• Title/Summary/Keyword: 불확실성인자

Search Result 252, Processing Time 0.031 seconds

Corrosion Stability of Iron Artifacts after Treating with Water Treatment (수처리제를 사용한 철제유물의 부식 안정성 연구)

  • Jeong, Ji Hae
    • Journal of Conservation Science
    • /
    • v.33 no.5
    • /
    • pp.381-390
    • /
    • 2017
  • Desalination is the main focus of the stabilization of iron artifacts. However, drawbacks such as re-corrosion are noted due to the uncertainty in the elimination of the corrosive factors and artifacts. Several studies have been carried out on the effects of corrosion inhibitors to overcome these shortcomings. In this study, the effects of type 3 water treatment on corrosion inhibitors were investigated. Surfaces of samples that contained film corrosion inhibitors on their surfaces were analyzed. The results revealed that the surface rust was removed from the sample of type 1 No. 2 that was mainly composed of phosphate. The average weight reduction rates of re-corrosion samples were 0.58, 0.03, and 0.07% for type 1 No. 2, type 2 No. 2, and type 3 No. 2 respectively. The changes in the $Cl^-$ ion, a corrosive agent were found to be 28.60, -4.08, and -1.94 ppm for type 1 No. 2, type 2 No. 2, and type 3 No. 2 respectively. The water-treated films were analyzed by X-ray photoelectron spectroscopy (XPS). It was found that type 2 No. 2 had less Fe the basis metal, than that in type 3 No. 2 indicating much better film. Moreover, Si content was higher in type 2 No. 2, based on the silicate content, than in type 3 No. 2. They are speculated to be the reason or the formation of a better film. Type 1 No. 2, which is mainly composed of phosphate, would be inappropriate as a metal artifact conservation treatment. It was determined that type 2 No. 2 and type 3 No. 2 water treatments, which are mainly composed of silicate, provided excellent corrosion inhibiting effects. Corrosion inhibitors could be used as emergency treatment agents during the excavation of iron artifacts.

The Molecular Insight into the Vascular Endothelial Growth Factor in Cancer: Angiogenesis and Metastasis (암의 혈관내피 성장인자에 대한 분자적 통찰: 혈관신생과 전이)

  • Han Na Lee;Chae Eun Seo;Mi Suk Jeong;Se Bok Jang
    • Journal of Life Science
    • /
    • v.34 no.2
    • /
    • pp.128-137
    • /
    • 2024
  • This review discusses the pivotal role of vascular endothelial growth factors (VEGF) in angiogenesis and lymphangiogenesis, vital processes influencing vascular permeability, endothelial cell recruitment, and the maintenance of tumor-associated blood and lymphatic vessels. VEGF exerts its effects through tyrosine-kinase receptors, VEGFR-1, VEGFR-2, and VEGFR-3. This VEGF-VEGFR system is central not only to cancer but also to diseases arising from abnormal blood vessel and lymphatic vessel formation. In the context of cancer, VEGF and its receptors are essential for the development of tumor-associated vessels, making them attractive targets for therapeutic intervention. Various approaches, such as anti-VEGF antibodies, receptor antagonists, and VEGF receptor function inhibitors, are being explored to interfere with tumor growth. However, the clinical efficacy of anti-angiogenic agents remains uncertain and necessitates further refinement. The article also highlights the physiological role of VEGFs, emphasizing their involvement in endothelial cell functions, survival, and vascular permeability. The identification of five distinct VEGFs in humans (VEGF-A, VEGF-B, VEGF-C, VEGF-D, and PLGF) is discussed, along with the classification of VEGFRs as typical receptor tyrosine kinases with distinct signaling systems. The family includes VEGFR-1 and VEGFR-2, crucial in tumor biology and angiogenesis, and VEGFR-3, specifically involved in lymphangiogenesis. Overall, this review has provided a comprehensive overview of VEGF and VEGFR, detailing their roles in various diseases, including cancer. This is expected to further facilitate the utilization of VEGF and VEGFR as therapeutic targets.

