• Title/Summary/Keyword: 빔형성

Search Result 790, Processing Time 0.033 seconds

Surface Electrode Modification and Improved Actuation Performance of Soft Polymeric Actuator using Ionic Polymer-Metal Composites (이온성고분자-금속복합체를 이용한 유연고분자 구동체의 표면특성 개선과 구동성 향상)

  • Jung, Sunghee;Lee, Myoungjoon;Song, Jeomsik;Lee, Sukmin;Mun, Museoung
    • Applied Chemistry for Engineering
    • /
    • v.16 no.4
    • /
    • pp.527-532
    • /
    • 2005
  • Ionic polymer metal composites (IPMC) are soft polymeric smart materials having large displacement at low voltage in air and water. The polymeric electrolyte actuator consists of a thin and porous membrane and metal electrodes plated on both faces, in impregnation electro-plating method. The response and actuation of actuator are governed. Among many factors governing the activation and response of IPMC actuator, the surface electrode plays an important role. In this study, the well-designed modification of electrode surface was carried out in order to improve the chemical stability well as electromechanical characteristics of the IPMC actuator. We employed Ion Beam Assisted Deposition (IBAD) method to prepare the topologically homogeneous thin surface electrode. After roughing the surface of Nafion membrane in order to get a larger surface area, the IPMC was prepared by impregnation for electro-plating and re- coating on the surface through traditional chemical deposition, followed by an additional surface treatment with high conductive metals with IBAD. It was observed that our IPMC specimen shows the enhanced surface electrical properties as well as the improved actuation and response characteristics under applied electric field.

Geophysical study on the summit of the Dokdo volcano (독도화산체 정상부에 대한 지구물리학적 조사 연구)

  • Kim, Chang-Hwan;Jeong, Eui-Young;Park, Chan-Hong;Jou, Hyeong-Tae;Lee, Seung-Hoon;Kim, Ho
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.207-212
    • /
    • 2008
  • Bathymetry, side scan sonar, and magnetic survey data for the summit area of Dokdo obtained by Korea Ocean Research & Development Institute in 1999, 2004, and 2007 were analyzed to investigate the geophysical characteristics of the summit. Bathymetry and topographic data for the summit of Dokdo show uneven seabed and irregular undulations from costal line to -90 m in water depth, indicating the effects of partial erosions and taluses. The stepped slope in the bathymetry is supposed to be a coastal terrace suggesting repetition of transgressions and regressions in the Quaternary. The bathymetry and the side scan sonar data show a small crater, assumed to be formed by post volcanisms, at depth of $-100\;{\sim}\;-120\;m$ in the northeastern and the northwestern parts of the survey area. Except some areas with shallow sand sedimentary deposits, there are rocky seafloor and lack of sediments in the side scan sonar images of the survey area, dominantly. The analytic signal of the magnetic anomaly coincides with other geophysical results regarding to the location of the residual crater. The geophysical constraints of the summit of Dokdo propose that the islets and the rocky seabed elongated northeastward and northwestward from the islets might be the southern crater of the Dokdo volcano.

  • PDF

DEVELOPMENT OF PASSENGER SAFETY BOARD FOR RAILWAY VEHICLE USE

  • Mun Hyung-Suk;Eum Ki-Young;Koo Dong-Hoe
    • Proceedings of the KSR Conference
    • /
    • 2003.10c
    • /
    • pp.287-294
    • /
    • 2003
  • There are a lot of curved subway stations in Seoul metropolitan area. These must be straightly constructed as many as possible. But some of stations are roundly designed and built in order to avoid pre-existed underground obstacle such as basement of high rise building, underground gas or water pipe line and subway stations from another line. As shown fig 1, one of the biggest problem occurring curved subway station is considered large gap between platform and vehicle when vehicle completely stop at the station. The gap potentially is in existence to subway passenger as very dangerous factors in rush hours. If passenger accidentally drop their food or leg between this gap when they get on the train and train leaves station, the passenger will be seriously injured by vehicle. In this paper, various design and instruments are introduced and best solution for this matter will be presented. In order to eliminate any possibility of accident happened gap between platform and vehicle, KRRI(Korea Railroad Research Institute) have been developed new safety instrument. These technologies were applied for patent by KRRI. These mechanisms will provide confidence as well as safety to Korean subway passenger

