• Title/Summary/Keyword: 산란감쇠

Search Result 118, Processing Time 0.041 seconds

Propagation of Elastic Waves in Fiber Reinforced Composites (섬유강화 복합재료 내의 탄성파 전파)

  • Kim, Jin-Yeon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.15 no.5
    • /
    • pp.65-72
    • /
    • 1996
  • A dynamic self-consistent method previously proposed and validated for the composites containing spherical inclusions is applied to the simplest two dimensional problems : SH wave propagation in unidirectional fiber reinforced composites. The self-consistent conditions for SH wave are derived without limitation on frequency and the wave speed and coherent attenuation are calculated for two composites. THe results of the present theory are compared with those of the multiple scattering theories and another self-consistent theory. At low volume fractions, the present theoretical results coincide with those of the multiple scattering theory using exact pair-correlation function, whereas the results based on another self-consistent theory deviate markedly from the others. As the volume fraction increases, the three theories give different results although they have qualitatively similar trends. The present theoretical results for composites considered in this paper exhibit less dispersion and physically realizable attenuation. An important observation is that the multiple scattering theory predicts vanishingly small attenuation at low frequency with volume fraction is high.

  • PDF

An Analysis of Inelastic Neutron Scattering by Liquid Methane

  • Chung, Chang-Hyun;Shin, Won-Kee;Kim, Jin-Soo
    • Nuclear Engineering and Technology
    • /
    • v.5 no.4
    • /
    • pp.265-278
    • /
    • 1973
  • The incoherent neutron scattering cross section of molecular liquids is analyzed using a damping function model for correlation functions of molecular translations and rotations. The present approach is different from recent works in that the scattering function is evaluated directly, not through the intermediate scattering function. The damping fuction is determined from a simple relation between its long-wavelength limit and the generalized frequency distribution function, and translation-rotation couplings are assumed to be neglected. A physical model is used for the translational motions of center-of-mass of a molecule, including properly its short-time and long-time behaviors. A simple model for the rotational motions is suggested which relates the damping function to the Fourier transform of the dipole correlation function, or equivalently, the infrared vibrational absorption spectrum. Theoretical absolute scattering intensities are computed for liquid methane and shown to be in satisfactory agreement with both thermal and cold neutron measurements.

  • PDF

Ultrasound attenuation coefficient estimation using recursive total least squares method (재귀적인 완전 최소자승법을 이용한 초음파 감쇠 계승 추정 기법)

  • Song Joon-Il;Choi Nakjin;Lim Jun-seok;Sung Koeng-Mo
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • autumn
    • /
    • pp.163-166
    • /
    • 2001
  • 초음파를 이용하여 인체 조직의 특성을 알아내는 방법은 매우 광범위하게 응용되어 오고있다. 그 중에서 초음파를 발생시킨 후 반사되어 되돌아오는 신호를 측정하여 그 감쇠 정도로부터 조직의 특성을 추정하는 방법이 많이 사용되고 있다. 이러한 감쇠현상은 발생된 초음파가 조직 내에서 흡수 또는 산란현상을 거치면서 주파수가 변이를 일으키기 때문에 발생한다. 따라서, 조직의 감쇠 특성을 알아내기 위해서, 주파수의 함수로 근사할 수 있는 감쇠 계수(attenuation coefficient)를 이용하여 시간에 따라 달라지는 주파수 변화를 추정한다. 그러나, 기존의 Ah(Auto-Regressive) 모델을 통한 시간영역 및 주파수 영역에서의 추정 방법을 사용하면 잡음이 존재하는 상황에서 시변 신호를 추정하는데 성능이 많이 저하된다. 본 논문에서는 이러한 단점을 보완하기 위해서, 가변 망각 인자와 재귀적인 TLS(Total Least Squares) 방법을 사용하여 시간에 따라 변하는 신호를 정확하게 추정하고 잡음환경에도 강인한 알고리듬을 제안하였다. 또한, 제안된 알고리듬은 추정 성능을 향상시킬 뿐 아니라 감쇠정도의 강약에 관계없이 망각인자의 값을 적응적으로 변화시켜 동작하는 장점을 가진다.

  • PDF

Attenuation Structure of the Mt. Fuji Region, Japan (일본 후지산의 감쇠구조)

