• Title/Summary/Keyword: 불확도 평가

Search Result 263, Processing Time 0.029 seconds

Uncertainty Analysis on Wind Speed Profile Measurements of LIDAR by Applying SODAR Measurements as a Virtual True Value (가상적 참값으로써 소다 측정자료를 적용한 라이다에 의한 풍속연직분포 측정의 불확도 분석)

  • Kim, Hyun-Goo;Choi, Ji-Hwi
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.4
    • /
    • pp.79-85
    • /
    • 2010
  • The uncertainty in WindCube LIDAR measurements, which are specific to wind profiling at less than 200m above ground levelin wind resource assessments, was analyzed focusing on the error caused by its volume sampling principle. A two-month SODAR measurement campaign conducted in an urban environment was adopted as the reference wind profile assuming that various atmospheric boundary layer shapes had been captured. The measurement error of LIDAR at a height z was defined as the difference in the wind speeds between the SODAR reference data, which was assumed to be a virtually true value, and the numerically averaged wind speed for a sampling volume height interval of $z{\pm}12.5m$. The pattern of uncertainty in the measurement was found to have a maximum in the lower part of the atmospheric boundary layer and decreased with increasing height. It was also found that the relative standard deviations of the wind speed error ratios were 6.98, 2.70 and 1.12% at the heights of 50, 100 and 150m above ground level, respectively.

Uncertainty Evaluation of Velocity Integration Method for 5-Chord Ultrasonic Flow Meter Using Weighting Factor Method (가중계수법을 이용한 5회선 초음파 유량계의 유속적분방법의 불확도 평가)

  • Lee, Ho-June;Lee, Kwon-Hee;Noh, Seok-Hong;Hwang, Sang-Yoon;Noh, Young-Ah
    • 유체기계공업학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.287-294
    • /
    • 2005
  • Flow rate measurement uncertainties of the ultrasonic flow meter are generally influenced by many different factors, such as Reynolds number, flow distortion, turbulence intensity, wall surface roughness, velocity integration method along the acoustic paths, and transducer installation method, etc. Of these influencing factors, one of the most important uncertainties comes from the velocity integration method. In the present study, a optimization weighting factor method for 5-chord, which is given by a function of the chord locations of acoustic paths, is employed to obtain the mean velocity in the flow through a pipe. The power law profile is assumed to model the axi-symmetric pipe flow and its results are compared with the present weighting factor concept. For an asymmetric pipe flow, the Salami flow model is applied to obtain the velocity profiles. These theoretical methods are also compared with the previous Gaussian, Chebyshev, and Tailor methods. The results obtained show that for the fully developed turbulent pipe flows with surface roughness effects, the present weighting factor method is much less sensitive than Chebyshev and Tailor methods, leading to a better reliability in flow rate measurement using the ultrasonic flow meters.

  • PDF

Uncertainty Assessment Using Monte Carlo Simulation in Gas Flow Measurement (기체 유량 측정에서 몬테 카를로 모사를 이용한 측정불확도 평가)

  • Lee, Dae-Sung;Yang, In-Young;Kim, Chun-Taek;Yang, Soo-Seok
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.12
    • /
    • pp.1758-1765
    • /
    • 2003
  • Monte Carlo simulation(MC) method was used as an uncertainty assessment tool for gas flow measurement in this paper. Uncertainty sources for gas flow measurement were analyzed, and probability distribution characteristics of each source were discussed. Detailed MC methodology was described including the effect of the number of simulation. The uncertainty result was compared with that of the conventional sensitivity coefficient method, and it was revealed that the results were different from each other for this particular gas flow measurement case of which the modelling equation was nonlinear. The MC was comparatively simple, convenient and accurate as an uncertainty assessment method, especially in cases of complex, nonlinear measurement modelling equations. It was noted that the uncertainty assessment method should be selected carefully according to the mathematical characteristics of the measurement.

Design and Evaluation of Uncertainty for 6-component Force/Moment Calibration Machine (6분력 힘/모멘트 교정기의 설계 및 불확도 평가)

  • 김갑순;강대임;송후근
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.68-72
    • /
    • 1997
  • This paper presents the design and the evaluation of the 6-component force/moment calibration machine which h a s t h e maximum capacities of 500 N in forces and 50 Nm in moments. This calibration machine consists of body. fixture. force generating system, moment generating system. The expanded uncertainty of the calibration machine is evaluated by calculating the A type uncertainty. $U_A$ and B type uncertainty, $U_B$. The evaluation results. this system has the expanded uncertainty of less than $2{\times}10^[-2]$ in respective force and moment components.

