• Title/Summary/Keyword: 비선형 초음파

Search Result 138, Processing Time 0.024 seconds

Performance and Analysis of Linear Prediction Algorithm for Robust Localization System (앰비언트 디스플레이 위치추적 시스템의 데이터 손실에 대한 선형 예측 알고리즘 적용 및 분석)

  • Kim, Joo-Youn;Yun, Gi-Hun;Kim, Keon-Wook;Kim, Dae-Hee;Park, Soo-Jun
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.45 no.4
    • /
    • pp.84-91
    • /
    • 2008
  • This paper suggests the robust localization system in the application of ambient display with multiple ultrasonic range sensors. The ambient display provides the interactive image and video to improve the quality of life, especially for low mobility elders. Due to the limitation of indoor localization, this paper employs linear prediction algorithm to recover the missing information based on AR(Autoregressive) model by using Yule-Walker method. Numerous speculations from prediction error and computation load are considered to decide the optimal length of referred data and order. The results of these analyses demonstrate that the linear prediction algorithm with the 16th order and 50 reference data can improve reliability of the system in average 74.39% up to 97.97% to meet the performance of interactive system.

A Study for Automotive Lamp Manufacturing System Control Composing Ultra melting Process (초음파 접합 공정을 합성한 자동차용 램프 생산시스템 제어에 관한 연구)

  • Lee, Il-Kwon;Kook, Chang-Ho;Kim, Seung-Chul;Kim, Ki-Jin;Han, Ki-Bong
    • Journal of the Korean Institute of Gas
    • /
    • v.18 no.1
    • /
    • pp.46-51
    • /
    • 2014
  • The purpose of this paper is to study of the vehicle lamp manufacturing system composing ultrasonic waves connection process. Making lamp assembly plant, it was produced in the separate process as the injection molding, ultrasonic waves bonding, annealing in the constant temperature, lamp assembling and packing. But the improvement method producing the lamp was added with one-step process by one automation technique. As a result, welding with ultrasonic waves process, the method decreased the energy consumption and noise during ultrasonic waves welding. Therefore, this method used the mathematics modeling for checking validity, it selected the stability and suitable controller using transfer function of plant and bode chart. In this study, the $180^{\circ}$ revolution control system to turn injection part upside down was $M_{eq}\;lcos{\theta}(t)$ because of gravity influence. It effected to unstable condition a system. For solving this problem, it aimed the linearization and stabilization of system by elimination $M_{eq}\;lcos{\theta}(t)$ as applying Free-forward control technique.

Characteristics of Lecithin-adsorbed Magnetic Nanoparticle and Biocompatibility of Its Fluid (Lecithin이 흡착된 나노 자성입자의 특성과 그 자성유체의 생체 친화성)

  • Park, Sang-Im;Kim, Chong-Oh;Kim, Jong-Hee;Kim, Seong-Min;Kim, Keun-Ho
    • Journal of the Korean Magnetics Society
    • /
    • v.16 no.6
    • /
    • pp.293-299
    • /
    • 2006
  • Magnetic nanoparticles were prepared by thermal decomposition and adsorbed with lecithin by applying ultrasonic. The size and saturation magnetization of magnetic nanoparticles were observed with different lecithin concentration, and the maximum tolerated dose (HTD) and toxicity of magnetic fluid was investigated through a biological test. The thickness of lecithin-adsorption layer increased non-linearly with increasing amounts of added lecithin, and the desirable adsorption amount was observed in the lecithin concentration of 20%(w/v). The dispersibility and magnetic properties of lecithin-adsorbed magnetic nanoparticles were most excellent when the ultrasonic exposure time was 1.5h. Also, the maximum tolerated concentration with best cell viability was $32{\mu}g/ml$ in vitro test, and lecithin-adsorbed magnetic fluids improved the biocompatibility by 1.2 times compared with bare magnetite fluids in vivo.

