• Title/Summary/Keyword: 비 침습

Search Result 710, Processing Time 0.026 seconds

Extracorporeal High Intensity Focused Ultrasound Therapy (체외강력집속초음파치료)

  • Han, Sang-Suk
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.11 no.1
    • /
    • pp.17-24
    • /
    • 2005
  • Local treatment for tumors has developed from extended radical surgery to function preserving surgery on the basis of modern biology. With the development of minimally invasive technique, it changed to be minimal-invasive surgery. And nowadays technical revolution made non-invasive surgery possible with appearance of several kinds of non-surgical knives such as gamma knife, cyber knife, and HIFU (high intensity focused ultrasound) knife. In this article, history, HIFU machine and treatment procedure, histological change and its mechanism, clinical applications, advantage, disadvantage, and future prospect of extracorporeal high intensity focused ultrasound therapy using HIFU knife will be reviewed.

  • PDF

Design of Noninvasive Arterial Blood Pressure Measurement System by Using Double-Cuffs Oscillometric Method (이중 커프 오실로메트릭법을 이용한 비침습 동맥압 측정시스템의 설계)

  • Lee, Pil-Jae;Lee, Young-Jae;Kim, Dong-Jun;Lee, Jae-Ho;Lim, Min-Gyu;Lee, Jeong-Whan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.6
    • /
    • pp.885-890
    • /
    • 2012
  • In this study, a new blood pressure measuring system was proposed and implemented. An additional small-cuff was placed on the center of a inner cuff to measure morphological signals and new oscillometric ratio. The proposed BP-measuring system is composed of an external cuff, an inner cuff and a small-cuff. Oscillation signal from small-cuff is interpolated with 7th-order fitting polynomials and SBP, DBP ratio were 22.2% and 87.7%. Experimental data were gathered from 20 volunteers ($25{\pm}4$ years) and arterial blood pressure values were compared with auscultation, sphygmomanometers, small-cuff and inner-cuff. As a result, the difference in systolic BP between auscultation and the small-cuff was 1.93(${\pm}1.28$) mmHg, and the inner-cuff was 4.53(${\pm}4.39$) mmHg, and sphygmomanometer was 6.68(${\pm}3.99$) mmHg, and the corresponding difference in diastolic BP was 2.50(${\pm}2.04$) mmHg, 3.50(${\pm}3.19$) mmHg, 7.35(${\pm}5.62$), respectively.

The case report on pain treatment by extravascular laser system (비침습 레이저 조사기를 이용한 통증 치료에 대한 증례 보고)

  • Hwang, Young-Jun;Kim, Jang-Hyun
    • The Journal of Pediatrics of Korean Medicine
    • /
    • v.20 no.3
    • /
    • pp.51-60
    • /
    • 2006
  • Objectives : The purpose of this study was to assess the ability of Extravascular Laser System on pain treatment. Methods : On this study, we carried out with the 9 cases of children who visited in the Department of Pediatrics, OO University Oriental Hospital as pain. 9 children suffering from pain were treated with Extravascular Laser System, and two of these were treated with combined acupuncture. In order to determine the degree of pain relief, a visual analogue scale was used. Results : Extravascular Laser System for pain resulted in a significant decline in the visual analogue scale. For Extravascular Laser System combined with acupuncture, VAS score has fallen by 30% each time compared to 17.5% of Extravascular Laser System only. In 2 cases of chronic pain, VAS score decreased to 0. In 7 cases of acute pain, All of 7 children improved 50% on VAS score, On average VAS score have seen 79.2% reduction. The average treatment times of chronic pain were 5 times, while that of acute pain were 4.1 times. Conclusions : We report the good result of the efficacy of extravascular laser system on children's pain. but, this study's cases were small in number. so more study is need.

