• Title/Summary/Keyword: 분극전위

Search Result 146, Processing Time 0.024 seconds

Electrochemical Analysis of the Electrodeposition of Platinum Nanoparticles (백금 나노입자 전착의 전기화학적 분석)

  • Lee, Hae-Min;Cho, Sung-Woon;Kim, Jun-Hyun;Kim, Chang-Koo
    • Korean Chemical Engineering Research
    • /
    • v.53 no.5
    • /
    • pp.540-544
    • /
    • 2015
  • A bath for electrodeposition of platinum nanoparitcles on low-cost graphite substrates was developed to attach nanoparticles directly onto a substrate, and electrochemical characteristics of the electrodeposition of platinum nanoparticles were investigated. The reaction mechanism was examined by the analysis of polarization behavior. Cyclic voltammetry measurements revealed that the elecrodeposition of platinum nanoparticles was limited by mass transfer. The chronoamperometric study showed an instantaneous nucleation mechanism during the electrodeposition of platinum nanoparticles on graphite. Because graphite is much cheaper than other carbon-based substrates, the electrodeposition of platinum nanoparticles on the graphite is expected to have useful applications.

An Electrochemical Evaluation on the Corrosion Resistance of a Al Alloy (주조용 Al합금의 내식성에 관한 전기화학적 평가)

  • Youn Dae-Hyun;Lee Myung-Hoon;Kim Ki-Joon;Moon Kyung-Man
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.29 no.5
    • /
    • pp.495-501
    • /
    • 2005
  • Al is a active metal that owes its resistance to a thin, protective, barrier oxide surface layer, which is stable in air and neutral aqueous solution. Thus Al alloys are widely used in architectural trim. cold & hot-water storage vessels and piping. However Al and most of its alloy may corrode with some forms such as pitting corrosion, intergranular corrosion and galvanic corrosion in the case of exposure to various industrial and marine atmosphere. Therefore a correct evaluation of corrosion resistance for their Al and Al alloys may be more important in a economical point of view. In this study. a relative evaluation of corrosion resistance for three kinds of Al alloys such as ALDC2, ALDC3, and ALDC8 series was carried out with electrochemical method. There is a tendency that corrosion potential is shifted to positive or negative direction by alloying components regardless of corrosion resistance. Moreover the data of corrosion properties obtained from cathodic Polarization curve, cyclic voltammogram and AC. DC impedance respectively showed a good correspondence each other against the corrosion resistance but variation of corrosion potential. passivity current density of anodic polarization curve and corrosion current density by Tafel extrapolation and Stern-Geary method didn't correspond with not only each other but also considerably the data of corrosion properties discussed above. Therefore it is suggested that an optimum electrochemical evaluation for corrosion resistance of Al alloy is to calculate the diffusion limiting current density of cathodic polarization curve, impedance of AC or DC and polarization resistance of cyclic voltammogram.

Corrosion Behaviors of TiC Ceramic Particulate Reinforced Steel Composites Fabricated by Liquid Pressing Infiltration Process in Salt Water Environment (용융가압함침공정으로 제조된 TiC 세라믹 입자 강화 철강복합재의 염수환경에서의 부식 특성)

  • Lee, Yeong-Hwan;Ko, Seongmin;Shin, Sangmin;Cho, Seungchan;Kim, Yangdo;Kim, Junghwan;Lee, Sang-Kwan;Lee, Sang-Bok
    • Composites Research
    • /
    • v.33 no.5
    • /
    • pp.251-255
    • /
    • 2020
  • In this study, TiC ceramic particulate reinforced steel composites was fabricated using a liquid pressing infiltration process. Studies were conducted on microstructure analysis and basic physical properties such as hardness and corrosion characteristics in salt water environment for comparison with commercial nodular cast iron. As a result of comparison of corrosion characteristics in a salt water environment, both corrosion potential and corrosion current density were lower than that of ductile graphite cast iron. The lower calculated corrosion rate confirms that the TiC-Fe metal composite has superior corrosion resistance than the cast iron.

An Electrochemical Evaluation on Corrosion Properties of Welding Zone of Stainless Steel by GTAW (GTAW에 의한 스테인리스강 용접부위의 부식특성에 관한 전기화학적 평가)

  • Moon, Kyung-Man;Lee, Kyu-Hwan;Kim, Jin-Gyeong
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.34 no.5
    • /
    • pp.678-685
    • /
    • 2010
  • GTAW was carried out to the austenitic 304(STS 304) and 22 APU stainless steels. In this case, difference of the corrosion characteristics of welded zone with STS 304 and 22APU mentioned above was investigated with electrochemical methods. Vickers hardness of weld metal in case of STS 304 (Hv-250) showed a relatively higher value than this of 22 APU(Hv-217). The corrosion current densities of weld metal of 22APU and heat affected zone of STS 304 were observed at the highest value compared to those of other welding zone respectively. This is probably because chromium depletion field due to chromium carbide formed to weld metal of 22APU and to heat affected zone of STS 304 can preferentially easily be corroded with more active anode than other fields. Consequently it is thought that application of the other welding methods like as laser welding or using of the optimum filler metals is necessary to improve the corrosion resistance of welding parts of these steels.

