• Title/Summary/Keyword: 붕괴성능평가

Search Result 147, Processing Time 0.024 seconds

Mobility Analysis Metric for Ad Hoc Network Using Pairwise Clustering (이진 Clustering을 이용한 Ad Hoc 망의 이동성 해석 측도)

  • Ahn, Hong-Young
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.10 no.5
    • /
    • pp.193-199
    • /
    • 2010
  • In this paper, we propose a new metric to measure the dynamic connection states of Ad Hoc network. The new metric measures the total path break up time $\sum_{i}T_i$, where $T_i$ is the time period during which maximum cluster distance exceeds the radio range. $T_i$ can be calculated from the maximum cluster distance function of time, which can be computed from the node position samples of mobility model. The proposed metric can be used as a total system metric as well as an individual connection metric.

월성 2,3,4호기 비상급수계통 성능평가에 관한 연구

  • 오광석;김창호;이중섭;김선철;오종필
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05b
    • /
    • pp.362-367
    • /
    • 1996
  • CANDU-6형 원자력발전소인 월성 2,3,4호기 비상급수계통의 성능을 평가하기 위하여 설계기능 수행과 관련된 변수로서 격납건물내 집수조(sump) 온도와 열수송계통으로 주입되는 냉각재온도를 사용한 분석을 수행하였다. 이 온도들은 NTU(Number of Transfer Unit)방법을 이용한 비상노심 냉각계통 열교환기의 열전달속도와 열전달계수의 해석을 열평형관계식과 함께 조합한 프로그램을 사용하여 계산하였다. 또한 증기발생기 급수량과 추후 수조에 공급되는 보충수에 대한 설계요건을 검토하였다. 이러한 변수와 설계요건은 비상급수계통이 발전소 정상 열제거기능 상실후 노심의 붕괴열제거에 유효한 열침원으로서의 기능을 수행함을 보여 주었다. 또 격납건물의 건전성 유지와 관련된 집수조내 최고온도가 허용치 이하로 유지되었다.

  • PDF

국내 원전의 방사성폐기물 발생량 예측과 폐기물 종류별 동굴내 배치계획

  • 최광섭;김창락;이명찬;김진웅;이지훈
    • Nuclear Engineering and Technology
    • /
    • v.27 no.2
    • /
    • pp.260-268
    • /
    • 1995
  • 국내 원자력발전소의 방사성폐기물 발생량은 초고압 압축, 농축폐액 건조, 페수지 건조 등의 폐기물감용을 위한 운영계획이 수립되고 또한 일부 원자력발전소에서는 1995년부터 운영이 시작될 예정이어서 감소가 예상되고 있다. 원자력발전소로부터 방사성폐기물의 누적량은 2035년까지 운영자의 폐기물 감용 계획을 고려한다면 141,920 드럼으로 예상할 수 있고, 이에 상응하는 방사능량은 반감기가 한달 이상인 30개 핵종에 대하여 방사성 붕괴를 무시할 때 49,390 Ci였다. 특히 원자력환경관리센터에서 수행한 개념설계에 따른 1차 건설예정의 지하 처분동굴의 적재량인 약 10만 드럼은 2014년까지 누적량으로 채울 수 있고 이때 처분장의 장기적 성능평가에 주요 고려 대상인 반감기가 5년 이상의 14개 핵종에 대한누적 방사능량은 약 13,577 Ci였다. 이 예측된 발생량과 재고량은 처분장 장기적 성능 및 안전성 평가에 중요한 기초자료가 될 것이다.

  • PDF

Anti-Seismic Performance Evaluation of Circular Pier By Interval Reinforcement (보강간격에 따른 원형 기둥부재의 내진 성능 평가)

