• Title/Summary/Keyword: 빔 설계

Search Result 840, Processing Time 0.03 seconds

A Study on Sample Frequency Channel Selection of Near-Field Receiving Measurement for the Active Phased Array Antenna for Mono-Pulse Accuracy (모노펄스 정확도를 위한 능동배열위상레이다의 근접전계 수신시험 표본 주파수 채널 선택에 대한 연구)

  • Kwon, Yong-Wook;Yoon, Jae-Bok;Yoo, Woo-Sung;Jang, Heon-Soon;Kim, Do-Yeol
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.28 no.4
    • /
    • pp.318-327
    • /
    • 2017
  • It is essential for the near-field receiving measurement to make beam pattern and check the performance of a active phased array antenna system. Also, we could obtain compensation value for mono-pulse function through the near-field receive test, however, if the radar has many frequency channel, the test would take long time and hard effort. So it is needed that frequency channels are selected for measurement and calculates the values for other frequency channels to improve efficiency in development and manufacture. In this case, the phase variations in sum and del channels would be checked. The phase measurement includes un-linear characteristic because of wrapping effect. Generally, radars have similar path length in sum and del channel, but if a radar has a electrical length gap between sum and del channel, errors could occur by phase's wrapping effect. In this paper, the interpolation method's error caused by electrical length gap is checked and the effective method for frequency channel selection to avoid wrapping effect is introduced.

Design and embodiment of stable system by change of action waveform by pulsemodule special quality of pulse style$CO_2$ laser for obstetrics and gynecology (산부인과용 펄스형 $CO_2$레이저의 펄스모듈 특성과 동작파형 변화에 따른 안정된 시스템의 설계 및 구현)

  • Kim, Whi-Young
    • Journal of the Korea Computer Industry Society
    • /
    • v.8 no.2
    • /
    • pp.97-102
    • /
    • 2007
  • [ $CO_2$ ] laser sees that is most suitable to get this effect through minimum formation damage and advantage that is root enemy of effect that happen in minimum cellular tissue depth of 0.1mm is stable living body organization or internal organs institution. Formation damage by ten can be related in formation's kind or energy density, length of evaporation time. If shorten evaporation time, surroundings cellular thermal damage 200 - because happen within 400um laser beam in rain focus sacred ground surroundings cellular tissue without vitiation me by evaporation Poe of very small floor as is clean steam can . Application is possible to vulva cuticle cousins by a paternal aunt quantity, uterine cancer, cuticle tumor by laser system that $CO_2$ laser gets into standard in obstetrics and gynecology application. Because effect that super pulse output is ten enemies of laser if uniformity one pulse durations are short almost is decreased, most of all pulse module special quality of Pulse style $CO_2$ laser for obstetrics and gynecology mode stabilization by weight very, in this research to get into short pulse duration and higher frequency density, do switching by high frequency in DC-DC Converter output DC's ripple high frequency to be changed, high frequency done current ripple amount of condenser for output filter greatly reduce can . Ripple of output approximately to Zero realization applying possible inductor realization through a special quality experiment do.

  • PDF

Study on Determination of Boron using the PGAA Facility at HANARO Research Reactor (하나로의 즉발감마선 방사화분석 장치를 이용한 붕소의 정량에 대한 연구)

  • Chung, Young-Sam;Cho, Hyun-Jae;Moon, Jong-Hwa;Kim, Sun-Ha;Kim, Young-Jin
    • Analytical Science and Technology
    • /
    • v.16 no.5
    • /
    • pp.391-398
    • /
    • 2003
  • Basic research for the determination of boron content in biological sample has been carried out using the PGAA facility of the 24MW research reactor(HANARO). For investigation of characteristics for the measurement condition, neutron flux and its homogeneity were measured at irradiating geometry. The size of thermal neutron beam collimated from beam guide is $2{\times}2cm^2$ at the sample position. The neutron flux measured was the range of $1.0{\sim}6.5{\times}10^7n{\cdot}cm^{-2}{\cdot}s^{-1}$, and flux distribution from center within the radius of 4.5 mm and 9.0 mm was $5.77{\pm}0.71{\times}10^7n{\cdot}cm^{-2}{\cdot}s^{-1}$ and $4.68{\pm}1.64{\times}10^7n{\cdot}cm^{-2}{\cdot}s^{-1}$, respectively. Accordingly, sample size is adjusted within 10 mm for a homogeneous irradiation of high quality. Measurement system is designed to reduce the background source by Compton scattering and to improve the analytical sensitivity. To investigate the energy calibration and Compton suppression effect of gamma-ray counting system, the background conditions on both of Compton and single-mode were measured using NaCl standard. On the other hand, degree of spectral interference for sodium 472 keV peak as a matrix effect in the sample is established for an accurate boron analysis, and then boron content in three certified reference materials (NIST SRM 1570a, 1547, 1573a) was measured by using two modes and the results were compared with each other.

