• Title/Summary/Keyword: 비상발전기

Search Result 142, Processing Time 0.033 seconds

The Design of a I/O Interface Circuits for the Signal Driver of the Engine Control Relays and the Output Signal Monitoring of Diesel Generator (디젤 발전기 출력 신호의 모니터링 및 엔진제어 릴레이 구동을 위한 입출력 인터페이스 회로 설계)

  • Joo, Jae-hun;Kim, Jin-ae;Choi, Jung-Keyng
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.05a
    • /
    • pp.547-550
    • /
    • 2009
  • This paper presents a digital based input/output interface circuit for controlling and monitoring the Diesel Engine Generator for Emergency. In order to monitor and control of the Emergency Diesel Engine Generator, controlling and monitoring circuits need 5 analog input channels, 2 pick-up coil measuring circuits, 10 digital input channels containing Broken Wire Detect function, and 7 relay control signal output channels. This system performs signal processing of input signal taking advantage of simple filter circuit, photo-coupler and comparator circuit at analog input parts, and output signals for main relay is designed acting by double control, so it prevents malfunction completely. And it improves accuracy of speed input signal by applying digital circuit that processes pick-up coil signal.

  • PDF

The commercialization of ESS PCS replacing Emergency Generator (비상발전용 ESS(Energy Storage System) 상용화 개발)

  • Park, Minjun;Seo, Jungwon;Hwang, Kwangkyu;Park, Juhyun;Jang, Jeahoon;Kim, Heejung
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.461-462
    • /
    • 2016
  • 본 논문은 100kW 급 비상발전용 ESS 상용화 개발을 제안한다. 비상발전기란 전력계통이 정지되었을 때 발전장치를 구동시켜 전력을 생산하는 자가발전설비를 말한다. 제안하는 시스템은 2Level 전압형 100kW 급 비상발전용 ESS 로써 정상 시 계통 전원과 동기 운전을 수행하는 계통 연계형 전력변환장치이다. 수배전 수용가에 설치되어 운영이 가능하며 일반적인 ESS PCS 기능인 주파수 조정 (Frequency Regulation), 출력 안정화, 첨두부하 저감 (Peak Shaving), 부하평준화 (Load Leveling), 수요반응 (Demand Response)에 추가하여, 자가발전 (Black Start), 무효전력제어 등의 기능을 적용 하였다. 제안된 100kW 급 비상발전기용 ESS PCS 는 시뮬레이션 및 프로토 타입을 이용하여 성능을 검증하였다.

  • PDF

The Operation Method of Emergency Power Supply System in Bipolar LVDC Using Emergency Generator and ESS (비상발전기와 ESS를 이용한 양극성 저압 직류배전에서의 비상 전력 공급 시스템 운영 방법)

  • Kang, Kyung-Min;Kang, Jin-Wook;Song, Jun-Ho;Lee, Hoon;Kwon, Yong-Hoon;Won, Chung-Yuen
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.180-182
    • /
    • 2018
  • 직류배전 시스템은 신재생에너지 및 ESS(Energy Storage System)와의 결합으로 높은 에너지 이용효율을 가질 수 있다. 이러한 직류배전 시스템은 기존 교류계통을 통해 구성되며, 다양한 디지털 부하가 연계되므로 교류계통 및 메인 PCS(Power Conversion System)에 문제가 발생했을 때를 대비하여 비상 전력 공급 시스템이 필수적으로 고려되어야 한다. 최근 직류배전에서 비상 전력 공급 시스템으로 큰 관심을 받고 있는 ESS는 초기 설치비용, 용량, 수명 등의 문제로 인해 단일로 비상 전력 공급 시스템을 구성하기에 어려움이 있다. 때문에 기존에 이미 많이 설치되어 있는 비상발전기의 적용이 검토되어야 한다. 본 논문에서는 비상발전기와 ESS를 활용하여 양극성 저압직류배전에서 정전과 같은 사고 상황 발생 시 직류배전망의 전압을 빠르게 안정시킬 수 있는 시스템과 그 운영기법을 제안하였고, PSIM 시뮬레이션을 통하여 타당성을 검증하였다.