Characterization of Low-cycle Fatigue of Copper and Isothermal Aging of 2.25Cr Ferritic Steel by Ultrasonic Nonlinearity Parameter (초음파 비선형파라미터를 이용한 무산소동 저주기피로와 2.25Cr 페라이트강의 등온열화 평가)

  • Kim, Chungseok
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.35 no.5
    • /
    • pp.239-245
    • /
    • 2022
  • The purpose of this study is to evaluate the degree of microstructural change of materials using ultrasonic nonlinear parameters. For microstructure change, isothermal heat-treated ferritic 2.25Cr steel and low-cycle fatigue-damage copper alloy were prepared. The variation in ultrasonic nonlinearity was analyzed and evaluated through changes in hardness, ductile-brittle transition temperature, electron microscopy, and X-ray diffraction tests. Ultrasonic nonlinearity of 2.25Cr steel increased rapidly during the first 1,000 hours of deterioration and then gradually increased thereafter. The variation in non-linear parameters was shown to be coarsening of carbides and an increase in the volume fraction of stable M6C carbides during heat treatment. Due to the low-cycle fatigue deformation of oxygen-free copper, the dislocation that causes lattice deformation developed in the material, distorting the propagating ultrasonic waves, and causing an increase in the ultrasonic nonlinear parameters.

Estimation of Structural Properties from the Measurements of Phase Velocity and Attenuation Coefficient in Trabecular Bone (해면질골에서 위상속도 및 감쇠계수 측정에 의한 구조적 특성 평가)

  • Lee, Kang-Il
    • The Journal of the Acoustical Society of Korea
    • /
    • v.28 no.7
    • /
    • pp.661-667
    • /
    • 2009
  • Trabecular-bone-mimicking phantoms consisting of parallel-nylon-wire arrays were used to investigate correlations of phase velocity and attenuation coefficient with structural properties in trabecular bone. Trabecular separation (Tb.Sp) of the 7 trabecular-bone-mimicking phantoms ranged from 300 to $900\;{\mu}m$ and volume fraction (VF) from 1.6% to 8.7%. Phase velocity and attenuation coefficient of the phantoms were measured by using a through-transmission method in water, with a matched pair of broadband unfocused transducers with a diameter of 12.7 mm and a center frequency of 1 MHz. Phase velocity and attenuation coefficient at 1 MHz decreased almost linearly with increasing Tb. Sp and increased almost linearly with increasing VF. The simple and multiple linear regression models with phase velocity and attenuation coefficient as independent vanables and Tb.Sp and VF as dependent variables demonstrated that the coefficients of determination for the prediction of VF were higher than those for the prediction of Tb.Sp. The results obtained in the trabecular-bone-mimicking phantoms consisting of parallel-nylon-wire arrays were consistent with those in human trabecular bone suggesting that the structural properties can be estimated from the measurements of phase velocity and attenuation coefficient in trabecular bone.

Temperature Rise due to Nonlinear Propagation of Ultrasound using Weak Shock Theory (Weak Shock Theory를 이용한 초음파의 비선형 전파에 의한 온도 상승)

  • Choi, M.J.;Sung, K.M.;Lee, S.E.;Chung, B.H.;Lee, M.S.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.74-75
    • /
    • 1998
  • The present study employs weak shock theory and bio-heat transfer function to predict the temperature rise due to nonlinear propagation of high amplitude ultrasound. The theory shows that, for the focused ultrasound which is assumed to have an gaussian beam profile and has the focal intensity of $1000W/cm^2$, the temperature rise of liver tissue exposed for 1 second to the energy lost during nonlinear propagation goes up to about $30^{\circ}C$. This indicate that it is necessary to consider the nonlinear propagation induced heating enhancement when setting exposure condition of high intensity focused ultrasound used for cancer thermotherapy.

  • PDF

Evaluation of Thermal Degradation of 2.25Cr-1Mo Steel Using Ultrasonic Nonlinear Effect and X-ray Diffraction Method (초음파 비선형 음향 효과 및 X-선 회절법을 이용한 2.25Cr-1Mo 강의 열화 손상 평가)

  • Kim, Duk-Hee;Park, Un-Su;Park, Ik-Keun;Byeon, Jai-Won;Kwun, Sook-In
    • Journal of the Korean Society of Safety
    • /
    • v.17 no.4
    • /
    • pp.71-79
    • /
    • 2002
  • It was attempted to evaluate the degree of degradation of thermally aged 2.25-1Mo steek by ultrasonic monlinear parameter(UNP) measurement and X-ray diffraction analysis of extracted carbide. Artificial aging was performed to simulate the microstructural degradation in 2.25Cr-1Mo steel arising from long time exposure at $540{\circ}C$. Microstructural analysis (number of carbides per unit area) and measurements of mechanical properties(Vickers hardness, DBTT) and degradation evaluation parameters(UNP and intensity ration of X-ray diffraction peak of electrolytically extracted carbide) were performed. Both of UNP and intensity ratio of X-ray diffraction peak for M6C carbide to that of M23C6 carbide(IR) increased abruptly in the initial 1000 hour of aging and then changed little. UNP and IR were proposed as potential parameters to evaluate the degree of aging degradation of 2.25Cr-1Mo steel.

