• Title/Summary/Keyword: 비교과 만족

Search Result 850, Processing Time 0.028 seconds

Optimization of Microwave Extraction Conditions for Antioxidant Phenolic Compounds from Ligustrum lucidum Aiton Using Response Surface Methodology (반응표면분석법을 이용한 여정자의 페놀계 항산화 성분에 대한 마이크로웨이브 추출조건 최적화)

  • Yun, Sat-Byul;Lee, Yuri;Lee, Nam Keun;Jeong, Eung-Jeong;Jeong, Yong-Seob
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.43 no.4
    • /
    • pp.570-576
    • /
    • 2014
  • Response surface methodology (RSM) was applied to optimize the microwave-assisted extraction (MAE) conditions for electron-donating ability, total phenol content, and total flavonoid content of Ligustrum lucidum Aiton. Ligustrum lucidum Aiton from different regions was tested, and Ligustrum lucidum Aiton from Haenam was chosen due to its higher total phenolic content, total flavonoid content, DPPH radical scavenging activity and ABTS radical scavenging activity compared to the other samples. Central composite design was used to optimize extraction of Ligustrum lucidum Aiton from Haenam as well as determine the effects of extraction temperature ($X_1$) and extraction time ($X_2$) on dependent variables ($Y_n$). Determination coefficients ($R^2$) of the regression equations for dependent variables ranged from 0.8858 to 0.9517. The optimum points were $131.68^{\circ}C$ for extraction temperature and 5.49 min for extraction time. Predicted values of the optimized conditions were acceptable when compared to experimental values.

Correlation of Effective Dose and BMI in Radioiodine($^{131}I$) Therapy (방사성옥소($^{131}I$) 치료 시 유효선량과 체질량지수의 상관관계)

  • Shin, Gyoo-Seul;Kim, Gun-Jae;Dong, Kyung-Rae;Kim, Hyun-Soo
    • Journal of radiological science and technology
    • /
    • v.31 no.1
    • /
    • pp.11-16
    • /
    • 2008
  • Purpose : The aim of this study was to predict radiation dose at 1 meter with BMI(body mass index) in thyroid cancer patients treated with radio-iodine and provide the efficient guideline in the management of patients. Methods : 140 patients from thyroidectomy for thyroid cancer were enrolled. All subjects under went 150 mCi radio-iodine therapy and performed whole body scan 1 week later. BMI(weight divided by square of height) was calculated to evaluate the amount of fatty tissue indirectly. The radiation dose at 1 meter was measured initially and on 2nd days. the relation of values with BMI were analyzed statically. As for the method of statistical analysis, using Med calc Version 9,2,2,0 Program. Results : (1) The initial effective dose was inversely correlated with the BMI. Significance level was 0.0004. (2) We obtained the following formula from the data of initial effective dose and BMI: Y = -30.91X + 350.4(${\mu}Sv/h$)(Y: initial radiation dose, x: Group). (3) After 21.55 hours, than radiation dose was less than those recommended by ICRP or NRC in 53% of the population. Conclusion : Using BMI, the initial radiation dose and 2nd days dose can be predicted in thyroid cancer patients before radio-iodine therapy. It may be used for predicting the time of discharge and control the isolation room. We were able to predict the radiation exposure after discharge using this calculated value.

  • PDF

Excellent Local Tumor Response after Fractionated Stereotactic Radiation Therapy for Locally Recurrent Nasopharynx Cancer (국소 재발 비인강암에 대한 정위적 방사선 분할 치료의 적용)

