• Title/Summary/Keyword: 산란함수

Search Result 299, Processing Time 0.025 seconds

Capacitive Equivalent Circuit Modeling for Coplanar Waveguide Discontinuities (코플래너 웨이브가이드 불연속에 대한 용량성 등가회로 모델링)

  • 박기동;임영석
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.8 no.5
    • /
    • pp.486-487
    • /
    • 1997
  • This paper presents the pure capacitive lumped element equivalent circuits for several coplanar waveguide(CPW) discontinuities such as an open-end, an open-end with connected ground planes, a gap and an open-end CPW stub and gives their capacitive element values as a function of physical dimensions of the discontinuity and the frequency for a specific substrate. The capacitive element values are determined from the scattering parameters which are obtained using the finite-difference time-domain(FDTD) method. For an open-end, an open-end with connected ground planes and a gap, the numerical results of the FDTD are compared with the quasi-static results which are calculated using the three- dimensional finite difference method(3D-FDM).

  • PDF

Design and Fabrication of Stripline Circulator Including Structure of Ring Resonator (환형 공진기 구조를 갖는 스트립라인 서큘레이터 설계 및 제작)

  • 김동현;양두영
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.10 no.6
    • /
    • pp.866-878
    • /
    • 1999
  • In this paper, stripline circulator including a ferrite resonator which is consisted of a circular disk and two annuli disks is designed and fabricated. Using RGF(Recursive Green Function) technique, electromagnetic field of port and input impedance is presented. The circulator characteristics are compared according to the ferrite arrangement, bias field intensity and port width. The pass-band frequency of the fabricated circulator using the designed data is from 1.55 GHz to 2.95 GHz, the reflection coefficient $S_{11}$ of input port is -30 dB, and the transmission coefficient $S_{21}$ between input port and isolation port is -28 dB at resonating point 2.38 GHz.

  • PDF

MOM-Based Born Iterative Method for Medical Microwave Imaging (의용 전자파 영상을 위한 MoM 기반 Born 반복법의 적용)

  • Son, Jae-Gi;Kim, Bo-Ra;Lee, Taek-Kyung;Son, Seong-Ho;Jeon, Soon-Ik;Lee, Jae-Wook
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.4
    • /
    • pp.524-532
    • /
    • 2012
  • In this paper, we used MOM-based BIM(Born Iterative Method) algorithm to implement the inverse scattering for the detection of cancer. We adopted two-dimensional breast structure, integral equations and two-dimensional Green's function is solved with MoM(Method of Moment) to analyzing electromagnetic scattering phenomena. In addition, verifying the calculation of developed inverse scattering algorithm and analyzing medical applicability and limitations of the algorithm.

Preformance Comparison of MLE Technique with POF(Pencil of Functions) Method for SEM Parameter Estimation (SEM 파라메타 측정에 대한 MLE 기법과 POF 기법의 성능비교)

  • Kim, Deok-Nyeon
    • The Transactions of the Korea Information Processing Society
    • /
    • v.1 no.4
    • /
    • pp.511-516
    • /
    • 1994
  • Parameter estimation techniques are discussed for the complex frequency analysis of an electromagnetic scatterer. The paper suggests how the Maximum Likelihood estimation technique can be applied for this purpose. Experiments on hypothetical data sets demonstrate that the Maximum Likelihood technique is better than the Pencil of Functions technique. Although there have been several techniques including MLE suggested as tools of the parameter estimation, the proposed method has strong advantages under the noise-contaminated sample data environment because it uses minimal dimension of system matrix that stands totally independent of the length of extracted data set.

  • PDF

Analysis of the strip type waveguide mount backed by the dielectric substrate (유전체 기판 위에 놓인 스트립 형태의 도파관 마운트 해석)

  • 박면주;한석태;남상욱
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.21 no.9
    • /
    • pp.2505-2513
    • /
    • 1996
  • This paper presents the analysis of the impedance characteristic of the strip type waveguide mount backed by the dielectric substrate using mode the matching and induced EMF method. The part of the waveguide containing the dielectric substrate is modeled as waveguide partially filled with the dielectric, and a hybrid mode analysis has been conducted for the structure. The electromagnetic scattering problem by the dielectric substrate is solved by the mode matching method using the calculated modal function. The input impedance seen at the mount gap is calculated by the induced EMF method using the calculated results. the calculated results thus obtained has been verified through comparison with the results by other numerical methods. The effect of some structure parameters such as the width of the substrate and the gap size on the mount impedance is investigated.