  • Jang, Il-Young;Kim, Seong-Kyum;Park, Jun-Young;Yang, Jae-Yeol
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.165-165
    • /
    • 2011
  • 내진 설계규정이 적용되기 이전에 시공되어 사용 중인 교량의 경우 지진 발생시 교각의 파괴 또는 구조적 피해는 교량 전체 시스템의 붕괴를 초래하므로 지진하중에 대하여 피해를 최소화해야 한다. 이를 위해 내진설계규정이 적용되기 이전의 교량 또는 지진취약지역으로 분류된 곳의 교량, 사회적 중요도가 높은 교량에 대해 교각의 내진성능보강을 실시하고 있다. 2007년 말 국토해양부가 관리하고 있는 11,940개 교량 중 지진 발생시 피해가 우려되는 1,342개(일반국도 682개, 고속국도 600개) 교량에 대해 2006년부터 내진보강이 착수되었고 2009년에는 확대 추진하여 일반국도 80개교, 고속국도 100개교에 대한 보강을 실시하였다. 이와 같이 확대 추진되고 있는 정책에 반해, 내진보강 기술 및 제품이 부족하고 새로운 내진보강재 개발이 불가피해지고 있는 것이 현실이다. 소성영역에서의 횡방향 철근은 지진 시 종방향 철근의 좌굴과 콘크리트의 압축강도저하를 방지하며, 전단보강철근으로도 중요한 역할을 하여 교각의 전단강도를 증가시킨다. 그러나 이러한 횡방향 철근은 초기 설계에 의한 시공이 종료된 후 기존의 성능을 증가시키기 위하여 철근량을 증가하거나 단면의 변화를 주기에는 매우 어려운 일이다. 따라서 내진성능을 위한 단면력 증가를 위하여 다양한 재료의 보강재와 형식이 사용되고 있다. 본 연구에서는 원형교각 모델의 구조해석을 이용해 내진성능평가를 선행한 후 실험체를 제작, Helical Bar를 보강하여 준정적 실험을 통해 내진보강성능을 평가하였다. 압축설계강도 $f_{ck}=240kgf/cm^2$를 기준으로 교량등급 2등교인 일반적인 도로교의 1/4축소모형을 설계, 기초부는 $1,200{\times}600{\times}600$ (mm)으로 철근과 콘크리트로 구성하였으며, 기둥부는 직경 400mm, 높이 1,250mm 크기의 철근콘크리트 원형 교각 실험체를 제작하였다. 제작된 실험체는 총 3개로, 분류는 무보강 일반 실험체, Helical Bar 직경에 따른 분류, 보강간격에 따른 분류로 나누어진다.

  • PDF

Seismic Performance Evaluation of Flat Column Dry Wall System and Wall Slab System Structures (무량복합 및 벽식 구조시스템의 내진성능평가)

  • Kang, Hyungoo;Lee, Minhee;Kim, Jinkoo
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.25 no.3
    • /
    • pp.259-266
    • /
    • 2012
  • In this paper the seismic performance of a flat plate wall system structure was evaluated based on the ATC-63 approach, and the results were compared with those of a wall slab structure having the same size. As analysis model structures, a twelve story flat plate wall structure and a wall slab structure were designed based on the KBC-2009, and their seismic performances and collapse behaviors were evaluated by nonlinear static and incremental dynamic analyses(IDA). It was observed that the flat plate wall structure was designed with smaller amount of reinforced concrete, and showed slightly larger displacement response compared with those of the wall slab structure. The collapse margin ratios of the two structures obtained from the incremental dynamic analyses satisfied the limit states specified in the ATC-63, and the structures turned out to have enough capacity to resist the design level seismic load.

Progressive Collapse Resisting Capacity of Moment Frames with Viscous Dampers (점성감쇠기가 설치된 모멘트골조의 연쇄붕괴 저항성능)

  • Kim, Jin-Koo;Lee, Seung-Jun;Choi, Hyun-Hoon
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.23 no.5
    • /
    • pp.517-524
    • /
    • 2010
  • In this paper the progressive collapse resisting capacity of steel moment frames with viscous dampers was evaluated by nonlinear dynamic analysis. The effects of dampers installed in steel beam-column sub-assemblages with varying natural period and yield strength were evaluated after sudden removal of a column. According to the parametric study the vertical displacement general decreased as the damping ratio of the system increased, and the dampers were effective both in elastic and elasto-plastic systems. The nonlinear dynamic analysis results of the 15-story analysis models showed that the decrease in vertical deflection of the structure with 9m span length, which showed larger deflection, was more predominant than that of the structure with 6m span length.

A Numerical Study of the Performance Assessment of Coupled Thermo-Hydro-Mechanical (THM) Processes in Improved Korean Reference Disposal System (KRS+) for High-Level Radioactive Waste (수치해석을 활용한 향상된 한국형 기준 고준위방사성폐기물 처분시스템의 열-수리-역학적 복합거동 성능평가)

