• Title/Summary/Keyword: 불균질

Search Result 421, Processing Time 0.03 seconds

Renal Cell Carcinoma in a Pekingese Dog (페키니즈견에서 신장세포암종)

  • Lee Ki-chang;Jung Joo-hyun;Byeon Ye-eun;Oh Sun-kyung;Seo Eun-jung;Song Kyung-jin;Kweon Oh-kyeong;Yoon Jung-hee;Choi Min-cheol
    • Journal of Veterinary Clinics
    • /
    • v.22 no.2
    • /
    • pp.148-152
    • /
    • 2005
  • An intact female, 5-year-old, Pekingese, weighing 3.5kg with a history of a palpated abdominal mass was referred to Veterinary Medical Teaching Hospital, Seoul National University. In laboratory examination, there were no remarkable abnormalities. Radiographic findings included a left mid-abdominal mass with ill-defined margin, serosal detail loss of peritoneal space, non-uniform opacity of retroperitoneal space, and a radiopaque cystic calculus. On abdominal ultrasonography, a heterogeneous parenchymal mass with irregular contour in the left renal region was found. Computed tomographic findings showed a tumor embolus within the caudal vena cava and an invasion into mesentery, small bowel loops, spleen and pancreas around the large left renal mass. Unilateral nephroureterectomy was performed. Histopathologic examination of the resected mass confirmed the diagnosis of renal cell carcinoma. The dog died one day after surgery. Although ultrasonography could give diagnostic information about mass characteristics, computed tomography (CT) can provide key imaging features of mass characteristics.

Levels of Polycyclic Aromatic Hydrocarbons in Fish, Shellfish and their Processed Products (국내 유통 어패류 및 가공품 중 Polycyclic Aromatic Hydrocarbons 함량)

  • Hu, Soo-Jung;Kim, Mee-Hye;Oh, Nam-Su;Ha, Jin;Choi, Kwang-Sik;Kwon, Ki-Sung
    • Korean Journal of Food Science and Technology
    • /
    • v.37 no.6
    • /
    • pp.866-872
    • /
    • 2005
  • Cocentrations of PAHs [benzo(a)anthracene, chrysene, benzo(b)fluoranthene, benzo(k)fluoranthene, benzo(a)pyrene, dibenzo(a,h)anthracene, benzo(g,h.i)perylene, indeno(1,2,3-c,d)pyrene] in fish (n=120), shellfish(n=50) and their products (n=35) were estimated by saponification and extraction with n-hexane, clean-up on Sep-Pak Florisil Cartridges and HPLC/FLD. Overall recoveries for eight PAHs spiked into samples ranged from 90 to 106%. Mean level of benzo(a)anthracene, chrysene, benzo(b)fluoranthene, benzo(k)fluoranthene, benzo(a)pyrene, dibenzo(a,h)anthracene, benzo(g,h,i)perylene and indeno(1,2,3-c,d)pyrene were not detected, 0.01, 0.04, 0.07, 0.05, 0.004, 0.0008 and 0.06ng/g, respectively, similar to those reported by other countries.

'THE METHOD OF TBI FOR ACCURATE REPRODUCTION OF RADIATION FIELD AND PATIENT POSITION' (방사선 전신 조사 치료시 정확한 환자자세 및 조사야 재현을 위한 방법)

  • KWEON YOUNG-HO;LEE BYOUNG-GOO;WHANG WOONG-KU;KIM YOU-HYUN
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.7 no.1
    • /
    • pp.156-166
    • /
    • 1995
  • Total body irradiation (TBI) requires large radiation field and extended source to axis distance (SAD), therefore in needs large size treatment room and it needs compensators which components. Appropriate thickness beam spoiler should be used to raise skin dose. Treatment machine, photon energy, total dose, dose rate, dose fractionation, patient position, shield of normal tissues and organs were known to important parameters for TBI. TBI disturbes regular daily treatment schedule and significantly overloads Radiation on oncology departments and during the treatment session it requires accurate reproduction of radiation field and patient position. We were enable to TBI in small size treatment room and short SAD with parallel opposing lateral fields technique and achieved homogenious whole body dose distribution using pb compensators and controled lung dose by lung shield blocks. Drawing a patient shadow on the wall, we could shortened set up time and possible to accurate reproduction of radiation field and patient position.

