• Title/Summary/Keyword: 분할조사간 편차

Search Result 12, Processing Time 0.04 seconds

Long haul transmission link using a optimized circulating loop for optical wavelength division multiplexing signals (최적화된 반복루프를 이용한 파장분할다중화 광신호 장거리 전송)

  • Choi, Bo-Hun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.7
    • /
    • pp.1757-1763
    • /
    • 2014
  • Optical wavelength division multiplexing signals of eight non-return-to-zero 10 Gb/s channels were transmitted on the long-haul link up to 720 km. The link span was composed of 80 km single mode fiber, dispersion compensation fiber for complete compensation, and EDFAs. A circulating loop method was applied to the link experiment and the loop was optimized for the transmission link. Wavelength-dependent gain variation of EDFA was compensated using EDFAs of opposite gain slopes without expensive gain flattening filters. Average OSNR was aggravated to 22 dB and the worst OSNR channel variation was 9.7 dB after the transmission. It was confirmed by analyzing optical spectra that this OSNR variation was mainly caused by the hole burning effect of EDFA.

Isocenter Reproducibility with Mask Fixation System in Stereotactic Radiosurgery (정위 마스크 시스템을 사용한 방사선수술시 회전중심점의 재현성)

  • 이동준;손문준;이기택;최찬영;황금철;황충진
    • Progress in Medical Physics
    • /
    • v.13 no.3
    • /
    • pp.135-138
    • /
    • 2002
  • Fractionated stereotactic radiosurguy (FSRS) requires precise and reproducible patient set up. For these reasons non-invasive mask fixation methods have been used in Linac based FSRS. In this study, we measured and assessed the isocenter reproducibility using a commercial head mask fixation system based on thermoplastic materials. For the verification and the measurement of isocenter deviation a special acrylic brain phantom was designed. The designed phantom has 22 vertical rods and each rod has different lengths. At the end of the 8 rods, the monochromic film is attached and irradiated due to planned target position. Deviations of isocenter were measured separately for each direction. The mean deviation showed 0.4 mm in longitudinal direction, 0.1 mm in the lateral direction, 0.1 mm in the anterior-posterior direction of the treatment couch. The data demonstrates the high accuracy and reproducibility. This study reinforces previous literature published.

  • PDF

Study on Applicability of Stereophotogrammetry to Rock Joint Survey (입체사진측량기법의 암반절리조사에 대한 적용성 연구)

  • Han, Jeong-Hun;Song, Jae-Joon
    • Tunnel and Underground Space
    • /
    • v.17 no.2 s.67
    • /
    • pp.139-151
    • /
    • 2007
  • Stereophotogrammetry is a method to extract information of an interested area by constructing a stereo-image from two or more photos. In this study, the stereophotogrammetry was adopted to obtain the joint orientation and trace length from a sampling window and its measurements were compared with the result by a clinocompass and measuring tape to evaluate the applicability of the stereophotogrammetry to rock joint survey. A commercial stereophotogrammetry program, ShapeMetriX 3D, was used for this purpose. Firstly, the accuracy of the measuring method using ShpaeMetrix 3D was evaluated by a model test. Secondly, joint orientations on a rock slope and tunnel were obtained by using ShapeMetriX 3D and compared with the measurement by a clinocompass. Finally. the effect of base-depth ratio in photographing was evaluated by comparing images with various base-depth ratios, and the usefulness of closed-up photographing on a rock exposure to increase the measurement accuracy was tested. The dip and dip direction of each model plane obtained by ShapeMetriX 3D showed an error ranged between $-5^{\circ}\;and\; 5^{\circ}$ on the basis of the results by the measuring tape. Base-depth ratio proved not to influence the analysis result by ShapeMetriX 3D if all the images were taken without any hidden area. The close-up photographing turned out useful to obtain the detailed images and therefore precise result when ShapeMetriX 3D was adopted.

