• Title/Summary/Keyword: 비선형응답

Search Result 558, Processing Time 0.019 seconds

Seismic Response Analysis of Wood Structure Using Nonlinear Time History Method (비선형 시간 이력법에 의한 목조 가옥의 지진응답해석)

  • 김재관
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1998.04a
    • /
    • pp.212-219
    • /
    • 1998
  • Dynamic analyses are performed for the wood structure modeled as a SDOF hysteretic system. The hysteresis model presented is a modified version of Takeda model. The comparison between the results of numerical simulation and the experimental results show good agreements in overall tendencies. The response of wood structure subjected to artificially generated earthquakes considering site effects is studied. It appears that the response is very strongly influenced by the intensity and the frequency contents of the ground motion.

  • PDF

Global Bifurcation for the Responses in the Traveling Wave Form of a Circular Plate (원판의 진행파응답을 위한 대역분기해석)

  • 여명환;이원경
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.287-296
    • /
    • 2003
  • We investigate global bifurcation in the motion of an harmonically excited circular plate with one-to-one internal resonance. A perturbation method developed by Kovacic and Wiggins is used. Silnikov type homoclinic orbit has been pursued but it has turned out not to exist.

  • PDF

Validity of the Multiple Scale Solution for a Resonance Response of a Bar with a Nonlinear Boundary Condition (비선형 경계조건을 가진 봉의 공진응답을 위한 다중시간해의 타당성)

  • 이원경;여명환;배상수
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1996.10a
    • /
    • pp.275-281
    • /
    • 1996
  • In order to examine the validity of an asymptotic solution obtained from the method of multiple scales, we investigate a third-order subharmonic resonance response of a bar constrained by a nonlinear spring to a harmonic excitation. The motion of the bar is governed by a linear partial differential equation with a nonlinear boundary condition. The nonlinear boundary value problem is solved by using the finite difference method. The numerical solution is compared with the asymptotic solution.

  • PDF

Efficient Dynamic Response Analysis of Structures Supported By Nonlinear Resilient Mounts Using Structural Synthesis Method (구조합성법을 이용한 비선형 탄성마운트 지지 구조물의 효율적인 동적 응답 해석)

  • Chung, J.H.;Kim, B.H.;Yang, Y.J.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.287-290
    • /
    • 2000
  • An efficient dynamic response analysis method of structures supported by nonlinear resilient mounts when subjected to the transient base excitations is presented by using the structural synthesis method in time domain. Through a numerical example, the validity of the presented method is verified by comparison of the results with those of the 'traditional' analysis method.

  • PDF

Current Mode PWM Control for the Buck Converter Using One Cycle Response (한주기 응답 기법을 적용한 벅 컨버터의 전류 모드 PWM 제어)

  • 전칠환;김철웅
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.4 no.5
    • /
    • pp.1117-1125
    • /
    • 2000
  • A current mode PWM method applied one cycle response to averaging circuit model Buck converters is presented. The controller nonlinear PWM implement is based on the error between the switched variable and the response reference to zero each cycle. As the result, the system transfer function is derived as a function of the desired close loop poles, simplifying the design procedure and bringing forward all the important characteristics of the close loop system. The proposed controller has significant advantages over conventional current mode control methods in noise susceptibility, dynamic response and without inductor current sensing, Finally, the simulation and experiment results confirm the proposed PWM control techniques.

  • PDF

Design of LQR Controller for Thermal Management System of 5kW Solid Oxide Fuel Cell (5kW급 고체 산화물 연료전지 열관리 계통 LQR 상태 궤환 제어기 설계)

  • Jeong, Jin Hee;Han, Jae Young;Sung, Yong Wook;Yu, Sang Seok
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.6
    • /
    • pp.505-511
    • /
    • 2015
  • Solid oxide fuel cell operate at high temperature ($800{\sim}1000^{\circ}C$). High temperature have an advantage of system efficiency, but a weak durability. In this study, linear state space controller is designed to handle the temperature of solid oxide fuel cell system for proper thermal management. System model is developed under simulink environment with Thermolib$^{(R)}$. Since the thermally optimal system integration improves efficiency, very complicated thermal integration approach is selected for system integration. It shows that temperature response of fuel cell stack and catalytic burner are operated at severe non-linearity. To control non-linear temperature response of SOFC system, gain scheduled linear quadratic regulator is designed. Results shows that the temperature response of stack and catalytic burner follows the command over whole ranges of operations.