Analysis of the Disposal Tunnel and Disposal Pit Spacing for the Spent Fuel Repository Layout (사용후핵연료 지하 처분장 배치를 위한 처분공 및 처분터널 간격 분석)

  • Lee, Jong-Youl;Lee, Yang;Choi, Heui-Joo;Choi, Jong-Won
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.4 no.4
    • /
    • pp.393-400
    • /
    • 2006
  • In design of a deep geological repository for the high level wastes, it is very important that the temperature of the bentonite block should not be over $100^{\circ}C$ to maintain the integrity of the bentonite buffer block from the decay heat. In this study, for the layout of the repository to meet the requirement, the analysis of the disposal tunnel and disposal pit spacing was carried out. To do this, based on the reference repository concept, several cases of cooling times and disposal tunnel and disposal pit spacing were compared. The thermal stabilities of the disposal systems were analyzed in terms of the cooling time and spacing. The results showed that it was more desirable to determine the layout of the repository in terms of disposal pit spacing than the disposal tunnel spacing. The results of these analyses can be used in the deep geological repository design. The detailed analyses with the exact site characteristics data will reduce the uncertainty of the results.

  • PDF

Dam Break Analysis with HEC-HMS and HEC-RAS (HEC-HMS와 HEC-RAS를 이용한 댐 붕괴 해석)

  • Hong, Seung-Jin;Kim, Soo-Jun;Kim, Hung-Soo;Kyung, Min-Soo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.4B
    • /
    • pp.347-356
    • /
    • 2009
  • This study simulates the dam break situation by a probable maximum precipitation of Soyang-River Dam using HEC-HMS model and HEC-RAS model and compares the simulated results. The probable maximum precipitation was calculated using the flood event of the typhoon Rusa occurred in 2002 and using the mean areal precipitation of the Gangreung region and the moisture maximization method. The estimated probable maximum precipitations were compared for the duration of 6, 12, 18, and 24 hrs and were used as input data for the HEC-HMS model. Moreover, the inflow data calculated by HEC-HMS were utilized as ones for HEC-RAS, and then unsteady flow analysis was conducted. The two models were used for the dam break analysis with the same conditions and the peak flow estimated by HEC-HMS was larger than that of the HEC-RAS model. The applicability of two models was performed from the dam break analysis then we found that we could simulate more realistic peak flow by HEC-RAS than HEC-HMS. However, when we need more fast simulation results we could use HEC-HMS. Therefore, we may need the guidelines for the different utilizations with different purposes of two models. Furthermore, since the two models still include uncertainties, it is important to establish more detailed topographical factors and data reflecting actual rivers.

Validation of ECOSTRESS Based Land Surface Temperature and Evapotranspiration (PT-JPL) Data Across Korea (국내에서 ECOSTRESS 지표면 온도 및 증발산(PT-JPL) 자료의 검증)

  • Park, Ki Jin;Kim, Ki Young;Kim, Chan Young;Park, Jong Min
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.44 no.5
    • /
    • pp.637-648
    • /
    • 2024
  • The frequency of extreme weather events such as heavy and extreme rainfall has been increasing due to global climate change. Accordingly, it is essential to quantify hydrometeorological variables for efficient water resource management. Among the various hydro-meteorological variables, Land Surface Temperature (LST) and Evapotranspiration (ET) play key roles in understanding the interaction between the surface and the atmosphere. In Korea, LST and ET are mainly observed through ground-based stations, which also have limitation in obtaining data from ungauged watersheds, and thus, it hinders to estimate spatial behavior of LST and ET. Alternatively, remote sensing-based methods have been used to overcome the limitation of ground-based stations. In this study, we evaluated the applicability of the National Aeronautics and Space Administration's (NASA) ECOsystem Spaceborne Thermal Radiometer Experiment on Space Station (ECOSTRESS) LST and ET data estimated across Korea (from July 1, 2018 to December 31, 2022). For validation, we utilized NASA's MODerate Resolution Imaging Spectroradiometer (MODIS) data and eddy covariance flux tower observations managed by agencies under the Ministry of Environment of South Korea. Overall, results indicated that ECOSTRESS-based LSTs showed similar temporal trends (R: 0.47~0.73) to MODIS and ground-based observations. The index of agreement also showed a good agreement of ECOSTRESS-based LST with reference datasets (ranging from 0.82 to 0.91), although it also revealed distinctive uncertainties depending on the season. The ECOSTRESS-based ET demonstrated the capability to capture the temporal trends observed in MODIS and ground-based ET data, but higher Mean Absolute Error and Root Mean Square Error were also exhibited. This is likely due to the low acquisition rate of the ECOSTRESS data and environmental factors such as cooling effect of evapotranspiration, overestimation during the morning. This study suggests conducting additional validation of ECOSTRESS-based LST and ET, particularly in topographical and hydrological aspects. Such validation efforts could enhance the practical application of ECOSTRESS for estimating basin-scale LST and ET in Korea.