Study on the Characteristics of Far Infrared Ray Drying for Rough Rice(III) - Performance test of far infrared ray dryer - (벼의 원적외선 건조특성에 관한 연구(III) 원적외선 건조기 성능시험)

  • 김유호;조영길;조광환;이선호;김영민;한충수;금동혁;한종규
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2003.07a
    • /
    • pp.213-219
    • /
    • 2003
  • 본 연구에서는 새로운 개념의 건조방법을 연구하여 곡물건조의 변화를 도모하고자 원적외선ㆍ열풍 복합열을 이용한 곡물건조기를 개발하게 되었다. 그 결과를 요약하면 다음과 같다. 가. 방사체길이가 1,680mm일 때 보다 1,470mm일 때가 방사체 표면온도가 높게 나타났고, 안정적인 것으로 나타났다. 열풍온도를 5$0^{\circ}C$로 설정했을 때 방사체의 표면온도분포는 280-29$0^{\circ}C$을 유지하였고, 6$0^{\circ}C$일 때는 30$0^{\circ}C$ 부근에서 유지되는 것을 확인할 수 있었다. 두 조건 모두에서 온도편차는 크게 나타나지 않았으므로 균일 건조가 이루어지는 것을 의미하며, 곡물의 품질저하에 영향을 미치지 않는 것으로 판단된다. 나. 열풍온도 5$0^{\circ}C$, 조사거리 125mm, 방사체 길이 1,470mm에서 방사체 길이방향으로 위치에 따라서 온도편차를 측정했을 때 버너를 기점으로 해서 근거리에서부터 원거리까지 균등 분할하여 5점의 온도를 측정하여 그 변화곡선을 분석한 결과 위치 3에서 온도가 높았고, 계속해서 위치 4, 5, 2, 1순으로 나타났다. 버너의 근거리에서보다 원거리에서 온도가 높게 나타난 것은 원적외선방사체를 통과하는 열풍이 빠져나가도록 되어있는 열풍유동관이 버너 원거리에 위치하고 있어 버너에 불꽃이 점화되면서 열풍이 방사체 끝쪽으로 유동되기 때문이다. 다. 건조실 수직면 길이방향의 온도는 열풍공기가 열풍실에서 유입되는 하단부이 온도가 높게 나타났고, 버너쪽과 송풍기쪽의 온도차는 나타나지 않아 온도분포의 좌우 대칭이 잘 되어 균일 건조가 되는 것으로 판단된다 이러한 현상은 건조실의 수평면에 대해서도 같은 현상이 나타났다. 라. 바닥면에서 상부로 올라갈수록 낮은 온도분포를 나타내고 있는 것은 상부에는 외부공기가 유입되면서 온도가 떨어지는 반면 하부에는 외부공기 유입이 적기 때문으로 사료된다. 또한 열풍실의 길이방향 위치별 온도 분포에서도 같은 현상으로 나타났고, 버너쪽과 송풍기쪽의 온도편차는 나타나지 않아 균일 건조를 기대할 수 있다. 마. 열풍온도를 45$^{\circ}C$로 설정하고 조사거리와 방사체 길이를 각각 119, 1,470mm로 하여 벼의 건조성능시험을 열풍건조기(대비구)와 비교시험 결과 시험구에서 건감률, 건조소요에너지가 각각 0.58%(w.b.), 470kcal/kg - water로 대비구보다 각각 건감율은 23% 높았고, 건조소요에너지는 2%의 절감되었다. 바. 건조기에서 발생되는 소음은 버너쪽 근처에서는 대비구 94.12㏈의 87%에 불과하였으나, 거리가 멀어질수록 차이는 크지 않았다. 이것은 버너에서 멀어질수록 외부적인 요인이 소음에 영향을 미쳤기 때문인 것으로 생각된다. 사. 시작기와 대비구간의 경제성에서 시작기의 구입가격이 20% 비싸기 때문에 시간당 고정비가 높았으나, 건조성능이 우수하여 건조비용이 69,350원/톤으로 대비구보다 14% 절감되는 것으로 나타났다.

