• Title/Summary/Keyword: 산성가스 제거

Search Result 56, Processing Time 0.022 seconds

High Efficiency Hybrid Ion Exchange Chemical Filter for Removal of Acidic Harmful Gases (산성유해가스 제거를 위한 고효율 음이온교환 복합 폼 화학필터의 제조)

  • Jung, Youn Seo;Kim, In Sik;Hyeon, Seung Mi;Hwang, Taek Sung
    • Applied Chemistry for Engineering
    • /
    • v.28 no.5
    • /
    • pp.539-546
    • /
    • 2017
  • In this study, an outstanding anion exchange chemical filter was prepared for acidic gas removal. Commercial anion exchange resin was attached to polyurethane (PU) foam by using different types of pressure sensitive adhesive (PSA). The water and chemical resistance and also adhesive elongation were investigated. Also, the behavior of HCl and HF adsorption was evaluated as functions of the initial concentration and flow rate. ATE-701, AT-4000C and HCA-1000 showed 900, 1,500% and 2,400% of the elongation, respectively. It was confirmed that the desorption ratio of HCA-1000 was less than 6% and had excellent durability in water and chemical resistance tests. The adsorption occurred faster as the concentration and flow rate of HCl and HF increased. But 100% adsorption equilibrium occurred after 110 minutes, regardless of the concentration and flow rate. In addition, SEM morphology showed that the adhesive was uniformly dispersed, while the porous structure of the ion exchange resin was maintained, and the chemical filter exhibited excellent durability for the adsorption/desorption process.

The Cyclicality of Productivity, Market Power, and Returns to Scale in the Korean Open Economy: An Empirical Analysis 1975-2010 (한국경제의 총요소생산성의 순환성에 관한 실증분석(1975-2010))

  • Park, Sehoon;Zhu, Yan Hua
    • International Area Studies Review
    • /
    • v.15 no.3
    • /
    • pp.239-261
    • /
    • 2011
  • The cyclicality of productivity has been one of the essential issues in macroeconomics. Since Solow(1957) developed the dominant approach to the measurement of productivity growth, Solow's approach, which assumes the perfect competition, the constant returns to scale, and the full use of input factor has been modified particularly in Hall's(1990) and Basu's(1996) works. Their researches take account of market power, returns to scale, and variable factor utilization. This paper establishes the empirical model based on Hall's(1990) and Basu's(1996) models, estimates 4 types of Solow's reidual in manufacturing and 2 service industries over the period 1975:1-2010:4, and analyzes the cyclicality of measured productivity. The result proved the measured productivity to be procyclical in manufacturing industries and electricity and water industry, and in contrast to the Basu's, the variable factor utilization transformed the countercyclicality of measured productivity into its procyclicality in the Korean economy.

Removal of Chlorinated Organic Compounds in Flue Gas by Activated Carbon Injection in a Semi-Drying Reactor (반건식 반응기에서의 활성탄 혼합주입에 의한 소각로 배가스중의 유기 염소계 화합물의 제거 공정 연구)

  • Choo, Changupp;Whang, Jaedong;Lee, Joyoung;Cho, Chulhoon;Shin, Byungchul
    • Clean Technology
    • /
    • v.6 no.2
    • /
    • pp.121-127
    • /
    • 2000
  • There are several kinds of hazardous materials in incinerator flue gas, such as particulate matter, acid gas, heavy metal, dioxin, etc. The activated carbon adsorption is considered as one of the methods removing dioxin from flue gas. Without any additional equipment and facilities, the activated carbon was mixed with lime and sprayed in the semi-drying reactor of an incinerator and filtered in the bag filter, and its efficiency of removing hazardous organic material was investigated. 1,2-dichlorobenzene (o-DCB) was used as a precursor material of dioxin and the effects of the activated carbon amount, the operating temperature of the reactor, and the atomizer r.p.m were measured and analyzed. Experimental results showed that the optimum outlet temperature of the reactor was $145^{\circ}C$ considering the performance of the bag filter, and the adsorption performance improved with the increase of the atomizer r.p.m. Also the performance of removing o-DCB in the bag filter is higher than of the semi-drying reactor.

  • PDF

Simulation of the flue gas treatment processes of an industrial-waste incinerator using Aspen plus (Aspen plus를 이용한 산업폐기물 소각로의 배가스 처리 공정 모사)

  • Lee, Ju-Ho;Jung, Moon-Hun;Kwon, Young-Hyun;Lee, Gang-Woo;Shon, Byung-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.11
    • /
    • pp.3246-3252
    • /
    • 2009
  • The interest on the recovery of thermal energy using the waste has been rising to solve the problems of continuous increase of waste generation and the depletion of the fossil fuel recently. The incineration has been used most popularly as a treatment process of the waste for the energy recovery. However, it is expected that incineration and design cost will increase in the treatment of air contaminant emitted from incinerator. This research has simulated the actual incinerator and the flue gas treatment system using the Aspen plus which is the software to simulate the chemical process. The incineration process is composed of the 1st and 2nd combustor to burn the waste, SNCR process to reduce the $NO_x$ using the urea, and the steam generation process to save the energy during incineration. The $Ca(OH)_2$ slurry was used as an acid gas (HCl, $SO_2$) treatment materials and the removal efficiency for the products from the neutralization of acid gas in SDA and combustion ash was simulated at the bag filter. The simulation result has been corresponded with the treatment efficiency of emitted gas from the actual industrial waste incinerator and it is presumed to be used to forecast the efficiencies of flue gas treatment system in the future.

