• Title/Summary/Keyword: 산소 투과성

Search Result 268, Processing Time 0.027 seconds

The Role of Oxygen Free Radicals from Endothelial Cells in Endotoxin-induced Endothelial Cell Cytotoxity (내독소에 의한 혈관 내피세포 손상에서 혈관 내피세포로부터 유리된 산소기의 역할에 관한 연구)

  • Choi, Hyung-Seok;Jeong, Ki-Ho;Yoo, Chul-Gyu;Kim, Young-Whan;Han, Sung-Koo;Shim, Young-Soo;Kim, Keun-Youl;Han, Yong-Chol;Jung, Ki-Suck
    • Tuberculosis and Respiratory Diseases
    • /
    • v.41 no.4
    • /
    • pp.319-327
    • /
    • 1994
  • Background: The pathogenetic mechanism of adult respiratory distress syndrome(ARDS) is not clearly defined yet, but it is well known that increased pulmonary capillary permeabilty is characteristic feature of ARDS. The increased alveolar-capillary permeability is usually preceded by damage of pulmonary artery endothelial cells. The released enzymes and oxygen free radicals from the activated neutrophils seem to play a predominant role in endothelial cell cytotoxicity. The activated neutrophils, however, probably are not the sole contributing factor in this type of damage because many cases of ARDS have been reported in severe neutropenia. Bacterial endotoxin perse and/or oxygen free radicals released from endothelial cells are suggested to be possible factors that contribute to the development of ARDS. The purpose of this study is to investigate the direct cytotoxicity of endotoxin and the role of oxygen free radicals released from the endothelial cells in endotoxin-induced endothelial cell cytotoxicity. Methods: First, to investigate whether endotoxin is cytotoxic to HUVE by itself, various doses of endotoxin were added to culture medium and cytotoxicity was measured. Second, to evaluate the possible role of oxygen free radical in endotoxin-induced HUVE cytotoxicity, various antioxidants were added on the endotoxin-induced HUVE cytotoxicity and cytotoxicity was measured. Third, to verify the release of oxygen free radicals from HUVE, the concentrations of hydrogen peroxide in the endotoxin-treated culture supernatant were measured. Finally, to observe the cytotoxic effect of hydrogen peroxide, HUVE cytotoxicity in the presence of various doses of hydrogen peroxide was measured. The fourth generations of subcultured HUVE from primary culture were used. The cell cytotoxicity was quantified by the chromium-51 release assay. Results: 1) Endotoxin alone showed HUVE cytotoxicity in a dose-dependent fashion. 2) Endotoxin-induced HUVE cytotoxicity was significantly attenuated by the pretreatment of catalase and DMTU. 3) Hydrogen peroxide was released from HUVE after endotoxin treatment in a dose-dependent fashion. 4) Exogenous hydrogen peroxide also showed HUVE cytotoxicity in a dose-dependent fashion. Conclusion: These results suggest that endotoxin alone can directly injure HUVE, and, oxygen-free radicals released from HUVE in response to endotoxin may also participate in the endotoxin-induced HUVE cytotoxicity.

  • PDF

The composition control of ITO/PET by Plasma Emission Monitors (PEM을 이용한 ITO/PET film 조성 제어)