  • PDF

Plus-size여성 체형을 위한 재킷원형 개발 및 면 분할에 따른 시각적 효과에 관한 연구

  • 정동림;김애린
    • Proceedings of the Korea Society of Costume Conference
    • /
    • 2003.05a
    • /
    • pp.34-34
    • /
    • 2003
  • 본 연구는 체형의 특성이 현저히 나타나는 40~50대의 Plus-size 여성을 대상으로 체형의 특징이 고려된 치수체계에 대해 맞음새가 우수한 재킷을 개발하고, 이 원형을 토대로 하여 체형의 단점을 보완할 시각적 효과를 연구하기 위해 Plus-size에 해당하는 여성을 선정하여 수트(suit)를 제작한 후 착의 평가하여 Plus-size에 적합한 수트를 제안하는데 목적을 두고 있다. 결과를 요약하면 다음과 같다. 1. Plus-size 여성의 착용실태를 파악하기 위해 실시한 착용실태 조사는 판매자의 측면의 심층면접과 소비자 측면의 착장조사로 구분하여 조사하고 분석하였다. 착용실태조사 결과, Plus-size 여성은 의복구매시 맞음새와 편안함을 중시하고 상완부와 어깨의 두께, 가슴둘레와 복부의 비만등의 체형단점을 갖게 되므로 판매자측에서는 의복제도 시에 등품, 앞품, 상완부, 복부의 여유분을 고려하고 있었다. 시각적 효과로는 세미피트 스타일의 프린세스 라인과 허리선+20, 30cm의 재킷길이, 그리고 테일러드 칼라, 스테인 칼라, 라운드 네크라인이 판매자과 소비자의 양측면에서 선호되고 있었다. 2. Plus-size 여성의 체형에 맞음새가 우수한 재킷원형을 개발하기 위해 Plus-size 여성복의 재킷 원형 중 4종의 기존원형을 선정하고, 착의 피험자 3인을 대상으로 3차에 걸친 착의실험을 통해 연구 원형을 개발하고 평가단을 구성해 객관적인 평가 33문항에 대한 외관 관능검사를 실시하였다. 1) 가슴둘레 여유분을 8~9cm, 허리둘레 여유분을 6~7cm, 엉덩이둘레 여유분을 6~8cm로 적용하여 맞음새를 향상시켜 날씬해 보이는 효과를 높였다. 2) 진동깊이 계산식은 (B/10+10.5)+2cm 적용하고, 진동두께 계산식은 (B/8-1.5)+2cm를 적용함으로써 진동깊이와 진동두께의 편차가 작아짐으로 인해 소매부위와 진동부위의 맞음새를 향상시켰다. 3) 가슴둘레의 증가에 따라 등길이에 앞길이 치수를 증가시키는 계산식을 설정하여 앞가슴둘레의 맞음새를 향상시켰다. 4) Plus-size여성의 경우 허리부분의 신체적합성을 높이기 위하여 사이드 판넬(side panel)의 재킷원형으로 하였다. 앞 허리와 배 부분의 지방 침착이 크므로 앞 허리둘레 다아트 폭과 앞판 사이드 판넬(side panel) 솔기 다아트 폭을 작게 설정하고, 뒤판 사이드 판넬 솔기 폭을 크게 설정하였다. 5) 어깨끝점 사이길이는 다른 부위의 체지방 침착과 같이 비례적으로 증가하지 않으므로 표준체형에 비해 좁게 설정하였다.

  • PDF

Discharge estimation using surface velocity and index velocity method (표면유속과 지표유속법을 이용한 유량산정)

  • Lee, Sin Jae;Choi, Hong Yoon;Lee, Dae Young
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2018.05a
    • /
    • pp.273-273
    • /
    • 2018
  • 하천유량을 산정하는 전통적인 방법은 수위-유량관계(stage-discharge relation)를 이용하는 것이며, 최근에는 하천특성에 따라 연속적으로 유속을 직접 측정하고 지표유속법(index velocity method) 또는 유속분포법(velocity profile method)을 이용하는 방법도 적용되고 있다. 연속으로 유속을 측정하는 방법에는 전자파 또는 영상이미지를 이용하여 표면유속을 측정하는 방법과 수중에 초음파 유속계를 설치하여 수중의 유속을 측정하는 방법이 있으며, 국내에서는 초음파 유속계를 이용하는 방법이 주로 활용되고 있다. 본 연구에서는 전자파표면유속계(MU2720)로 측정된 표면유속과 지표유속법을 이용하여 하천유량 산정방법을 검토하였다. 본 연구는 홍천강의 홍천군(반곡교)와 홍천군(홍천교), 한탄강의 철원군(한탄대교) 수위관측소에서 2016년도에 전자파표면유속계로 측정된 43개의 자료(평균유속 0.61~2.56m/s)를 이용하였다. 전자파표면유속계에 의한 유속측정은 한 지점에 고정하여 측정하지 않고 여러 개의 측선을 분할하여 표면유속을 측정하였으며, 단면 평균유속(Vm)과 가장 상관성이 높은 측선(지점)의 유속을 지표유속으로 하여 지표유속(vi)과 평균유속과의 관계식을 작성하고, 이를 통해 유량을 산정하였다. 여기서 평균유속은 전자파표면유속계로 측정한 유속을 이용하여 산정한 값이다. 그 결과 지표유속과 평균유속관계식의 결정계수($R^2$)는 0.9874~0.9976이었으며, 측정 평균유속과 지표유속관계식으로 산정된 평균유속과의 평균 편차율은 2.26~3.80%로 표면유속과 지표유속법을 이용한 유량산정 방법의 적정성을 확인할 수 있었다. 따라서 현재 국내에서 자동유량측정시스템에 초음파유속계만 상용화되고 있으나 향후에는 하천특성에 따라 전자파표면유속계를 이용하는 방법도 고려해 볼 필요가 있을 것으로 판단된다.