Acid Drainage and Damage Reduction Strategy in Construction Site: An Introduction (건설현장 산성배수의 발생현황 및 피해저감대책)

  • Kim, Jae-Gon
    • Economic and Environmental Geology
    • /
    • v.40 no.5
    • /
    • pp.651-660
    • /
    • 2007
  • Acid drainage has been recognized as an environmental concern in abandoned mine sites for long time. Recently, the environmental and structural damage by acid drainage is a current issue in construction sites in Korea. Here, the author introduces the type of damages by acid drainage in construction sites and emphasizes the importance of geoscience discipline in solving the problem. Metasedimentary rock of Okcheon group, coal bed of Pyeongan group, Mesozoic volcanic rock. and Tertiary sedimentary and volcanic rocks are the major rock types with a high potential for acid drainage upon excavation in Korea. The acid drainage causes the acidification and heavy metal contamination of soil, surface water and groundwater, the reduction of slope stability, the corrosion of slope structure, the damage on plant growth, the damage on landscape and the deterioration of concrete and asphalt pavement. The countermeasure for acid drainage is the treatment of acid drainage and the prevention of acid drainage. The treatment of acid drainage can be classified into active and passive treatments depending on the degree of natural process in the treatment. Removal of oxidants, reduction of oxidant generation and encapsulation of sulfide are employed for the prevention of acid drainage generation.

Practical Application of Mn-Cu Metal Catalyst for the Removal of Acetaldehyde (아세트알데히드 제거를 위한 Mn-Cu 금속촉매 실용화에 관한 연구)

  • Jung, Sung-Chul;Lee, Seung-Hwan
    • Journal of Digital Convergence
    • /
    • v.10 no.8
    • /
    • pp.201-210
    • /
    • 2012
  • Because sensing odor varies depending on each person, even if the odor is released in line with the legal emission permission concentration levels, it can still become a social issue if a civil complaint is made. The purpose of this research is to study the possibility of putting Mn-Cu metallic oxide catalysts into practical use to economically eliminate acetaldehyde which produces a odor in the industrial process. An optimal operating parameter to eliminate acetaldehyde was deduced through a performance evaluation in the research laboratory and the performance was verified by applying the parameter into an actual facility as an on-the-site experiment through a Scale-up of pilot size. The operating temperature of the metallic oxide catalysts researched so far was at the minimum close to $220^{\circ}C$, and the $220^{\circ}C$ elimination efficiency was 50% or below. However, having experimented by using a Mn-Cu metallic oxide catalyst in this research, optimum elimination efficiency showed when space velocity (GHSV) was equal to or below 6,000 $hr^{-1}$. The average elimination efficiency was 61.2% when the catalyst controlling temperature was $120^{\circ}C$, 93.3% when the catalyst controlling temperature was $160^{\circ}C$, and 94.9% when catalyst controlling temperature was $180^{\circ}C$, thereby reflecting high elimination efficiency. The specific surface area of the catalyst was $200m^2/g$ before use, however, was reduced to $47.162m^2/g$ after 24 months and therefore showed that despite the decrease in specific surface area as time passed, there was no significant influence on the performance. Having operated Mn-Cu metallic oxide catalyst systems for at least two years on a site where there was no inflow of toxins like sulfur compounds and acidic gases, we were able to confirm that elimination efficiency of at least 90% was maintained.

Estimation of air pollutants generated in the industrial-waste incinerator using Aspen plus (Aspen plus를 이용한 산업폐기물 소각공정시 발생 오염물질 예측)

  • Lee, Ju-Ho;Jung, Moon-Hun;Kwon, Young-Hyun;Kim, Min-Choul;Lee, Jae-Jeong;Lee, Gang-Woo;Shon, Byung-Hyun
    • Proceedings of the KAIS Fall Conference
    • /
    • 2009.12a
    • /
    • pp.1046-1049
    • /
    • 2009
  • 최근 화석에너지 고갈 문제와 폐기물의 지속적인 발생량 증가로 인해 폐기물을 이용한 열에너지 회수가 이슈화 되고 있다. 폐기물처리를 통한 에너지 회수 공정 가운데 소각이 가장 많이 이용되고 있으나 소각시 발생하는 대기오염 물질을 처리하기 위한 설계 및 설치비용에 많이 소요 된다. 본 연구에서는 화학공정 모사기인 Aspen plus를 이용해 소각공정 및 배가스 처리 공정모사를 실시하였다. 폐기물 소각 공정으로는 1 2차 연소실과 NO2를 환원하는 SNCR공정, 산성가스(HCl, SO2)를 제거하는 SDA공정, 입자상 물질을 처리 하는 bag filter공정을 모사하였다. 공정모사 결과 실제 산업폐기물 소각로의 처리효율과 일치 하였고 이를 바탕으로 동일한 공정 및 조건하에 소각로에 투입되는 폐기물의 조성비를 달리하여 공정 모사한 결과 오염물질의 배출량을 예측할 수 있었다. 이러한 오염물질 발생량 예측은 소각장의 폐기물 투입이 일정하지 않을 경우 조업 조건의 변경에 도움 뿐만아니라 공정개선의 효과적일 것으로 판단된다.