  • Chung, Tae-Woong;Lees, Jonathan M.;Yoshimoto, Kazuo;Fujita, Eisuke;Ukawa, Motoo
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.97-100
    • /
    • 2008
  • Mount Fuji is the focus of intense study because of its potential hazard signaled by seismic, geologic and historical activity. Based on extensive seismic data recorded in the vicinity of Mt. Fuji, coda quality factor ($Q_c^{-1}$) using a single scattering model hypothesis, and intrinsic and scattering quality factor $(Q_i^{-1}$ and $Q_s^{-1})$ using the Multiple Lapse Time Window Analysis (MLTW) method was measured. To focus the study on the magmatic structure below Mt. Fuji, to the data were separated into two groups: a near-Fuji region of rays traversing an area with radius 5 km around the summit (R < 5 km), and a far-Fuji region of rays beyond a radius of 20 km around the summit (R > 20 km). The results of the study have a small error range due to the large data sample, showing that all $Q^{-1}$ values in near-Fuji area are greater than those of far-Fuji area, and $Q_i^{-1}$ for both the near and far-Fuji area is higher than $Q_s^{-1}$ at high frequencies. The $Q_i^{-1}$ values of the near-Fuji area are lower than those of the other volcanic areas considered, while values of $Q_s^{-1}$ are not. The low $Q_i^{-1}$ for the volcanic region of near-Fuji suggests that the magmatic activity, or percent of partial melt, at Mt. Fuji is not as active as hot spot volcanoes such as Kilauea, Hawaii.

  • PDF

A Study of Scattered Radiation Effect on Digital Radiography Imaging System (디지털 방사선영상 시스템에서 산란선이 영상 품질에 미치는 영향)

  • Baek, Cheol-Ha
    • Journal of radiological science and technology
    • /
    • v.40 no.1
    • /
    • pp.71-78
    • /
    • 2017
  • Scattered radiation is inherent phenomenon of x-ray, which occurs to the subject (or patient). Therefore it cannot be avoidable but also interacts as serious noise factor because the only meaningful information on x-ray radiography is primary x-ray photons. The purpose of this study was to quantify scattered radiation for various shooting parameters and to verify the effect of anti-scatter grid. We employed beam stopper method to characterize scatter to primary ratio. To evaluate effect on the projection images calculated contrast to noise ratio of given shooting parameters. From the experiments, we identified the scattered radiation increases in thicker patient and smaller air gap. Moreover, scattered radiation degraded contrast to noise ratio of the projection images. We find out that the anti-scatter grid rejected scattered radiation effectively, however there were not fewer than 100% of scatter to primary ratio in some shooting parameters. The results demonstrate that the scattered radiation was serious problem of medical x-ray system, we confirmed that the scattered radiation was not considerable factor of dig ital radiog raphy.

Accuracy Evaluation of CT-Based Attenuation Correction in SPECT with Different Energy of Radioisotopes (SPECT/CT에서 CT를 기반으로 한 Attenuation Correction의 정확도 평가)

  • Kim, Seung Jeong;Kim, Jae Il;Kim, Jung Soo;Kim, Tae Yeop;Kim, Soo Mee;Woo, Jae Ryong;Lee, Jae Sung;Kim, Yoo Kyeong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.1
    • /
    • pp.25-29
    • /
    • 2013
  • Purpose: In this study, we evaluated the accuracy of CT-based attenuation correction (AC) under the conventional CT protocol (140 kVp, on average 50-60 keV) by comparing the SPECT image qualities of different energy of radioisotopes, $^{201}Tl,\;^{99m}Tc$ and $^{131}I$. Materials and Methods: Using a cylindrical phantom, three different SPECT scans of $^{201}Tl$ (70 keV, 55.5 MBq), $^{99m}Tc$ (140 keV, 281.2 MBq) and $^{131}I$ (364 keV, 96.2 MBq) were performed. The CT image was obtained with 140 kVp and 2.5 mA in GE Hawkeye 4. The OSEM reconstruction algorithm was performed with 2 iterations and 10 subsets. The experiments were performed in the 4 different conditions; non-AC and non-scatter correction (SC), only AC, only SC, AC and SC in terms of uniformity and center to peripheral ratio (CPR). Results: The uniformity was calculated from the uniform whole region in the reconstructed images. For $^{201}Tl$ and $^{99m}Tc$, the uniformities were improved by about 10-20% AC was applied, but these were decreased by about 2% as SC was applied. The uniformity of $^{131}I$ was slightly increased as both AC and SC were applied. The CPR of the reconstructed image was close to one, when AC was applied for $^{201}Tl$ and $^{99m}Tc$ scans and $^{131}I$ was distant from 1 and that is only AC. Conclusion: The image uniformity improved by AC on low energy likely to $^{201}Tl$ and $^{99m}Tc$. However, image uniformity of high energy such as $^{131}I$ was improved, when both AC and SC was applied.

  • PDF

Experimental Investigation for the Attenuation Coefficient of Ultrasonic Guided Wave (유도초음파의 감쇠계수에 대한 실험적 고찰)

  • Lee, Dong-Jin;Cho, Youn-Ho;Lee, Joon-Hyun;Shin, Dong-Chul
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.5
    • /
    • pp.458-465
    • /
    • 2009
  • In general, ultrasonic guided wave techniques that used for an evaluation of the internal defect have been applied without considering energy loss. It can be found out that the significant attenuation is observed in the signal of structure with defect by the scattering and absorption. Even in the signal acquired from defect-free structure, this attenuation can be also significant. Therefore, it is very essential to determine the Lamb wave propagation characteristics depending on modes because the dispersibility of Lamb wave can be easily influenced by the attenuation effect with frequency and thickness. For this reason, changing the propagation distance, attenuation coefficient of each Lamb wave mode needs to be investigated by the contact pitch-catch method with PZT(piezoelectric) sensors. In this paper, the experimental attenuation coefficient is measured by choosing the following three different variables; mode, thickness and plate materials. As a result, experimental attenuation coefficient is obtained as the function of variables.