  • PDF

Estimation and Uncertainty Evaluation on Mass Flow Rate of Air Intake by Using Air Data (비행정보를 이용한 흡입구의 공기유량 추정 및 불확도 평가)

  • Park, Iksoo;Park, Jungwoo;Ki, Taeseok;Choi, Jin;Lee, Juyoung
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.22 no.3
    • /
    • pp.14-20
    • /
    • 2018
  • An estimation law of air mass flow rate for high speed engine control is presented. The variables of mass estimation equations are modified to measurable variables which can be obtained during flight, and the effectiveness of each variable to the estimation accuracy is evaluated. The equation is modified to a simplified form, and the uncertainty is evaluated. In addition, reference data for the selection of estimation methods is suggested by considering the sensitivity analysis of sensor error.

Evaluation for Standard Current Transformers and Current Transformers under Test Using Precise Standard Resistors (정밀저항을 이용한 표준 변류기와 피측정 변류기의 평가)

  • Song, Eui-Sup;Kim, Yoon-Hyoung;Jung, Jae-Kap
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.2083_2084
    • /
    • 2009
  • 본 연구에서는 변류기 비교측정 시스템과 정밀저항을 이용 하여 변류기의 오차에 연관되는 인자를 측정함으로써 피측정 변류기의 절대 평가를 하고 그 결과를 이용하여 표준 변류기를 평가 하였다. 한편 기존에 60 Hz 에 적용하였던 실험을 이번 실험에서는 60 Hz 뿐만 아니라 50 Hz 까지 확장하여 실험 하였다. 이 기술의 타당성을 검증하기 위해 실험에 사용된 동일한 변류기에 대한 해외 국가 표준기관의 비오차 및 위상오차와 비교 하였고 그 차이값이 확장 불확도 내에서 일치 함을 확인 하였다.

  • PDF

Optimal design of a flexure hinge-based XY AFM scanner for minimizing Abbe errors and the evaluation of pitch measuring uncertainty of a nano-accuracy AFM system (XY 스캐너의 아베 오차 최소화를 위한 최적 설계 및 나노 정밀도의 원자 현미경 피치 측정 불확도 평가)

  • Kim Dong-Min;Lee Dong-Yeon;Gweon Dae-Gab
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.6 s.183
    • /
    • pp.96-103
    • /
    • 2006
  • To establish of standard technique of nano-length measurement in 2D plane, new AFM system has been designed. In the long range (about several tens of ${\mu}m$), measurement uncertainty is dominantly affected by the Abbe error of XY scanning stage. No linear stage is perfectly straight; in other words, every scanning stage is subject to tilting, pitch and yaw motion. In this paper, an AFM system with minimum offset of XY sensing is designed. And XY scanning stage is designed to minimize rotation angle because Abbe errors occur through the multiply of offset and rotation angle. To minimize the rotation angle optimal design has performed by maximizing the stiffness ratio of motion direction to the parasitic motion direction of each stage. This paper describes the design scheme of full AFM system, especially about XY stage. Full range of fabricated XY scanner is $100{\mu}m\times100{\mu}m$. And tilting, pitch and yaw motion are measured by autocollimator to evaluate the performance of XY stage. As a result, XY scanner can have good performance. Using this AFM system, 3um pitch specimen was measured. The uncertainty of total system has been evaluated. X and Y direction performance is different. X-direction measuring performance is better. So to evaluate only ID pitch length, X-direction scanning is preferable. Its expanded uncertainty(k=2) is $\sqrt{(3.96)^2+(4.10\times10^{-5}{\times}p)^2}$ measured length in nm.

Preparation of wastewater-based reference materials for heavy metal analysis and interlaboratory study (중금속분석용 폐수표준물질 제조 및 실험실간 비교평가)

  • Kim, Young-Hee;Song, Ki-Bong;Shin, Sun-Kyoung;Lee, Jung-Sub;Jeong, Gi-Taeg;Hong, Eun-Jin;Park, Jin-Ju;Yu, Suk-Min
    • Analytical Science and Technology
    • /
    • v.23 no.3
    • /
    • pp.295-303
    • /
    • 2010
  • In this study, the wastewater-based reference material (RM) was prepared and certified for 7 trace metal elements with evaluation of uncertainties. The RM was distributed to 25 laboratories for the interlaboratory comparison testing. The certified values and expanded uncertainties were derived using ISO guideline 35 and the standard uncertainties for homogenieties were 0.43~2.67% of certified values. The analytical results from the interlaboratory comparison testing showed normal distributions and the robust means from the interlaboratory comparison testing were higher than the certified values of the RM for all analytes.

