• Title/Summary/Keyword: 비침습적 검사

Search Result 226, Processing Time 0.022 seconds

Reflux Nephropathy Detected by Post-voiding Image on Scintigraphic Tc-99m MAG3 Scan (Tc-99m MAG3 Scan의 배뇨 후 배설상으로 진단된 역류성 신병증 1례)

  • Kim Hong-Guk;Yu Je-Yun;Ham Ju-Yeon;Yun Suk-Nam;Pai Ki-Soo
    • Childhood Kidney Diseases
    • /
    • v.7 no.2
    • /
    • pp.239-244
    • /
    • 2003
  • $^{99m}Tc-MAG3$ Scintigraphic Scan is sensitive at depicting focal parenchymal abnormalities and can be used for the measurement of overall renal function. We experienced a 12-year-old girl presenting with fever and flank pain. On the ultrasonogram and post-voiding delayed image of $^{99m}Tc-MAG3$ scintigraphic scan, severe right cortical atrophy and hydronephrosis with vesicoureteral reflux were detected. We could demonstrate the reflux nephropathy by these two diagnostic work-up without conventional voiding cystourethrography.

  • PDF

Factors Affecting Basilar Artery Pulsatility Index on Transcranial Doppler (뇌혈류 초음파 검사에서 기저동맥 박동지수에 영향을 미치는 인자)

  • Jeong, Ho Tae;Kim, Dae Sik;Kang, Kun Woo;Nam, Yun Teak;Oh, Ji Eun;Cho, Eun Kyung
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.50 no.4
    • /
    • pp.477-483
    • /
    • 2018
  • Transcranial doppler is a non-invasive method that measures the blood flow velocity and the direction of cerebral blood vessels through the doppler principle. The pulsatility index is an index for measuring the transcranial doppler that reflects the distal vascular resistance and is used as an index for the presence and diffusion of cerebral small vessel diseases. The purpose of this study was to evaluate the risk factors affecting the basilar artery pulsatility index in ischemic stroke patients. From January 2014 to May 2015, 422 patients were selected by measuring the transcranial doppler pulsatility index, considering their basilar artery pulsatility index. Univariate analysis was performed using the basilar artery pulsatility index as a dependent variable. Multiple regression analysis was performed considering the factors affecting the pulsatility index as variables. Univariate analysis revealed age, presence of hypertension, presence of diabetes mellitus, presence of hyperlipidemia, and hematocrit (P<0.1) as factors. Multiple regression analysis showed statistically significant results with age (P<0.001), presence of diabetes (P=0.004), and presence of hyperlipidemia (P=0.041). The risk factors affecting the basilar artery pulsatility index of transcranial doppler were age, diabetes, and hyperlipidemia. Further research will be needed to increase the cerebral pulsatility index as a surrogate marker of the elderly, diabetes, and hyperlipidemia.

Analysis of 1,000 Cases of Abdominal Ultrasonography Performed by a Pediatrician (소아과 의사에 의해 시행된 복부 초음파 검사 1,000예에 대한 분석)

  • Bae, Sang-In;Park, Jae-Hong
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.10 no.1
    • /
    • pp.28-35
    • /
    • 2007
  • Purpose: The aim of this study was to evaluate the clinical usefulness of ultrasound examination of children performed by a pediatrician. Methods: One thousand children who presented with symptoms of a gastrointestinal disorder and underwent abdominal ultrasound evaluation in the Department of Pediatrics, between January 2003 and June 2006, were included in this study. We analyzed the patient's medical records and ultrasound results retrospectively. Results: Among the 1,000 patients, 58.4% were male and 41.6% were female. The mean age of the patients was $4.7{\pm}4.0$ years. The main reasons for ultrasound were abdominal pain (43.9%), vomiting (17.3%), elevated liver enzymes (11.8%), and jaundice (9.8%). Abnormal ultrasound findings were present in 57.9% of cases. The major abnormal findings were mesenteric lymphadenitis (29.2%), fatty liver (12.1%), hepatitis (6.4%), hepatosplenomegaly (6.2%), and acute appendicitis (4.8%). The time interval between the initial medical evaluation and the ultrasound evaluation was within 24 hours in most cases (78.5%). The main findings in children with abdominal pain were mesenteric lymphadenitis (32.6%), fatty liver (5.9%), intussusception (2.7%), and acute appendicitis (2.7%). The main findings in children with vomiting were mesenteric lymphadenitis (12.7%), hypertrophic pyloric stenosis (10.4%), and acute appendicitis (3.5%). The major ultrasound findings in children with urinary tract diseases were hydronephrosis (45.4%), urolithiasis (21.5%) and cystic renal disease (18.1%). Conclusion: Ultrasound examination played an important role as a non-invasive and prompt screening examination for detection of abdominal diseases. Ultrasound was an important tool for pediatricians to determine timely information for patient management.

