• Title/Summary/Keyword: 불평형 전원전압

Search Result 86, Processing Time 0.032 seconds

Development of 3 level neutral-point-clamped rectifier for low voltage DC distribution (LVDC 배전용 3레밸 NPC 정류기 개발)

  • Kim, Ho-Sung;Ryu, Myung-Hyo;Baek, Ju-Won;Cho, Jin-Tae;Kim, Jae-Han
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.102-103
    • /
    • 2014
  • 본 논문에서는 ${\pm}750V$ LVDC 배전용 전원장치에 적합한 3레밸 NPC 정류기 시스템을 제안한다. 제안하는 정류기 시스템은 배선선로의 부하 불평형에 따른 NPC 정류기의 출력 전압 불평형 현상을 해결하기 위해서 출력전압 밸런스 알고리즘을 적용하였다. 제안하는 정류기 시스템은 50kVA 용량의 시제품의 실험을 통해서 성능을 검증하였다.

  • PDF

Research on the Protective Relay considers the Power System interconnected to small scale Distributed Generation. (소규모 분산전원의 계통연계를 고려한 보호계전에 관한 연구)

  • Ko, Yeon-Seong;Lee, Jong-Su;Lee, Bock-Ku;Shin, Myong-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.506-507
    • /
    • 2008
  • 소규모 풍력에너지, 연료전지 및 태양에너지 등의 신 재생에너지원들이 소규모 분산전원으로 도입되고 있다. 이로 인해, 수용가 측의 전원이 대규모 전력사업자로부터만 공급받던 시스템방식에서, 분산전원과 연계하여 동시에 사용하는 방식으로 바뀌고 있다. 이러한 분산전원이 계통에 도입될 경우 이로 인해 평상시 기존 계통의 보호방식에 미치는 영향의 경우는 상시전압변동, Flicker, 병해열로 인한 순시전압변동, 고조파, 불평형 등이 고려 될 수 있다. 또한 이러한 경우로 인해 보호계전기의 오동작도 초래 할 수 있다. 이에 본 논문에서는 태양광시스템을 분산전원으로 하는 연계 계통을 모델링하여 발생하는 파형에 대해 분석한다. 또한 디지털 보호계전기의 디지털 필터링 기법을 비교하여 빠른 연산 속도와 주파수 응답 특성을 가지는 알고리즘을 선정하고 모델링하여 모델링 된 디지털 필터로 분산전원 연계를 통해 얻어진 파형을 필터링 한다. 본 논문에서 분산전원의 계통 모의는 전력계통에 모의에 높은 신뢰성을 가지는 PSCAD/EMTDC를 기반으로 하였으며, 디지털 보호계전기의 디지털 필터 알고리즘 모델링은 MATLAB을 사용하였다.

  • PDF

The Study on Active Power Filter in Unbalanced Load (불평형부하에서의 능동필터에 관한 연구)

  • Choi, See-Young;Lee, Woo-Cheol;Hyun, Dong-Seok;Lee, Taeck-Kie
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1245-1247
    • /
    • 2000
  • 본 논문은 부하가 불평형인 경우에 능동필터의 제어를 수행하였다. 불평형 부하는 역상분 전류성분을 발생시키고 이것은 인버터의 직류단에 120Hz 전압리플을 발생시키게 된다. 그리고 인버터가 역상분까지 보상하게 되므로 전력용 반도체의 정격용량이 커져야 하는 문제점을 발생시킨다. 이런 문제를 해결하기 위해 동기좌표계에서 역상분 성분의 분리를 수행하였고, 이 성분을 전원측으로 흐르게 제어를 하였다. 이것의 타당성은 실험을 통해 검증되었다. 실험은 10kVA 정격의 병력형 능동필터로 구현되었다.