  • PDF

Application of Fractal Dimension on Consistent Calculation of Coastline Length - Focused on Jeju Island (일관된 해안선 길이 산출을 위한 프랙탈 차원 적용 방안 연구 - 제주도를 중심으로 -)

  • Woo, Hee Sook;Kwon, Kwang Seok;Kim, Byung Guk;Cho, Seck Hyun
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.24 no.4
    • /
    • pp.83-88
    • /
    • 2016
  • The use of consistent coastlines is an important element for the systematic management of maritime boundaries and the interests of local governments. The Hydrographic and Oceanographic Agency conducted a preliminary survey for consistent coastline production, since 2001. As a result, the length of coastline was different by year. Because of the lack of systematic management, the use of incorrect data, etc. We also changed the coastline on the sea chart to show on a digital map for realization of terrain expression method. However, there was a variation in shoreline length due to various surveying techniques and shoreline extraction methods. In this paper, the characteristics of Jeju-do coastline were analysed by using a modified divider method of fractal dimension. The accuracy of the vectorization was determined by converting the actual distance in the Public Survey Amendment for proper divider use. With 1:5,000 and 1:25,000 digital maps of Jeju-si and Seogwipo-si each fractal dimensions were calculated. Jeju-si=1.14 and Seogwipo-si=1.12 in 1: 5,000. Jeju-si=1.13 and Seogwipo-si=1.10 in 1: 25,000. Calculated fractal dimension were correlated to data from digital maps. It was considered that complexity and scale of coastlines affected. In the future coastline length statistics and minimum ratio of calculated coastline length to original length need to be determined for consistency of coastline length statistics.

Computer Assisted EPID Analysis of Breast Intrafractional and Interfractional Positioning Error (유방암 방사선치료에 있어 치료도중 및 분할치료 간 위치오차에 대한 전자포탈영상의 컴퓨터를 이용한 자동 분석)

  • Sohn Jason W.;Mansur David B.;Monroe James I.;Drzymala Robert E.;Jin Ho-Sang;Suh Tae-Suk;Dempsey James F.;Klein Eric E.
    • Progress in Medical Physics
    • /
    • v.17 no.1
    • /
    • pp.24-31
    • /
    • 2006
  • Automated analysis software was developed to measure the magnitude of the intrafractional and interfractional errors during breast radiation treatments. Error analysis results are important for determining suitable planning target volumes (PTV) prior to Implementing breast-conserving 3-D conformal radiation treatment (CRT). The electrical portal imaging device (EPID) used for this study was a Portal Vision LC250 liquid-filled ionization detector (fast frame-averaging mode, 1.4 frames per second, 256X256 pixels). Twelve patients were imaged for a minimum of 7 treatment days. During each treatment day, an average of 8 to 9 images per field were acquired (dose rate of 400 MU/minute). We developed automated image analysis software to quantitatively analyze 2,931 images (encompassing 720 measurements). Standard deviations ($\sigma$) of intrafractional (breathing motion) and intefractional (setup uncertainty) errors were calculated. The PTV margin to include the clinical target volume (CTV) with 95% confidence level was calculated as $2\;(1.96\;{\sigma})$. To compensate for intra-fractional error (mainly due to breathing motion) the required PTV margin ranged from 2 mm to 4 mm. However, PTV margins compensating for intefractional error ranged from 7 mm to 31 mm. The total average error observed for 12 patients was 17 mm. The intefractional setup error ranged from 2 to 15 times larger than intrafractional errors associated with breathing motion. Prior to 3-D conformal radiation treatment or IMRT breast treatment, the magnitude of setup errors must be measured and properly incorporated into the PTV. To reduce large PTVs for breast IMRT or 3-D CRT, an image-guided system would be extremely valuable, if not required. EPID systems should incorporate automated analysis software as described in this report to process and take advantage of the large numbers of EPID images available for error analysis which will help Individual clinics arrive at an appropriate PTV for their practice. Such systems can also provide valuable patient monitoring information with minimal effort.

