• Title/Summary/Keyword: 뼈

Search Result 1,061, Processing Time 0.029 seconds

Hierarchical Non-Rigid Registration by Bodily Tissue-based Segmentation : Application to the Visible Human Cross-sectional Color Images and CT Legs Images (조직 기반 계층적 non-rigid 정합: Visible Human 컬러 단면 영상과 CT 다리 영상에 적용)

  • Kim, Gye-Hyun;Lee, Ho;Kim, Dong-Sung;Kang, Heung-Sik
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.4
    • /
    • pp.259-266
    • /
    • 2003
  • Non-rigid registration between different modality images with shape deformation can be used to diagnosis and study for inter-patient image registration, longitudinal intra-patient registration, and registration between a patient image and an atlas image. This paper proposes a hierarchical registration method using bodily tissue based segmentation for registration between color images and CT images of the Visible Human leg areas. The cross-sectional color images and the axial CT images are segmented into three distinctive bodily tissue regions, respectively: fat, muscle, and bone. Each region is separately registered hierarchically. Bounding boxes containing bodily tissue regions in different modalities are initially registered. Then, boundaries of the regions are globally registered within range of searching space. Local boundary segments of the regions are further registered for non-rigid registration of the sampled boundary points. Non-rigid registration parameters for the un-sampled points are interpolated linearly. Such hierarchical approach enables the method to register images efficiently. Moreover, registration of visibly distinct bodily tissue regions provides accurate and robust result in region boundaries and inside the regions.

Arthroscopic Ankle Arthrodesis (관절경하 족근관절 고정술)

  • Bae Dae Kyung;Yoon Kyoung Ho;Ko Byoung Won;Cho Nam Su
    • Journal of the Korean Arthroscopy Society
    • /
    • v.4 no.2
    • /
    • pp.148-153
    • /
    • 2000
  • Purpose : This study was conducted to analyze the results of arthroscopic ankle arthrodesis and to verify the advantages of the technique compared to open ankle arthrodesis. Materials and Methods : Between October 1992 and August 1996, the arthroscopic ankle arthrodesis had been performed in five patients(six ankle joints): two patients with seropositive rheumatoid arthritis(one patient surgically treated bilaterally), two with osteoarthritis and one with tuberculous arthritis. There were one man and 4 women. Average age was 48 years ranging from 38 to 65 years. Follow up period was average 45 months(range, $12\~80$). Results : All patients were successfully treated with ankle joint arthrodesis under arthroscopic control. The mean time to fusion was 10 weeks(range, $6\~15$). There was a $100\%$ fusion rate without any complication. Conclusion : The arthroscopic ankle arthrodesis was successful in all cases with less morbidity and short hospital stay. It was technically feasible with excellent predictability.

  • PDF

A Case of Unilateral Focal Pigmented Paravenous Retinochoroidal Atrophy (단안에 국소적으로 발현된 색소정맥옆망막맥락막 위축 1예)

  • Park, Hyo Song;Yang, Jong Yun;Park, Hyun Ju
    • Journal of The Korean Ophthalmological Society
    • /
    • v.59 no.12
    • /
    • pp.1190-1194
    • /
    • 2018
  • Purpose: We report a case of unilateral, focal, pigmented paravenous retinochoroidal atrophy (PPRCA). Case summary: A 46-year-old female visited our clinic in complaint of a vague problem with her right eye identified during a general medical examination. The visual acuity (without correction) of both eyes was 1.0. Slit-lamp examination of both eyes revealed no specific signs. Fundus examination of the right eye revealed focal, bony-spicule-shaped retinochoroidal atrophy with pigmentation along the course of the superior retinal vein. A fundus autofluorescence examination revealed principally hypofluorescence with some hyperfluorescence at the margin of the atrophic retinochoroidal lesion. Optical coherence tomography revealed mixed clumping and atrophy of the retinal pigment epithelium (RPE) layer and thinning of the choriocapillaris layer. Fluorescence angiography revealed a window defect and blockage at the site of the lesion (the fluorescent material did not enter the lesion). The site of the window defect was in correlation with the atrophic RPE region. The site of the blockage at lesion also matched with the site of the regional pigment clumping. No definite leakage was observed. Conclusions: To the best of our knowledge, this is the first case of unilateral focal PPRCA reported from Korea.