  • 한세진;김용한;김영환;이택동
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.213-213
    • /
    • 1999
  • 현재 LCD용 기판재료는 ITO/glass를 전극으로 사용하고 있다. 그러나 유리기판은 무겁고 깨지기 쉽기 때문에 사용상 곤란한 점이 많다. 최근 flexible하고 가공성 및 생산성이 우수한 플라스틱한 ITO를 성막하여 EL용, Touch panel, plastic LCD용 사용하려는 시도로, roll-to-roll 연속 스퍼터링에 의한 ITO성막공정에 대한 연구가 최근 활발하게 이루어지고 있다. 폴리머는 유리에 비해 Tg 온도가 낮고, 기판으로부터의 수분 및 여러 종류의 가스방출이 심하기 때문에 유리와는 달리 ITO막의 제조에 있어 큰 차이점이 있다. 따라서, 폴리머에 반응성 스퍼터링을 하기 위해서는 표면처리가 중요한 변수가 되며, roll to roll sputter로 ITO 필름을 얻기 위해서는 폭과 길이 방향으로 균일한 막을 얻는 것이 중요하다. 두께 75$\mu\textrm{m}$, 폭 190mm, 길이 400m로 권취된 광학용 Polyethylene terephthalate(PET:Tg:8$0^{\circ}C$)위에 In-10%Sn의 합금타겟과 Unipolar pulsed DC power supply를 사용하여 반응성 마그네트론 스퍼터링 방법으로 0.2m/min의 속도로 연속 스퍼터링 하였다. PET를 Ar/O2 혼합가스로 플라즈마 전처리를 한 후, AFM, XPS를 이용하여 효과를 분석을 하였고, 성막전에 가스방출을 막기 위해 TiO를 코팅하였다. Pilot 연속 생산공정에서 재현성을 위해 PEM(Plasma Emission Monitor)의 optical emission spectroscopy를 이용, 금속과 산화물의 천이구역에서 sprtter된 I/Sn 이온과 산소 이온의 반응에 의한 최적의 플라즈마의 강도값을 입력하여 플라즈마의 radiation을 검출하고, 스퍼터링 공정중 실질적인 in-situ 정보로 이용하였다. PEM을 통하여 In/Sn의 플라즈마 강도변화를 조사하였다. 초기 In/Sn의 플라즈마 강도(intensity)는 강도를 100하여, 산소를 주입한 결과, plasma intensity가 35 줄어들었고, 이때 우수한 ITO 박막을 얻을 수 있었다. Pulsed DC power를 사용하여 아크 현상을 방지하였다. PET 상에 coating 된 ITO 박막의 표면저항과 광투과도는 4-point prove와 spectrophotometer를 이용하여 분석하였고, AES로 박막의 두께에 따른 성분비를 확인하였다. ITO 박막의 광투과도는 산소의 유량과 sputter 된 In/Sn ion의 plasma emission peak에 따라 72%-92%까지 변화하였으며, 저항은 37$\Omega$/$\square$ 이상을 나타내었다. 박막의 Sn/In atomic ratio는 0.12, O/In의 비율은 In2O3의 화학양론적 비율인 1.5보다 작은 1.3을 나타내었다.

  • PDF

Structural, Morphological, and Optical Properties of AlN Thin Films Subjected to Oxygen Flow Ratio (산소 유량비 변화에 따른 AlN 박막의 구조, 표면 및 광학적 특성)

  • Cho, Shin-Ho;Kim, Moon-Hwan
    • Journal of the Korean Vacuum Society
    • /
    • v.19 no.4
    • /
    • pp.287-292
    • /
    • 2010
  • We have investigated the effects of oxygen flow ratios on the structural, morphological, and optical properties of AlN thin films grown by using radio-frequency reactive magnetron sputtering. The AlN thin films were deposited at $300^{\circ}C$ of substrate temperature, and the reactive gas were supplied with both nitrogen and oxygen. The oxygen flow ratio was varied by controlling the amount of oxygen with respect to the total mixed gases, 0%, 10%, 15%, 20%, 25%, and 30%. The structural, morphological, and optical properties of the deposited AlN thin films were examined by using X-ray diffractometer, scanning electron microscopy, and ultraviolet-visible spectrophotometer. The AlN thin film grown at 10% of oxygen flow ratio indicated an average transmittance of 91.3% in the wavelength range of 350~1,100 nm and an optical band gap of 4.30 eV. The experimental results suggest that AlN thin films can be deposited optionally by varying the oxygen flow ratio.