  • PDF

Environmental Factors and Growth Properties of Sasa borealis (Hack.) Makino Community and Effect its Distribution on the Development of Lower Vegetation in Jirisan National Park (지리산국립공원 조릿대의 입지환경 및 생장특성 분석과 하층식생에 미치는 영향)

  • Park, Seok-Gon;Yi, Myung-Hoon;Yoon, Jung-Won;Sin, Hyun-Tak
    • Korean Journal of Environment and Ecology
    • /
    • v.26 no.1
    • /
    • pp.82-90
    • /
    • 2012
  • In this study, we investigated the environmental factors and growth characteristics of Sasa borealis community inside a temperate deciduous forest and reviewed its effect on the lower vegetation and natural regeneration. The S. borealis community in the Jungsan-ri region of Jirisan National Park was chosen as the study area, and the vegetation and the environmental factors were investigated. The dominance value, height and foliage layer thickness were investigated as the growth characteristics of S. borealis in the area. As the environmental factors, we investigated the photosynthesis photon flux density (PPFD) of the shrub and ground layers as well as the chemical characteristics of the soil. Additionally, we investigated the flora on the ground layer of the area as well as the number and height of woody plants. The result showed that the height and foliage layer thickness of the S. borealis was closely related to the light conditions but the distribution was not determined simply by the effect of the environment or vegetation of the particular area. This may be deeply related with the unique survival strategy of S. borealis, a vegetably propagated plant, that it can extensively distributed on a heterogeneous resources environment in a forest as multiple culm are interconnected with each other through the rhizomes. The dense dominance and great height of S. borealis reduced the plant species diversity in the ground layer by decreasing the PPFD on the ground surface.

P Wave Dispersion as a Predictor of Idiopathic Paroxysmal Atrial Fibrillation (특발성 발작성 심방세동 환자에서 P파 간격분산의 의의)

  • Hong, Gue-Ru;Kim, Woong;Park, Jong-Seon;Shin, Dong-Gu;Kim, Young-Jo;Shim, Bong-Sup
    • Journal of Yeungnam Medical Science
    • /
    • v.18 no.2
    • /
    • pp.267-276
    • /
    • 2001
  • Background: P wave dispersion(PWD) is defined as the difference between the maximum and minimal P wave duration in any of the 12 leads of the surface ECG. The prolongation of atrial conduction time and the inhomogeneous propagation of sinus impulse are known electrophysiologic features in patients with paroxysmal atrial fibrillation(PAF). The purpose of this study was to determine the role of P wave dispersion for the prediction of PAF and to evaluate the effectiveness of prophylactic antiarrhythmic therapy. Materials and Methods: The study population included 20 patients with a history of idiopathic PAF and 20 age and sex matched healthy control subjects. We measured the maximum P wave duration(P maximum) and P wave dispersion from 12 lead ECG. Results: P maximum and P dispersion in idiopathic PAF were significantly higher than normal control group($97.2{\pm}12$, $48.5{\pm}9$ msec vs, $76.5{\pm}11$, $21{\pm}8$ msec, respectively p<0.001, <0.001). After 12-month follow up period P maximum and P dispersion were significantly reduced than those of initial state($77.2{\pm}13$, $26.4{\pm}9$ msec vs. $97.2{\pm}12$, $48.5{\pm}9$ msec, respectively p<0.001,<0.001). Conclusion: P dispersion and P maximum were significantly different between patients with idiopathic PAF and healthy control group. Those are easily accessible, non-invasive simple electrocadiographic markers that could be used for the prediction and prognostic factors of idiopathic PAF.