Reconstruction and Deconvolution of X-Ray Backscatter Data Using Adaptive Filter (적응필터를 이용한 적층 복합재료에서의 역산란 X-Ray 신호처리 및 복원)

  • Kim, Noh-Yu
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.20 no.6
    • /
    • pp.545-554
    • /
    • 2000
  • Compton X-ray backscatter technique has been used to quantitatively assess the impact damage in quasi-isotropic laminated composites and to obtain a cross-sectional profile of impact-damaged laminated composites from the density variation of the cross section. An adaptive filter is applied to the Compton backscattering data for the reconstruction and noise reduction from many sources including quantum noise, especially when the SNR(signal-to-noise ratio) of the image is relatively low. A nonlinear reconstruction model is also proposed to overcome distortion of the Compton backscatter image due to attenuation effects, beam hardening, and irregular distributions of the fibers and the matrix in composites. Delaminations masked or distorted by the first few delaminations near the front surface are detected and characterized both in width and location, by application of an error minimization algorithm.

  • PDF

A study on effective disinfection methods of medical ultrasound probe resident floras (의료용 초음파 프로브 상제균의 효과적인 소독법에 관한 연구)

  • Yoon, Joon;Kim, Hyeon-ju
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.1
    • /
    • pp.346-354
    • /
    • 2018
  • In the probe of a medical ultrasound device, three parts were selected randomly by the examiner and the bacteria in the probe were detected by the blood examiners. In addition, the degree of death of the pathogenic bacteria after each disinfection of the detected pathogens, disinfecting ethanol, and disinfecting tissue of the detected pathogens were analyzed quantitatively. The following was detected: S Aureus (32.3 %), Bacillus spp. (26.5 %), Micrococcus spp. (21.5 %), and CNS (20 %). With the conventional probe, S. aureus (26.2 %), a playback curve (24.2 %), and a micron (19.5 %), Micrococcus spp. (15.5 %), and CNS (14.6 %) were observed. In the fan probe, S. aureus (24.7 %), Enterococcus (24.7 %), Enterococcus (17.7 %), and CNS (13.8 %) were detected. The disinfection of the three pathogens detected revealed sterilization of most of the pathogens, and most cases contained at least 91.3 % of the total sterilizing effect (P>0.05). In addition, for the disinfection of Propolis extract and disinfecting tissue, the disinfection effect was lower than that of disinfecting ethanol, but the difference was not statistically significant (P>0.05). The results revealed bacteria on most of the ultrasound probes. Antiseptic disinfection of surgical instruments using an extract of propolis works with results similar to those of ethanol. A blood test along with disinfection can help prevent infection if an ultrasound probe is applied to food.

A Spleen Size Measured by Ultrasound in 20's Normal Adults (초음파검사에 의한 20대 정상 성인의 비장 크기)

  • Kim, Yon-Min
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.3
    • /
    • pp.337-343
    • /
    • 2020
  • An enlarged spleen can be caused by infections, cirrhosis and other liver diseases, blood diseases characterized by abnormal blood cells, problems with the lymph system, immune diseases, or other conditions. Therefore, knowing the normal size of the spleen is helpful for the diagnosis of spleen and may be useful for follow-up. Ultrasonographic examination may be considered normal size if the maximum length is less than 12 cm and less than 5 cm in thickness, but may vary depending on sex and race. We aimed to present the normal range of spleen size by measuring the spleen size by ultrasonography in 20's normal adult Korean. The length of the male spleen was 10.95±1.07 cm and the width was 4.48±0.61 cm. The female length was 9.20±1.30 cm and the width was 3.55±0.44 cm. There was a significant difference (p<0.001). The spleen length increased with increasing height (r=.57) and there was a significant positive linear relationship with increasing spleen length as body weight increased(r=.63). In normal adults, 5 men and 2 women had a spleen length of more than 12 cm and 2 men with a size exceeding 13 cm.