• Title/Summary/Keyword: 불확도측정

Search Result 337, Processing Time 0.024 seconds

A Study on the Treatment of Uncertainty in Linear Regression Method for Chemical Analysis (회귀식 사용에 따른 화학 분석 과정의 불확도 처리 연구)

  • Woo, Jin-Chun;Suh, JungKee;Lim, MyungChul;Park, MinSu
    • Analytical Science and Technology
    • /
    • v.16 no.3
    • /
    • pp.185-190
    • /
    • 2003
  • We applied modified least square method (MLS) and ordinary least square method (OLS) to 1st order equation for the comparison of the uncertainties calculated by these methods. The uncertainty calculated by OLS covered statistically safe interval because it was over-estimated in many cases of measurement and concentration level. But, if the uncertainty of the concentration as a reference value was comparably large (about 5% of the relative standard deviation of random scattering from the regression line and about 7% of relative standard uncertainty of reference values), then uncertainty calculated by OLS was seriously under-estimated at high concentration level. It was revealed that the calculated uncertainty didn't cover statistically safe interval at the stated confidence level. It was found that the method, MLS, described in the previously article would be valid for this calculation of uncertainty.

Evaluation and Quantification on the Sources of Uncertainty for Quality Assurance of the Air-Pollution Monitoring Stations (대기오염측정망의 측정 품질 보증을 위한 불확도 요소의 파악과 정량화)

  • 우진춘;문동민;김현호;임종명;이진홍;홍유덕;한진석;이석조
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2003.11a
    • /
    • pp.121-122
    • /
    • 2003
  • 현재, 대기 환경 자료의 정확한 분석을 위하여 정부와 지자체는 여러 종류의 대기 오염 측정망을 설치하여 운영하고 있다. 측정망으로부터 산출된 이러한 자료들의 품질은 대기 환경 학자 및 전문가들은 물론이고 일반 국민들의 일상적인 활동에도 중요한 영향을 미치고 있기 때문에, 측정 결과의 정화한 이해와 사용을 위한 품질 보증이 매우 중요한 실정에 있다. 그러나, 국제적인 수준의 품질 보증이 이루어지기 위해서는 측정 실험실의 인증 요건(ISO 17025) 및 측정 불확도 표기(ISO Guide) 등에 관한 국제적인 규격들의 적용이 매우 엄격하게 요구되고 있는 실정이다. (중략)

  • PDF

Development of the calibration procedure of the reference sound source and case study on the uncertainty evaluation (기준음원의 교정 절차 개발 및 불확도 평가 사례)

  • Jae-Gap Suh;Wan-Ho Cho
    • The Journal of the Acoustical Society of Korea
    • /
    • v.43 no.3
    • /
    • pp.344-350
    • /
    • 2024
  • A Reference Sound Source (RSS) is an important standard device employed in measuring sound power. The specifications of RSS is specified in international standards, and it is classified as a major calibration item in the field of acoustic metrology. Since the output power of RSS is affected by the supply voltage, each country needs to secure its own calibration service system. In this study, a procedure for calibrating a RSS is established based on the reverberant room conditions and uncertainty evaluation is conducted. Basically, the calibration procedure can apply a precision measurement process of acoustic power, and here, the measurement method using the reverberation chamber of ISO 3741 is applied. For this purpose, a measurement system is constructed, measurements are conducted with two types of RSS, and measurement uncertainty is evaluated. Through measurement examples, it is confirmed that the non-uniformity of the sound pressure distribution in the reverberation room and the volume measurement uncertainty contributed significantly to the overall uncertainty. Additionally, the influence of input voltage is experimentally examined to examine the uncertainty contribution that can be reflected in acoustic power measurements.

Quantifying Uncertainty of Vitamin C Determination in Infant Formula by Indophenol Titration Method (인도페놀 적정법에 의한 성장기용조제식 중 비타민 C 함량분석의 측정불확도 산정)

  • Jun, Jang-Young;Kwak, Byung-Man;Ahn, Jang-Hyuk;Kong, Un-Young
    • Korean Journal of Food Science and Technology
    • /
    • v.37 no.3
    • /
    • pp.352-359
    • /
    • 2005
  • Uncertainty involved during determination of vitamin C content in infant formula was quantified by indophenol titration method. Uncertainty sources in measurand, such as purity, weight, final volume of standard, volume of standard solution used for titration, sample weight, final volume of sample, extraction solution used for titration, titration of extraction solution and standard solution by indophenol solution were identified and used as parameters for combined standard uncertainty based on Guide to the expression of uncertainty in measurement (GUM) and Draft EURACHEM/CITAC Guide. Uncertainty parameters of each source in measurand were identified as resolution, reproducibility and stability of chemical balance, standard material purity, repeatability, reproducibility, end point of titration, 1 mL pipet, 5 mL autopipet, and 100 mL mass flask. Each uncertainty component was evaluated by types A and B and included to calculate combined uncertainty. Analytical test result for traceability under laboratorial conditions using Certified Reference Material (CRM) test was certified as $108.4{\pm}1.7mg/100g$, which was within CRM certification range of $114.6{\pm}6.6mg/100g$. Uncertainty test result of vitamin C content of 5 g sampling was $56.7{\pm}2.44mg/100g$. Uncertainty could be reduced by identification of uncertainty sources and components related with vitamin C determination by indophenol titration method and by decreasing uncertainty sources and components.

Absolute Test for a 4-inch Flat and Its Measurement Uncertainty (4인치 평면의 절대 측정 및 측정불확도 계산)

  • Kim, Su-Young;Song, Jae-Bong;Yang, Ho-Soon;Rhee, Hyug-Gyo
    • Korean Journal of Optics and Photonics
    • /
    • v.28 no.6
    • /
    • pp.339-345
    • /
    • 2017
  • The flatness of a reference flat plays an important role, from the calibration of an interferometer to the reference for a semiconductor or flat-panel display, etc. Especially if we order the flatness measurement outside Korea, we may spend more time and money. In this paper, we measured the flatness of a reference flat using a three-flat test, which is one of the absolute measurement methods, and calculated its measurement uncertainty. In the three-flat test we adopted, each flat is tested against another flat, with three unknown flats, using an interferometer. Among several three-flat tests, we adopted Griesmann's method which has a low measurement uncertainty and is less dependent on the experimental equipment. As a result, the measurement uncertainty was found to be less than 0.5 nm rms, which is very accurate for high-tech industrial applications.

Measurement Uncertainty for Calibration of EMI Dipole Antenna from 30 MHz to 1 GHz (30 MHz에서 1 GHz 대역 EMI 측정용 다이폴안테나 교정의 측정 불확도)

  • Park, Jung-Kuy;Jeong, Dong-Chan;Cho, Jin-Young
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.2 s.117
    • /
    • pp.166-176
    • /
    • 2007
  • Measurement uncertainty assessment is very important in measurement and calibration. RRL provides antenna calibration services for EMI test. Reliability of EMI test depends on accurate antenna calibration. Antenna calibration results have to be accompanied with measurement uncertainty for its better reliability. In the late of 2005, CISPR issued the CISPR/A/644/C which describes the antenna calibration and measurement uncertainty. In this paper, on the basis of CISPR/A/644/C, we provide the measurement uncertainty values for dipole antenna calibration at the Calibration Test Site(CALTS) of Icheon. The antenna calibration method is 3-antenna height-scanning-averaging method, which measures the free-space antenna factor. We also considered all uncertainty sources that can affect measurement results during calibration.