• Title/Summary/Keyword: 사용마찰계수

Search Result 394, Processing Time 0.027 seconds

An Expremental Study on Connections Friction Test of Improvement for Coastal Environment Block (Coastal Environments 블록의 개발을 위한 연결부 마찰 실험)

  • Kim, Chun-Ho;Kim, Sang-Hoonq
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.49-52
    • /
    • 2008
  • The plain and simple shape water front structure were designed and installed for wave protection and wave resistance. But the installation of these plain and simple structure cause deficiency of environmental affinity. Also the resonance phenomena from the reflective wave and shipwave of the harbor incident wave caused high tide and wave, consequently maintaining the tranquility of inside harbor, give difficulty for mooring the ship and loading-unloading, increase the possibility of ship collision at the quray wall and landing place To solve these problems, we develop the environmentally friendly wave dissipation block. And installation efficiency, stability of the blocks through experiment of C.E Block Joint.

  • PDF

Transformation of Irregular Waves in Shallow Water (천해에서 불규칙파의 변이)

  • 유동훈
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.5 no.3
    • /
    • pp.212-220
    • /
    • 1993
  • A numerical model for the transformation of irregular waves in a coastal area is developed, which takes account of shoaling, refraction, diffraction, bottom friction and wave breaking. The governing equations are the usual energy conservation equation and kinematic conservation equations, but to consider the diffraction effects additional terms are included in the usual kinematic conservation or wave number equations. A linear superposition technique is used to represent the spectral formation. and an explicit formula is developed for the estimation of friction factor of irregular waves. A breaking criterion of component waves, which is the modified form of the Kitaigorodskii saturation relation, is employed to restrict the growth of shoaling waves in very shallow waters. The model was applied to a laboratory test and satisfactory agreement was obtained between the computation and measurement.

  • PDF

Analytical Study on Behavior Characteristic of Shear Friction on Reinforced Concrete Shear Wall-Foundation Interface using High-Strength Reinforcing Bar (고강도 전단철근을 사용한 철근콘크리트 전단벽체-기초계면에서의 전단마찰 거동특성에 대한 해석적 연구)

  • Cheon, Ju-Hyun;Lee, Ki-Ho;Baek, Jang-Woon;Park, Hong-Gun;Shin, Hyun-Mock
    • Journal of the Korea Concrete Institute
    • /
    • v.28 no.4
    • /
    • pp.473-480
    • /
    • 2016
  • The purpose of this study is to provide analytical method to reasonably evaluate the complicated failure behaviors of shear friction of reinforced concrete shear wall specimens using grade 500 MPa high-strength bars. A total of 16 test specimens with a variety of variables such as aspect ratio, friction coefficient of interface in construction joint, reinforcement details, reinforcement ratio in each direction, material properties were selected and the analysis was performed by using a non-linear finite element analysis program (RCAHEST) applying the modified shear friction constitutive equation in interface based on the concrete design code (KCI, 2012) and CEB-FIP Model code 2010. The mean and coefficient of variation for maximum load from the experiment and analysis results was predicted 1.04 and 17% respectively and properly evaluated failure mode and overall behavior characteristic until failure occur. Based on the results, the analysis program that was applied modified shear friction constitutive equation is judged as having a relatively high reliability for the analysis results.

Characteristics of Starting Torque in Single Phase Permanent Magnet Motor (단상 영구자석 모타의 기동토오크 특성연구)

  • Kwon, Byung-Il;Kim, Ki-Bong
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.935-938
    • /
    • 2002
  • 본 논문은 회전자에 영구자석을 사용한 2극 단상 브러시리스 모타에서의 기동토오크 특성에 관한 연구결과를 소개함에 목적이 있다. 본 논문에서와 같은 구조의 모타에서의 토오크는 전자기력에 의한 기동력과 코깅 토오크에 의한 영향력 두가지로 구분다. 본 논문에서는 기동토오크의 이론적 구조식을 유도하고, 문리 적 운동방정식과 결합하여 기동시 나타나는 특성을 나타내었다. 본 논문의 목적은 보다 보편적인 기동토오크에 의한 회전자의 운동을 구명하고자 함인데, 이 목적을 위하여 일반적 전원으로 사용하는 연속 직류전류가 아니라, 비연속적이고 정현파 형태의 일펄스 반파 전류를 전원으로 사용하였다. 이때 나타나는 임펄스 응답특성은, 전류를 흘렸을 때, 대부분의 경우 모타의 회전자는 전류의 주기와 다른 주기를 가지고 반회전하였다. 모타 회전자의 반전주기는 입력전압, 영구자석의 자화의 강도, 그리고 관성계수 및 마찰 계수와 같은 기계적 상수에 의해 영향을 받는 것을 알수 있는데, 반전주기 속도가 모타의 동기속도와 적절하지 않는 경우, 모타의 회전은 이루어 지지 않거나 심한 흔들림(CHATTERINC)의 현상이 나타남을 발견하였다. 이러한 결과를 바탕으로 모타의 회전자를 동기속도로 구동을 하도록 하기위한 조건을 구하였다.

