• 제목/요약/키워드: 불확도 평가

검색결과 263건 처리시간 0.024초

원자현미경용 XY 스캐너의 아베 오차 최소화를 위한 최적 설계 및 원자 현미경의 측정 불확도 평가 (Optimal design of a flexure hinge-based XY AFM scanner for minimizing Abbe errors and the evaluation of measuring uncertainty of AFM system)

  • 김동민;이동연;권대갑
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.1438-1441
    • /
    • 2005
  • To establish of standard technique of nano-length measurement in 2D plane, new AFM system has been designed. In this system, measurement uncertainty is dominantly affected by the Abbe error of XY scanning stage. No linear stage is perfectly straight; in other words, every scanning stage is subject to tilting, pitch and yaw motion. In this paper, an AFM system with minimum offset of XY sensing is designed. And XY scanning stage is designed to minimize rotation angle because Abbe errors occur through the multiply of offset and rotation angle. To minimize the rotation angle optimal design has performed by maximizing the stiffness ratio of motion direction to the parasitic motion direction of each stage. This paper describes the design scheme of full AFM system, especially about XY stage. Full range of fabricated XY scanner is $100um\times{100um}$. And tilting, pitch and yaw motion are measured by autocollimator to evaluate the performance of XY stage. Using this AFM system, 3um pitch specimen was measured. As a result, the uncertainty of total system has been evaluated.

  • PDF

두 점 교정법을 이용한 담배 연기 성분 중 니코틴 분석 결과에 대한 불확도 평가 (Uncertainty Evaluation of Nicotine in Cigarette Mainstream Smoke Using Two Point Re-calibration Method)

  • 김미주;지상운;황건중;이문수;조성일
    • 한국연초학회지
    • /
    • 제26권2호
    • /
    • pp.168-178
    • /
    • 2004
  • Uncertainty of final measurement results considering main uncertainty sources being in nicotine of mainstream smoke was estimated. This study was accomplished by using the ISO 'The Guide to the Expression of Uncertainty in Measurement'. Using the two point re-calibration method, uncertainty for nicotine concentration was calculated considering the uncertainty sources of each step. The concentration and uncertainty of nicotine in mainstream smoke was estimated as $153.95{\pm}17.84\;{\mu}g/mL\;(0.77\pm0.089 mg/cig)$. The expanded uncertainty was $17.84 {\mu}g/mL(\pm0.089 mg/cig).$ The reported expanded uncertainty of the measurement is stated as the standard uncertainty of measurement multiplied by a coverage factor of 2, which for a normal distribution corresponds to a coverage probability of approximately $95\%$ The former expression indicates the conversion concentration into the sample.

유한요소 해석을 이용한 3상 유도전동기의 효율 불확도 평가 (Evaluation of Efficiency Uncertainty for Three-phase Induction Motor using Finite Element Analysis)

  • 이호현;박한석;전희득;우경일
    • 전기학회논문지P
    • /
    • 제66권4호
    • /
    • pp.163-168
    • /
    • 2017
  • This paper presented an evaluation method for the efficiency uncertainty of a three-phase induction motor using finite element analysis. The motor efficiency in the finite element analysis is calculated by the loss separation method as in the actual test. In the process of evaluating the efficiency uncertainty, the difference between the finite element analysis and the actual test is the method of calculating the type-A / B standard uncertainty of the input quantity to estimate the efficiency and each losses. For the input quantities which can confirm the instantaneous values with respect to time, the type-A standard uncertainty in the finite element analysis is calculated from the RMS values or average values having separate periods in the steady state. And, the type-B standard uncertainty in the finite element analysis is assumed to be zero. Also, this paper compared and analyzed the efficiency uncertainty evaluated by the proposed method and the efficiency uncertainty through the actual test.

10의 -10승 수준에서 조셉슨 전압표준기 불확도 평가 (Uncertainty Evaluation of Josephson Voltage Standard in the level of $10^{-10}$)

  • 김규태;김문석;정연욱;김완섭;송운
    • Progress in Superconductivity
    • /
    • 제9권1호
    • /
    • pp.56-61
    • /
    • 2007
  • The most recent improvement in the 10 V array system was carried out with focusing on noise reduction. We have evaluated the uncertainty of the 10 V Josephson array system after the improvement. The uncertainty evaluation of 10 V standard included a comparison with a programmable Josephson array system at 1 V. Every contribution to the measurement uncertainty was evaluated in the level of $10^{-10}$. The estimated combined uncertainty was found to be approximately $10^{-9}$ at 10 V, which was limited only by the indirect verifying method. In the near future, a direct comparison with another 10 V Josephson voltage standard is expected to be carried out to provide more accurate uncertainty evaluation for the KRISS Josephson voltage standard.

  • PDF

오존 SRP의 제작과 측정 불확도 평가 (Development of a Candidate Equipment for Ozone SRP and its Uncertainty Evaluation)

  • 정규백;우진춘;이진홍
    • 한국대기환경학회지
    • /
    • 제17권4호
    • /
    • pp.313-319
    • /
    • 2001
  • The development of ozone SRP (Standard Reference Photometer) designated as a G-7 project by the Korean Ministry of Environment began 1997 and is now nearly completed. With the completion of the ozone SRP we will not only acquire a qualification to participate in the international ozone calibration system but also enhance calibration credibility of ozone similarly to that of other ambient air pollution monitors. As the ozone SRP uses highly cleaned blank air that can be distinguished from general ozone analyzer, it is possible to reduce errors associated with the determination of ozone via elongation of the absorption length as long as 1 meter In addition, gas chopping method hat been adopted to cut down interference of other substances and time drift. Furthermore, the system has also been modified to minimize the strayed ultra-violet noise along the light path. In this paper, a new method for uncertainty evaluation has been introduced, which is guided by the ISO (International Standard Organization) GUM (Guide to the Expression of Uncertainty in Measurement) through assessments of the uncertainty type B (that was impossible to estimate before) as well as the uncertainty type A (based on statistics).