'The Spirit is the bone' and the problem of the infinite judgement ('정신은 뼈다'와 무한 판단의 문제)

  • Lee, Jong-cheol
    • Journal of Korean Philosophical Society
    • /
    • v.143
    • /
    • pp.267-290
    • /
    • 2017
  • At the end of the 'observing reason' of the chapter of 'the Reason' in Hegel's PhdG, reads that 'Spirit is a bone' and it is an 'infinite judgement'. We will concentrate on the following problems to clarify the meaning of this infinite judgement. First, this paper introduces the various interpretations on the meaning of the 'Spirit is a bone' and makes a comparative investigation of that problem. If we do not examine the various interpretations, there may be the probability of arbitrary interpretation of this judgement. Second, we will discern the difference between Kant's and Hegel's interpretations with regard to the meaning of the infinite judgement. Hegel obviously understands the content more than the meaning of Kant's forms of infinite judgement (S is not-P). If we do not explicate the reason which Hegel expands beyond the form to the content, it is difficult to understand the meaning which Hegel has said on it. With regard to this, we do not restrict our study to the PhdG. We also refer to the meaning of the infinite judgement on 'the judgement of Dasein' in Hegel's small and large Logics. Third, We are going to explore the various interpretations concerning those problems. Above all, we note ${\check{Z}}i{\check{z}}ek^{\prime}s$ interpretation who relates it to Psychoanalysis. While examining ${\check{Z}}i{\check{z}}ek^{\prime}s$ interpretation, we expecially note how he can interpret it well.

Effect of mat pilates and kinesio taping on shoulder posture and muscle characteristics of college students with round shoulder posture (매트 필라테스와 키네지오 테이핑이 둥근 어깨 자세를 가진 대학생의 어깨 자세와 근육 특성에 미치는 영향)

  • Dolgion, Bayarbayasgalan;Jeong, Beom-Cheol;Yoo, Kyung-Tae
    • Journal of Convergence for Information Technology
    • /
    • v.11 no.12
    • /
    • pp.254-264
    • /
    • 2021
  • This study was conducted to investigate changes in posture and muscle characteristics by applying mat pilates and kinesio taping to college students with round shoulder posture and to investigate effective interventions. Subjects were 28 men and women with a round shoulder posture, and they were randomly assigned to a mat pilates group (MPG, n=14) and a Kinesio taping group (KTG, n=14). Each group performed the intervention for 4 weeks, and the distance from the ground to the acromion(DGA) and muscle characteristics (F: Frequency; S: Stiffness; D: Decrement) were measured before and after the intervention. Independent T-test was performed for the difference in the amount of change between groups, and the paired-sample T-test was performed for the difference between pre-post values within the group. Statistical significance level was set as 𝛼=.05. As a result of measuring the change in DGA in both groups, it was significantly decreased in MPG (p<.05). As a result of measuring the change in muscle characteristics of the two groups, the change in F in TL was significantly increased in MPG (p<.05), there was no change in TG, and the amount of change in MPG was larger in the amount of change between the two groups. appeared (p<.05). The change in S was significantly increased in MPG (p<.05). Therefore, the mat pilates conducted in this study is considered to be an effective intervention for improving the round shoulder posture and changing the muscle characteristics than kinesio taping.

Finite Element Analysis(fem) of The Fixed Position of the Velcro Band for the 3D Print Wrist Brace made using the Dicom File (CT Dicom 파일을 이용하여 제작한 3D Print 손목보호대용 Velcro band 고정위치의 유한요소해석(FEM))

  • Choi, Hyeun-Woo;Seo, An-Na;Lee, Jong-Min
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.5
    • /
    • pp.585-590
    • /
    • 2021
  • Wrist braces are being used for patients with wrist trauma. Recently, many studies have been conducted to manufacture custom wrist braces using 3D printing technology. Such 3D printing customized orthosis has the advantage of reflecting various factors such as reflecting different shapes for each individual and securing breathability. In this paper, the stress on the orthosis by the number and position of Velcro bands that should be considered when manufacturing a 3D printing custom wrist brace was analyzed. For customized orthosis, 3D modeling of the bone and skin regions was performed using an automatic design software (Reconeasy 3D, Seeann Solution) based on CT images. Based on the 3D skin area, a wrist orthosis design was applied to suit each treatment purpose. And, for the elasticity of the brace, a wrist brace was manufactured with an FDM-type 3D printer using TPU material. To evaluate the effectiveness according to the number and position of the Velcro band of the custom 3D printed wrist brace, the stress distribution of the brace was analyzed by the finite element method (FEM). Through the finite element analysis of the wrist orthosis performed in this study, the stress distribution of the orthosis was confirmed, and the number and position of the orthosis production and Velcro bands could be confirmed. These experimental results will help provide quality treatment to patients.

A Thoracolumbar Pure Spinal Epidural Cavernous Hemangioma - A Case Report - (흉요추부에서 발견된 경막외 해면상 혈관종 - 증례 보고 -)

  • Choi, Byeong Sam;Kim, Ju Yeon;Lee, Sungjoon
    • Journal of Korean Society of Spine Surgery
    • /
    • v.25 no.4
    • /
    • pp.169-174
    • /
    • 2018
  • Study Design: Case report. Objectives: We report a case of pure epidural cavernous hemangioma located at the thoracolumbar spine in a 53-year-old woman that mimicked a neurogenic tumor on magnetic resonance imaging (MRI). Summary of Literature Review: A pure spinal epidural cavernous hemangioma without bony involvement is a very rare lesion about which limited information is available in the literature. Materials and Methods: A 53-year-old woman visited our clinic for hypoesthesia with a tingling sensation in the left anterolateral thigh that had begun a month ago. No other neurologic symptoms or signs were present upon a neurologic examination. MRI from an outside hospital showed a $2.0{\times}0.5cm$ elongated mass at the T11-12 left neural foramen. The tumor was completely removed in piecemeal fashion. Results: The histopathologic examination revealed a cavernous hemangioma, which was the final diagnosis. The outcome was favorable in that only operation-related mild back pain remained, without any neurologic deficits, after a postoperative follow-up of 2 years and 3 months. No recurrence was observed on MRI at 2 years postoperatively. Conclusion: Pure epidural spinal cavernous hemangioma is very rare, and it is very difficult to differentiate from other epidural lesions. However, we believe that it should be included in the differential diagnosis of spinal epidural tumors due to its favorable prognosis.

