• Title/Summary/Keyword: 빔 추적법

Search Result 9, Processing Time 0.029 seconds

On the Errors of the Phased Beam Tracing Method for the Room Acoustic Analysis (실내음향 해석을 위한 위상 빔 추적법의 사용시 오차에 관하여)

  • Jeong, Cheol-Ho;Ih, Jeong-Guon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.27 no.1
    • /
    • pp.1-11
    • /
    • 2008
  • To overcome the mid frequency limitation of geometrical acoustic techniques, the phased geometrical method was suggested by introducing the phase information into the sound propagation from the source. By virtue of phase information, the phased tracing method has a definite benefit in taking the interference phenomenon at mid frequencies into account. Still, this analysis technique has suffered from difficulties in dealing with low frequency phenomena, so called, wave nature of sound. At low frequencies, diffraction at corners, edges, and obstacles can cause errors in simulating the transfer function and the impulse response. Due to the use of real valued absorption coefficient, simulated results have shown a discrepancy with measured data. Thus, incorrect phase of the reflection characteristic of a wall should be corrected. In this work, the uniform theory of diffraction was integrated into the phased beam tracing method (PBTM) and the result was compared to the ordinary PBTM. By changing the phase of the reflection coefficient, effects of phase information were investigated. Incorporating such error compensation methods, the acoustic prediction by PBTM can be further extended to low frequency range with improved accuracy in the room acoustic field.

Application of Biological Accelorator Mass Spectrometry by 6 MV in KIST

  • Lee, Gi-Su;Lee, Gyeong-Hui;Jo, Hye-Mi;Lee, Gwan-Ho;Kim, Jae-Yeol;Yu, Byeong-Yong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.146.2-146.2
    • /
    • 2014
  • KIST 6MV 가속기는 이온빔 분석 그리고 가속기 질량 분석법(Accelerator mass spectrometry)으로 활용된다. 이온빔 분석으로는 RBS, TOF ERD, PIXE. ${\mu}$-Probe을 할 수 있으며 AMS(Accelerator mass spectrometry)는 액체섬광측정법(LSC)과 비교할때 민감도는 1,000배 정도로 3H, 14C, 26Al,41Ca 을 10-21 ~ 10-18 mole/mg 까지 검출 가능하여. 응용분야로는 BAMS(Biological AMS), 전통과학, 지구과학, 환경과학에 활용되고 있다. 이중 AMS의 생-의학분야(BAMS)의 응용은 최근 매우 중요하게 연구되고 있다. BAMS의 활용 연구에 사용하는 핵종으로는 주로 3H, 14C, 41Ca, 36Cl를 사용하며, 14C 화합물은 쉽게 구할 수 있고, 자연방사선 이하의 낮은 14C labeled drug 사용하기 때문에 1948년 이후 생물학 연구에 혁신적으로 활용되고 있다. 주 활용분야로는 (1) 신약개발은 임상실험 전(Phase 0) 이용되며, 14C로 표지된 bio-molecule을 자연수준의 방사선 농도에서 추적자로 사용하여 질량을 측정하는 방법을 활용. (2) 의과학분야는 인체 내에서의 추적자 연구수행 (3) 항암제 연구는 암조직 중 약물농도와 암효과의 상관성을 연구 (4) 바이오 기술 분야에서는 생약 유효물질의 체내 대사연구 등을 할 수 있어 전세계적으로 활발히 연구가 진행되고 있다. KIST에서는 6MV가속기를 BAMS 연구에 활용하기 위하여 전처리 단계의 Combustion, Gas transfer, Reduction 등을 자체 제작하여 테스트 중에 있으며, BAMS 샘플의 Gas는 호기중의 성분, 대기 성분이 있으며, Liquid는 혈액(혈장,혈청,적혈구), Solid는 DNA, 세포, 장기 뼈, 피부, 식물조직, 사료, Drug 및 그 대사 류가 있다. AMS 측정 결과는 14C/12C 비율로 나타나며 그 결과를 농도로 환산하여 분석하게 된다. 또한 분석 데이터 신뢰를 확보하기 위하여 표준시료 및 품질관리용 시료를 사용하여 BAMS분석법에 대한 검증을 실시하였다.