  • PDF

Microbial Conversion of Organic Wastes for Production of Biogas and Algal Biomass (바이오가스와 균체단백질 생산을 위한 유기질 폐기물의 미생물 전환 연구)

  • 권순찬;김진상
    • KSBB Journal
    • /
    • v.8 no.5
    • /
    • pp.438-445
    • /
    • 1993
  • Raw cow manure was treated by a 4-step integrated system with phase separation anaerobic digestion and algal culture. When the first methane fermentation was performed by the effluent from the acid fermenter with retention time of 4 days, the elrerage blogas production rate was 977m1/1 culture/day Gas productivity compared to conventional single-stage anaerobic digestion increased up to 31.4%. As the 2nd methane fermenter was fed by the effluent from the first methane fermenter with 4 days of retention time, average amount of 428m1/1 culture/day of biogas was produced. The reduction rate of COD in the effluent from the acid fermenter, the 1st and the 2nd methane fermenter were 71.8%, 42.6% and 24.0% respectively. Finally, we examined algal treatment process for the effluent from the 2nd methane fermenter. A semi-continuous culture of Chlorella sp. PSH3 was conducted by feeding the effluent with retention time of 10days. In this process, the production rate of algal biomass and COD reduction rate were averaged 1.8g/1 culture/day(2.8$\times$106 cells/ml) and 73%, respectively. Through the 4-setp treatments, the total chemical oxygen demand was reduced from 51,300ppm to 85ppm. Therefore, the reduction rate of total chemical oxygen demand reached about 99.8%. The results indicate that the integrated system could be applicable for treatment of organic wastes, concurrently producing biogas and algal biomass.

  • PDF

A Study on the Remanufacturing Effect of Aged Three-Way Catalysts (사용후 가솔린 자동차 삼원촉매의 재제조 효과 고찰)

  • Kwak, Seung-Min;Lim, Jong-Sun;Kim, Tae-Won;Park, Hae-Kyoung
    • Applied Chemistry for Engineering
    • /
    • v.20 no.4
    • /
    • pp.430-436
    • /
    • 2009
  • Deactivated three-way catalysts which had been exposed to gasoline engine exhaust for a long time were remanufactured by ultra sonic cleaning with distilled water, sulfuric acid solution and impregnation with precious metals (Pt, Pd, Rh). The catalytic properties as well as conversion reactivity of CO, THC and NOx about fresh, aged and remanufactured catalysts were examined. Most of the pollutants deposited on the aged three-way catalysts were removed in the remanufacturing process of those catalysts. At the same time a little amount of precious metals like Pt and Pd were removed in the remanufacturing process. Under the experimental condition used in this study, in the case of the remanufactured catalysts with impregnation of precious metals, the catalytic activities were recovered to almost the same level, or higher level of that of the fresh catalyst.

Removal Effect of Acid Gases by Reactant Mixer and Distributor of Bag Filter in Dry Scrubbing with NaHCO3 (중탄산나트륨 건식공정에서 반응제 혼합 장치 및 백필터 분배장치에 의한 산성가스 제거 영향)

  • Lee, Young-Man;Kwak, Yeon-Ho;Bae, Woo-Keun;Kwon, Ki-Wook
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.25 no.5
    • /
    • pp.402-409
    • /
    • 2009
  • Sodium bicarbonate ($NaHCO_3$) was used as a reactant for the removal of acid gases from a waste incinerator. The removal efficiencies of HCl and $SO_x$ were tested with a reactant mixing apparatus and a distributor installed at the bag filter inlet. It was shown that the stoichiometric ratio of $NaHCO_3$ to the acid gases which allows a removal of over 90% for both HCl and $SO_2$ was about 1.2. When a reactant mixing apparatus was installed on the duct, the removal efficiencies of HCl and $SO_2$ at the end of the duct were increased by approximately 1.5 and 3 times respectively, compared to when the apparatus was not installed. At the end of the bag filter, the removal efficiencies of the both were as high as 98% with a stoichiometric ratio of 1.35. Installing a reactant mixing apparatus on the duct and a distributor at the entrance of the bag filter and using $NaHCO_3$ as a reactant helped overcome the problem of low removal efficiencies of acid gases by dry scrubbing.