The Study on Ultrasound Physical Characteristic and Synthesis of Tissue Mimicking Materials Used New Materials (신소재를 사용한 인체조직모사물질의 합성과 초음파 물리적 특성에 관한 연구)

  • Ma, Sang-Chull;Kim, Hwa-Sun;Ann, Young-Man
    • Journal of radiological science and technology
    • /
    • v.33 no.3
    • /
    • pp.245-252
    • /
    • 2010
  • This study analyzed speed of sound, impedance, attenuation coefficient in accordance with acoustic characteristic standard of body soft tissue corresponding with Annex DD of IEC standard 60601-2-37(2007) which is about tissue mimicking materials (TMM) synthesized by polyurethane as a main material and new type of n-type scatter materials. This study reached the following conclusion after analyzing and evaluating image characteristic with SONOACE 9900 c PRIME (MEDESON Co.) and brightness, maximum penetration with convex probe (2.5~5.0 MHz). When n-type scatter materials are increasingly synthesised 0~8% with prepolymer as a main material and polyol mixture as a catalyst, 1. The more scatter materials are increased, the more sound speed of TMM becomes closely similar to soft tissue. 2. The more scatter materials are decreased, the more acoustic impedance becomes closely similar to soft tissue. 3. The more scatter materials are increased, the more attenuation coefficient is increased. 4. The more scatter materials are increased, the more average brightness of images is increased, but there is threshold. 5. The maximum penetration becomes closely similar to soft tissue at the 6% TMM as a scatter material.

Evaluation of Ultrasonic Multiple Scattering Method to Improve the Accuracy of Fine Dust Measurement (비산먼지 측정 정확도 개선을 위한 시뮬레이션 초음파 다중 산란 알고리즘 검증)

  • Woo, Ukyong;Choi, Hajin
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.6
    • /
    • pp.119-128
    • /
    • 2020
  • An ultrasonic multiple scattering simulation using cross-section of fine dust particles were proposed. These days, along with awareness of air pollution, social interest in fine dust is increasing. In the construction field, awareness of fine dust is increasing, and research on preparing various countermeasures is underway. The light scattering method fine dust meter currently in use is affected by environmental factors such as relative humidity, and reliability problems in terms of accuracy are continuously reported. However, the transmission of ultrasonic waves can directly reflect the physical change of the medium based on the mechanical wave. Using these advantages of ultrasonic waves, fine dust measurement simulation was performed using the scattering cross section and ultrasonic multiple scattering theory. The shape data of the fine dust particles were collected using a SEM (Scanning Electron Microscope), and a cross-section according to the fine dust particles was derived through numerical analysis. As a result of signal processing, the error for the number density corresponding to each cross-section is minimum 19, maximum 3455.

Correlation analysis of suspended sediment concentration and acoustic backscatter intensity (음파 후방산란강도와 부유사 농도의 상관관계 분석)

  • Park, JJi-Youn;Ryu, Hong Ryul;Kim, Dong-Ho;Hwang, Kyu-Nam
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2019.05a
    • /
    • pp.282-287
    • /
    • 2019
  • 본 연구의 목적은 음파를 이용하는 유속계로부터 관측된 후방산란강도와 실측된 부유사농도의 상관관계를 해석하여, 두 인자 사이의 관련 매개변수를 정량적으로 산정하고 관계식을 도출하는데 있다. 이를 위해 층별 유속계인 Aquadopp Profiler를 사용하여 사질 퇴적물 및 고령토 부유퇴적물 관측센서 검보정 챔버 실험을 수행하였다. 두 인자의 상관관계는 선형회귀분석을 통해 해석하였으며 그 결과로 도출된 접합곡선의 기울기는 각각 안목 A1 이 2.065, 안목 A2가 1.576, 고령토시료일 때 2.588의 값을 갖는데 이러한 차이는 시료 특성으로 설명될 수 있다. 서로 다른 입경을 갖는 시료는 후방산란 민감도에 차이가 있으며 이러한 영향으로 두 시료에서 산정된 계수 값에 차이가 발생한다. 본 연구를 통하여 도출된 측정 결과들은 후방산란강도에 미치는 수층 부유입자들의 영향이 매우 큼을 잘 보여준다. 일반적으로 수층 부유입자는 저면 퇴적물이 부유된 것으로 간주될 수 있으며, 또한 저면 퇴적물은 각 해역별로 site-specific 하다고 할 수 있다.

  • PDF