  • Lim Do Hoon;Chio Dong Rak;Kim Moon Kyung;Kim Dae Yong;Huh Seung Jae;Baek Chung-Hwan;Chu Kwang Chol;Yoon Sung Soo;Park Keunchil;Ahn Yong-Chan
    • Radiation Oncology Journal
    • /
    • v.15 no.1
    • /
    • pp.19-26
    • /
    • 1997
  • Purpose : This study is to report experience with Fractionated Stereotactic Radiation Therapy (FSRT) for locally recurrent nasopharynx cancer after curative conventional radiation therapy. Materials and Methods : Three Patients with locally recurrent and symptomatic nasopharynx cancer were given FSRT as reirradiation method between the Period of September of 1995 and August of 1996 For two Patients, application of FSRT is their third radiation therapy directed to the nasopharynx. Two patients were given low dose chemotherapy as radiation sensitizer concurrently with FSRT Authors used 3-dimensional coordinate system by individually made, relocatable Gill-Thomas-Cosman (GTC) stereotactic frame and multiple non-coplanar arc therapy dose Planning was done using Xknife-3. Total of 45 Gy/18 fractions or 50 Gy/20 fractions were given. Results : Authors observed satisfactory symptomatic improvement and remarkable objective tumor size decrease by follow-up MR images taken 1 month Post-FSRT in ali three patients, while no neurologic side effect attributable to reirradiation was noticed. Two died at 7 and 9 months with loco-regional and distant seeding outside FSRT field, while one patient is living for 4 month. Conclusion Authors experienced satisfactory therapeutic effectiveness and safety of FSRT as reirradiatlon method for locally recurrent nasopharynx cancer Development of more effective systemic chemotherapeutic regimen is desired for distant metastasis

  • PDF

Mercury Contents of Paddy Soil in Korea and its Uptake to Rice Plant (우리나라 논 토양 중 수은함량과 벼 흡수이행)

  • Park, Sang-Won;Yang, Ju-Seok;Kim, Jin-Kyoung;Park, Byung-Jun;Kim, Won-Il;Choi, Ju-Hyeon;Kwon, Oh-Kyung;Ryu, Gab-Hee
    • Journal of Food Hygiene and Safety
    • /
    • v.23 no.1
    • /
    • pp.6-14
    • /
    • 2008
  • Objective of this study was to investigate the residual levels of mercury (Hg) in soil for "Top-rice" area and its uptake into rice plant for making sure food safety as compared to "Top-rice" & common rice produced from 2005 to 2006. Hg was analyzed with the direct mercury analyzer (DMA 80, Milestone, Italy), which implements the US/EPA method 7473. The average concentration of Hg in paddy soil was 0.031 mg/kg, which was below at 1/25-1/65 fold of the threshold levels (concern level 4 mg/kg, action level 10 mg/kg) for soil contamination designated by "The Soil Environment Conservation Law" in Korea. The maximum residue level (MRLs) for Hg residue in the polished rice is not designated in Korea. Therefore, Hg contents in the polished rice of "Top-rice" brand and common rice were compared to other country's criteria. Hg contents in the polished rice of "Top-rice" brand was 0.0018 mg/kg, which was lower at 1/10-1/30 fold than the MRLs, 0.02 mg/kg of China criteria and 0.05 mg/kg of Taiwan criteria, respectively. Hg were 0.02788, 0.00896, 0.00182, 0.00189, 0.00166, 0.00452 and 0.00145 mg/kg in soil, rice straw, unhulled rice, rice hulls, brown rice, rice bran, and polished rice produced in 2006 "Top-rice" area, respectively. For the ratio of Hg as compared to Hg contents in soil, there were 0.321 of rice straw ${\gg}$ 0.162 of rice bran ${\gg}$ 0.068 of rice hulls > 0.065 of unhulled rice > 0.060 of brown rice> 0.052 of polished rice. And, the slope of Hg uptakes was steeped as following order; rice straw ${\gg}$ rice bran ${\gg}$ rice hulls > unhulled rice > brown rice > polished rice. It means that the more slope steeped was the more uptakes. For the distribution of Hg uptaken, there was 83.8% into rice straw, and 16.2% into unhulled rice, 2.8% into rice hulls, 12.4% into brown rice, 3.5% into rice bran and 9.7% into polished rice. Consequently, it was appeared that the Hg contamination in the polished rice should not be worried in Korea.