  • Kim, Kwang-Il;Lee, Changsoo;Kim, Jin-Seop
    • Tunnel and Underground Space
    • /
    • v.31 no.4
    • /
    • pp.221-242
    • /
    • 2021
  • A numerical study of the performance assesment of coupled thermo-hydro-mechanical (THM) processes in improved Korean reference disposal system (KRS+) for high-level radioactive waste is conducted using TOUGH2-MP/FLAC3D simulator. Decay heat from high-level radioactive waste increases the temperature of the repository, and it decreases as decay heat is reduced. The maximum temperature of the repository is below a maximum temperature criterion of 100℃. Saturation of bentonite buffer adjacent to the canister is initially reduced due to pore water evaporation induced by temperature increase. Bentonite buffer is saturated 250 years after the disposal of high-level radioactive waste by inflow of groundwater from the surrounding rock mass. Initial saturation of rock mass decreases as groundwater in rock mass is moved to bentnonite buffer by suction, but rock mass is saturated after inflow of groundwater from the far-field area. Stress changes at rock mass are compared to the Mohr-Coulomb failure criterion and the spalling strength in order to investigate the potential rock failure by thermal stress and swelling pressure. Additional simulations are conducted with the reduced spacing of deposition holes. The maximum temperature of bentonite buffer exceeds 100℃ as deposition hole spacing is smaller than 5.5 m. However, temperature of about 56.1% volume of bentonite buffer is below 90℃. The methodology of numerical modeling used in this study can be applied to the performance assessment of coupled THM processes for high-level radioactive waste repositories with various input parameters and geological conditions such as site-specific stress models and geothermal gradients.

Design Techniques for Levee Erosion (하천제방 침식에 대한 설계기법 검토)

  • Yoon, Kwang Seok;Lee, Seong Jun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2004.05b
    • /
    • pp.506-511
    • /
    • 2004
  • 본 연구에서는 제방의 침식에 대한 안정성 평가를 위하여 일본의 하천제방설계지침에서 사용하고 있는 설계기법을 도입하여 적용하였다. 일본은 호안 설계에 있어서 성능 규정에 의한 내력 및 외력을 산정하여 호안공의 안정성을 정량적으로 판단하고 있다. 국내 하천설계기준에서는 침식에 대해 호안을 설치토록 하고 있으나 확실한 안전성 평가기법은 제시되어 있지 않은 실정으로 호안공은 유속이 3m/s이상에서 설치하도록 제시하고 있어 호안공별 설계기준이 경험에 의존하게 된다. 이에 대해 정량적인 설계가 필요하며 적용성 검토를 위하여 2002년 대풍 '루사'와 2003년 태풍 '매미'에 의해 침식피해가 발생한 지점에 대해서 현장조사를 수행하고, 이를 정량적으로 해석함으로써 침식에 대한 설계기법에 대한 검토를 수행하였다. 본 연구에서는 제방 비탈면이 식생으로 보호된 경우와 호안공(호안블럭, 돌망태 등)이 설치된 경우에 대해서 안정성을 해석하였으며, 내${\cdot}$외력 산정에 의한 안정성 평가의 적용성을 확인하였다.

  • PDF

Damage Distribution Rule of Weak Beam Type Multi-Story Steel Frames Influenced by Strength and Stiffness Ratios of Beam and Column (보 붕괴형 메커니즘을 가지는 강구조 다층골조의 손상분포)

  • Oh, Sang-Hoon;Ryu, Hong-Sik;Moon, Tae-Sup
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.9 no.5 s.45
    • /
    • pp.53-61
    • /
    • 2005
  • In order to evaluate the limit earthquake resistance of multi-story steel frames influenced by the strength and stiffness ratios of members, a series inelastic response analysis were carried out. From the analysis results, the damage distribution rules of multi-story steel frames were proposed. Conclusions are summarized as follows; 1)As the stiffness ratios of beam and column becomes small, the damage concentrates on the lower end of columns of the first story. 2) Considering the strength and stiffness ratios of the beam and column with weak beam type mechanism, the equations predicting the damage distribution of multi-story steel flames were proposed. 3) Through the equation which was supposed in this study, it is speculated that the damage distribution of the rigid or semirigid beam collapse type multi-story steel structure building can be predicted.

Fragility Curve of Steel Box Bridge Using RFPB Bearing (RFPB 받침을 사용한 Steel Box 교량의 손상도 곡선)

  • Lee, Jongheon;Seo, Sangmok;Kim, Woonhak
    • Journal of the Society of Disaster Information
    • /
    • v.7 no.3
    • /
    • pp.171-180
    • /
    • 2011
  • As a great earthquake hit east Japan recently, the interests for the necessity of earthquake resistant design and earthquake resistance ability of existent structures are much increased. The damage or collapse of a bridge, as a social overhead capital structure affects socially and economically. Thus the evaluation of earthquake resistance ability of these structures is very important. The reviewing methods for earthquake resistance ability are mostly deterministic. Although the deterministic methods are fit for the evaluation of safety of each member, they are not practical for the whole structure. For the evaluation of structural safety for earthquake, the method for the evaluation of fragility or damage is needed for some stages of damage. In this paper, fragility curves of steel box bridge using RFPB bearing for PGA, PGV, SA, SV, SI are constructed, and these are compared with the cases of FPB.