  • PDF

Comparative Study of Optimization Algorithms for Designing Optimal Aperiodic Optical Phased Arrays for Minimal Side-lobe Levels (비주기적 광위상배열에서 Side-lobe Level이 최소화된 구조 설계를 위한 최적화 알고리즘의 비교 연구)

  • Lee, Bohae;Ryu, Han-Youl
    • Korean Journal of Optics and Photonics
    • /
    • v.33 no.1
    • /
    • pp.11-21
    • /
    • 2022
  • We have investigated the optimal design of an aperiodic optical phased array (OPA) for use in light detection and ranging applications. Three optimization algorithms - particle-swarm optimization (PSO), a genetic algorithm (GA), and a pattern-search algorithm (PSA) - were employed to obtain the optimal arrangement of optical antennas comprising an OPA. The optimization was performed to obtain the minimal side-lobe level (SLL) of an aperiodic OPA at each steering angle, using the three optimization algorithms. It was found that PSO and GA exhibited similar results for the SLL of the optimized OPA, while the SLL obtained by PSA showed somewhat different features from those obtained by PSO and GA. For an OPA optimized at a steering angle <45°, the SLL value averaged over all steering angles increased as the angle of optimization decreased. However, when the angle of optimization was larger than 45°, low average SLL values of <13 dB were obtained for all three optimization algorithms. This implies that an OPA with high signal quality can be obtained when the arrangement of the optical antennas is optimized at a large steering angle.

가족과 함께하는 창의성 경진대회 평가연구

  • 송규운;황동주;윤정진
    • Journal of Gifted/Talented Education
    • /
    • v.11 no.2
    • /
    • pp.127-150
    • /
    • 2001
  • The upcoming century is a knowledge based society which did not exist before which requires creative ability to solve problems. Therefore, it is necessary to Provide a creative program of problem solution in order to match this global trend The creativity of problem solution means the ability to solve a problem using previous ideas in an advanced way or develop new ideas. Creative education is especially important for infants. Because the young mind is where fresh ideas preside and can frame-work the early stage of life like a blank sheet of paper. The Infant-Early Child Creative Development Institute. as an adhesive institute at Yeungjin College, develops various programs that integrate methods which match current trend in this era and also start the Creative Promotion Test with 2,000 Families for the expansion of creative education from the baseline as an alternative method. The infants tested in the creative test will find ways of problem solution through animation beam projects for their given situation and also discuss the problems with their family members. Through these processes the infant and family members will complete the creative structures to solve the problems using limited materials given by the institute, and the final product will be evaluated as objective results. The final evaluation of the test will also be considered the teamwork of family cooperation and the attitudes of participants as well as the product of problem solution. The criterion of the evaluation is to be considered both a creative way of thinking and creative attitudes. Because the score counts were conducted manually it delayed the selection of awarded students who took the test. Also, we found that some parents have difficulty in accessing information to find the score through homepage from the computer. this Problem might be corrected in the future plan. Like Freud's saying, if human character and exploring attitudes during the early stage of a child, a person's creativity is composed their infant period as their basic foundation. Therefore, the family wh first environment the infant encounters will be treated as a prima when making basic structure. From this viewpoint, this creative test work as a festival of creativity fare with 2,000 families.

  • PDF

Effect of Substrata Surface Energy on Light Scattering of a Low Loss Mirror (기판의 표면에너지가 반사경의 산란에 미치는 영향)

