• Title/Summary/Keyword: 비정상 열해석

Search Result 158, Processing Time 0.023 seconds

A Study on the Analysis of Surface Heat Flux Using the Transient Heat Flux Method (비정상열유속 기법을 이용한 표면 열유속 해석에 관한 연구)

  • Yi, Jong-Ju
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.13 no.3
    • /
    • pp.503-510
    • /
    • 2010
  • The quick variation of the canister wall temperature causes the modification of the shape of canister wall. This paper is the possibility of adoption and the error analysis about the transient heat flux method. The commercial code(Fluent Ver6.2.16) was employed for the calculation of surface temperature in the case of steady and unsteady heat flux condition. Based the surface temperature variation and surface material property, transient heat flux method can calculate the surface heat flux. In the case of steady heat flux condition, the error is about 2%, and in the case of unsteady heat flux condition, the error is about 3.6%. With the unsteady heat flux condition, the time which reach the maximum surface heat flux is almost same between the numerical analysis and transient heat flux method.

Stator Current Processing Based Technique for Induction Motors Bearing Faults Diagnosis (유도전동기 베어링고장진단을 위한 고정자전류프로세싱 기술개발)

  • Hong, Won-Pyo;Yoon, Sup-Chung;Kim, Dong-Hwa
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.311-318
    • /
    • 2005
  • 이 논문은 다른 종류의 유도전동기 구름베어링 손상을 유도전동기 고정자 전류신호해석을 통하여 검출하고 실시간으로 손상을 진단하는 알고리즘을 개발하였다. 유도전동기 구름베어링의 손상을 검출하기 위하여 정상적인 베어링을 갖는 유도전동기, 축정열에 불량을 가지고 있는 전동기와 베어링 외륜에 구멍을 가지고 있는 2가지 종류의 비정상 베어링을 갖는 유도전동기 3set를 실험시스템을 구축하였다. 또한 유도전동기의 구름베어링시스템의 비정상적인 상태에서 고정자전류을 검출하기 위하여 TMS320F2407 DSP 칩을 이용하여 데이터 획득보드를 개발하였다. 이 고정자전류신호를 해석을 통하여 베어링 손상을 검출하기 위한 방법으로 FPT, 웨이브렛 분석 및 내적에 의한 평균신호패던에 의한 분석결과를 제시하였다. 특히 내적에 의한 신호분석을 통하여 베어링 손상 여부를 실시간으로 진단할 수 있는 새로운 알고리즘과 분석방법을 제시하였다.

  • PDF

표준원전 모의 열수력 종합실험장치의 개념설계 및 저온관 소형냉각재상실사고 예비해석

  • 배규환;문상기;박춘경;권태순;송철화;양선규;정문기
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05a
    • /
    • pp.699-706
    • /
    • 1998
  • 한국원자력연구소에서는 원자력중장기연구의 일환으로 한국형 표준원전을 모의하는 종합열수력실증실험을 계획하고 있으며, 현재 실험장치에 대한 척도해석(Scaling Analysis), 예비해석(Scoping Analysis) 및 개념설계를 수행하고 있다. 본 논문에서는 영광 3/4호기를 대상으로 척도해석을 통하여 실험장치를 개념설계하고, 저온관 6인치 소형냉각재 상실사고에 대하여 예비해석을 수행한 결과를 보여준다. 개념설계된 실험장치는 높이비가 참조원자로와 동일하고, 체적비가 1/200이다. 실험장치의 개념설계는 이상유동에 대한 3단계 척도법을 적용하였으며, 개념설계의 타당성을 입증하기 위해 RELAP5/MOD3.1 코드를 사용하여 정상상태 및 저온관 6인치 소형냉각재 상실사고시 계통의 거동을 예비 계산하였다. 실험장치에 대한 예비해석결과 사고 거동이 참조원자로와 잘 일치하는 것으로 나타났다. 또한 수평관 및 주냉각재펌프의 척도기준이 사고의 진행과정에 영향을 미치는 중요한 인자로 밝혀졌다

  • PDF

URANS Computations for Flow Mixing of Heated Dual Jets (URANS를 이용한 가열된 이중제트의 유동혼합 특성에 대한 수치해석)

  • Park, Tae Seon
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.23 no.3
    • /
    • pp.18-27
    • /
    • 2019
  • The flow mixing characteristics for the heated dual jets were numerically studied by using URANS (unsteady Reynolds-averaged Navier-Stokes). The increased turbulent diffusion was obtained for the compressible flow, and the thermal diffusion of incompressible flow increased more than that of compressible flow. From the results of FFT and phase portraits, periodic and quasi-periodic states were observed as the jet spacing increased. It was observed that linear variations of merging points and combined points were different because unsteady flow determined the flow mixing characteristics for a large jet spacing.