Analysis of the Optimal Separation Distance between Multiple Thermal Energy Storage (TES) Caverns Based on Probabilistic Analysis (확률론적 해석에 기반한 다중 열저장공동의 적정 이격거리 분석)

  • Park, Dohyun;Kim, Hyunwoo;Park, Jung-Wook;Park, Eui-Seob;Sunwoo, Choon
    • Tunnel and Underground Space
    • /
    • v.24 no.2
    • /
    • pp.155-165
    • /
    • 2014
  • Multiple thermal energy storage (TES) caverns can be used for storing thermal energy on a large scale and for a high-aspect-ratio heat storage design to provide good thermal performance. It may also be necessary to consider the use of multiple caverns with a reduced length when a single, long tunnel-shaped cavern is not suitable for connection to aboveground heat production and injection equipments. When using multiple TES caverns, the separation distance between the caverns is one of the significant factors that should be considered in the design of storage space, and the optimal separation distance should be determined based on a quantitative stability criterion. In this paper, we described a numerical approach for determining the optimal separation distance between multiple caverns for large-scale TES utilization. For reliable stability evaluation of multiple caverns, we employed a probabilistic method which can quantitatively take into account the uncertainty of input parameters by probability distributions, unlike conventional deterministic approaches. The present approach was applied to the design of a conceptual TES model to store hot water for district heating. The probabilistic stability results of this application demonstrated that the approach in our work can be effectively used as a decision-making tool to determine the optimal separation distance between multiple caverns. In addition, the probabilistic results were compared to those obtained through a deterministic analysis, and the comparison results suggested that care should taken in selecting the acceptable level of stability when using deterministic approaches.

Analysis of vertical root fracture in endodontically versus nonendodontically treated teeth on patients with periodontitis (치주질환자에서 근관치료의 유무에 따른 수직 치근 파절의 실태분석)