Earthquake Resistant Performance of a High-rise Shear Wall Apartment Based on Nonlinear Time History Response Analysis (동적 탄소성 지진응답해석에 의한 고층 벽식 아파트의 내진성능 검토)

  • 박성수
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.3 no.1
    • /
    • pp.1-8
    • /
    • 1999
  • Dynamic elastoplastic LPM (lumped parameter mass) analyses are carried out in order to investigate the seismic resistant performance of a typical high-rise shear wall apartment subjected to several earthquakes. Three-dimensional nonlinear pushover analysis is adopted to estimate initial elastic stiffness, yielding strength and post-yielding stiffness of each story for the time history analysis of LPM shear model. For the hysteresis of each story, Clough and bilinear models are used with the input of four recorded earthquake ground motions of EI Centro 1940 NS, Taft 1952 EW, Hachinohe 1968 NS and Kobe 1995 NS, of which the amplitudes are scaled down to have the same maximum ground velocity of 12 kine. The result shows that yieldings take place in most storys of the building, i.e. the earthquake resistant capacity of this high-rise shear wall apartment is not sufficient at the event of earthquake M=5~6.

  • PDF

Cyclic Hardening and Degradation Effects on Site Response during an Earthquake (지진시 지반의 반복경화/연화 현상에 의한 부지응답 특성 영향 연구)

  • Lee, Jin-Sun
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.12 no.6
    • /
    • pp.65-71
    • /
    • 2008
  • A one-dimensional site response analysis program (KODSAP) was developed using cyclic soil behavior model by using the modified parallel IWAN model. The model is able to predict the cyclic hardening and degradation of soil through the adjustment of the internal slip stresses of its elements beyond the cyclic threshold, and satisfies Bauschinger's effect and the Masing rule in terms of its own behavior characteristics. The program (KODSAP) used the direct integration method in the time domain. The elasticity of the base rock was considered as a viscous damper boundary condition. The effects of cyclic hardening or degradation of soil on site response analysis were evaluated through parametric studies. Three types of analyses were performed to compare the effect of analysis and cyclic parameter on site response. The first type was equivalent linear analysis, the second was nonlinear analysis, and a third was nonlinear analysis using the cyclic hardening or degradation model.

The optimum damping retrofit for cabinet structures of NPP by μ-GA (μ-GA를 이용한 원전 캐비닛구조물의 최적감쇠보강)

  • Lee, Gye-Hee;Ha, Dong-Ho
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.9 no.1 s.41
    • /
    • pp.1-7
    • /
    • 2005
  • The optimal seismic retrofitting of NPP(Nuclear Power Plant) cabinet structures that contain seismic category 1 relays was studied in this paper. During earthquake event, the failure modes of relays are not appeared in form of structural failure, but are appeared in form of contact chatter of relay. Therefore, the retrofitting of cabinet has to be aimed at the reducing of the structural response, such as acceleration. In this study, the optimal characteristic values of dampers were searched by ${\mu}$-GA (micro-Genetic Algorithm) scheme for several installation patterns. To keep accuracy and efficiency of analysis, the structural models of cabinet were considered as a frame structure. The responses of structure were obtained inform of acceleration response spectra derived from the results of nonlinear time history analysis including damping nonlinearity. The objective function of the optimum procedure was constructed based on the maximum ratio of maximum spectral value and target GERS (General Equipment Ruggedness Spectra). The results show the good improvements of fitness for adequate retrofitting pattern. Especially, the improvements of fitness were remarkable when the values of damping exponents are low.

Nonlinear Static Analysis for Seismic Performance Evaluation of Multi-Span Bridges Considering Effect of Equivalent SDOF Methods (등가단자유도 방법의 영향을 고려한 다경간 교량의 내진성능 평가를 위한 비탄성 정적해석)

  • Song, Jong-Keol;Nam, Wang-Hyun;Chung, Yeong-Hwa
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.3A
    • /
    • pp.473-484
    • /
    • 2006
  • The capacity spectrum method (CSM) can be used to simply estimate the maximum displacement response of the nonlinear structures. To evaluate seismic performance of multi-span bridges using the CSM, the representative response for structural system should be derived from the multi-degree-of-freedom (MDOF) responses by using the equivalent single-degree-of-freedom (ESDOF) method. The ESDOF method is used to calculate the capacity curve of the structural system from the pushover curves of all piers or structural members estimated by the pushover analysis. In order to evaluate an accuracy of ESDOF methods used in the CSM, the maximum displacements estimated by the CSM incorporating the several ESDOF methods are compared to those by the inelastic time-history analysis for several artificial earthquakes corresponding to the design spectrum.