Changes in Quality Characteristics of Bell Pepper Packaged with Different Films (포장 조건에 따른 피망의 저장 중 품질 특성 변화)

  • 박우포;조성환;김철환
    • Food Science and Preservation
    • /
    • v.10 no.2
    • /
    • pp.131-135
    • /
    • 2003
  • Bell pepper was packed with several plastic films, and investigated the quality Characteristics such as gas composition, weight loss, microbial load, soluble solid content, ascorbic acid and color during storage at 10$^{\circ}C$. Cast polypropylene (CPP), low density Polyethylene (LDPE), Polyolefin (MPD, PD961) and linear low density polyethylene (LLDPE) were used for this purpose. Oxygen concentration inside packages generally showed a 10∼14% after 1∼2 weeks, but package with CPP maintained above 15% throughout the storage. Carbon dioxide concentration of CPP was above 2%, but other treatments showed below 2%. Weight loss of all treatments was below 3.0% after 5 weeks. Total microbial count showed a similar pattern compared to yeast and mold, and CPP maintained the highest microbial load after 3 weeks. Yellowness (b value) of bell pepper was generally increased throughout the storage, and MPD and PD961 were higher than other treatments.

AgNW를 활용한 유연 투명히터 적용 연구

  • An, Won-Min;Jeong, Seong-Hun;Kim, Do-Geun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.133.1-133.1
    • /
    • 2016
  • 투명히터는 자동차유리 및 헤드램프의 성에 제거, 건축의 단열 및 난방, 의료용, 군사용 등 다양하게 사용되어지고 있으며, 더 나아가 플렉서블하고 웨어러블한 투명히터가 연구되고 있다. 투명히터에 사용되고 있는 대표적 투명전극인 Indium Tin Oxide (ITO)는 높은 투과도와 낮은 면저항을 가지지만 유연성이 좋지 않아 유연한 투명히터에 적용하기에는 어려움이 있다. 이를 해결하기 위해서 ITO를 대체할 수 있는 CNT, Graphene, AgNW, 전도성 고분자 등의 투명전극에 관한 연구가 활발히 진행되고 있다. 그러나 CNT, Grapene, 전도성 고분자는 여전히 전기적 특성이 좋지 못하기 때문에 차세대 투명전극으로 사용되기는 어려움이 있다. 반면에 AgNW는 용액공정으로 제조 단가가 비교적 저렴하며, 높은 전기전도 특성을 가지는 투명전극이다. AgNW는 나노와이어가 네트워크를 형성하고 있어 높은 전도성과 광 투과도를 가지지만 $200^{\circ}C$ 이상의 온도에서 손상된다. 이를 해결하기 위해 AgNW전극에 금속 산화막을 형성하여 내열성을 향상시키고자 하였다. 그러나 기존의 Reactive Sputter 방식으로 금속 산화막을 형성하게 되면 산소 분위기에서 AgNW가 산화되기 때문에 본 연구에서는 AgNW위에 금속 박막을 증착하고 Ion Beam 처리를 통해서 금속 산화막을 형성하여 AgNW 전극과 유사한 투과도와 저항을 가지면서 $300^{\circ}C$ 까지 열적 안정성을 확보하여 내열성을 향상시켰다. 유연한 PES기판 위에 스핀 코팅 방법으로 AgNW를 코팅하였고, Magnetron Sputter로 금속 박막을 형성한 후 Ion Beam 처리를 통해 금속 산화막을 형성하였다. 이를 적용하여 투명히터를 제작한 결과 유연 기판상 투명히터로 활용이 가능함을 확인하였다.

  • PDF

Influence of Physical Property of Soft Film and Packaging Method on the Storage Stability of Individually Packaged Fresh Ginseng (연포장재 필름의 물성 및 포장방법이 개별포장한 수삼의 저장성에 미치는 영향)

  • 손현주;김은희;노길봉;정광식;김정한
    • Journal of Ginseng Research
    • /
    • v.25 no.1
    • /
    • pp.45-52
    • /
    • 2001
  • The storage stability of fresh ginseng packaged individually in a soft film bag was more enhanced as the soft film with lower oxygen permeability was used, while the optimum water vapor permeability for enhancing the storage stability of fresh ginseng was estimated 3.5 g/m$^2$$.$day$.$90% RH when using the soft film with low oxygen permeability of 3.6∼5.4 cc/m$^2$$.$day$.$atm. The storage stability of the individually packaged fresh ginseng was also enhanced when the soft film bag was filled with carbon dioxide-oxygen-nitrogen (25:5:70) miked gas but the vacuum packaging exhibited little effect for the enhancement of storage stability of the fresh ginseng.