  • PDF

The Technological Concept of Fibroscan and its Clinical Usefulness in the Traditional Korean Medical Field (비침습적 간섬유화 측정기(Fibroscan)의 기술적 개요와 한의임상적 유용성 고찰)

  • Son, Chang-gue
    • The Journal of Internal Korean Medicine
    • /
    • v.36 no.2
    • /
    • pp.85-92
    • /
    • 2015
  • Objectives: The liver fibroscan has been developed as a noninvasive and convenient method to assess hepatic fibrosis. This study aimed to review this device in terms of its technological concept and clinical application in traditional Korean medicine (TKM). Methods: The technological background, diagnostic evaluation, and clinical usefulness of fibroscan were reviewed using various literature and clinical studies. One clinical example-a patient with hepatofibrosis who had been treated with TKM-is presented. Results: The liver fibroscan was approved as a medical device for noninvasive measurement of the hepatic fibrosis level by the Korean Food and Drug Administration (KFDA). Numerous clinical studies have confirmed that its sensitivity and specificity allow it to serve as a substitute for liver biopsy, the present gold standard diagnostic method. The accuracy and reproducibility and lack of technical risks are strong points of the fibroscan; however, it has some limitations for application, especially in patients with obesity or severe hepatitis. One clinical example showed the applicability of the liver fibroscan in herbal medicine-based treatments. Conclusions: The requirement for diagnostic medical devices is an important issue in TKM; therefore, this study provides valuable information for practitioners of TKM.

New Methods of Vagus Nerve Stimulation : Therapeutic Effects of Non-Invasive Vagus Nerve Stimulation by TENS Application (미주신경 자극을 위한 새로운 방법 : 비침습적 TENS 적용에 대한 미주신경 자극의 치료적 효과)

  • Kwon, Haeyeon;Moon, Hyunju
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.4 no.4
    • /
    • pp.77-82
    • /
    • 2016
  • Purpose: The purpose of this study was to investigate the therapeutic effect of non-invasive vagus nerve stimulation by transcutaneous electrical nerve stimulation application on the autonomic nervous system of human body. Methods: Participants were seventeen healthy adults. Standard deviation of all normal N-N intervals(SDNN), root mean square of successive differences(RMSSD), low frequency(LF), high frequency(HF) were compared in pre and post Mean values after intervention. Data were analyzed in Wilcoxon's signed-ranks test. Results: The results of this study is that sistolic blood pressure and pulse rate decreased mean value after non-invasive vagus nerve stimulation by transcutaneous electrical nerve stimulation. High frequency, low frequency, SDNN, RMSSD increased mean value in heart rate variability after intervention. But that is not significant except for SDNN. Conclusion: Non-invasive vagus stimulation by transcutaneous electrical nerve stimulation effect on parasympathetic nerve stimulation, and then it might be effective method for autonomic nerve balance control.

Brown Tumors Due to Parathyroid Carcinoma; $^{99m}Tc-MIBI$ Scan Findings (Case Report) (부갑상선 암종에 의해 발생한 갈색 종양: $^{99m}Tc-MIBI$ 스캔 소견 (증례 보고))

  • Kim, Su-Zy;Yoon, Soek-Nam;Kim, Byung-Soek;Chung, Yoon-Soek;Park, Chan-Hee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.31 no.3
    • /
    • pp.395-398
    • /
    • 1997
  • Whole body $^{99m}Tc-MIBI$ scan in conjunction with parathyroid scan is an effective method in detecting parathyroid lesions in patients with bone pain and possible bone lesions such as brown tumors.

  • PDF

Usefulness of Functional MRI for the study of concentration sheet (Functional MRI를 이용한 학습집중력 향상 시트 개발)

  • Kim, Chang-Gyu
    • Proceedings of the KAIS Fall Conference
    • /
    • 2009.05a
    • /
    • pp.13-17
    • /
    • 2009
  • In this thesis, we made a sheet to improve the concentration of study. To demonstrate the improvement in the concentration of study, we obtained functional magnetic resonance imaging (fMRI), which has superior time resolution and measures brain noninvasively by using intrinsic contrast agent. As a result of Brainwave measurement, we could verify the blood flow's activate in the nearby frontal lobe related to memory process and noticeable ratio change in absolute alpha wave and beta wave after the analysis of Brainwave measurement. fMRI ascertains the physiological function of the brain and is being used to prevent the trouble medically that can be caused before and after the operation. For the visibility of cranial nerve network, many researches will be carried out to develope the product which is related to brain like concentration of study.

