• Title/Summary/Keyword: 비파괴탐상

Search Result 228, Processing Time 0.025 seconds

Evaluation of Near/Far Field and Directivity of Ultrasonic Transducer for Turbine Rotor Disc (터빈 로타 디스크의 초음파탐상을 위한 초음파탐촉자의 지향성 및 탐상범위)

  • Won, S.H.;Chang, H.K.;Cho, K.S.;Lee, J.O.;Lee, J.K.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.18 no.3
    • /
    • pp.163-171
    • /
    • 1998
  • Near/far field length and directivity of transducers were investigated for the improvement and evaluation of the detectability of flaws in a disc. The reference block is fabricated for the disc of stage 6 in Yonggwang unit 1. The near/far field and directivity of an ultrasonic transducer with the center frequency of 5MHz were calculated for the inspection of the disc. These values showed good agreements with the experimental results. In the system composed of a wedge and a disc, those are evaluated theoretically and experimentally for the specimen with the artificial flaws of the size 2mm and 4mm and an ultrasonic transducer with the center frequency 5MHz and diameter 0.5inch. The detectability of keyway-flaw and detectable region for inspection were evaluated by using both tangential $45^{\circ}$ and $90^{\circ}$ transducers located at the distance of 53mm and 75mm from the disc hub, respectively.

  • PDF

Finite Element Analysis of Eddy Current Testing for Tubes with 3-Dimensional Defects (3차원 관결함에 대한 와전류탐상의 유한요소해석)

  • Lee, Hyang-Beom;Won, Sung-Yean;Shin, Young-Kil
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.20 no.3
    • /
    • pp.191-199
    • /
    • 2000
  • In this paper, a numerical analysis using the finite element method (FEM) is presented which models the eddy current testing (ECT) of tubes with 3-dimensional defects. For the description of 3-dimensional eddy current problems, the governing equation is derived from the Maxwell's equations. The 3-dimensional FEM formulation with hexahedral elements is carried out using the Galerkin weighted residual method. The INCONEL 600 steam generator tube with inner and outer diameter defects is adopted for the numerical analysis, and the ECT signal, which is the trajectory of the probe impedance, is calculated. For the verification of the numerical analysis method, results of numerical calculations and experiments are compared and they show good agreements. Based on this verification, several defect signals are predicted and their characteristics are investigated with the variation in the defect depth and the circumferential angle of the defect.

  • PDF

A Feasibility Study on the Application of Ultrasonic Method for Surface Crack Detection of SiC/SiC Composite Ceramics (SiC/SiC 복합재료 세라믹스 표면균열 탐지를 위한 초음파법 적용에 관한 기초연구)

  • Nam, Ki-Woo;Lee, Kun-Chan;Kohyama, Akira
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.5
    • /
    • pp.479-484
    • /
    • 2009
  • Nondestructive evaluation(NDE) of ceramic matrix composites is essential for developing reliable ceramics for industrial applications. In the work, C-Scan image analysis has been used to characterize surface crack of SiC ceramics nondestructively. The possibility of detection of surface crack were carried out experimentally by two types of ultrasonic equipment of SDS-win and $\mu$-SDS, and three types of transducer of 25, 50 and 125 MHz. A surface micro-crack of ceramics was not detected by transducer of 25 MHz and 50 MHz. Though the focus method was detected dimly the crack by transducer of 125 MHz, the defocus method could detect the shape of diamond indenter. As a whole, the focus method and the defocus method came to the conclusion that micro crack have a good possibility for detection.

Numerical Analysis of Magnetic Flux Leakage Inspection (누설자속탐상의 수치해석)

  • Lee, Hyang-Beom;Kim, Sean
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.21 no.5
    • /
    • pp.485-492
    • /
    • 2001
  • In this paper, electro-magnetic numerical analysis of MFL(magnetic flux leakage) method is presented. For the electromagnetic numerical analysis, 2-D FEM(finite element method) is used. The magnetic vector potential is used as a variable. The analysis of the magnetic field considering the magnetic nonlinearity is performed for the effect of the magnetic salutation. For the verification of the validity of the numerical simulation results, by using the lab-made experimental setup, non-destructive inspection is performed. The SM 45C carbon steel is used as a specimen and the artificial defects are made on the specimen. The non-destructive testing for the detection of the defect is performed. The results according to the variation oi the defect depth and the defect shape are obtained. The experimental results are compared to the numerical ones, and we conclude that the numerical results are similar to the experimental ones. So the possibility of simulation of the MFL by using the numerical analysis is shown in this paper.

  • PDF

Automatic Noncontact Ultrasonic Inspection Technique (비접촉식 초음파탐상방법 자동화 기술)

  • Kim, Y.G.;Ahn, B.Y.;Lee, S.S.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.13 no.4
    • /
    • pp.25-31
    • /
    • 1994
  • A system for EMAT, which generates ultrasound by electro-magnectic forces and performs nondestructive testing in noncontact, was established. By linking it with a 3 axis scanning system and a data acquisition and processing system the automation of EMAT testing was attempted. A EMAT sensor was fabricated and the directivity pattern of it was measured. To be suitable automation, it has a transmitter and a receiver in one case and the main beam direction of it can be controlled by the frequency of driving signal. A program which controls the EMAT system, the 3 axis scanner and the data acquisition and processing system was developed. It also processes acquired data and displays the processing results. IBM-PC/AT compatible PC was used as main controller and the stratage of the program is emulation of real devices on the PC monitor. To provide the performance of the established EMAT system, two aluminium blocks containing artificial flaws and a welded aluminium block were tested. The result of the tests were satisfactory.