  • PDF

Reinforcement, Thermal and Fire Retardant Improvement of Phenolic Composites by Surface Treatment of CFRP Chip (CFRP Chip 표면처리에 따른 페놀복합재료의 강화, 내열성 및 난연성 향상)

  • Kwon, Dong-Jun;Wang, Zuo-Jia;Gu, Ga-Young;Park, Joung-Man
    • Journal of Adhesion and Interface
    • /
    • v.13 no.2
    • /
    • pp.58-63
    • /
    • 2012
  • CFRP chip is the byproduct from carbon fiber reinforced plastic (CFRP) processing. CFRP chip is not simply a waste mainly composed of fine carbon fiber and epoxy resin. CFRP chip keeps matrix to maximize their reinforcing effect. To obtain a uniform length of carbon fiber in CFRP chip, chip was chopped ina mortar. CFRP chip should be purified to get better interface adhesion. Epoxy resin on the carbon fiber was removed by $H_2O_2$ surface etching treatment. Optimal dispersion and fabrication conditions of CFRP chip embedded in phenolic resin were determined by thermal stability for fire retardant applications. CFRP chip-phenolic composite exhibits better mechanical and thermal properties than neat phenolic resin. Surface condition of CFRP chip-phenolic composite was evaluated by static contact angle measurement. Contact angle of CFRP chip-phenolic composite was greater than neat phenolic due to heterogeneous condition of fine carbon fibers. From the evaluation for fire retardant (ASTM D635-06) test, thermal stability of CFRP chip-phenolic composite was found to be improved with higher concentration of CFRP chip.

Demonstration of Developed Numerical Procedure to Describe 3-dimensional Long-term Behavior of the Pleistocene Marine Foundations (Pleistocene 해저지반의 3차원 장기거동 해석을 위해 개발한 수치해석 기법의 입증)

  • Yun, Seong-Kyu
    • Journal of the Korean Geotechnical Society
    • /
    • v.36 no.7
    • /
    • pp.5-14
    • /
    • 2020
  • Kansai International Airport (KIX) was opened in September 1994. Although 26 years have passed since the completion of the first island, long-term settlement is still in progress. This settlement occurs in the Pleistocene layer. For it is not easy to determine the permeability of the Pleistocene sand layer because the thickness and the degree of fine content in the horizontal direction are constantly changing. In addition, it is also a difficult to predict the interactive behavior of the ground due to the construction of the second phase island adjacent to it. In order to solve this problem, a two-dimensional finite element analysis considering elasto-viscoplastic was performed to evaluate the long-term deformation, including the interactive behavior of the alternating Pleistocene foundation due to the construction of two adjacent reclaimed islands. In general, two-dimensional analysis can be used when a section can represent the entire sections. However, Kansai Airport is an artificial reclaimed island so two-dimensional analysis cannot solve the problem such as the stress deformation in the corners of the island. Additionally, the structure of the actual sub-ground through physical exploration is non-homogeneity and its thickness is also not constant. Therefore, there are limitations for the two-dimensional analysis to explain the phenomena. That is, three-dimensional analysis is strongly required. Due to these demands, the author extended the existing two-dimensional program capable of elasto-viscoplastic analysis to three-dimensional and completed the verification of the three-dimensional program developed through one-dimensional consolidation analysis. In order to demonstrate the validity of the developed 3D program that has been verified, an analysis is performed under the same analysis conditions as the existing research using a two-dimensional program. The effectiveness of the developed 3D numerical analysis program was demonstrated by comparing the analysis results with the 2D results and actual measurement data.

Characterization of a groundwater system by subsurface hydrogeological investigation data (지하공동굴착 시 수리지질조사 자료를 이용한 저장공동 심도의 지하수체계 특성 연구)