  • PDF

A Simple Shell Model Approach to Lattice Dynamics of Cr, Mo, and W

  • Kim, Chang-Hyo;Chang, Jong-Hwa
    • Nuclear Engineering and Technology
    • /
    • v.7 no.2
    • /
    • pp.107-118
    • /
    • 1975
  • The lattice dynamics of Cr, Mo, and W are formulated in terms of a simple shell model in which the transition metal ions in the crystals are treated as deformable ions. The model involves a total of seven parameters; two charge parameters and five force constant parameters. The numerical values of the model parameters are determined by fitting to three elastic constants and the lattice vibrational frequencies measured by the neutron inelastic scattering experiments. Attempts are made to compute the phonon dispersion relations, the frequency distribution functions, and the lattice specific heats of three metals. The results are compared with experiments. It is found that the simple shell model can give a satisfactory account for the lattice vibrational characteristics of transition metals. The usefulness of the model is then discussed in comparison With other lattice dynamical models.

  • PDF

Shielding for Critical Organs and Radiation Exposure Dose Distribution in Patients with High Energy Radiotherapy (고 에너지 방사선치료에서 환자의 피폭선량 분포와 생식선의 차폐)

  • Chu, Sung-Sil;Suh, Chang-Ok;Kim, Gwi-Eon
    • Journal of Radiation Protection and Research
    • /
    • v.27 no.1
    • /
    • pp.1-10
    • /
    • 2002
  • High energy photon beams from medical linear accelerators produce large scattered radiation by various components of the treatment head, collimator and walls or objects in the treatment room including the patient. These scattered radiation do not provide therapeutic dose and are considered a hazard from the radiation safety perspective. Scattered dose of therapeutic high energy radiation beams are contributed significant unwanted dose to the patient. ICRP take the position that a dose of 500mGy may cause abortion at any stage of pregnancy and that radiation detriment to the fetus includes risk of mental retardation with a possible threshold in the dose response relationship around 100 mGy for the gestational period. The ICRP principle of as low as reasonably achievable (ALARA) was recommended for protection of occupation upon the linear no-threshold dose response hypothesis for cancer induction. We suggest this ALARA principle be applied to the fetus and testicle in therapeutic treatment. Radiation dose outside a photon treatment filed is mostly due to scattered photons. This scattered dose is a function of the distance from the beam edge, treatment geometry, primary photon energy, and depth in the patient. The need for effective shielding of the fetus and testicle is reinforced when young patients ate treated with external beam radiation therapy and then shielding designed to reduce the scattered photon dose to normal organs have to considered. Irradiation was performed in phantom using high energy photon beams produced by a Varian 2100C/D medical linear accelerator (Varian Oncology Systems, Palo Alto, CA) located at the Yonsei Cancer Center. The composite phantom used was comprised of a commercially available anthropomorphic Rando phantom (Phantom Laboratory Inc., Salem, YN) and a rectangular solid polystyrene phantom of dimensions $30cm{\times}30cm{\times}20cm$. the anthropomorphic Rando phantom represents an average man made from tissue equivalent materials that is transected into transverse 36 slices of 2.5cm thickness. Photon dose was measured using a Capintec PR-06C ionization chamber with Capintec 192 electrometer (Capintec Inc., Ramsey, NJ), TLD( VICTOREEN 5000. LiF) and film dosimetry V-Omat, Kodak). In case of fetus, the dosimeter was placed at a depth of loom in this phantom at 100cm source to axis distance and located centrally 15cm from the inferior edge of the $30cm{\times}30cm^2$ x-ray beam irradiating the Rando phantom chest wall. A acryl bridge of size $40cm{\times}40cm^2$ and a clear space of about 20 cm was fabricated and placed on top of the rectangular polystyrene phantom representing the abdomen of the patient. The leaf pot for testicle shielding was made as various shape, sizes, thickness and supporting stand. The scattered photon with and without shielding were measured at the representative position of the fetus and testicle. Measurement of radiation scattered dose outside fields and critical organs, like fetus position and testicle region, from chest or pelvic irradiation by large fie]d of high energy radiation beam was performed using an ionization chamber and film dosimetry. The scattered doses outside field were measured 5 - 10% of maximum doses in fields and exponentially decrease from field margins. The scattered photon dose received the fetus and testicle from thorax field irradiation was measured about 1 mGy/Gy of photon treatment dose. Shielding construction to reduce this scattered dose was investigated using lead sheet and blocks. Lead pot shield for testicle reduced the scatter dose under 10 mGy when photon beam of 60 Gy was irradiated in abdomen region. The scattered photon dose is reduced when the lead shield was used while the no significant reduction of scattered photon dose was observed and 2-3 mm lead sheets refuted the skin dose under 80% and almost electron contamination. The results indicate that it was possible to improve shielding to reduce scattered photon for fetus and testicle when a young patients were treated with a high energy photon beam.

