine dust increased the same in all cycles before operating the bio-filter system. After operating the system, in cycle 1 blast section (C-1, β=-3.83, β=-2.45), particulate matters (PM10) were lowered by up to 28.8% or 560.3㎍/㎥ and fine particulate matters (PM2.5) were reduced by up to 28.0% or 350.0㎍/㎥. Then, the concentration of find dust (PM10, PM2.5) was reduced by up to 32.6% or 647.0㎍/㎥ and 32.4% or 401.3㎍/㎥ respectively through reduction in cycle 2 blast section (C-2, β=-5.50, β=-3.30) and up to 30.8% or 732.7㎍/㎥ and 31.0% or 459.3㎍/㎥ respectively through reduction in cycle 3 blast section (C-3, β=5.48, β=-3.51). By referring to standards and regulations related to the installation of vegetation bio-filters in public facilities, this study provided plans on how to set up objective performance evaluation environment. By doing so, it was possible to create monitoring infrastructure more objective than a regular lecture room environment and secure relatively reliable data.

Macromineral intake in non-alcoholic beverages for children and adolescents: Using the Fourth Korea National Health and Nutrition Examination Survey (KNHANES IV, 2007-2009) (어린이와 청소년의 비알콜성음료 섭취에 따른 다량무기질 섭취량 평가: 제 4기 국민건강영양조사 자료를 활용하여)

  • Kim, Sung Dan;Moon, Hyun-Kyung;Park, Ju Sung;Lee, Yong Chul;Shin, Gi Young;Jo, Han Bin;Kim, Bog Soon;Kim, Jung Hun;Chae, Young Zoo
    • Journal of Nutrition and Health
    • /
    • v.46 no.1
    • /
    • pp.50-60
    • /
    • 2013
  • The aims of this study were to estimate daily intake of macrominerals from beverages, liquid teas, and liquid coffees and to evaluate their potential health risks for Korean children and adolescents (1-to 19 years old). Assessment of dietary intake was conducted using the actual level of sodium, calcium, phosphorus, potassium, and magnesium in non-alcoholic beverages and (207 beverages, 19 liquid teas, and 24 liquid coffees) the food consumption amount drawn from "The Fourth Korea National Health and Nutrition Examination Survey (2007-2009)". To estimate the dietary intake of non-alcoholic beverages, 6,082 children and adolescents (Scenario I) were compared with 1,704 non-alcoholic beverage consumption subjects among them (Scenario II). Calculation of the estimated daily intake of macrominerals was based on point estimates and probabilistic estimates. The values of probabilistic macromineral intake, which is a Monte-Carlo approach considering probabilistic density functions of variables, were presented using the probabilistic model. The level of safety for macrominerals was evaluated by comparison with population nutrient intake goal (Goal, 2.0 g/day) for sodium, tolerable upper intake level (UL) for calcium (2,500 mg/day) and phosphorus (3,000-3,500 mg/day) set by the Korean Nutrition Society (Dietary Reference Intakes for Koreans, KDRI). For total children and adolescents (Scenario I), mean daily intake of sodium, calcium, phosphorus, potassium, and magnesium estimated by probabilistic estimates using Monte Carlo simulation was, respectively, 7.93, 10.92, 6.73, 23.41, and 1.11, and 95th percentile daily intake of those was, respectively, 28.02, 44.86, 27.43, 98.14, and 3.87 mg/day. For consumers-only (Scenario II), mean daily intake of sodium, calcium, phosphorus, potassium, and magnesium estimated by probabilistic estimates using Monte Carlo simulation was, respectively, 19.10, 25.77, 15.83, 56.56, and 2.86 mg/day, and 95th percentile daily intake of those was, respectively, 62.67, 101.95, 62.09, 227.92, and 8.67 mg/day. For Scenarios I II, sodium, calcium, and phosphorus did not have a mean an 95th percentile intake that met or exceeded the 5% of Goal and UL.