  • PDF

An Indoor Propagation Modeling that can Analyze a Fading Characteristic (페이딩 분석이 가능한 실내 전파 모델링)

  • Seok, Woo-Chan;Kim, Jin-Woong;Yoon, Young-Joong;Seok, Jae-Ho;Lim, Jae-Woo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.27 no.1B
    • /
    • pp.114-124
    • /
    • 2002
  • In this paper, we proposed the image-based 3D ray tracing indoor propagation model using a patch scattering model for fading analysis of indoor propagation environments. An image-based 3D ray tracing technique is mainly used, which allows the rapid generation of the complex channel impulse response for any given location and polarization of transmitter and receiver. Due to the site specific nature of indoor environment, we took into account the location and the electrical properties of individual walls and objects such as windows, doors and plaster board in our propagation model. Besides, the 3D radiation beam-patterns and polarizations of arbitrary antennas were considered, and using patch scattering model we can consider the change of the polarization due to the scattering from the various indoor objects, like desks, chairs and etc. the are almost impossible to be modeled with the basic image-based ray tracing method. The model will predict the impulse response, the rms delay spread, the fading characteristics of the channel and performances of the polarization diversity schemes.

Development of Received Acoustic Pressure Analysis Program of CHA using Beam Tracing Method (Beam Tracing 기법을 이용한 수동 소나 센서의 수신 음압해석 프로그램 개발)

  • Kwon, Hyun-Wung;Hong, Suk-Yoon;Song, Jee-Hun;Jeon, Jae Jin;Seo, Young-Soo
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.50 no.3
    • /
    • pp.190-198
    • /
    • 2013
  • In order to predict acoustic pressure distributions by exterior incident wave at Cylindrical Hydrophone Array (CHA) sensor's positions, acoustic pressure analysis is performed by using beam tracing method. Beam tracing method is well-known of reliable pressure analysis methods at high-frequency range. When an acoustic noise source is located at the center of rectangular room, acoustic pressure analysis is performed by using both beam tracing method and Power Flow Boundary Element Method (PFBEM). By comparing with results of beam tracing method and those of PFBEM, the accuracy of beam tracing method is verified. We develop the CHA pressure analysis program by verified beam tracing method. The developed software is composed of model input, sensor array creator, analysis option, solver and post-processor. We can choose a model option of 2D or 3D. The sensor array generator is connected to a sonar which is composed of center position, bottom, top and angle between sensors. We also can choose an analysis option such as analysis frequency, beam number, reflect number, etc. The solver module calculates the ray paths, acoustic pressure and result of generating beams. We apply the program to 2D and 3D CHA models, and their results are reliable.

Range Estimating Performance Evaluation of the Underwater Broadband Source by Array Invariant (Array Invariant를 이용한 수중 광대역 음원의 거리 추정성능 분석)

  • Kim Se-Young;Chun Seung-Yong;Kim Boo-Il;Kim Ki-Man
    • The Journal of the Acoustical Society of Korea
    • /
    • v.25 no.6
    • /
    • pp.305-311
    • /
    • 2006
  • In this paper the performance of a array invariant method is evaluated for source-range estimation in horizontally stratified shallow water ocean waveguide. The method has advantage of little computationally effort over existing source-localization methods. such as matched field processing or the waveguide invariant and array gain is fully exploited. And. no knowledge of the environment is required except that the received field should not be dominated by purely interference This simple and instantaneous method is applied to simulated acoustic propagation filed for testing range estimation performance. The result of range estimation according to the SNR for the underwater impulsive source with broadband spectrum is demonstrated. The spatial smoothing method is applied to suppress the effect of mutipath propagation by high frequency signal. The result of performance test for range estimation shows that the error rate is within 20% at the SNR above 10dB.

Characteristics of Beam-tilting Slot Array Waveguide Antennas for DBS Reception (DBS 수신용 빔 틸트형 슬롯 어레이 도파관 안테나의 특성)

  • Min, Gyeong-Sik;Kim, Dong-Cheol;Arai, Hiroyuki
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.39 no.3
    • /
    • pp.140-149
    • /
    • 2002
  • This paper describes the characteristics of beam-tilting slot away waveguide antennas for mobile DBS reception. As a basic study of slotted waveguide array, design for 16 slot elements located on a broad-wall waveguide is considered. Design parameters such as slot length, space between each slot and cross slot angle of antennas with the beam-tilting characteristics are calculated by method of moments. Based on these results, the radiation waveguide antennas with 16-element $\times$16-array are designed and fabricated. The measured main beam direction angles of the fabricated antennas are 48$^{\circ}$to 50$^{\circ}$depending on the measured frequencies and it shows good agreement with prediction. The measured 3 dB beam width of elevation pattern is about 13$^{\circ}$, and the axial ratio and the gain measured at DBS band are observed 2.8 dB below and 24 dBi above, respectively. In order to evaluate a performance of the fabricated waveguide planar antenna, it is combined with the satellite tracking control system and the field performance test of antenna mounted on a mobile vehicle is carried out at highway. During the measurement, it was possible to watch television without a break signal in a driving vehicle and an excellent performance of the proposed antennas was demonstrated.