A Microcomputer-Based Data Acquisition System (Microcomputer를 이용(利用)한 Data Acquisition System에 관(關)한 연구(硏究))

  • Kim, Ki Dae;Kim, Soung Rai
    • Journal of Biosystems Engineering
    • /
    • v.7 no.2
    • /
    • pp.18-29
    • /
    • 1983
  • A low cost and versatile data acquisition system for the field and laboratory use was developed by using a single board microcomputer. Data acquisition system based on a Z80 microprocessor was built, tested and modified to obtain the present functional system. The microcomputer developed consists of 6 kB ROM, 5 kB RAM, 6-seven segment LED display, 16-Hex. key and 8 command key board. And it interfaces with an 8 channel, 12 bits A/D converter, a microprinter, EPROM programmer for 2716, and RS232C interface to transfer data between the system and HP3000 mini-computer manufactured by Hewlett Packard Co., A software package was also developed, tested, and modified for the system. This package included drivers for the AID converter, LED display, key board, microprinter, EPROM programmer, and RS232c interface. All of these programs were written in 280 assembler language and converted to machine codes using a cross assembler by HP3000 computer to the system during modifying stage by data transferring unit of this system, then the machine language wrote to the EPROM by this EPROM programmer. The results are summarized as follows: 1. Measuring program developed was able to control the measuring intervals, No. of channels used, and No. of data, where the maximum measuring speed was 58.8 microsec. 2. Calibration of the system was performed with triangle wave generated by a function generator. The results of calibration agreed well to the test results. 3. The measured data was able to be written into EPROM, then the EPROM data was compared with original data. It took only 75 sec. for the developed program to write the data of 2 kB the EPROM. 4. For the slow speed measurements, microprinter instead of EPROM programmer proved to be useful. It took about 15 min. for microprinter to write the data of 2 kB. 5. Modified data transferring unit was very effective in communicating between the system and HP3000 computer. The required time for data transferring was only 1~2 min. 6. By using DC/DC converting devices such as 78-series, 79-series. and TL497 IC, this system was modified to convert the only one input power sources to the various powers. The available power sources of the system was DC 7~25 V and 1.8 A.

  • PDF

The Accuracy Evaluation according to Dose Delivery Interruption and Restart for Volumetric Modulated Arc Therapy (용적변조회전 방사선치료에서 선량전달의 중단 및 재시작에 따른 정확성 평가)

  • Lee, Dong Hyung;Bae, Sun Myung;Kwak, Jung Won;Kang, Tae Young;Back, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.1
    • /
    • pp.77-85
    • /
    • 2013
  • Purpose: The accurate movement of gantry rotation, collimator and correct application of dose rate are very important to approach the successful performance of Volumetric Modulated Arc Therapy (VMAT), because it is tightly interlocked with a complex treatment plan. The interruption and restart of dose delivery, however, are able to occur on treatment by various factors of a treatment machine and treatment plan. If unexpected problems of a treat machine or a patient interrupt the VMAT, the movement of treatment machine for delivering the remaining dose will be restarted at the start point. In this investigation, We would like to know the effect of interruptions and restart regarding dose delivery at VMAT. Materials and Methods: Treatment plans of 10 patients who had been treated at our center were used to measure and compare the dose distribution of each VMAT after converting to a form of digital image and communications in Medicine (DICOM) with treatment planning system (Eclipse V 10.0, Varian, USA). We selected the 6 MV photon energy of Trilogy (Varian, USA) and used OmniPro I'mRT system (V 1.7b, IBA dosimetry, Germany) to analyze the data that were acquired through this measurement with two types of interruptions four times for each case. The door interlock and the beam-off were used to stop and then to restart the dose delivery of VMAT. The gamma index in OmniPro I'mRT system and T-test in Microsoft Excel 2007 were used to evaluate the result of this investigation. Results: The deviations of average gamma index in cases with door interlock, beam-off and without interruption on VMAT are 0.141, 0.128 and 0.1. The standard deviations of acquired gamma values are 0.099, 0.091, 0.071 and The maximum gamma value in each case is 0.413, 0.379, 0.286, respectively. This analysis has a 95-percent confidence level and the P-value of T-test is under 0.05. Gamma pass rate (3%, 3 mm) is acceptable in all of measurements. Conclusion: As a result, We could make sure that the interruption of this investgation are not enough to seriously affect dose delivery of VMAT by analyzing the measured data. But this investigation did not reflect all cases about interruptions and errors regarding the movement of a gantry rotation, collimator and patient So, We should continuously maintain a treatment machine and program to deliver the accurate dose when we perform the VMAT for the many kinds of cancer patients.