  • PDF

Age-Related Fecal Calprotectin Concentrations in Healthy Adults (건강한 성인의 연령별 분변 칼프로텍틴의 농도)

  • Park, Shin Young
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.52 no.3
    • /
    • pp.181-187
    • /
    • 2020
  • Fecal calprotectin (FC) is a marker used for the differential diagnosis of inflammatory bowel disease (IBD). FC is also used to determine the effects of treatment and recurrence prediction because of its non-decomposition by bacteria, relative week stability at room temperature, and its uniform distribution within feces. Healthy male and female adults between the age of 30 and 80 living in Jeju were selected for this study. The FC concentration in the healthy control group (N=45) was distributed widely as 0~545.9 ㎍/g and showed a significant difference with age in healthy adults. The FC concentration in adults over 70 years old (80.6 years on average) was 160.3 ㎍/g. The result is approximately 10 times higher than in adults below 50 years (44 years on average), with FC concentrations at 15.88 ㎍/g. Moreover, adults over 50 years, with an average age of 59.6, had FC concentrations of 35.46 ㎍/g, which were two times higher than the below 50-year-old group, confirming the significant correlation between age and FC concentration. As the FC test is a non-invasive and cost-effective objective marker in IBD tests, a suitable cut-off value is required for different ages. This study provides the baseline data for differential diagnoses.

Development of the Screening Tool for Risk of Preterm Birth in Pregnant Women (임신부의 조산위험 선별도구 개발)

  • Cho, Mi-Ock;Kim, Jeung-Im
    • Journal of Digital Convergence
    • /
    • v.18 no.6
    • /
    • pp.335-344
    • /
    • 2020
  • This study was to develop a screening tool to identify the pregnant women who are required to have a concrete checkup or education about preterm birth. The items for the screening tool were drafted from literature review and the result of interviews with women who are hospitalized after preterm delivery based on the biopsychosocial framework. The validity and reliability of the items was performed after the content validity and the pilot survey. The screening tool for the risk of preterm birth in pregnant women was consisted of two parts. One was consisted of 9-items for the biomedical risks and another one was consisted of 17-items for the psycho-physical risks. The screening tool for the risk of preterm birth in pregnant women reveals valid and reliable. It could be applied to identify the pregnant women who have some risks of preterm birth.

Near-Infrared Spectroscopy for Monitoring Cerebral Hemodynamics in Hyperbilirubinemia-induced Newborn Piglets (고빌리루빈혈증이 유도된 신생자돈에서 근적외석 발광기를 이용한 뇌 혈역학적 변화에 대한 연구)

  • Hwang, Jong Hee;Choi, Chang Won;Chang, Yun Sil;Park, Won Soon
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.6
    • /
    • pp.649-654
    • /
    • 2005
  • Purpose : The present study examined how changes in cerebral hemodynamics in newborn piglets with bilirubin infusion can be evaluated by near infrared sepctroscopy(NIRS). Methods : Seventeen newborn piglets were randomly divided into the following three experimental groups : six in the control group(CG); seven in the bilirubin infusion group(BG), and four in the bilirubin infusion with 7-nitroindazole group(NG). To achieve the concentration of bilirubin above 20 mg/dL, we injected a bolus of 40 mg/kg of bilirubin intravenously, followed by 30 mg/kg/hr of bilirubin continuous intravenous infusion. All groups were monitored with cerebral hemodynamics using near infrared spectroscopy(NIRS) and their brain cortexes were harvested and the activities of $Na^+$, $K^+$-ATPase, level of conjugated dienes, ATP and phosphocreatine(PCr) were determined biochemically. Results : No changes took place in CG. In BG and NG, base excess, pH, and MABP decreased, and lactate level in blood increased. Cerebral $Na^+$, $K^+$-ATPase activity and ATP, PCr level in BG significantly decreased and conjugated dienes increased compared to CG. These abnormalities observed in the BG were significantly improved in the NG. In continuous NIRS monitoring, [$HbO_2$], [HbT], and [HbD] in BG were significantlly decreased compared to CG. However these abnormalities between NG and CG were not significantly different. There were no significant differences in $ScO_2$ between the study groups. Conclusion : Our study suggests cerebral hemodynamic changes could be monitored by non-invasive NIRS in newborn piglets with bilirubin infusion.

Diagnosis of Diabetes Using Voltage Analysis Based on EIS (Electro Interstitial Scan) (EIS 기반 전압신호 분석을 통한 당뇨병 진단 가능성 평가)

  • Bae, Jang-Han;Kim, Soochan;Kaewkannate, Kanitthika;Jun, Min-Ho;Kim, Jaeuk U.
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.11
    • /
    • pp.114-122
    • /
    • 2016
  • EIS (Electro interstitial scan) is a non-invasive and simple method to find the physio-pathological information inferred by electric current response with respect to low direct current applied between remote sites of the body. Although a few EIS-based devices for diagnosing diabetes were commercialized, they were not successful in offering clinical validity nor in confirming diagnostic principle. In this study, we measured the voltage responses of diabetic patients and normal subjects with a commercialized EIS device to test the usefulness of EIS in screening diabetes. For this purpose, voltage was measured between pairs of electrodes contacted at both palm, both soles of the feet and left and right forehead above both eyes. After feature extraction of voltage signals, the AUC (area under the curve) between the two groups was calculated and we found that seven variables were appropriately shown above 60% of accuracy. In addition, we applied the k-NN (k-nearest neighbors) method and found that the accuracy of classification between the two groups reached the accuracy of 76.2%. This result implies that the voltage response analysis based on EIS has potential as a diabetics screening method.