  • Lee, Beom-Sik;Yu, Yeon-Serk;Lee, Jae-Cheul;Hur, Deog-Jae;Cho, Hyun-Ju
    • Korean Journal of Optics and Photonics
    • /
    • v.18 no.6
    • /
    • pp.452-460
    • /
    • 2007
  • Ultra-low loss ZERODUR and fused silica mirrors were manufactured and their light scattering characteristics were investigated. For this purpose, ZERODUR and fused silica substrates were super-polished by the bowl feed method. The surface roughness were 0.292 ${\AA}$ and 0.326 ${\AA}$ in rms for ZERODUR and fused silica, respectively. To obtain the high reflectivity, 22 thin film layers of $SiO_2$ and $Ta_2O_5$ were deposited by Ion Beam Sputtering. The measured light scattering of ZERODUR and fused silica mirror were 30.9 ppm and 4.6 ppm, respectively. This shows that the substrate surface roughness is not the only parameter which determines the light scattering of the mirror. In order to investigate the mechanism for additional light scattering of the ZERODUR mirror, the surface roughness of the mirror was measured by AFM and was found to be 2.3 times higher than that of the fused silica mirror. It is believed that there is some mismatch at the interface between the substrate and the first thin film layer which leads to the increased mirror surface roughness. To clarify this, the contact angle measurements were performed by SEO 300A, based on the Giriflaco-Good-Fowkes-Young method. The fused silica substrates with 0.46 ${\AA}$ in its physical surface roughness shows lower contact angle than that of the ZERODUR substrate with 0.31 ${\AA}$. This indicates that the thin film surface roughness is determined by not only its surface roughness but also the surface energy of the substrate, which depends on the chemical composition or crystalline orientation of the materials. The surface energy of each substrate was calculated from a contact angle measurement, and it shows that the higher the surface energy of the substrate, the better the surface roughness of the thin film.

Reliability of a Cobalt Silicide on Counter Electrodes for Dye Sensitized Solar Cells (코발트실리사이드를 이용한 염료감응형 태양전지 상대전극의 신뢰성 평가)

  • Kim, Kwangbae;Park, Taeyeul;Song, Ohsung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.4
    • /
    • pp.1-7
    • /
    • 2017
  • Cobalt silicide was used as a counter electrode in order to confirm its reliability in dye-sensitized solar cell (DSSC) devices. 100 nm-Co/300 nm-Si/quartz was formed by an evaporator and cobalt silicide was formed by vacuum heat treatment at $700^{\circ}C$ for 60 min to form approximately 350 nm-CoSi. This process was followed by etching in $80^{\circ}C$-30% $H_2SO_4$ to remove the cobalt residue on the cobalt silicide surface. Also, for the comparison against Pt, we prepared a 100 nm-Pt/glass counter electrode. Cobalt silicide was used for the counter electrode in order to confirm its reliability in DSSC devices and maintained for 0, 168, 336, 504, 672, and 840 hours at $80^{\circ}C$. The photovoltaic properties of the DSSCs employing cobalt silicide were confirmed by using a simulator and potentiostat. Cyclic-voltammetry, field emission scanning electron microscopy, focused ion beam scanning electron microscopy, and energy dispersive spectrometry analyses were used to confirm the catalytic activity, microstructure, and composition, respectively. The energy conversion efficiency (ECE) as a function of time and ECE of the DSSC with Pt and CoSi counter electrodes were maintained for 504 hours. However, after 672 hours, the ECEs decreased to a half of their initial values. The results of the catalytic activity analysis showed that the catalytic activities of the Pt and CoSi counter electrodes decreased to 64% and 57% of their initial values, respectively(after 840 hours). The microstructure analysis showed that the CoSi layer improved the durability in the electrolyte, but because the stress concentrates on the contact surface between the lower quartz substrate and the CoSi layer, cracks are formed locally and flaking occurs. Thus, deterioration occurs due to the residual stress built up during the silicidation of the CoSi counter electrode, so it is necessary to take measures against these residual stresses, in order to ensure the reliability of the electrode.

Active Inferential Processing During Comprehension in Poor Readers (미숙 독자들에 있어 이해 도중의 능동적 추리의 처리)

  • Zoh Myeong-Han;Ahn Jeung-Chan
    • Korean Journal of Cognitive Science
    • /
    • v.17 no.2
    • /
    • pp.75-102
    • /
    • 2006
  • Three experiments were conducted using a verification task to examine good and poor readers' generation of causal inferences(with because sentences) and contrastive inferences(with although sentences). The unfamiliar, critical verification statement was either explicitly mentioned or was implied. In Experiment 1, both good and poor readers responded accurately to the critical statement, suggesting that both groups had the linguistic knowledge necessary to the required inferences. Differences were found, however, in the groups' verification latencies. Poor, but not good, readers responded faster to explicit than to implicit verification statements for both because and although sentences. In Experiment 2, poor readers were induced to generate causal inferences for the because experimental sentences by including fillers that were apparently counterfactual unless a causal inference was made. In Experiment 3, poor readers were induced to generate contrastive inferences for the although sentences by including fillers that could only be resolved by making a contrastive inference. Verification latencies for the critical statements showed that poor readers made causal inferences in Experiment 2 and contrastive inferences in Experiment 3 doting comprehension. These results were discussed in terms of context effect: Specific encoding operations performed on anomaly backgrounded in another passage would form part of the context that guides the ongoing activity in processing potentially relevant subsequent text.