Evaluation of Scatter Reduction Effect of the Aft-Multiple-Slit (AMS) System Using MC Simulation (MC 시뮬레이션을 이용한 Aft-Multiple-Silt 시스템의 산란선 제거 효과 평가)

  • Chang, Jin-A;Suh, Tae-Suk;Jang, Doh-Yun;Jang, Hong-Seok;Kim, Si-Yong
    • Radiation Oncology Journal
    • /
    • v.28 no.4
    • /
    • pp.224-230
    • /
    • 2010
  • Purpose: We designed the aft-multiple-slit (AMS) system to reduce scatter in cone-beam computed tomography (CBCT). As a preliminary study, we performed a Monte Carlo N-Particle Transport Code (MCNP) simulation to verify the effectiveness of this system. Materials and Methods: The MCNPX code was used to build the AMS geometry. An AMS is an equi-angled arc to consider beam divergence. The scatter-reduced projection images were compared with the primary images only and the primary plus scatter radiation images with and without AMS to evaluate the effectiveness of scatter reduction. To obtain the full 2 dimensional (2D) projection image, the whole AMS system was moved to obtain closed septa of the AMS after the first image acquisition. Results: The primary radiation with and without AMS is identical to all the slit widths, but the profiles of the primary plus scattered radiation varied according to the slit widths in the 2D projection image. The average scatter reduction factors were 29%, 15%, 9%, and 8% when the slit widths were 5 mm, 10 mm, 15 mm, and 20 mm, respectively. Conclusion: We have evaluated the scatter reduction effect of the AMS in CBCT imaging using the Monte Carlo (MC) simulations. A preliminary study based on the MCNP simulations showed a mount of scatter reduction with the proposed system.

A Study on the Implementation of an Agile SFFS Based on 5DOF Manipulator (5축 매니퓰레이터를 이용한 쾌속 임의형상제작시스템의 구현에 관한 연구)

  • Kim Seung-Woo;Jung Yong-Rae
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.42 no.1
    • /
    • pp.1-11
    • /
    • 2005
  • Several Solid Freeform Fabrication Systems(SFFS) are commercialized in a few companies for rapid prototyping. However, they have many technical problems including the limitation of applicable materials. A new method of agile prototyping is required for the recent manufacturing environments of multi-item and small quantity production. The objectives of this paper include the development of a novel method of SFFS, the CAFL/sup VM/(Computer Aided Fabrication of Lamination for Various Material), and the manufacture of the various material samples for the certification of the proposed system and the creation of new application areas. For these objectives, the technologies for a highly accurate robot path control, the optimization of support structure, CAD modeling, adaptive slicing was implemented. However, there is an important problem with the conventional 2D lamination method. That is the inaccuracy of 3D model surface, which is caused by the stair-type surface generated in virtue of vertical 2D cutting. In this paper, We design the new control algorithm that guarantees the constant speed, precise positioning and tangential cutting on the 5DOF SFFS. We develop the tangential cutting algorithm to be controlled with constant speed and successfully implemented in the 5DOF CAFL/sup VM/ system developed in this paper. Finally, this paper confirms its high-performance through the experimental results from the application into CAFL/sup VM/ system.

A Parametric Study of Pulsed Gamma-ray Detectors Based on Si Epi-Wafer (실리콘 에피-웨이퍼 기반의 펄스감마선 검출센서 최적화 연구)

  • Lee, Nam-Ho;Hwang, Young-Gwan;Jeong, Sang-Hun;Kim, Jong-Yeol;Cho, Young
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.7
    • /
    • pp.1777-1783
    • /
    • 2014
  • In this paper, we designed and fabricated a high-speed semiconductor sensor for use in power control devices and analyzed the characteristics with pulsed radiation tests. At first, radiation sensitive circular Si PIN diodes with various diameters(0.1 mm ~5.0 mm) were designed and fabricated using Si epitaxial wafer, which has a $42{\mu}m$ thick intrinsic layer. The reverse leakage current of the diode with a radius of 2 mm at a reverse bias of 30 V was about 20.4 nA. To investigate the characteristic responses of the developed diodes, the pulsed gamma-radiation tests were performed with the intensity of 4.88E8 rad(Si)/sec. From the test results showing that the output currents and the rising speeds have a linear relationship with the area of the sensors, we decided that the optimal condition took place at a 2 mm diameter. Next, for the selected 2 mm diodes, dose rate tests with a range of 2.47E8 rad(Si)/sec to 6.21E8 rad(Si)/sec were performed. From the results, which showed linear characteristics with the radiation intensity, a large amount of photocurrent over 60mA, and a high speed response under 350ns without saturation, we can conclude that the our developed PIN diode can be a good candidate for the sensor of power control devices.