  • PDF

A Hierarchical Grid Alignment Algorithm for Microarray Image Analysis (마이크로어레이 이미지 분석을 위한 계층적 그리드 정렬 알고리즘)

  • Chun Bong-Kyung;Jin Hee-Jeong;Lee Pyung-Jun;Cho Hwan-Gue
    • Journal of KIISE:Software and Applications
    • /
    • v.33 no.2
    • /
    • pp.143-153
    • /
    • 2006
  • Microarray which enables us to obtain hundreds and thousands of expression of gene or genotype at once is an epoch-making technology in comparative analysis of genes. First of all, we have to measure the intensity of each gene in an microarray image from the experiment to gain the expression level of each gene. But it is difficult to analyze the microarray image in manual because it has a lot of genes. Meta-gridding method and various auto-gridding methods have been proposed for this, but thew still have some problems. For example, meta-gridding requires manual-work due to some variations in spite of experiment in same microarray, and auto-gridding nay not carried out fully or correctly when an image has a lot of noises or is lowly expressed. In this article, we propose Hierarchical Grid Alignment algorithm for new methodology combining meta-gridding method with auto-gridding method. In our methodology, we necd a meta-grid as an input, and then align it with the microarray image automatically. Experimental results show that the proposed method serves more robust and reliable gridding result than the previous methods. It is also possible for user to do more reliable batch analysis by using our algorithm.

Level of Understanding and Requirement of Education of Patients on Radiotherapy (방사선 치료 관련 정보에 대안 환자의 이해정도 및 교육요구도)

  • Kang, Soo-Man;Lee, Choul-Soo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.18 no.2
    • /
    • pp.97-103
    • /
    • 2006
  • The purpose of this study is to understand preliminary education. level of understanding and the degrees of educational requirement for cancer patients on radiotherapy and to present the preliminary data to development of effective and practical patients treatment programs. Based on the abovementioned results of this study. Relationship betweendegrees of knowledge and demand for educational requirement for patients who are undertaking radiotherapy could be varied with different factors such as educational background, ages, regions of treatment, experience of symptoms. In general, patients do not have enough information, on the other hand, have very high demand for educational requirement. Customized education patients by patients would not be possible in reality. However, if we could provide standard for patients and establish systematic sessions during treatment based on this study, more and better patients satisfaction and results of treatments could be achieved.

  • PDF

Early Clinical Outcome and Doppley Echocardiographic Data after Cardiac Valve Replacement with the ATS prosthesis (ATS 인공 판막의 조기 임상성적 및 도플러 심에코 검사 소견)