Evaluation of the Measurement Uncertainty from the Standard Operating Procedures(SOP) of the National Environmental Specimen Bank (국가환경시료은행 생태계 대표시료의 채취 및 분석 표준운영절차에 대한 단계별 측정불확도 평가 연구)

  • Lee, Jongchun;Lee, Jangho;Park, Jong-Hyouk;Lee, Eugene;Shim, Kyuyoung;Kim, Taekyu;Han, Areum;Kim, Myungjin
    • Journal of Environmental Impact Assessment
    • /
    • v.24 no.6
    • /
    • pp.607-618
    • /
    • 2015
  • Five years have passed since the first set of environmental samples was taken in 2011 to represent various ecosystems which would help future generations lead back to the past environment. Those samples have been preserved cryogenically in the National Environmental Specimen Bank(NESB) at the National Institute of Environmental Research. Even though there is a strict regulation (SOP, standard operating procedure) that rules over the whole sampling procedure to ensure each sample to represent the sampling area, it has not been put to the test for the validation. The question needs to be answered to clear any doubts on the representativeness and the quality of the samples. In order to address the question and ensure the sampling practice set in the SOP, many steps to the measurement of the sample, that is, from sampling in the field and the chemical analysis in the lab are broken down to evaluate the uncertainty at each level. Of the 8 species currently taken for the cryogenic preservation in the NESB, pine tree samples from two different sites were selected for this study. Duplicate samples were taken from each site according to the sampling protocol followed by the duplicate analyses which were carried out for each discrete sample. The uncertainties were evaluated by Robust ANOVA; two levels of uncertainty, one is the uncertainty from the sampling practice, and the other from the analytical process, were then compiled to give the measurement uncertainty on a measured concentration of the measurand. As a result, it was confirmed that it is the sampling practice not the analytical process that accounts for the most of the measurement uncertainty. Based on the top-down approach for the measurement uncertainty, the efficient way to ensure the representativeness of the sample was to increase the quantity of each discrete sample for the making of a composite sample, than to increase the number of the discrete samples across the site. Furthermore, the cost-effective approach to enhance the confidence level on the measurement can be expected from the efforts to lower the sampling uncertainty, not the analytical uncertainty. To test the representativeness of a composite sample of a sampling area, the variance within the site should be less than the difference from duplicate sampling. For that, a criterion, ${i.e.s^2}_{geochem}$(across the site variance) <${s^2}_{samp}$(variance at the sampling location) was proposed. In light of the criterion, the two representative samples for the two study areas passed the requirement. In contrast, whenever the variance of among the sampling locations (i.e. across the site) is larger than the sampling variance, more sampling increments need to be added within the sampling area until the requirement for the representativeness is achieved.

Evaluation of RPL Glass Dosimeter Characteristics and Uncertainty Evaluation of Reading Correction Factors (유리선량계 특성평가 및 판독 보정인자에 대한 불확도 평가)

  • Seong-Yun Mok;Yeong-Rok Kang;Hyo-Jin Kim;Yong-Uk Kye;Hyun An
    • Journal of radiological science and technology
    • /
    • v.46 no.3
    • /
    • pp.219-229
    • /
    • 2023
  • In this study, basic characteristics such as reproducibility, linearity, and directionality of RPL glass dosimeters were evaluated to improve the reliability of dose evaluation through RPL glass dosimeters, and uncertainty elements such as sensitivity by glass element and magazine slot sensitivity were evaluated. Using a mathematical model to calibrate the measured values of the RPL glass dosimeter, the measurement uncertainty was calculated assuming an example. As a result of the characteristic evaluation, the RPL glass dosimeter showed excellent performance with a standard deviation of ±1% (1 SD) for the reproducibility of the reading process, a coefficient of determination for linearity of 0.99997. And the read-out of the RPL glass dosimeter are affected by the circular rotation direction of the glass dosimeter during irradiation, fading according to the period after irradiation, the number of laser pulses of the reader, and response degradation due to repeated reading, it is judged that measurement uncertainty can be reduced by irradiation and reading in consideration of these factors. In addition, it was confirmed that the dose should be determined by calculating the correction factors for the sensitivity of each element and, the sensitivity of each reading magazine slot. It is believed that the reliability of dosimetry using glass dosimeters can be improved by using a mathematical model for correction of glass dosimeter readings and calculating measurement uncertainty.