  • PDF

Evaluation of Heat Transfer Enhancement Performance for Wire Coil Inserts in Horizontal Smooth Tubes (수평 평활관 내부에 삽입한 와이어코일 인서트에 대한 전열성능평가)

  • 남상철;이주동;이상천
    • Journal of Energy Engineering
    • /
    • v.9 no.3
    • /
    • pp.202-211
    • /
    • 2000
  • 본 연구는 다양한 각도를 가지는 와이어코일을 사용하여 관내 단상 열전달 촉진 및 압력강하 특성 실험을 수행하였다. 작동유체는 순수 물과 에틸렌글리콜을 체적비율로 50% 혼합하여 사용하였으며, 시험부 관지름은 11mm와 13.88mm이고, 시험부 길이는 760mm를 사용하였다. 평활관과 와이어코일을 삽입한 열전달촉진관에 대한 관내 열전달계수와 마찰계수는 실험에서 측정한 온도, 유량, 압력강하 값을 기초로 구하였다. 와이어코일에 대한 거친표면해석을 수행하였으며, 그 결과를 거칠기 래이놀즈수에 대한 운동량전송 거칠기함수와 열전달 거칠기함수로 표현하였으며 이에 대한 상관식을 제시하였다. 이 상관식들은 거칠기 레이놀즈수, 코일 각도, 프란틀수의 함수로 표현하였다.

  • PDF

Analysis of Bearing Capacity for Shallow Foundation Considering the Effect of Roughness of Base (기초저면(基礎底面)의 조도(粗度)의 영향을 고려한 얕은기초(基礎)의 지지력(支持力) 해석(解析))

  • Hwang, Jung Kyu;Shin, Dong Hoon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.12 no.4
    • /
    • pp.167-177
    • /
    • 1992
  • This study analyses theoretically the bearing capacity of shallow foundation, considering the effect of roughness of base. The new bearing capacity factors based on the concept of limit equlibrium are succesfully derived. The simplified formula corresponding to the newly derived expressions are developed as well. The results of the present study are comparable to the conventional theories i.e., Terzaghi's, Meyerhofs, Vesic's and Yamaguchi's. In conclusion it is recommended that the upper limit of friction angle of soil be ${\varphi}=40^{\circ}$, and the angle of base friction be adquetely used with various ranges of ${\varphi}$ for safe designs and constructions.

  • PDF

Analysis of Hydraulic Similarity at Surcharged Square Manhole (과부하 사각형 맨홀에서의 수리학적 상사성 분석)

  • Kim, Jung-Soo;Yoon, Young-Noah;Han, Chyung-Such;Yoon, Sei-Eui
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2008.05a
    • /
    • pp.510-514
    • /
    • 2008
  • 우수 관거 시스템에서 맨홀의 설치 시 연결관 내부와 맨홀의 내부는 여러 가지 수리학적 조건이 다르므로 수두손실의 발생이 필연적일 수밖에 없다. 현재 계획 또는 설계단계에서 수행되고 있는 관거 시설의 수리계산에는 연결관 내에서의 마찰손실만을 고려하여 설계를 수행하고 있으며, 맨홀에서의 수두 손실은 거의 대부분 고려되지 않고 있다. 단지 맨홀에서의 수두손실을 저감하기 위하여 하수도시설기준(환경부, 2005)상의 단차 및 인버트 규정만 있을 뿐, 우수 관거 설계에 직접적으로 필요한 적절한 맨홀의 손실계수가 제시되지 않고 있는 실정이다. 국외에서는 축소 수리 모형을 이용한 실험과 수치해석 기법 등을 이용하여 맨홀에서의 손실계수를 산정하는 연구가 꾸준히 진행되어 왔으나 국내에서는 맨홀의 손실계수 산정에 관한 연구가 미흡한 실정이며, 더욱이 맨홀에서의 손실계수 산정을 위한 상사성 적용에 관한 연구는 전무한 실정이다. 그러므로 본 연구에서는 맨홀의 축척 변화에 따른 손실계수의 변화를 분석하기 위하여 하수도시설기준(환경부, 2005)의 특 1호(사각형) 맨홀을 각각 1/2과 1/5로 축소 제작하고, 수리실험 장치를 제작하였다. Froude 상사 법칙을 적용하여 1/2의 축소 모형의 실험 조건을 1/5 축소 모형의 값으로 환산하였으며, 각 축소 모형에 대한 수리 실험을 실시하였다. 과부하된 맨홀의 손실계수를 예측하는데 Froude 상사법칙의 사용 가능성을 확인 하였으며, 1/2 축소 모형과 1/5 축소 모형에서 산정된 손실계수 값이 0.45로 일치하고 있으므로 우수 관거 시스템의 맨홀 설계 시, 축소 수리 모형실험에서 산정된 손실계수의 직접적인 적용이 가능하다고 판단된다.