  • 박계현;박승우
    • Journal of Chest Surgery
    • /
    • v.30 no.7
    • /
    • pp.663-669
    • /
    • 1997
  • This is a report on the clinical outcome and hemodynamic profile of the ATSwcardiac valve prosthesis, which is a recently introduced pyrolytic carbon bileaflet prosthesis. We retrospectively reviewed the early outcome of 100 consecutive patients who underwent isolated cardiac valve replacement with the ATS(w prosthesis from October 1994 through June 1996 at our hospital. All patients were evaluated with Doppler echocardiography before discharge from the hospital. The mean age of the patients was 48.6 years(range: 2 to 74). A tota of 124 prosthesis were implanted; 71 mitral, 46 aortic, and 7 tricuspid. The two most frequently used sizes were 27 mm(40.8%) and 29 mm(35.2%) in the mitral position, and 23 mm(30.4%) and 21 mm(28.3%) in the aortic position. There was no early or late death. The total follow-up period was 950 patient-months with 99% follow-up rate. Serious late morbidity occurred in three patients; reoperation in two patients for late rupture of Sinus of Valsava in one and for endocarditis with prosthetic dehiscence in the other, and intracranial hemorrhage due to hypertension in one patient. There has been no thromboembolic complication or structural valval deterioration. In the mitral position, the average values of peak and mean transprosthetic pressure gradients and valve area calculated from pressure half time were 6.9$\pm$2.8 mmHg, 2.6$\pm$ 1.5 mmHg, and 2.7 $\pm$0.8 cm2 respectively. In the aortic position, the peak and mean pressure gradients'were 26.4 $\pm$ 15.9 mmHg and 14.2 $\pm$ 7.9 mmHg. For the mitra prostheses larger than 25-mm size, there was no significant difference among prosthetic sizes in terms of transprosthetic gradients, whereas there was a significant negative correlation between the prosthesis size and the transprosthetic gradients for the aortic valves. The peak and mean Pressere pradients were 52.2 $\pm$ 17.6 tmHg and 26.9$\pm$ 7.4 mmHg across the 19-mm aortic Prostheses, and 27.1 $\pm$ 11.9 mmHg and 13.3$\pm$6.6 mmHg across the 21-mm size. Above results can lead to the conclusion that the early clinical outcome of the ATS valve prosthesis is quite satisfactory, And the hemodynamic characteristics are comparable, if not better, with other bileaflet prostheses.

  • PDF

Complete Myocardial Revascularization Utilizing Parallel Secluential Anastomoses (Parallel sequential anastomosis를 이용한 관상동맥 우회수술의 성적)

  • 박계현;김관민
    • Journal of Chest Surgery
    • /
    • v.30 no.7
    • /
    • pp.647-655
    • /
    • 1997
  • We evaluated the feasibility and safety of this method by reviewing the early outcome of the patients who underwent coronary artery bypass grafting(CABG) utili ing parallel sequential anastomoses with saphenous vein grafts, comparing with the outcome of the patients revascularized with grafts having only single distal anastomosis. During the one-year period of 1995, a total of 79 patients underwent isolated CABG, among whom 39 patients with sequential vein grafts(sequential group) and 40 patients without sequential grafts(non-sequential group). There was no difference between the two groups in terms of preoperative status, except in the extent of the coronary disease; 87.2% of the sequential group and 45.0% of the non-sequential group had left main andlor triple vessel involvement. 318 distal coronary anastomoses were done; 198 for the sequential group(5.1/patient) and 120 for the non-sequential group(3.0/patient). In the sequential group, the mean durations of cardiopulmonary bypass and aortic clamp per one distal anastomosis were 33.5 and 21.1 minutes, respectively. In the non-sequential group, these were 41.8 and 22.7 minutes. There were two operative deaths, both in the non-sequential group. There was no difference in the incidence of postoperative complications including myocardial infarction. During the follow-up period(2 to 15 months), 8 patients(3 in the sequential and 5 in the nonsequential group) complained of residual or recurrent angina. Comparison of preoperative and postoperative ."'Thallium myocardial perfusion scans in 30 patients showed improved or normal perfusion reserve in 83.3% of segments bypassed with sequential grafts and 82.5% of segments bypassed with non-sequential graft(5), These results show that, utilizing parallel sequential anastomoses with saphenous vein grafts, we could achieve satisfactory short-term clinical results in patients with extensive coronary stenoses. So, we conclude that this technique is a safe, technically feasible strategy for CABG, which can achieve the aim of complete myocardial revascularization with a limited length of graft.raft.