The Evaluation of Dose Reduction and Quality of Images According to 80 kVp of Scan Mode Change in Pediatric Chest CT (소아 흉부 CT 검사에서 관전압 80 kVp 조건으로 스캔 모드별 방사선량 감소와 화질 평가)

  • Kim, Gu;Kim, Gyeong-Rip;Lee, Eun-Sook;Cho, Hee-Jung;Sung, Soon-Ki;Moon, Seul-ji-a;Kwak, Jong-Hyeok
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.8
    • /
    • pp.284-292
    • /
    • 2019
  • To evaluate the usefulness of pediatric chest CT scans by comparing the dose, examination time, and image quality by applying Helical mode, High-pitch mode, and Volume Axial mode to minimize the radiation exposure and obtain high diagnostic value. Revolution (GE Healthcare, Wisconsin USA) was used to divide PBU-70 phantom into Helical mode, High-pitch mode, and Volume Axial mode. After acquiring images, ROI is set for each image, heart, bone, lung, and back-ground air, and the average value is obtained by measuring CT number (HU) and noise (SD). SNR and CNR were measured and compared with DLP values provided directly by the equipment. Determining statistical significance Statistical analysis was performed using ONE-WAY-ANAOVA using SPSS 21.0. In this experiment, it was possible to inspect at a short time without deterioration of image quality with the lowest dose when using volume axial mode. Although the detector coverage of 16 cm is limited to all pediatric chest CT scans, it is recommended to be actively used in pediatric patients, and further study is needed to apply other test sites in volume axial mode.

MDCT Angiography of the Subclavian Artery Thrombosis of the 3D Findings (쇄골하동맥 혈전증에서의 MDCT 혈관조영술의 3D 영상)

  • Kweon, Dae Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.7
    • /
    • pp.813-819
    • /
    • 2018
  • To demonstrate the 3D usefulness of MDCT, a 73-year-old male patient with subclavian thrombosis was obtained 3D images of maximum intensity projection (MIP), volume rendering, and multiplanar reformation (MPR) to clearly detect and locate the subclavian artery. The data will be provided to the patient for diagnosis and treatment. The scan data were acquired as 3D CT images MIP, volume rendering, curved MPR, and virtual endoscopy images. In the 3D program, the ascending aorta was measured as 364.28 HU, the left carotid artery was 413.77 HU, and the left subclavian artery was 15.72 HU. MIP coronal image shows the closure of the subclavian artery in the left side. Three-dimensional volume images were obtained with 100% permeability and 87-1265 HU. The coronal curved MPR and sagittal curved MPR images show the closure of the subclavian artery due to thrombus using 3D image processing. In the case of subclavian arterial occlusion due to thrombosis, the patient is scanned with MDCT and 3D image processing can be used to confirm occlusion of subclavian artery.

Archaeogenetic Research of Excavated Human Bones from the Ancient Tombs (분묘 유적지 출토 인골에 대한 고고유전학 연구)

  • Jee, Sang Hyun;Chung, Yong Jae;Seo, Min Seok
    • Korean Journal of Heritage: History & Science
    • /
    • v.41 no.1
    • /
    • pp.99-108
    • /
    • 2008
  • The paleogenetic analysis has become an increasingly important subject of archaeological, anthropological, biological as well as public interest. Recently, scientific research for human skeletal remains was more activated because of increasing awareness of the valuable archaeological information by the ancient DNA analysis. State of preservation of organic remains vary in different soil and burying environmental condition. Almost all available tissue disappear to analysis ancient DNA of bone in acidic soil caused by climate and geological features in Korea. Many preserved human remains excavated in the 'Heogwakmyo'(limelayered tomb of Chosun Dynasty Period) is able to explain through the relationship between burial conditions and bone survival form the burial method and ceremony. Ancient DNA analysis of excavated human bone form ancient tomb requires to remove contaminants such as microorganism's DNA and soil components that affect authentic results. Particularly, contamination control of contemporary human DNA is major serious problem and should verified by criteria of authenticity. In order to understand migration and culture of ancient population, when possible, ancient DNA studies needs to go abreast both radiocarbon and stable isotope studies because the dietary inferences will suggest ancient subsistence and settlement patterns. Also when the paleogenetic research supported with the arts and humanities research such as physical anthropology and archaeology, more valuable ancient genetic information is providing a unique results about evolutionary and population genetics studies to reconstruct the past.