Measurement and Analysis of Instantaneous Surface Temperature and Unsteady Heat Flux at Combustion Chamber of DOHC Gasoline Engine ; Cylinder Linder (DOHC 가솔린기관의 연소실 벽표면순간온도 및 비정상 열유속 측정 및 해석(제3보 : 실린더 라이너에 관한 연구))

  • 위신환;이종태
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.8 no.3
    • /
    • pp.1-11
    • /
    • 2000
  • Instantaneous temperature probes were manufactured by pressing method. By using these probes, the instantaneous surface temperature and unsteady heat flux in the cylinder liner of DOHC engine were measured. The main results are as follows; ⅰ) the instantaneous surface temperature of cylinder liner are affected by the contact of piston ring as well as burning gas. ⅱ) the wall temperature of the siamese portion is much higher than other parts. ⅲ) it was shown that the rising trend of heat flux by burning gas are nearly limited to the 1/2-stroke distance from the top of cylinder liner.

  • PDF

A Study on Unsteady Thermal Loading of Hydrogen Engine with Dual Injection (이중분사식 수소기관의 비정상 열부하 해석에 관한 연구)

  • Wei, Shin-Whan;Kim, Yun-Young;Kim, Hong-Jun;Lee, Jong-Tai
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.12 no.2
    • /
    • pp.147-155
    • /
    • 2001
  • To measure of thermal loading in the combustion chamber of hydrogen engine with dual injection, instantaneous wall-surface temperature and unsteady heat flux of the cylinder head are measured and analyzed. The maximum wall surface temperature is shown in direct injection region which has large heat supplied. Partial and spatial temperatures have slight deviation in transient region of injection, though injection method change suddenly. All of thermal characteristics such as instantaneous temperature, temperature swing and heat flux of hydrogen engine with dual injection are remarkably higher than those of gasoline engine. It means necessity of additional countermeasure of thermal loading.

  • PDF

Development of Westinghouse 950 MWe-type NPA (WH형 950MWe 원전 운전최적분석기 개발)

  • 홍진혁
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2003.05a
    • /
    • pp.473-483
    • /
    • 2003
  • 본 논문은 안전해석 등에 사용되는 RETRAN-3D 등 최적해석 코드를 기반으로 하면서도 복잡한 하드웨어 없이 간편한 GUI (Graphic User Interface)를 이용하여 광범위한 발전소 과도상태를 해석하기 위한 다양한 기능을 통해 시뮬레이션 조작을 쉽게 할 수 있는 웨스팅하우스형 950MW급 최적 원전운전분석기 (Nuclear Plant Analyzer)를 다루고자 한다. WH형 950MW 원전 운전최적분석기는 기존의 단순한 Point Kinetics 모델이 아닌 정교한 3D 실시간 노심모델과 RETRAN 코드를 기반으로 하는 실시간 NSSS 열수력 모델 (ARTS)이 통합된 모델을 갖추고 있으며, 해당형식발전소 (WH 3 Loop PWR Plant : 고리 3,4호기, 영광1,2호기 원전)의 여러 가지 과도사고를 실시간으로 정상, 비정상, 비상운전 등으로 모의할 수 있도록 개발되었다. 모의결과 주요 과도 상태의 결과가 해석한 결과와 잘 일치하였으며, 해당형식 발전소 과도 분석이나 규제요원 훈련에 이용될 계획이다.

  • PDF

Comparison of the Effects of Straight and Twisted Heat Trace Installations Based on Three-dimensional Unsteady Heat Transfer (열선의 직선시공과 감기시공의 동파방지 효과 비교를 위한 3차원 비정상 수치해석)

  • Choi, Myoung-Young;Jeon, Byoung-Jin;Choi, Hyoung-Gwon
    • Fire Science and Engineering
    • /
    • v.30 no.1
    • /
    • pp.49-56
    • /
    • 2016
  • This paper numerically examines, straight and twisted electrical heat trace installations for their anti-freezing effects on water inside a pipe. The unsteady incompressible Navier-Stokes equations coupled with an energy equation were solved to compare the two installation methods. The heat conduction of the pipe with a heat source interacts with the natural convection of the water, and the conjugate heat transfer was considered using a commercial code (ANSYS-FLUENT) based on a SIMPLE-type algorithm. Numerical experiments, were done to investigate the isotherms and the vector fields in the water region to extract the evolutions of the minimum and maximum temperatures of the water inside the pipe. There was no substantial difference in the anti-freezing effects between the straight and twisted. Therefore, the straight installation is recommended after considering the damage and short circuit behavior of the electrical heat trace.

Safety Assessment of Burned Building using Numerical Calculation of Unsteady Heat Conduction Equation (비정상 열전도 방정식의 수치 해석을 이용한 화재 건물의 안전성 평가)

  • 태순호;이병곤
    • Fire Science and Engineering
    • /
    • v.11 no.2
    • /
    • pp.19-24
    • /
    • 1997
  • numerical simulation of unsteady heat conduction equation were carried out by finite control volume method using the gas temperature derived from fire model as a boundary value. The reduction of compressive and flexural by heating were calculated from the temperature and the given reduction rate. It is shown that this method could be well applied to assess the safety of concrete column or beam of the burned building.

  • PDF