Polymer Optical Microring Resonator Using Nanoimprint Technique (나노 임프린트 기술을 이용한 폴리머 링 광공진기)

  • Kim, Do-Hwan;Im, Jung-Gyu;Lee, Sang-Shin;Ahn, Seh-Won;Lee, Ki-Dong
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.4
    • /
    • pp.384-391
    • /
    • 2005
  • A polymer optical microring resonator, which is laterally coupled to a straight bus waveguide, has been proposed and demonstrated using a nanoimprint technique. The propagation loss of the ring waveguide and the optical power coupling between the ring and bus waveguides was calculated by using a beam propagation method, then the dependence of the device performance on them was investigated using a transfer matrix method. We have especially introduced an imprint stamp incorporating a smoothing buffer layer made of a silicon nitride thin film. This layer played an efficient role in improving the sidewall roughness of the waveguide pattern engraved on the stamp and thus reducing the scattering loss. As a result the overall Q factor of the resonator was greatly increased. Also it reduced the gap between the ring and bus waveguides effectively to enhance the coupling between them, without relying on the direct writing method based on an e-beam writer. As for the achieved device performance at the wavelength of 1550 nm, the quality factor, the extinction ratio, and the free spectral range were ~103800, ~11 dB, and 1.16 m, respectively.

Creep Behaviours of 9% Ni Alloy (Ni 합금강의 크리프 거동)

  • Hwang, Kyung-Choong;Kim, Jong-Bae;Kang, Sung Soo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.4
    • /
    • pp.89-94
    • /
    • 2008
  • Purpose: To observe the high temperature creep test and the fracture surface of the samples of 9% Ni alloy steel generally used for all kinds of mahine parts and predict the durability of that by determining a constant of C with a Larson-Miller variable. Methods: The equipment of this test was made into lever-beam style designed by Andrade and F. Garofalo et al.. The condition of creep test was set under 16 kinds of conditions after fixing 4 kinds of temperature condition and 4 kinds of stress condition to check how it effects the samples. Results: The temperature of creep test was increased, the stress index (n) of creep deformation was gradually decreased from 3.97 to 3.55. The activation energy of creep deformation was decreased from 90.39 to 83.64 kcal/mol when the stress was increased. A constant of C value by calculation of larson-Miller variable was about 22 and if temperature for use is suggested, the durability could be calculated. Conclusions: By analyzing the fracture phenomenon and suggesting the observation result of the fracture surface of the samples and creep test of 9% Ni alloy steel, the basic design data for the practical use of accessories in the field of equipment could be constructed and used to predict the durability of the equipment.

  • PDF

Pulsed Laser System of Ultra-scan Way for Uterus Rehabilitation Treatment (자궁 재활치료를 위한 울트라-스캔 방식의 펄스형 레이저시스템)

  • Kim, Whi-Young
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.6
    • /
    • pp.256-265
    • /
    • 2009
  • Laser output becomes output adjustment from 20 w to 100 w consecutively and time of exposure is available adjustment through water plant in 0.01 seconds. Pulse action can intercept laser beam periodically and supermarket pulse 0.1 $\sim$ between 1ms discharge consist and momentary laser output is increased to 5 $\sim$ 10. Specially, that must remove malignancy cell in womb nine escarps in the case of uterine cancer first of all stability of tube output about pulse by weight very, stable soft switching action area is defined without high frequency transformer leakage inductance ($L_1$) increase and additional series inductor insertion to converter the first main circuit securing zero voltage and marks of switching action in this research specially, because circulation current path of inductor ($L_f$) current is intercepted, converter the first main circuit switching component and spiritual enlightenment damage of high frequency transformer take decreasing greatly and high frequency the second stoppage department ($D_5,\;D_6$) becomes soft switching, and also, switching damage absorption quantity characteristic that can come to life again as subordinate have, and to become tube stabilization design and result that manufacture and experiment, brought result that improve of 10% than existing equipment, and if supplement as systematic late, it becomes thought to get into superior result.

Development of Fiber-end-cap Fabrication Equipment (대구경 광섬유 엔드캡 제작장비 개발)

  • Lee, Sung Hun;Hwang, Soon Hwi;Kim, Tae Kyun;Yang, Whan Seok;Yoon, Yeong Gap;Kim, Seon Ju
    • Korean Journal of Optics and Photonics
    • /
    • v.32 no.2
    • /
    • pp.49-54
    • /
    • 2021
  • In this paper, we design and construct the equipment to manufacture large-diameter optical fiber end caps, which are the core parts of high-power fiber lasers, and we fabricate large-diameter optical fiber end caps using the home-made equipment. This equipment consists of a CO2 laser as a fusion-splice heat source, a precision stage assembly for transferring the position of a large-diameter optical fiber and an end cap, and a vision system used for alignment when the fusion splice is interlocked with the stage assembly. The output of the laser source is interlocked with the stage assembly to control the output, and the equipment is manufactured to align the polarization axis of the large-diameter polarization-maintaining optical fiber with the vision system. Optical fiber end caps were manufactured by laser fusion splicing of a large-diameter polarization-maintaining optical fiber with a clad diameter of 400 ㎛ and an end cap of 10×5×2 ㎣ (W×D×H) using home-made equipment. Signal-light insertion loss, polarization extinction ratio, and beam quality M2 of the fabricated large-diameter optical fiber end caps were measured to be 0.6%, 16.7 dB, and 1.21, respectively.