  • PDF

Evaluation on Fatigue Behavior of EP(Engineering Plastic) Friction Pendulum Bearing System (EP가 적용된 마찰 진자형 지진격리받침의 피로거동분석)

  • Choi, Jung-Youl;Park, Hee-Soo;Chung, Jee-Seung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.6 no.4
    • /
    • pp.703-708
    • /
    • 2020
  • As the risk of earthquakes increases recently, earthquake-resistant designs were getting interest. For this reason, this study applies that Friction pendulum-type seismic isolator is a device that attenuates seismic energy by friction and pendulum motion. The friction pendulum-type seismic isolator of this study is very easy to transport, install and maintain with light weight of metal by applying the slider using high strength engineering plastic. In addition, there is an advantage that the corrosion resistance is very excellent compared to the existing metal parts. However, there is concern about long-term durability by replacing metal materials. In this study, the frictional pendulum-type seismic isolator with EP was applied to compressive-shear test, repeated fatigue test, and ultimate load test after fatigue test, and analyzed the deformation and shear or properties after the test. As the results, the adequacy of long term fatigue durability was experimentally proven.

Analysis of Stream Characteristics at Combine Junction Manhole Using Fluent Model (Fluent 모형을 이용한 합류 맨홀에서의 흐름특성 분석)

  • Kim, Jung-Soo;Chio, Hyun-Soo;Kim, Hyung-Min;Yoon, Sei-Eui
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2010.05a
    • /
    • pp.649-653
    • /
    • 2010
  • 일반적으로 계획 또는 설계 단계에서 수행되고 있는 관거 시설의 수리계산에는 연결관 내에서의 마찰손실만을 감안하여 수행하고 있으며, 맨홀에서의 에너지 손실은 고려되지 않는 실정이다. 그러나 연결관 내부와 맨홀의 내부는 여러 가지 수리학적 조건이 다르므로 에너지 손실이 발생하게 된다. 더욱이 직선으로 연결된 중간맨홀보다 두 개의 유입관과 한 개의 유출관으로 구성된 합류맨홀은 연결 구조상 유수교란에 의한 에너지 손실이 커질 것으로 예상됨에도 불구하고 현재 실무에서 우수 배수시설의 설계 시 직선 연결맨홀과 합류맨홀의 손실을 구별하지 않고 사용하고 있는 실정이다. 그러므로 합류맨홀에서 우수 관거 시스템의 우수 배제 능력을 증가시켜 도심지의 침수를 방지하기 위한 관거시설의 적정 설계 기준이 필요하며, 합리적인 설계 기준을 제시하기 위하여 합류 맨홀 내에서의 수두 손실을 분석할 필요가 있다. 본 연구에서는 수리 모형 실험의 물질적, 시간적 한계를 극복하기 위하여 일반적으로 3차원 유체거동의 특성분석에 많이 사용되는 Fluent 6.3 모형을 이용하여 과부하 합류 맨홀에서의 흐름특성을 수치모의 하였으며, 맨홀 내 손실수두의 변화를 계산하여 손실계수를 산정하였다. 계산된 손실계수는 수리모형 실험을 통하여 산정된 손실계수와 비교하였다. 또한 동일한 수치모의 해석 조건을 실제 합류맨홀에 적용하여 실제 합류 맨홀의 규모 변화에 따른 손실계수를 산정하였다. 수치모형의 적용 결과 맨홀 내에서의 유속변화, 수심변화 및 압력변화에 대해서는 수리모형 실험 결과와 유사한 경향을 나타내고 있으며, 수치모형에 의하여 산정된 합류 맨홀에서의 손실계수 값과 수리모형에 의하여 산정된 손실계수 값이 거의 유사하게 나타났다. 또한 동일한 수치모의 해석 조건을 실제 합류맨홀에 적용하여 합류맨홀의 규모 변화에 따른 손실계수를 산정하였으며, 산정된 손실계수는 우수관거 시스템의 설계 및 평가에 사용가능하리라 판단된다.

  • PDF

Air-Side Performance of Fin-and-Tube Heat Exchanger with Copper Plate or Copper Spiral Fins (구리 재질의 평판 핀과 나선형 핀이 사용된 핀-관 열교환기의 공기측 성능)

  • Lee, Jin-Wook;Park, Ji-Hoon;Lee, Jung-Pyo;Kim, Nae-Hyun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.3
    • /
    • pp.269-278
    • /
    • 2011
  • We investigate the heat-transfer and pressure-drop characteristics of fin-and-tube heat exchangers with a copper plate or copper spiral fins. Twenty-four samples with different fin pitches and tube rows were tested. For both configurations, the effect of the fin pitch on the j factor is negligible, and the f factor increases with the fin pitch. The effect of the tube row depends on the configuration. For plate fin-and-tube heat exchangers, the j factor decreases as the row number increases; the reverse is true for spiral exchangers. We explain this by considering the flow pattern. The j factor for plate fin-and-tube heat exchangers is larger than that for spiral exchangers, and the difference decreases as the row number increases. The f factor of the plate fin-and-tube heat exchanger is also larger. We compare our results with existing predictions of correlations.