L-band SAR-derived Sea Surface Wind Retrieval off the East Coast of Korea and Error Characteristics (L밴드 인공위성 SAR를 이용한 동해 연안 해상풍 산출 및 오차 특성)

  • Kim, Tae-Sung;Park, Kyung-Ae;Choi, Won-Moon;Hong, Sungwook;Choi, Byoung-Cheol;Shin, Inchul;Kim, Kyung-Ryul
    • Korean Journal of Remote Sensing
    • /
    • v.28 no.5
    • /
    • pp.477-487
    • /
    • 2012
  • Sea surface winds in the sea off the east coast of Korea were derived from L-band ALOS (Advanced Land Observing Satellite) PALSAR (Phased Array type L-band Synthetic Aperture Radar) data and their characteristics of errors were analyzed. We could retrieve high-resolution wind vectors off the east coast of Korea including the coastal region, which has been substantially unavailable from satellite scatterometers. Retrieved SAR-wind speeds showed a good agreement with in-situ buoy measurement by showing relatively small an root-mean-square (RMS) error of 0.67 m/s. Comparisons of the wind vectors from SAR and scatterometer presented RMS errors of 2.16 m/s and $19.24^{\circ}$, 3.62 m/s and $28.02^{\circ}$ for L-band GMF (Geophysical Model Function) algorithm 2009 and 2007, respectively, which tended to be somewhat higher than the expected limit of satellite scatterometer winds errors. L-band SAR-derived wind field exhibited the characteristic dependence on wind direction and incidence angle. The previous version (L-band GMF 2007) revealed large errors at small incidence angles of less than $21^{\circ}$. By contrast, the L-band GMF 2009, which improved the effect of incidence angle on the model function by considering a quadratic function instead of a linear relationship, greatly enhanced the quality of wind speed from 6.80 m/s to 1.14 m/s at small incident angles. This study addressed that the causes of wind retrieval errors should be intensively studied for diverse applications of L-band SAR-derived winds, especially in terms of the effects of wind direction and incidence angle, and other potential error sources.

Effective Detective Quantum Efficiency (eDQE) Evaluation for the Influence of Focal Spot Size and Magnification on the Digital Radiography System (X-선관 초점 크기와 확대도에 따른 디지털 일반촬영 시스템의 유효검출양자효율 평가)

  • Kim, Ye-Seul;Park, Hye-Suk;Park, Su-Jin;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.23 no.1
    • /
    • pp.26-32
    • /
    • 2012
  • The magnification technique has recently become popular in bone radiography, mammography and other diagnostic examination. However, because of the finite size of X-ray focal spot, the magnification influences various imaging properties with resolution, noise and contrast. The purpose of study is to investigate the influence of magnification and focal spot size on digital imaging system using eDQE (effective detective quantum efficiency). Effective DQE is a metric reflecting overall system response including focal spot blur, magnification, scatter and grid response. The adult chest phantom employed in the Food and Drug Administration (FDA) was used to derive eDQE from eMTF (effective modulation transfer function), eNPS (effective noise power spectrum), scatter fraction and transmission fraction. According to results, spatial frequencies that eMTF is 10% with the magnification factor of 1.2, 1.4, 1.6, 1.8 and 2.0 are 2.76, 2.21, 1.78, 1.49 and 1.26 lp/mm respectively using small focal spot. The spatial frequencies that eMTF is 10% with the magnification factor of 1.2, 1.4, 1.6, 1.8 and 2.0 are 2.21, 1.66, 1.25, 0.93 and 0.73 lp/mm respectively using large focal spot. The eMTFs and eDQEs decreases with increasing magnification factor. Although there are no significant differences with focal spot size on eDQE (0), the eDQEs drops more sharply with large focal spot than small focal spot. The magnification imaging can enlarge the small size lesion and improve the contrast due to decrease of effective noise and scatter with air-gap effect. The enlargement of the image size can be helpful for visual detection of small image. However, focal spot blurring caused by finite size of focal spot shows more significant impact on spatial resolution than the improvement of other metrics resulted by magnification effect. Based on these results, appropriate magnification factor and focal spot size should be established to perform magnification imaging with digital radiography system.

A STUDY ON THE RACIAL CLASSIFICATION OF ASIAN CHUM, ONCORHYNCHUS KETA(WALBAUM) BASED ON SCALE CHARACTERISTICS (인상(鱗相)에 의한 아시아계 백연어, Oncorhynchus keta(Walbaum)의 계통판정에 관한 연구)

  • KANG Yong Joo
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.7 no.2
    • /
    • pp.91-97
    • /
    • 1974
  • Two scale characters, the width ana circuli counts of the first-year band, were used in a discriminant function analysis to see how effectively the two scale characters would separate geographical chum stocks from the western North Pacific. A total of 476 scale samples were taken from spawning adults which ascended to rivers of Hokkaido, Japan, in 1956, and Kamchatka, the U.S.S.R., in 1957. The scale characters were examined for conformity to the statistical requirements of a discriminant function. As a result of the examinations the two characters were verified to be able to be used in a discriminant function analysis that would classify chum taken on the high seas to most Probable origin. A discriminant function computed using the two characters correctly classified 78.5 percent of the Hokkaido and Kamchatka chum fish. Of the two characters the number of the circuli could alone classify fish to its origin with nearly the same probability of correct classification as the discriminant function based on the two characters can.

  • PDF