Atypical Manifestation of Primary Hepatocellular Carcinoma and Hepatic Malignancy Mimicking Lesions (원발성 간세포암의 비특이적 영상 소견 및 간암으로 오인될 수 있는 병변에 대한 영상의학적 고찰)

  • Jiyoung Yoon;So Hyun Park;Su Joa Ahn;Young Sup Shim
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.4
    • /
    • pp.808-829
    • /
    • 2022
  • Hepatocellular carcinoma (HCC) can be diagnosed noninvasively on multiphasic CT and MRI based on its distinctive imaging findings. These features include arterial phase hyperenhancement and washout on portal or delayed phase images. However, radiologists face significant diagnostic challenges because some HCCs exhibit atypical imaging characteristics. In addition to many HCC-mimicking lesions, such as arterioportal shunts, combined HCC-cholangiocarcinoma, intrahepatic cholangiocarcinoma, and hemangioma present a challenge for radiologists in actual clinical practice. The ability to distinguish HCCs from mimickers on initial imaging examinations is crucial for appropriate management and treatment decisions. Therefore, this pictorial review presents the imaging findings of atypical HCCs and HCCs mimicking malignant and benign lesions and discusses important clues that may help narrow down the differential diagnosis.

Ultrasonographic Evaluation in Patients with Inguinal Hernia (서혜부 탈장에서의 초음파 조영술)

  • Kwon, Oh-Kyoung;Jung, Jin-Hyang;Park, Jin-Young;Chang, Soo-Il
    • Advances in pediatric surgery
    • /
    • v.8 no.1
    • /
    • pp.16-22
    • /
    • 2002
  • Between March 1999 and January 2000, 82 boys with the diagnosis of inguinal hernias (12 bilateral and 70 unilateral hernias), underwent Ultrasound (US) examination of both sides of the groin, a total of 164 inguinal imaging prior to surgery. The patients ages ranged from 3 days to 12 years with a mean of 32.6 months. Ninty four examinations were on the clinically symptomatic side and 70 were on the asymptomatic side. The US criteria for the diagnosis of an inguinal hernia were as follows: 1) visceral hernia, the presence of bowel loops, or omentum in the inguinal canal, 2) communicating hydrocele, the presence of fluid in the processus vaginalis, 3) widening of patent processus vaginalis at the level of internal inguinal ring. The width of patent processus vaginalis at the level of internal inguinal ring over 4 mm is considered an occult hernia. Among the 94 symptomatic groins, US findings showed 31 (33%) visceral hernias, 18 (19%) communicating hydroceles, and 38 (41%) widening of the internal inguinal ring, and 7 (7%) groins without abnormalities. In 70 asymptomatic groins, there were 4 (6%) visceral hernias, 5 (7%) communicating hydroceles, 11 (16%) widening of the internal inguinal ring, and 50 (70%) groins without abnormalities. Among the 70 asymptomatic groins there were US abnormalities in 20 (28%). One hundred and seven groins with positive US findings were surgically explored. Among 107 operated sites, the operative findings were compatible with the US diagnosis in 104, a sensitivity for US of 97.2%. In patients with US findings of widening of internal inguinal ring (>4 mm), there was patent processus vaginalis in 36 out of 38 symptomatic groins and 10 of 11 asymptomatic groins. The sensitivity of US to the operative findings in widening of internal inguinal ring was 93.8%. For visceral hernia and communicating hydrocele, the sensitivity of positive US findings was 100%. Ultrasonography for inguinal hernias appears to be a rapid, reliable, and noninvasive screening diagnostic tool with high positive specificity. Therefore, we recommend the use of US as a routine diagnostic tool in pediatric patients with inguinal hernias and hydroceles.

  • PDF

A Non-invasive Measurement of Abdominal Pressure on Ambulatory Urodynamics Study Using Surface Electromyography (휴대용 요역동학 검사 시 근전도 신호를 이용한 복압측정 방법)

  • Kim, Keo-Sik;Song, Chul-Gyu;Seo, Jeong-Hwan
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.45 no.6
    • /
    • pp.132-140
    • /
    • 2008
  • Conventional rectal catheters which are used for the measurement of abdominal pressure can cause erroneous result affecting detrusor pressure, and the catheter itself is not comfortable to the patients. To reduce these problems, we invented a new method for measuring abdominal pressure in non invasive manner using surface electromyography (EMG) signals of the rectus abdominis muscle. Our results showed that the correlation coefficient and root mean square error (RMSE) between the measured abdominal pressures by the conventional rectal catheters and the estimated values by our proposed algorithm were $0.79{\pm}0.06$ and $0.10{\pm}0.07$, respectively. These findings suggest that the surface EMG of rectus abdominis muscle might be used indirectly for more convenient measurement of abdominal pressure on ambulatory urodynamic study.