  • Kim, Myung-Jun;Jang, Hyun-Seon;Kim, Dong-Kie;Kim, Byung-Ock
    • Journal of Periodontal and Implant Science
    • /
    • v.35 no.2
    • /
    • pp.413-426
    • /
    • 2005
  • 수직 치근파절은 특이성을 나타내지 않기 때문에 치과의사가 정확한 진단을 하기 어렵다. 따라서 수직 치근파절의 임상적 특징, 진단적 증상을 파악하여 향후 근관치료된 치아나 치료되지 않은 치아에서 수직 치근파절의 유발인자와의 관련성 및 고찰을 통해 수직 치근파절의 예방 및 치료에 응용할 수 있을 것으로 생각된다. 연구대상은 조선대학교 부속치과병원 치주과에 내원한 환자 중 최근 2년간 144명의 환자에서 근관치료를 받았거나 받지 않았던 치아 중 임상적 및 방사선학적으로 수직 치근파절로 진단된 156개의 증례를 대상으로 하였다. 모든 불확실한 증례에서 수직 지근파절의 최종 진단은 외과적 탐지를 통해 이루어졌고, 금이 간 치아와 관련될 수 있는 치근파절의 증례의 경우는 제외되었다. 근관치료된 치아와 치료되지 않은 치아, 환자의 나이와 성별, 치아종류 및 파절된 치근부위, 자각증상의 유무를 기준으로 각각의 수치와 백분율로 분류하였다. 수직 치근파절의 증상과 증후별로 분류하였으며, 진단방법에 의한 분류, 치료방법에 따른 분류, 근관 치료 후 수직 치근파절이 발생한 기간에 따른 분류를 시행하고 통계분석을 하여 다음과 같은 결과를 얻었다. 1. 근관치료를 받지 않았던 치아의 수직 치근파절의 발생율은 58%였다. 2. 성별에 따른 발생률에 있어서 남성의 호발양상을 나타내었다. 3. 근관치료된 치아에 있어서 치료되지 않은 치아에 비해 호발연령이 낮았다. 4. 전치부의 수직 치근파절은 관찰되지 않았으며 특히, 강한 교합력을 필요로 히는 구치부에서의 높은 발생율을 나타냈다. 5. 수직 치근파절의 가장 주된 증상 및 증후는 깊은 치주낭 깊이였다. 6. 근관 치료 후 수직 치근파절이 발생한 기간은 평균 5.7년이었다. 7. 다수 증례에 있어서 3개 이하의 결손치를 가졌고, 자각증상이 나타났다. 이상의 결괴에서 한국인에 있어서 근관치료를 받지 않은 치아의 수직 치근파절은 드문 현상이 아님을 알 수 있었고 남성과 구치부에 있어서의 높은 발생율을 알 수 있었다. 그 이유로는 강한 교합력, 딱딱한 음식의 저작습관, 치조골 흡수에 따른 낮은 저항성, 골 유연성의 저하 등으로 여겨진다. 그러나, 수직 치근파절은 아직까지 정확한 진단을 내리기는 여전히 어려운 상태이며, 이를 위한 다양한 진단방법 및 더 나은 연구가 필수적이라 하겠다. 그리고, 향후 보다 많은 증례에 대한 분석, 치주질환에 이환되지 않은 경우의 분석, 치료 후 생존 기간에 대한 고찰 등도 필요하리라 사료된다.

Evaluation of the Clark Unit Hydrograph Parameters Considering Basin and Meteorologic at Conditions : 1. Selection and Analysis of Representative Storm Events (유역 및 기상상태를 고려한 Clark 단위도의 매개변수 평가: 1. 대표 호우사상의 선정 및 분석)

  • Yoo, Chul-Sang;Kim, Kee-Wook;Lee, Ji-Ho
    • Journal of Korea Water Resources Association
    • /
    • v.40 no.2 s.175
    • /
    • pp.159-170
    • /
    • 2007
  • This study evaluated the parameters of Clark unit hydrograph (UH) estimated using the rainfall-runoff measurements and evaluated their variability. This also includes the quantification of basin and meteorological factors using probability density functions, selection of storm events with mean affecting factors, and derivation of average parameters of the Clark UH from storm events selected. Summarizing the results from this procedure are as follows. (1) It is not easy to avoid much uncertainty on the decision of runoff characteristics (that is, the concentration time and storage coefficient) even with some rainfall-runoff events are available. (2) As the distribution function of concentration time is very skewed, a simple arithmetic mean may lead a biased estimate. That is, the arithmetic mean based on the normal distribution can not be representative anymore. The mode may well be the representative in this case. On the other hand, the storage coefficient shows a symmetric distribution function, so the arithmetic mean may be used use for its representative. For the basin in this study, the concentration time in this study is estimated to be about 7 hours, and the storage coefficient about 22 hours.

Analysis of Solute Transport based on Electrical Resistance Measurements from Laboratory Column Tests (전기저항센서가 부착된 주상실험기에서 측정된 전기저항값을 이용한 용질의 이동해석)