Comparison and evaluation of volumetric modulated arc therapy and intensity modulated radiation therapy plans for postoperative radiation therapy of prostate cancer patient using a rectal balloon (직장풍선을 삽입한 전립선암 환자의 수술 후 방사선 치료 시 용적변조와 세기변조방사선치료계획 비교 평가)

  • Jung, hae youn;Seok, jin yong;Hong, joo wan;Chang, nam jun;Choi, byeong don;Park, jin hong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.1
    • /
    • pp.45-52
    • /
    • 2015
  • Purpose : The dose distribution of organ at risk (OAR) and normal tissue is affected by treatment technique in postoperative radiation therapy for prostate cancer. The aim of this study was to compare dose distribution characteristic and to evaluate treatment efficiency by devising VMAT plans according to applying differed number of arc and IMRT plan for postoperative patient of prostate cancer radiation therapy using a rectal balloon. Materials and Methods : Ten patients who received postoperative prostate radiation therapy in our hospital were compared. CT images of patients who inserted rectal balloon were acquired with 3 mm thickness and 10 MV energy of HD120MLC equipped Truebeam STx (Varian, Palo Alto, USA) was applied by using Eclipse (Version 11.0, Varian, Palo Alto, USA). 1 Arc, 2 Arc VMAT plans and 7-field IMRT plan were devised for each patient and same values were applied for dose volume constraint and plan normalization. To evaluate these plans, PTV coverage, conformity index (CI) and homogeneity index (HI) were compared and $R_{50%}$ was calculated to assess low dose spillage as per treatment plan. $D_{25%}$ of rectum and bladder Dmean were compared on OAR. And to evaluate the treatment efficiency, total monitor units(MU) and delivery time were considered. Each assessed result was analyzed by average value of 10 patients. Additionally, portal dosimetry was carried out for accuracy verification of beam delivery. Results : There was no significant difference on PTV coverage and HI among 3 plans. Especially CI and $R_{50%}$ on 7F-IMRT were the highest as 1.230, 3.991 respectively(p=0.00). Rectum $D_{25%}$ was similar between 1A-VMAT and 2A-VMAT. But approximately 7% higher value was observed on 7F-IMRT compare to the others(p=0.02) and bladder Dmean were similar among the all plan(P>0.05). Total MU were 494.7, 479.7, 757.9 respectively(P=0.00) for 1A-VMAT, 2A-VMAT, 7F-IMRT and at the most on 7F-IMRT. The delivery time were 65.2sec, 133.1sec, 145.5sec respectively(p=0.00). The obvious shortest time was observed on 1A-VMAT. All plans indicated over 99.5%(p=0.00) of gamma pass rate (2 mm, 2%) in portal dosimetry quality assurance. Conclusion : As a result of study, postoperative prostate cancer radiation therapy for patient using a rectal balloon, there was no significant difference of PTV coverage but 1A-VMAT and 2A-VMAT were more efficient for dose reduction of normal tissue and OARs. Between VMAT plans. $R_{50%}$ and MU were little lower in 2A-VMAT but 1A-VMAT has the shortest delivery time. So it is regarded to be an effective plan and it can reduce intra-fractional motion of patient also.

  • PDF

The Precision Test Based on States of Bone Mineral Density (골밀도 상태에 따른 검사자의 재현성 평가)