  • PDF

Design of the Robust Active Power Filter under the Unbalanced and Distorted Source Voltages in Three-phase Four-wire Systems (전원전압의 불평형 및 왜곡에 강인한 3상 4선식 전력용 능동 필터의 설계)

  • Min Joon-Ki;Kim HyoSung;Choi Jaeho;Kim Kyung-Hwan
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.9 no.5
    • /
    • pp.420-429
    • /
    • 2004
  • This paper proposes a novel current control strategy on active power filters using PQR instantaneous power theory which can compensate the line current harmonics and the neutral line current under the unbalanced and/or distorted source conditions in three-phase four-wire systems. The characteristics of the inverter ac filters are analyzed and a novel digital controller are proposed to overcome the inherent time delay problem in digital controllers with designed control gain in this paper. The proposed current control method is based on a sinusoidal PWM for fully-digital implementation compared with a conventional hysteresis PWM. PSiM simulation results verify the good performance of the proposed current control strategy on shunt type APFs.

Analysis on the Operation Characteristics of Induction Motor Operated by Voltage with Harmonics Components (고조파 성분이 포함된 전원에 의한 유도전동기의 동작특성 해석)

  • Kim, Jong-Gyeum;Park, Young-Jeen;Lee, Eun-Woong;Lee, Jong-Han;Lee, Dong-Ju
    • Proceedings of the KIEE Conference
    • /
    • 2005.10c
    • /
    • pp.63-66
    • /
    • 2005
  • 전원을 공급받아 동작하는 전기기기는 안정된 품질의 전원이 필수적이지만, 실제 부하에 인가되는 전압품질은 이상적인 성질이 아닌 약간의 왜형된 파형을 가지고 있다. 특히 단상과 3상을 함께 이용하는 3상 4선식 설비의 경우 부하 임피던스에 의해 전압의 크기가 변동하는 경우가 있으며 또한 선형 및 비선형 부하를 함께 사용하는 경우에 전압품질의 변화가 높은 편이다. 이와 같은 조건하에서 가장 많은 에너지를 이용하는 유도전동기가 고조파 성분이 포함된 전압불평형조건에서 어떤 동작특성을 나타내는 가를 시뮬레이션을 통해 분석하고자 한다.

  • PDF

Characteristics Analysis of Induction Motor by Operation of Non-linear Loads under the 3-Phase 4-Wire Grid System (3상 4선식에시 비선형 부하의 운전시 유도전동기의 특성 해석)

  • Kim, Jong-Gyeum;Park, Young-Jeen;Lee, Eun-Woong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.8
    • /
    • pp.54-62
    • /
    • 2006
  • Voltage unbalance will be generated by the load unbalance operation such as combination operation of single & three phase load and current unbalance will be more severe by the deteriorated voltage quality. Under the these unbalance conditions, all power electronic converters used in different types of electronic systems can increase harmonic disturbances by injecting harmonic currents directly into the feeder grid of three phase 4-wire. Harmonic current may cause torque to decrease. it may also overheat or become noisy and torque oscillation in the rotor can lead to mechanical resonance and vibration. This paper presents a scheme on the characteristics of induction motor under the combination of linear & non-linear loads at the three phase 4-wire power distribution system by the unbalance and harmonic components. It was able to confirm that the number of torque pulsation decreased and torque ripple values increased by the harmonics that reduction was difficult by five harmonics filters at additional driving time of single-phase non-linear load.

Planning for Operation of Dispersed Generation Systems considering Load Unbalance in Distribution Systems (배전계통에서 부하불평형을 고려한 분산형 전원의 운영 계획)

  • 이유정;유석구
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.5
    • /
    • pp.118-125
    • /
    • 2003
  • This paper presents a scheme for the placement of dispersed generator systems(DGs) based on load model in unbalanced systems. Groups of each individual load model consist of residential, industrial, commercial, official and agricultural load The main idea of solving fuzzy goal programming is to transform the original objective function and constraints into the equivalent multi-objectives functions with fuzzy sets to evaluate their imprecise nature for the criterion of power loss minimization, the number or total capacity of DGs and the bus voltage deviation, and then solve the problem using genetic algorithm The method proposed is applied to IEEE 13 bus unbalanced distribution systems to demonstrate its effectiveness.