  • 조성일;김천수;김경수;송무영;전한석
    • The Journal of Engineering Geology
    • /
    • v.14 no.1
    • /
    • pp.93-104
    • /
    • 2004
  • This paper intended to assess the hydro-structure characteristics of volcanic rocks based on the hydrogeological data obtained from the underground storage cavern during construction. The variation of groundwater levels was periodically measured from the 28 surface monitoring holes(NX size) and the hydraulic pressures and injection rates were daily monitored from the water curtain holes(95 horizontal holes and 63 vertical holes). The hydraulic interference tests were performed in whole water curtain holes. The distribution patterns of hydraulic pressure are closely related to the dip angles of fracture intersected to the water curtain holes. Three domains can be grouped by the distribution of hydraulic pressures in the horizontal water curtain holes. The initial hydraulic pressures measured immediately after drilling of water crutain holes are high in ascending order of the cavern C-2, C-1, and C-3. The priliminary hydrochemical data also indicate that the portions of the deep groundwater composition is relatively great in the cavern C-3 area. Some of the horizontal water curtain holes in the cavern C-3 show a steady higher groundwater pressure with the composition of shallow groundwater indicating the outer boundary as constant hydraulic boundary. The water curtain holes in the cavern C-2 is characterized as low initial hydraulic pressure and less injection rates, suggesting poor hydraulic connectivity to a shallow groundwater system. The results of the study can help to understand a hydraulic compartment concept in a fracture hydro-geology and be utilized during the surface investigation for a groundwater system.

Correlation of Heavy Metal Concentrations between Total Digestion and Aqua Regia Digestion for Sediments from Yeongsan and Seomjin Watersheds (완전분해와 전분해 방법에 의한 영산강.섬진강수계 퇴적물의 중금속농도 상관관계)

  • Oh, Da-Yeon;Choi, Kyoung-Kyoon;Huh, In-Ae;Hwang, In-Seong;Kim, Young-Hoon;Hur, Jin;Shin, Hyun-Sang;Oh, Jeong-Eun;Shin, Won-Sik;Park, Jeong-Hun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.1
    • /
    • pp.32-38
    • /
    • 2011
  • In this study, the correlations of concentrations in sediment heavy metals between two pretreatment methods, total digestion and aqua regia digestion, have been investigated. Total 43 samples had been collected from streams and lakes in Yeongsan and Seomjin watersheds. They were decomposed in two pretreatment methods and five metal components (Cd, Cr, Ni, Pb, Zn) were analyzed. Overall average concentrations of heavy metals were Zn>Cr>Pb>Ni>Cd in the order. The concentrations of aqua regia digestion were 35.0% (Cd), 53.8% (Cr), 66.2% (Ni), 64.4% (Pb) and 76.4% (Zn) of the concentrations of total digestion and heavy metal concentrations of total digestion were higher. Heavy metal concentrations in sediments from lakes were higher than those from streams. The correlation equations between the concentrations of total digestion and aqua regia digestion were obtained. The concentrations of Zn and Ni, which showed strong linear correlations, increased in aqua regia digestion as the concentration in total digestion increased. The linear correlation coefficients between two digestion methods for most analyzed metals were above the average correlation. However, these results can be applied with limitations due to heterogeneity of sediments.

Estimation of Groundwater Level Fluctuation of the Crystalline site Using Time Series Analyses in South Korea (시계열분석을 이용한 결정질암 지역의 지하수위 변동 평가)

  • Lee, Jeong-Hwan;Jung, Haeryong;Lee, Eunyong;Kim, Sujeong
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.11 no.3
    • /
    • pp.179-192
    • /
    • 2013
  • This study is characterized the groundwater flow pattern near crystalline site of Yangbook-Myeon, Gyeong-ju City, South Korea. From the time series analyses, groundwater level could be classified into 4 types reflecting the hydrogeological characteristics and rainfall pattern. The type I (DB1-1, DB1-2) may be directly influenced by rainfall pattern. The type II (DB1-3, DB1-7, KB-1, KB-2, KB-3, KB-7, KB-14, KB-15) may be influenced by rainfall event as well as groundwater flow through water-conducting features. The type III (DB-5, DB1-6, DB2-2, KB-10, KB-11, KB-13) may be predominantly happens in the crystaline rock mass, groundwater in this type flows through the minor fracture networks rather than direct effect of rainfall event. The type IV (DB1-8, KB-9) may be influenced by irregular variation of the groundwater level due to anisotropy and heterogeneity of crystalline rock.