  • PDF

DC/RF 중첩형 마그네트론 스퍼터링법으로 증착한 ITO 초박막의 SnO2 함량에 따른 전기적 ,광학적 특성 및 미세구조 변화

  • Gang, Se-Won;Song, Pung-Geun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.280-281
    • /
    • 2012
  • 차세대 디스플레이에서 3차원 감성 터치 또는 플렉시블 기판 등에 사용되고 있는 ITO(Tin-doped Indium Oxide) 박막은 고 해상도 및 소자 효율 향상을 위해 전 가시광 영역에서 높은 투과율이 요구되고 있다. 일반적으로 ITO 박막은 두께 감소에 따라 빛의 두께 산란 없이 전 가시광 영역에서 높은 투과율을 가지는 반면, 두께가 감소할수록 박막 성장 시 비정질 기판의 영향을 크게 받아 박막 결정성 감소와 더불어 전기전도성이 감소되는 경향을 보인다. 특히, 매우 얇은 두께에서의 ITO 박막 물성은 초기 박막 핵 생성 및 성장과 증착 공정 중에 발생하는 고 에너지 입자(산소 음이온, 반사 중성 아르곤 등)의 박막 손상에 대한 영향을 크게 받을 뿐만 아니라 ITO 박막 내의 SnO2 도핑함량에도 매우 의존한다. 따라서, 매우 얇은 두께에서 높은 투과율과 뛰어난 전기전도성을 동시에 가지는 고품질 ITO 초박막 제조를 위해서는 박막 초기 핵 성장 제어기술 및 SnO2 함량에 따른 ITO 초박막의 전기적, 광학적 거동에 관한 연구가 필요하다. 본 연구에서는 다양한 SnO2 함량에서 고품질의 ITO 초박막을 DC/RF 중첩형 마그네트론 스퍼터링법을 이용하여 박막 증착 중에 발생하는 고에너지 입자의 기판충격으로 인한 박막손상을 최소화하여 증착된 박막의 전기적, 광학적 특성 및 미세구조를 관찰하였다. 그리고 전체파워에서 RF/(RF+DC) 비율을 제어하여 증착한 ITO 초박막의 물성을 최적화 하였으며, 상온 및 결정화 온도 이상에서 다양한 SnO2 함량을 가진 ITO 박막을 두께(150 nm, 25 nm)에서 각각 증착하여 전기적, 광학적 거동 및 XRD를 통한 박막의 미세구조 변화를 비교 분석하였다. 그리고 증착된 모든 ITO 초박막에서 가시광 투과율은 빛의 두께 산란 없는 높은 투과율(>85 %) 을 보이는 것을 확인 할 수 있었다. 증착된 ITO 박막의 전기적 특성 및 미세구조는 RF/(DC+RF)비율 50%에서 최적임을 확인하였다. 이는 RF/(DC+RF) 비율 증가에 따른 캐소드 전압 최적화로 박막의 초기 핵 성장 과정에서 기판상의 고에너지 입자로 인한 박막 손상의 감소 및 리스퍼터 되는 산소량을 최적화 시키고, 이는 박막의 결정성 향상으로 이어져, 박막내의 결함 밀도 감소 및 SnO2 고용 효율을 증가시켜 전기전도성 향상에 기인하였다고 판단된다. 또한, 증착된 ITO 초박막은 SnO2 함량 변화에 따라 박막의 결정성 및 전기적 특성에서 미세한 변화를 보였다. 이러한 ITO 박막의 물성변화는 박막 두께 감소에 따른 결정성 감소와 함께 SnO2의 고용 한계 변화로 인한 것으로 판단된다. 또한, RF/(DC+RF) 비율의 증가에 따른 ITO 초박막의 전기적, 광학적 및 미세구조는 Vp-Vf의 변화와 관련하여 설명되어 진다.