Flywheel Energy Storage with Power factor Compensation (역률 보상기능을 갖는 플라이휠 에너지 저장장치)

  • Kwak C.H.;Jung S.O.
    • Proceedings of the KIPE Conference
    • /
    • 2006.06a
    • /
    • pp.285-287
    • /
    • 2006
  • 플라이휠 에너지 저장장치는 회전하는 물체에 에너지를 저장하고 이 에너지를 필요 시 기계적인 에너지를 변환하여 전기적 축전지이다. 플라이휠은 무정전전원장치의 직류측의 단자에서 전원을 받아 충전되며, 무정전전원장치의 입력 AC전압이 차단되어 UPS DC bus전압이 설정 값 이하로 떨어지면 저장 되어 있는 에너지를 전력변환 모듈에 의해 DC로 변환하여 UPS에 공급한다. 또한 전압 Sag, 전압의 불평형, 순간정전 및 고조파에 의한 정전에 대비하여 축전지와 플라이휠 에너지 저장장치를 조합하여 운용할 경우 축전지와 UPS의 DC BUS가 전기적으로 절연이 되어 개별 축전지 구성과 동일한 동작이 되도록 구성으로 축전지의 방전 횟수를 감소함으로써 축전지의 수명도 연장 할 수 있습니다.

  • PDF

Single phase Multi-level Inverter for Peak Power Compensation with High Speed Transit System (고속철도 피크전력보상을 위한 단상 멀티레벨 인버터)

  • Kwon, Kyoung-min;Jeon, Byeong-Jin;Lee, Eun-Kyu;Lee, Byeong-Gon;Choi, Jae-Ho
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.81-82
    • /
    • 2014
  • H-bridge 타입의 고압인버터는 낮은 DC링크 전압을 이용하여 높은 출력 AC전압을 얻을 수 있는 멀티레벨 인버터 토폴로지로서 다양한 분야에서 실증, 적용 되어왔다. 본 논문에서는 고속철도의 피크전력 보상을 위한 단상 H-bridge 멀티레벨 인버터를 사용한 PCS의 적용을 검토하였고, DC링크 전압을 각각의 배터리 전원을 사용함으로서 발생될 수 있는 배터리 불평형에 대한 PWM제어 알고리즘을 개발하였다. 제안된 알고리즘은 H-bridge타입에서 적용되고 있는 PWM제어방법 중 THD 특성에서 가장 우수한 PD방식을 배터리 상태에 따라 각 H-bridge에서 회전시켜 DC전압 불균형을 해결 할 수 있도록 구성하였다. 제안된 알고리즘은 PSIM을 사용하여 시뮬레이션을 수행함으로서 제안된 기법의 타당성을 검증하였다.

  • PDF

Hybrid-Type Active Power Filters for Compensating Harmonic Current and Unbalanced Source Voltages (고조파 전류와 불평형 전원전압 보상을 위한 복합형 능동전력 필터)

  • Lee, Ji-Myeong;Lee, Dong-Chun
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.5
    • /
    • pp.249-257
    • /
    • 2002
  • In this paper, a novel control scheme compensating source voltage unbalance and harmonic currents for the combined system of series active and shunt passive power filter is proposed, where no low/high-pass filters are used in deriving the reference voltage for compensation. The phase angle and the reference voltages compensating for harmonic current and unbalanced voltage are derived from the positive sequence component of the unbalanced voltage set, which is simply obtained by using digital all-pass filters. In order to remove the phase delay in generating the reference voltage for compensation, the reference of 5th and 7th harmonic components is predicted one-sampling ahead. The validity of the proposed scheme has been verified for 3[kVA] proto-type active power filter system.