  • PDF

CTD 교정 시스템 구축 및 불확도 평가 (Establishment of CTD Calibration System and Uncertainty Estimation)

  • 이정한;황근춘;김은수;이승훈
    • Ocean and Polar Research
    • /
    • 제36권1호
    • /
    • pp.77-85
    • /
    • 2014
  • The quality control of ocean observations data is becoming a major issue as real-time observational data and information services have increased recently. Therefore, it is necessary for oceanographic instruments to calibrate. In this paper, we first introduce the CTD calibration system and traceability. Next, CTD calibration procedures and estimation of uncertainty of measurement are described. The expanded uncertainty (k = 2) of the temperature, pressure and conductivity are 0.$0.003^{\circ}C$, $6.0{\times}10^{-5}$ and 0.006 mS/cm respectively. Finally, the excellence of CTD calibration and its measurement capability has been proven by comparing the inter-calibration result of KIOST and Sea-Bird Electronics (SBE). CTD calibration residuals are less than ${\pm}0.0001^{\circ}C$, ${\pm}0.001$ MPa, ${\pm}0.0001$ S/m for SBE 3plus temperature sensor, SBE 19plus pressure sensor and SBE 4C conductivity sensor respectively.

대기 중 NO2 측정의 불확도 평가 (Evaluation of Uncertainties in the Measurement of Ambient NO2 Level)

  • 이진홍;임종명;우진춘
    • 한국대기환경학회지
    • /
    • 제18권5호
    • /
    • pp.355-362
    • /
    • 2002
  • There has been relatively a few studies that focused on evaluation of uncertainty for standard methods by which criteria pollutants are analyzed in ambient air. Especially, uncertainty evaluation has not been made yet for sampling and analysis of airborne NO$_2$. Ambient NO$_2$ has been thought to be a major criteria pollutant worldwide because of the potential of ozone formation as well as of its own toxicity. In this study, we tried to assess uncertainties associated with the every step of sampling and of analytical procedure of Griess-Saltzman method. Quality assurance (QA) and quality control (QC) were also emphasized with the uncertainty characterization. The use of Griess-Saltzman method for ambient NO$_2$ analysis showed very uniform daily concentration distribution with the mean of 10.8 ppb and the standard deviation of 1.08ppb during the sampling period. However, seven daily samples collected at the same sampling time and place exhibited highly different concentration distribution. Therefore, we evaluated uncertainties associated with sampling and analysis through the precise application of ISO Guide. Estimates of expanded uncertainties for a total of 62 samples fell in a relatively broad range of 5.17% to 11.85%. On the other hand. the expanded uncertainties were smaller for the high concentration range of greater than 15ppb.

핵심국제비교용 물의 삼중점 셀 제작과 비교 실험 및 불확도 평가 (Construction and Comparison Measurement of Triple Point Water Cells for using Key Comparison and Evaluation of Uncertainty)

  • 강기훈;김용규;감기술
    • 센서학회지
    • /
    • 제13권2호
    • /
    • pp.114-120
    • /
    • 2004
  • The $Comet{\acute{e}}$ Consultatif de $Thermom{\acute{e}}trie$ (CCT) under the Comete International des Poids et Measures (CIPM) has decided to perform the Key Comparison (KC) for triple point of water cells used as a reference fixed point of thermometry at the 21st meeting held at November 2001, and the Bureau International des Poids et Measures (BIPM) has been nominated as a KC coordinator. According to the KC protocol prepared by BIPM, KRISS performed the KC experiments and evaluate a uncertainty. The temperature difference between two reference cells for the Korea Research Institute of Standards and Science (KRISS) and a test cell for the transfer standard, which is moved to BIPM was 0.024 mK and the combined standard uncertainty evaluated 0.055 mK.

액체용 유량계교정시스템의 교정측정능력 평가 (CMC Evaluation of Flowmeter Calibration System for Liquid)

  • 이동근;김종섭;박태진;박종호
    • 한국유체기계학회 논문집
    • /
    • 제17권4호
    • /
    • pp.5-10
    • /
    • 2014
  • It is possible for the nation's largest flowmeter calibration system in K-water to calibrate flow rate up to $2,700m^3/h$ and diameter 800mm. However, the calibration and measurement capability of K-water's system is not satisfied in comparison with other developed countries. In this study, we find the dominant factors related to the uncertainty of weight and time measurement for gravimetric flowmeter calibration system. As a results of improving the system, the combined standard uncertainty has been improved $1.099{\times}10^{-3}$ to $2.332{\times}10^{-4}$. So calibration and measurement capability got 0.08 percent of the relative expanded uncertainty for maximum flow rate using the coverage factor(k=2).

K-대역 감소량 표준기의 설계 및 제작 (Design and Fabrication of K-band Attenuation Standard)

  • 이주광;김정환;강진섭;강태원
    • 한국전자파학회논문지
    • /
    • 제17권4호
    • /
    • pp.387-392
    • /
    • 2006
  • K-대역에서 동작하는 3.5 mm 동축형 감쇠량 표준기를 개발하고 그 측정 불확도를 평가하였다. 전력비 전달방식의 4개의 모듈로 구성된 이 표준기는 18 GHz부터 26.5 GHz까지의 광대역에서 동작하며 각 모듈은 약 20 dB의 감쇠량을 가진다. 측정 가능한 최대 감쇠량은 80 dB이고 이때의 확장 불확도는 약 95% 신뢰수준에서 0.01 dB이다.