  • PDF

Research for Lateral Penumbra and Dose Distribution When Air Gap Changing in Proton Therapy Case (양성자치료시 Air Gap 변화에 따른 Lateral Penumbra와 선량분포 변화에 대한 비교 및 연구)

  • Kim, Jae-Won;Sim, Jin-Seob;Jang, Yo-Jong;Kang, Dong-Yun;Choi, Gye-Suk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.1
    • /
    • pp.47-51
    • /
    • 2010
  • Purpose: In the treatment of high-energy protons Air gap (the distance between the patient and the exit Beam) Lateral Penumbra of the changes to the increase in the radiation fields can form unnecessary and Increase the maximum dose at the site of treatment and reduced the minimum dose homogeneity of dose distributions can decline. Air gap due to this change in dose distribution compared to investigate studied. Materials and Methods: Received proton therapy at our institution Lung, Liver patients were selected and the size of six other Air gap in Field A and Field B 2, 4, 6, 8, 10 cm Proton external beam planning system by setting up a treatment plan established. Air gap according to the Lateral Penumbra area and DVH (Dose Volume Histogram) to compare the maximum dose and minimum dose of PCTV areas were compared. In addition, the dose homogeneity within PCTV Homogeneity index to know the value and compared. Results: Air gap (2, 4, 6, 8, 10 cm) at each change in field size were analyzed according to the Lateral Penumbra region Field A Change in the Air gap 2~10 cm by 1.36~1.75 cm, the average continuously increased about 28.7% and Field B Change in the Air gap 2~10 cm by 1.36~1.75 cm, the average continuously increased about 31.6%. The result of DVH analysis for relative dose of the maximum dose According to Air gap 2~10 cm is the mean average of 110.3% from 108.1% to a sustained increased by approximately 2.03% and The average relative dose of minimum dose is the mean average of 93.9% percent to 90.8 percent from the continuous decrease of about 3.31 percent. The result of Homogeneity index value to the according to Air gap 2~10 cm is the 2-fold increase from 1.09 to 2.6. Conclusion: In proton therapy case, we can see the increasing of lateral penumbra area when airgap getting increase. And increasing of Dmax and decreasing Dmin in the field are making increase homogeneity index, So we can realize there are not so good homogeneity in the PCTV. Therefore we should try to minimize air gap in proton therapy case.

  • PDF

Analysis on the Dosimetric Characteristics of Tangential Breast Intensity Modulated Radiotherapy (유방암의 접선 세기조절 방사선치료 선량 특성 분석)

  • Yoon, Mee Sun;Kim, Yong-Hyeob;Jeong, Jae-Uk;Nam, Taek-Keun;Ahn, Sung-Ja;Chung, Wong-Ki;Song, Ju-Young
    • Progress in Medical Physics
    • /
    • v.23 no.4
    • /
    • pp.219-228
    • /
    • 2012
  • The tangential breast intensity modulated radiotherapy (T-B IMRT) technique, which uses the same tangential fields as conventional 3-dimensional conformal radiotherapy (3D-CRT) plans with physical wedges, was analyzed in terms of the calculated dose distribution feature and dosimetric accuracy of beam delivery during treatment. T-B IMRT plans were prepared for 15 patients with breast cancer who were already treated with conventional 3D-CRT. The homogeneity of the dose distribution to the target volume was improved, and the dose delivered to the normal tissues and critical organs was reduced compared with that in 3D-CRT plans. Quality assurance (QA) plans with the appropriate phantoms were used to analyze the dosimetric accuracy of T-B IMRT. An ionization chamber placed at the hole of an acrylic cylindrical phantom was used for the point dose measurement, and the mean error from the calculated dose was $0.7{\pm}1.4%$. The accuracy of the dose distribution was verified with a 2D diode detector array, and the mean pass rate calculated from the gamma evaluation was $97.3{\pm}2.9%$. We confirmed the advantages of a T-B IMRT in the dose distribution and verified the dosimetric accuracy from the QA performance which should still be regarded as an important process even in the simple technique as T-B IMRT in order to maintain a good quality.