  • PDF

Development of a Cardiovascular Index That Estimates Cardiovascular Health Degree by Survey and Noninvasive Examination (설문과 비침습적 검사를 통하여 심혈관계 건강 정도를 알려주는 심혈관지수의 개발)

  • Lee, Chong Sun;Chung, In Wook
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.31 no.5
    • /
    • pp.459-466
    • /
    • 2014
  • An index was developed that estimates cardiovascular health degree with easily available physiological information such as survey and noninvasive measurement. The survey score was calculated by utilizing questions related to personal disease history, self-feeling, and management state. The measurement score was calculated using physiological parameters such as blood pressure, accelerated plethysmograph(APG), and heart rate variability(HRV), and augmentation index(AI). In order to evaluate effectiveness of the cardiovascular index and modify weighting factors used in each item, a clinical trial was done in a general hospital. The cardiovascular index showed a clear correlation of 0.685 with the doctor's score on the cardiovascular health degree. The correlation between the self-estimated score and doctor's score was as low as 0.217. The large gap between these two scores demonstrated necessity of more objective tools like the cardiovascular index. The cardiovascular score showed a significant difference between normal persons and patients suffering hypertension or diabetes. (p=0.000).

The Relationship between Arterial and End-tidal Partial Pressures of CO$_{2}$ in Halothane-anesthetized Heavy Breed Horses with respect to Operative Positions and the Modes of Ventilation (Halothane으로 마취된 거대말에서 수술자세와 호흡방법에 따른)

  • 안경아;권오경;산권명부;권구청;산안칙부
    • Journal of Veterinary Clinics
    • /
    • v.14 no.2
    • /
    • pp.238-243
    • /
    • 1997
  • 체중이 700-750kg 인 4마리의 중종마에 70분동안 마취를 실시하여 동맥혈의 이 산화탄소 분압과 호기말 가스내의 이산화탄소 분압 사이의 관계를 관찰하였다. 마취도중 자발 호흡, 인공호흡 1(흡기시간 2.0초), 인공호흡 2(흡기시간 2.5초)를 각각 30분,20분,20분씩 실시하였으며 매 10분마다 동맥혈가스분석과 호기말 가스내 이산화탄소분압 측정을 실시하 였다. 동시에 혈압, 심전도, 체온측정을 실시하여 마취된 환축의 상태를 관찰하였다. 2주후에 자세를 달리하여(앙와에서 측와로) 같은 방법으로 재 실험하였다. 호기말 이산화탄소분압은 동맥혈에서보다 평균 10 mmHg 정도 낮은 양상을 보였으나 높은 상관관계를 보였으며 자세에 따른 유의적 차이는 업었다(앙와자세; r=0.949, 측와자세; r=0.920, P<0.01). 이러한 결과를 토 대로 조직에 창상을 줄 수 있는 동맥혈 가스분석 대신 비침습적방법인 호기말 가스내 이산화 탄소 분압을 측정하는 것이 환축의 모니터링에 효과적으로 사용 가능하다는 것을 알 수 있었다.

  • PDF

Fibro-osseous Pseudotumor of the Great Toe: A Case Report (제 1족지에 발생한 섬유골성 가종양: 1예 보고)

  • Song, Woo-Suk;Choi, Joon-Cheol;Kim, Hak-Soo;Han, Eun-Mee
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.16 no.2
    • /
    • pp.91-94
    • /
    • 2010
  • Fibro-osseous pseudotumor is an extremely rare benign lesion which is fast-growing and painful. It is often misdiagnosed as a malignancy, but it is a noninvasive entity and can be cured by simple resection. We report a case of fibro-osseous pseudotumor of the distal phalanx of great toe in 20-year-old female patient who present with painful mass.