  • Yoo, Jae-Sook;Kim, Eun-Hye;Kim, Ho-Seong;Shin, Sang-Ki;Cho, Si-Man
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.67-72
    • /
    • 2009
  • Purpose: ISCD (International Society for Clinical Densitometry) requests that users perform mandatory Precision test to raise their quality even though there is no recommendation about patient selection for the test. Thus, we investigated the effect on precision test by measuring reproducibility of 3 bone density groups (normal, osteopenia, osteoporosis). Materials and Methods: 4 users performed precision test with 420 patients (age: $57.8{\pm}9.02$) for BMD in Asan Medical Center (JAN-2008 ~ JUN-2008). In first group (A), 4 users selected 30 patient respectively regardless of bone density condition and measured 2 part (L-spine, femur) in twice. In second group (B), 4 users measured bone density of 10 patients respectively in the same manner of first group (A) users but dividing patient into 3 stages (normal, osteopenia, osteoporosis). In third group (C), 2 users measured 30 patients respectively in the same manner of first group (A) users considering bone density condition. We used GE Lunar Prodigy Advance (Encore. V11.4) and analyzed the result by comparing %CV to LSC using precision tool from ISCD. Check back was done using SPSS. Results: In group A, the %CV calculated by 4 users (a, b, c, d) were 1.16, 1.01, 1.19, 0.65 g/$cm^2$ in L-spine and 0.69, 0.58, 0.97, 0.47 g/$cm^2$ in femur. In group B, the %CV calculated by 4 users (a, b, c, d) were 1.01, 1.19, 0.83, 1.37 g/$cm^2$ in L-spine and 1.03, 0.54, 0.69, 0.58 g/$cm^2$ in femur. When comparing results (group A, B), we found no considerable differences. In group C, the user_1's %CV of normal, osteopenia and osteoporosis were 1.26, 0.94, 0.94 g/$cm^2$ in L-spine and 0.94, 0.79, 1.01 g/$cm^2$ in femur. And the user_2's %CV were 0.97, 0.83, 0.72 g/$cm^2$ L-spine and 0.65, 0.65, 1.05 g/$cm^2$ in femur. When analyzing the result, we figured out that the difference of reproducibility was almost not found but the differences of two users' several result values have effect on total reproducibility. Conclusions: Precision test is a important factor of bone density follow up. When Machine and user's reproducibility is getting better, it’s useful in clinics because of low range of deviation. Users have to check machine's reproducibility before the test and keep the same mind doing BMD test for patient. In precision test, the difference of measured value is usually found for ROI change caused by patient position. In case of osteoporosis patient, there is difficult to make initial ROI accurately more than normal and osteopenia patient due to lack of bone recognition even though ROI is made automatically by computer software. However, initial ROI is very important and users have to make coherent ROI because we use ROI Copy function in a follow up. In this study, we performed precision test considering bone density condition and found LSC value was stayed within 3%. There was no considerable difference. Thus, patient selection could be done regardless of bone density condition.

  • PDF

Effects of Varying Levels of Dietary Metabolizable Energy and Crude Protein on Growth Performance and Carcass Characteristics in Layer-type Growing Male Chicks (사료 내 대사 에너지 및 조단백질 수준이 산란종 수평아리의 성장성적과 도체특성에 미치는 영향)

  • Yun, Jeong-Geun;Kim, Hong-Rae;Oh, Sung-Taek;Zheng, Lan;Choi, Young-In;Choo, Yun-Kyung;An, Byoung-Ki;Lee, Sung-Ki;Kang, Chang-Won
    • Korean Journal of Poultry Science
    • /
    • v.39 no.2
    • /
    • pp.87-95
    • /
    • 2012
  • This experiment was conducted to investigate the effects of varying levels of metabolizable energy (ME) and crude protein (CP) on growth performance and carcass characteristics in layer-type growing male chicks. Nine hundred 1-d-old Hy-Line Brown male chicks were randomly allocated to 30 pens in a $2{\times}3$ factorial design. The experimental diets contained 2 levels of ME (2,800 kcal/kg and 2,950 kcal/kg) in combination with 3 levels of CP (17%, 18.5%, and, 20%). A significant interaction of ME and CP on feed intake was observed (p<0.05). No interaction was observed between ME and CP for 53 d BW gain or FCR, which improved linearly with dietary CP levels (p<0.05). A significant interaction or tendency was observed between ME and CP levels. The intake of ME for 1 g BW gain was linearly decreased with increasing CP levels (p<0.001). The intake of CP per bird was significantly increased in low ME (2,800 kcal/kg) treatment than that of the high ME treatment (2,950 kcal/kg) (p<0.05), and dietary CP level had more influence on CP intake for gram BW gain than level of ME. The relative weights of liver, spleen, breast meat and, leg were not influenced by the dietary treatments. Serum BUN, albumin, creatinine, and the activities of GOT and GPT were not influenced significantly by the diet treatment. In conclusion, the growth performance in layer-type male chicks was linearly increased when the level of dietary CP increased. The ME and CP did not affect the carcass characteristics and blood profiles. Therefore, the optimum levels of dietary ME and CP to improve the growth were 2,800 kcal/kg and above 18.5% in layer-type growing male chicks, respectively.