Evaluation of Absorbed Dose and Skin Dose with MDCT Using Ionization Chamber and TLD (이온 전리함 및 TLD 법을 이용한 Multi-Detector Computed Tomography의 흡수선량 및 체표면 선량 평가)

  • Jeon, Kyung Soo;Oh, Young Kee;Baek, Jong Geun;Kim, Ok Bae;Kim, Jin Hee;Choi, Tae Jin;Jeong, Dong Hyeok;Kim, Jeong Kee
    • Progress in Medical Physics
    • /
    • v.24 no.1
    • /
    • pp.35-40
    • /
    • 2013
  • Recently, the uses of Multi-Detector Computed Tomography (MDCT) for radiation treatment simulation and planning which is used for intensity modulated radiation therapy with high technique are increasing. Because of the increasing uses of MDCT, additional doses are also increasing. The objective of this study is to evaluate the absorbed dose of body and skin undergoing in MDCT scans. In this study, the exposed dose at the surface and the center of the cylindrical water phantom was measured using an pencil ionization chamber, 30 cc ionization chamber and TL Powder. The results of MDCT were 31.84 mGy, 33.58 mGy and 32.73 mGy respectively. The absorbed dose at the surface showed that the TL reading value was 33.92 mGy from MDCT. These results showed that the surface dose was about 3.5% from the MDCT exposure higher than a dose which is located at the center of the phantom. These results mean that the total exposed dose undergoing MDCT 4 times (diagnostic, radiation therapy planning, follow-up et al.), is about 14 cGy, and have to be considered significantly to reduce the exposed dose from CT scan.

Numerical Integration-based Performance Analysis of Amplitude-Comparison Monopulse System (진폭비교 모노펄스시스템의 수치적분 기반 성능분석)

  • Ham, Hyeong-Woo;Lim, Hee-Yun;Lee, Joon-Ho
    • Journal of Digital Convergence
    • /
    • v.19 no.12
    • /
    • pp.339-345
    • /
    • 2021
  • In this paper, estimation angle performance analysis of amplitude-comparison monopulse radar under additive noise effect is dealt with. When uncorrelated white noises are added to the squinted beams, the angle estimation performance is analyzed through the mean square error(MSE). The numerical integration-based mean square error result completely overlaps the Monte Carlo-based mean square error result, which corresponds to 99.8% of the Monte Carlo-based mean square error result. In addition, the mean square error analysis method based on numerical integration has a much faster operation time than the mean square error method based on Monte Carlo. the angle estimation performance of the amplitude comparison monopulse radar can be efficiently analyzed in various noise environments through the proposed numerical integration-based mean square error method.

Hypofractionated Radiation Therapy for Early Glottic Cancer - Preliminary Results - (초기 성문암 환자에서의 소분할 조사법을 이용한 방사선치료 - 예비적 결과 -)

  • Wu Hong-Gyun;Hong Semie;Shin Seong Soo;Park Charn Il
    • Radiation Oncology Journal
    • /
    • v.19 no.4
    • /
    • pp.301-305
    • /
    • 2001
  • Purpose : This study was peformed for the evaluation of the feasibility and toxicity of hypofractionated radiation therapy for early glottic cancer Methods and Materials : From February 1999 to February 2000, 20 patients with Histologically confirmed Stage I, II glottic cancer were enrolled into this study. There were 18 males and 2 females, the median age of the patients was 59 years. The distribution of stage distribution was as fellows; T1aN0-16 patients, T1bN0-1 patient, T2N0-3 patients. Eighteen patients underwent laryngomicroscopic biopsy only, and two patients underwent laser cordectomy. All patients received radical radiation therapy (2.5 Gy per fraction, 24 fractions, total 60 Gy). Median duration of treatment was 36 days (range $31\~45\;days$). Results : Radiation therapy were well tolerated. Most common acute reactions were odynophagia and hoarseness, and these reactions resolved after radiation therapy. There were one case of RTOG grade 3 odynophagia $(5\%)$, six cases of grade 3 hoarseness $(30\%)$. Response of radiation therapy was evaluated one month after completion of treatment. All patients revealed complete response. During follow up, total three cases of treatment failure were detected. two cases were local recurrence in 10 and 13 months of radiation therapy and one case was local recurrence and distant metastasis in 2 months of radiation therapy. Conclusion : This hypofractionated radiation therapy schedule was feasible and effective for control of early glottic cancer But longer follow up time would be required to assess the long-term disease control and the late complication by shortening radiation therapy duration.

  • PDF