  • PDF

Selection and Analysis of Operating Parameters for Condition Monitoring of Emergency Diesel Generator at Nuclear Power Plant (원자력발전소 비상디젤발전기 상태감시를 위한 운전인자 선정에 관한 연구)

  • Park, J.H.;Choi, K.H.;Lee, S.G.;Park, J.E.
    • Journal of Power System Engineering
    • /
    • v.11 no.3
    • /
    • pp.3-8
    • /
    • 2007
  • The emergency AC power supply system of the nuclear power plant is designed to supply the power to the nuclear reactor at the emergency operating condition. The safety function of the diesel generator at the nuclear power plant is to supply AC electric power to the plant safety system whenever the preferred AC power supply is unavailable. The reliable operation of onsite emergency diesel generator should be ensured by a conditioning monitoring system designed to maintain and monitor and forecast the reliability level of diesel generator. To do this kind of diesel generator condition monitoring we reviewed several operating factors and history of the wolsong unit 3 diesel generator and selected the proper conditioning monitoring operating factors.

  • PDF

Application Study of Condition Monitoring Technology for Emergency Diesel Generator at Nuclear Power Plant (원자력발전소 비상디젤발전기 상태감시 기술 적용 연구)

  • Choi, K.H.;Park, J.H.;Park, J.E.;Lee, S.G.
    • Journal of Power System Engineering
    • /
    • v.13 no.1
    • /
    • pp.53-58
    • /
    • 2009
  • The emergency diesel generator(EDG) of the nuclear power plant is designed to supply the power to the nuclear reactor on Station Black Out(SBO) condition. The operation reliability of onsite emergency diesel generator should be ensured by a conditioning monitoring system designed to monitor and analysis the condition of diesel generator. For this purpose, we have developing the technologies of condition monitoring for the wolsong unit 3&4 standby diesel generator including diesel engine performance. In this paper, technologies of condition monitoring for the wolsong standby diesel generator are described about three step. First is for selection of operating parameter for monitoring. Second is for technologies of online condition monitoring, Third is for monitoring of engine performance.

  • PDF

A Case Study on Noise Effect Assessment and Countermeasure by Emergency Generators installed in an Exterior and interior Architecture (건축물 내외부에 설치된 비상용 발전기 소음영향 평가 및 대책방안 사례연구)

  • Yun, Dae-Jin;Choi, Jae-Sung;Kim, Chang-Yeol;Hong, Chang-Wan;Kim, Han-Jun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.88-93
    • /
    • 2012
  • Recently data centers are being established or expanded according to IT industry development. A data center must be to install emergency generator. In case of the data center located the densely populated urban area, the operating noise of an emergency generator can be the cause of complains. In this case, in order to establish an effective and economical measure and quantitative and thorough review is needed by noise & vibration specialists. To achieve this, in this study, it is suggested noise reduction measure using noise measurement data and 3D noise analysis method.

  • PDF

원전 비상디젤발전기 엔진 상태진단용 초음파 및 진동센서 설치방법에 관한 연구

  • Lee, Sang-Guk;Choe, Gwang-Hui;Choe, Yu-Seong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.231-231
    • /
    • 2012
  • 엔진의 상태진단을 위하여 사용되는 진동 및 초음파 신호는 진동 가속도계와 초음파변환기를 대상 엔진의 취약 부위에 부착하여 측정한다. 이들 센서는 연소와 관련된 고주파진동을 측정하는 능력이 있어서 사용되고 있다. 진동가속도계와 초음파변환기의 선정 및 설치는 진동해석에서 가장 중요한 결정 요소이다. 가속도계의 설치도 주파수응답에 영향을 준다. 초음파변환기는 전자기계적 변환기로서, 진동면에서 발생하여 공기 중으로 전파되는 음파를 감지한다. 초음파변환기는 사용할 수 있는 주파수대역이 아주 협소한 대신 가속도계보다 명확한 신호를 산출한다. 초음파변환기는 사용할 수 있는 아주 협소한 주파수역을 갖는 비용으로 가속도계보다 명확한 신호를 얻을 수 있다. 따라서 본 논문에서는 원전 비상디젤발전기 엔진 상태진단을 위한 초음파 및 진동센서의 설치방법에 따른 가속도계 및 초음파 센서의 응답 특성을 분석하고 주파수응답에 대한 영향에 따라 여러 가지 설치방법의 검토를 통하여 최적방법론을 도출한 결과를 소개하고자 한다.

  • PDF