  • PDF

Development of Optical Sensor for Non-invasive Oxygen Saturation Measurement (비추출식 산소 포화도 측정용 광센서의 연구 개발)

  • Kwon, Ki-Jin;Park, Se-Kwang;Min, Byoung-Goo
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1991 no.11
    • /
    • pp.133-141
    • /
    • 1991
  • 혈중 산소 포화도는 생체의 중요한 정보로써 많은 학자들이 산소 포화도를 비추출방법으로 측정하기 위한 이론과 센서의 제작에 관해서 연구를 하고 있다. 혈액에서의 빗의 흡수(Absorption)와 산란(Scattering)에 관한 이론 연구가 Ishimaru, Takatani. Johnson 등의 학자들에 의해 진행되었고, Polanyi, Hehir, Johnson, Schmitt등에 의해서 센서 구조와 센서 제작에 관한 연구가 진행되고 있다. 산소 포화도를 직접 혈액을 추출하지 않고 비추출식으로 측정하게 된다면, 최근 우리나라에서도 인공 심장이 개발되고 있으므로 인공 심장의 제어에 필요한 정보로써 산소 포화도를 신속 정확하게 공급할 수 있어 인공 심장의 정확한 재어가 가능하다. 그리고 반도체 기술을 이용하여 소형화가 가능하므로 생체 적용성(Biocompatibility)이 우수하고 다기능을 가진 센서를 만들 수 있다. 본 논문에서는 비추출식으로 산소 포화도를 측정하기 위한 투과광 방식과 반사광 방식의 기본 이론 및 센서의 설계를 위한 기본 이론을 분석하였다. 그리고, 적색광의 사용가능성을 테스트하기 위한 모의 실험도 행하였다.

  • PDF

A Study on the Algorithm on Computing Model of Pulse Oximetry Using 2 Channel Sensor (2 채널 센서 펄스 옥시메터의 산소포화도 계산알고리즘에 관한 연구)

  • 김동철;이윤선;이경중;이성호
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.5
    • /
    • pp.573-579
    • /
    • 1999
  • 본 논문은 2채널 센서를 이용한 펄스 옥시메터의 산소포화도 계산 모델의 설계 및 분석에 관한 것이었다. 또한 Beer Lambert 법칙에 의거하여 기존 알고리즘 및 새로운 알고리즘들을 이론적으로 분석하였다. 제안된 알고리즘은 손가락을 투과한 2개의 채널에서 나온 광신호를 각각 직류성분 Adc 와 맥동성문 Aasin wt. 잡음성분 Ahnoise , ALnoise 등으로 모델링한다. 모델링 되어진 광신호를 맥동성분이 적분비를 사용하여 고주파 동잡음인 AHnoise 를 제거한 후 각각 산소포화도 계산을 위한 상관계수 그래프를 구한다. 또한 2개의 채널에서 적분비를 사용하여 구해진 상관계수 그래프를 사용하여 산소농도를 추출하는 방법에 관하여 기술하였다. 맥동성분비와 관혈적인 측정에 의한 혈중 산소포화도와의 상관관계 그래프의 선형성을 확보하기 위하여 펄스 옥시메터 시뮬레이터 오차범위를 고려해 75~100%상이의 산소포화도를 중점적으로 관측하였고, 4주기로 면적계산주기를 결정하여 실험하였다. 본 연구에서 제안된 알고리즘의 성능평가는 맥동성분의 적분비를 이용한 방법과 비교하였다. 비교결과는 4주기의 면적계산 주기를 가졌을 때 기존의 방식보다 평균오차가 0.7%정도 향상되었으며, 회귀적선의 신뢰도를 보여주는 결정계수 ${\gamma}$$^2$도 0.995로 기존의 방식에서 나온 0.979보다 더 좋은 결과를 얻을 수 있었다. 따라서 2채널을 이용한 방법이 A Lnoise 제거와 성능면에서 우수하다는 결론을 얻을 수 있었다.

  • PDF