  • Kim, Yong-Sung;Kim, Jae-Jin;Park, Junboum
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.4C
    • /
    • pp.231-238
    • /
    • 2008
  • A column testing device capable of measuring the electrical resistivity of soil at 3 different locations was developed to verify applicability of bulk electrical conductivity (BEC) breakthrough curves in monitoring contaminant transport. Tracer injection tests were conducted with three different types of saturated sands to obtain average linear velocities and longitudinal hydrodynamic dispersion coefficients based on BEC breakthrough curves and effluent solute breakthrough curves. Comparative analysis of transport parameters obtained from curve fitting the results into the analytical solutions confirmed the validity of resistance measurements in estimating time-continuous resident solute concentration. Under the assumption that a linear relationship exists between ${\sigma}_{sat}-{\sigma}_w-C$, the BEC breakthrough curves are able to effectively reduce the laborious and time-consuming processes involved in the conventional method of sampling and analysis. In order to reduce possible uncertainties in analyzing the BEC breakthrough curves, it was recommended that resistance measurements take place nearby the effluent boundary. In addition, a sufficient electrical contrast or difference in the electrical conductivity of the influent and the saturating solution is required to conduct reliable analysis.

A Study on the Characteristics of Enterprise R&D Capabilities Using Data Mining (데이터마이닝을 활용한 기업 R&D역량 특성에 관한 탐색 연구)

  • Kim, Sang-Gook;Lim, Jung-Sun;Park, Wan
    • Journal of Intelligence and Information Systems
    • /
    • v.27 no.1
    • /
    • pp.1-21
    • /
    • 2021
  • As the global business environment changes, uncertainties in technology development and market needs increase, and competition among companies intensifies, interests and demands for R&D activities of individual companies are increasing. In order to cope with these environmental changes, R&D companies are strengthening R&D investment as one of the means to enhance the qualitative competitiveness of R&D while paying more attention to facility investment. As a result, facilities or R&D investment elements are inevitably a burden for R&D companies to bear future uncertainties. It is true that the management strategy of increasing investment in R&D as a means of enhancing R&D capability is highly uncertain in terms of corporate performance. In this study, the structural factors that influence the R&D capabilities of companies are explored in terms of technology management capabilities, R&D capabilities, and corporate classification attributes by utilizing data mining techniques, and the characteristics these individual factors present according to the level of R&D capabilities are analyzed. This study also showed cluster analysis and experimental results based on evidence data for all domestic R&D companies, and is expected to provide important implications for corporate management strategies to enhance R&D capabilities of individual companies. For each of the three viewpoints, detailed evaluation indexes were composed of 7, 2, and 4, respectively, to quantitatively measure individual levels in the corresponding area. In the case of technology management capability and R&D capability, the sub-item evaluation indexes that are being used by current domestic technology evaluation agencies were referenced, and the final detailed evaluation index was newly constructed in consideration of whether data could be obtained quantitatively. In the case of corporate classification attributes, the most basic corporate classification profile information is considered. In particular, in order to grasp the homogeneity of the R&D competency level, a comprehensive score for each company was given using detailed evaluation indicators of technology management capability and R&D capability, and the competency level was classified into five grades and compared with the cluster analysis results. In order to give the meaning according to the comparative evaluation between the analyzed cluster and the competency level grade, the clusters with high and low trends in R&D competency level were searched for each cluster. Afterwards, characteristics according to detailed evaluation indicators were analyzed in the cluster. Through this method of conducting research, two groups with high R&D competency and one with low level of R&D competency were analyzed, and the remaining two clusters were similar with almost high incidence. As a result, in this study, individual characteristics according to detailed evaluation indexes were analyzed for two clusters with high competency level and one cluster with low competency level. The implications of the results of this study are that the faster the replacement cycle of professional managers who can effectively respond to changes in technology and market demand, the more likely they will contribute to enhancing R&D capabilities. In the case of a private company, it is necessary to increase the intensity of input of R&D capabilities by enhancing the sense of belonging of R&D personnel to the company through conversion to a corporate company, and to provide the accuracy of responsibility and authority through the organization of the team unit. Since the number of technical commercialization achievements and technology certifications are occurring both in the case of contributing to capacity improvement and in case of not, it was confirmed that there is a limit in reviewing it as an important factor for enhancing R&D capacity from the perspective of management. Lastly, the experience of utility model filing was identified as a factor that has an important influence on R&D capability, and it was confirmed the need to provide motivation to encourage utility model filings in order to enhance R&D capability. As such, the results of this study are expected to provide important implications for corporate management strategies to enhance individual companies' R&D capabilities.