  • PDF

Application of Ultrasonic Testing in Offshore Structures (해양 철구조물에의 초음파 탐상시험 적용)

  • Choi, B.K.;Kim, J.H.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.11 no.1
    • /
    • pp.44-51
    • /
    • 1991
  • This paper describes the practical difficulties experienced with ultrasonic testing during site fabrication of the offshore structures, and indicates some of the problems when UT indications are evaluated according to written procedure which is prepared to the requirements of the applicable code (standard) and/or specification.

  • PDF

Nondestructive Evaluation for Grain Refinement of Aluminum Alloy of Equal-Channel Angular Pressing (ECAP 가공한 알루미늄합금의 결정립 미세화에 대한 비파괴평가)

  • Ahn, Seok-Hwan;Nam, Ki-Woo;Kim, Jin-Hwan;Kang, Suk-Bong
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.2
    • /
    • pp.132-139
    • /
    • 2002
  • The grain size of aluminum alloy was refined to the submicrometer level by using equal-channel angular pressing(ECAP). The effect of grain size refinement was evaluated by the tensile test, micro-hardness test, microstructure observations, ultrasonic test and acoustic emission test. The strength and the Vickers hardness were increased significantly according to grain size refinement after equal-channel angular pressed. The ultrasonic velocity was faster after equal-channel angular pressed, and the high frequency range appeared. The results of the ultrasonic velocity and the frequency range are expected to be basic data that can prove the grain size refinement

A study on appropriate nondestructive inspection methods of gear units for rolling stock (전동차 대치차 기어의 적절한 탐상법에 관한 연구)

  • Lee, Jae-Il;Lee, Min-Yeol;Lee, Won-Hak;Son, Young-Jin
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.571-582
    • /
    • 2010
  • Typically nondestructive inspection methods of the large gear units are applied to penetrate non-destructive inspection. Nondestructive penetrating inspection put into the small openings of the defect to penetration liquid, remove to excess penetration liquid on the surface of the gear units, spread with developing solution and we can find the small defect by coating with penetration liquid. However, this method has so many issues because of penetrate nondestructive tests on the gear assembly. The steep angle of screw is hard to achieved full penetration and has the problem to remove the excess. In contrast, the magnetic nondestructive inspection is easy to detect subsurface defects and subtle defects. According to the inspection results the stress concentrates in gear surface, some internal defects and microscopic flaws exist on the gear units are not found to penetrate the nondestructive inspection, but magnetic nondestructive inspection could have found many defect. Therefore, a reasonable method of nondestructive inspection for the large gear units is suitable to magnetic nondestructive inspection.

  • PDF

Design of the Fittest Eddy Current Probe for the Fin Tubes (Fin 튜브의 와전류탐상을 위한 최적 탐촉자의 설계)

  • Kim, Y.J.;Lee, S.K.;Ahn, B.Y.;Chung, M.H.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.17 no.3
    • /
    • pp.156-161
    • /
    • 1997
  • The eddy current probe was designed for the test of fin tubes that have uneven outer and inner surfaces to enhance the efficiency of heat emission. Because of the surface roughness of the fin tube, it needs much care to detect flaws in the tube employing eddy current test(ECT). We made ECT probes with different coil lengths and performed eddy current test using these probes for artificially flawed specimens. By the fast Fourier transform and digital filtering, signals from these probes were processed to characterize frequency spectra. From the analysis of eddy current signals and their frequency spectra, we concluded that, for the effective testing of the tubes with the fins of 1mm pitch, 4mm coil length gave the highest S/N ratio.

  • PDF

Effect on detecting signal according to transition of pipeline thickness in Magnetic Flux Leakage system (자기누설탐상시스템에서 배관의 두께 변화가 탐상신호에 미치는 영향)

  • Seo, Kang;Park, Gwan-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.643-644
    • /
    • 2006
  • 자기누설탐상시스템은 지하에 매설된 가스관에서 발생되는 부식이나 크랙 또는 기계적 변형을 탐지하기 위한 방법으로 비파괴검사 방법의 하나이다. 가스관은 Nd자석에 의해 착자가 되고, 가스관에 부식이 발생했을 경우 가스관의 단면적이 작아지게 되어 자기누설이 발생하며, 발생된 자기누설을 홀센서로 검출하여 부식의 유무, 크기, 모양 등을 판별하게 된다. 지하매설 배관은 배관의 직경은 같으나 배관의 두께는 다양하게 존재한다. 특히 30inch의 배관에는 배관의 두께가 11.1, 14.3, 17.5 mm 등이 있다. 자기누설탐상시스템은 배관의 단면적 변화를 감지하는 것이기 때문에 배관의 두께에 따라 그 특성이 변화하게 된다. 또한 두께에 따른 결함의 종류에 따라서 검출신호도 변화하게 된다. 따라서 본 논문에서는 배관의 두께 변화에 따른 검출신호를 분석하였으며, 두께 변화의 영향을 적용하여 검출신호를 보정하기 위한 방법을 제시하였다.

  • PDF