  • PDF

Image Contrast Enhancement Technique for Local Dimming Backlight of Small-sized Mobile Display (소형 모바일 디스플레이의 Local Dimming 백라이트를 위한 영상 컨트라스트 향상 기법)

  • Chung, Jin-Young;Yun, Ki-Bang;Kim, Ki-Doo
    • 전자공학회논문지 IE
    • /
    • v.46 no.4
    • /
    • pp.57-65
    • /
    • 2009
  • This paper presents the image contrast enhancement technique suitable for local dimming backlight of small-sized mobile display while achieving the reduction of the power consumption. In addition to the large-sized TFT-LCD, small-sized one has adopted LED for backlight. Since, conventionally, LED was mounted on the side edge of a display panel, global dimming method has been widely used. However, recently, new advanced method of local dimming by placing the LED to the backside of the display panel and it raised the necessity of sub-blocked processing after partitioning the target image. When the sub-blocked image has low brightness, the supply current of a backlight LED is reduced, which gives both enhancement of contrast ratio and power consumption reduction. In this paper, we propose simple and improved image enhancement algorithm suitable for the small-sized mobile display. After partitioning the input image by equal sized blocks and analyzing the pixel information in each block, we realize the primary contrast enhancement by independently processing the sub-blocks using the information such as histogram, mean, and standard deviation values of luminance(Y) component. And then resulting information is transferred to each backlight control unit for local dimming to realize the secondary contrast enhancement as well as reduction of power consumption.

Development of Gated Myocardial SPECT Analysis Software and Evaluation of Left Ventricular Contraction Function (게이트 심근 SPECT 분석 소프트웨어의 개발과 좌심실 수축 기능 평가)

  • Lee, Byeong-Il;Lee, Dong-Soo;Lee, Jae-Sung;Chung, June-Key;Lee, Myung-Chul;Choi, Heung-Kook
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.2
    • /
    • pp.73-82
    • /
    • 2003
  • Objectives: A new software (Cardiac SPECT Analyzer: CSA) was developed for quantification of volumes and election fraction on gated myocardial SPECT. Volumes and ejection fraction by CSA were validated by comparing with those quantified by Quantitative Gated SPECT (QGS) software. Materials and Methods: Gated myocardial SPECT was peformed in 40 patients with ejection fraction from 15% to 85%. In 26 patients, gated myocardial SPECT was acquired again with the patients in situ. A cylinder model was used to eliminate noise semi-automatically and profile data was extracted using Gaussian fitting after smoothing. The boundary points of endo- and epicardium were found using an iterative learning algorithm. Enddiastolic (EDV) and endsystolic volumes (ESV) and election fraction (EF) were calculated. These values were compared with those calculated by QGS and the same gated SPECT data was repeatedly quantified by CSA and variation of the values on sequential measurements of the same patients on the repeated acquisition. Results: From the 40 patient data, EF, EDV and ESV by CSA were correlated with those by QGS with the correlation coefficients of 0.97, 0.92, 0.96. Two standard deviation (SD) of EF on Bland Altman plot was 10.1%. Repeated measurements of EF, EDV, and ESV by CSA were correlated with each other with the coefficients of 0.96, 0.99, and 0.99 for EF, EDV and ESV respectively. On repeated acquisition, reproducibility was also excellent with correlation coefficients of 0.89, 0.97, 0.98, and coefficient of variation of 8.2%, 5.4mL, 8.5mL and 2SD of 10.6%, 21.2mL, and 16.4mL on Bland Altman plot for EF, EDV and ESV. Conclusion: We developed the software of CSA for quantification of volumes and ejection fraction on gated myocardial SPECT. Volumes and ejection fraction quantified using this software was found valid for its correctness and precision.