Ag 나노입자에 의한 Semi-Polar InGaN/GaN LED의 광효율 증가

  • Lee, Gyeong-Su;O, Gyu-Jin;Kim, Eun-Gyu
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.373-373
    • /
    • 2013
  • 높은 효율의 InGaN/GaN 전광소자는 현대 조명 산업에 필수적인 역할을 하고 있다. 그러나 전광소자의 효율을 높이는 데에는 여러가지 한계들이 있다. 예를 들면 높은 전류에서의 효율저하, GaN 의 전위결함에 의한 비발광 재결합의 발생 등이 있다. 이러한 한계를 극복하고자 InGaN/GaN 전광소자의 효율을 높이기 위해 사파이어 기판의 표면을 거칠게 바꾸는 방법, 무분극 전광소자, 표면 플라즈몬 등 여러가지 많은 방법들이 개발되고 있다. c-plane InGaN/GaN LED 기반의 표면 플라즈몬 실험은 많은 연구가 수행되고 있으나, m-plane InGaN/GaN LED 기반의 표면 플라즈몬은 아직 연구가 진행되지 않았다. 본 실험의 목적은 표면 플라즈몬 효과를 이용하여 semi-polar InGaN/GaN LED의 광효율을 개선하는 것이다. 유기금속화학 증착 장비로 m-plane sapphire위에 $6{\mu}m$ 의 GaN 버퍼층을 증착하고 표면의 평탄화를 위해 $2{\mu}m$의 n-GaN을 증착하였다. 그 위에 3개의 다중양자우물 층을 증착하였고, 10 nm의 도핑이 되지않은 GaN를 증착하였다. 표면 플라즈몬 현상을 일으키기 위해 Ag박막을 10, 15, 20 nm 증착하여 급속 열처리 방법으로 $300^{\circ}C$에서 20분 열처리 하였다. 형성된 나노입자를 측정하기 위해 주사전자현미경으로 표면을 분석하였다. 표면플라즈몬에 의한 InGaN/GaN 광 세기를 측정하고자 여기 파장이 385 nm인 photoluminescence (PL) 를 사용하였다. 또한 내부양자효과의 증가를 확인하기 위해 PL을 이용하여 온도를 10~300 K까지 20 K 간격으로 광세기를 측정하였다. 향상된 내부 양자효과가 표면 플라즈몬에 의한 것임을 증명하기 위해 time-resolved PL을 이용하여 운반자 수명시간을 구하였다.

  • PDF

Manufacture of magnetite (Fe3O4) electrode and its electrochemical properties (마그네타이트 (Fe3O4) 전극의 제조와 전기화학 특성)

  • Kim, Myong-Jin;Kim, Dong Jin;Kim, Hong Pyo
    • Corrosion Science and Technology
    • /
    • v.14 no.1
    • /
    • pp.19-24
    • /
    • 2015
  • Flow Accelerated Corrosion (FAC) causes unexpected accidents in a secondary side of a nuclear power plant. The secondary side pipes are mainly carbon steel tubes that have a protective magnetite ($Fe_3O_4$) layer on the inner surface. The stability of the protective magnetite layer depends on the parameters related to the FAC phenomena such as pH, temperature, flow rate, surface roughness etc. The dissolution of magnetite is basically the electrochemical reaction, but the most of the experiments of magnetite dissolution were carried out thermodynamically to determine the solubility of magnetite. The knowledge of the electrochemical properties of magnetite is required to understand the dissolution process of magnetite. This paper reviews the manufacture of the magnetite ($Fe_3O_4$) electrode, and summaries the electrochemical properties of the magnetite.

Effect of Annealing Heat Treatment to Corrosion Resistance of a Copper (구리의 내식성에 미치는 어닐링 열처리의 영향)

  • Kim Jin-Kyung;Moon Kyung-Man;Lee Jin-Kyu
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.29 no.6
    • /
    • pp.654-661
    • /
    • 2005
  • Copper is a well known alloying element that is used to improve the resistance to general corrosion of stainless steel And also Cu cation have the anti-fouling effect to inhibit adhesion of the marine algae and shellfish to the surface of heat exchanger cooling pipe or outside wall of the ship, Therefore there are some anti-fouling methods such as anti-fouling Paint mixed with copper oxide or MGPS(Marine Growth Preventing System) by using Cu cation dissolved to the sea wather solution. Cu cation can be dissolved spontaneously by galvanic current due to Potential difference between Cu and cooling pipe of heat exchanger with Ti material, which may be one of the anti-fouling designs. In this study the effect of annealing heat treatment to galvanic current and Polarization behavior was investigated with a electrochemical points of view such as measurement of corrosion Potential, anodic polarization curve. cyclic voltammetric curve, galvanic current etc The grain size of the surface in annealed at $700^{\circ}C$ was the smallest than that of other annealing temperatures. and also the corrosion Potential showed more positive potential than other annealing temperatures. The galvanic current between Ti and Cu with annealed at $700^{\circ}C$ was the largest value in the case of static condition. However its value in the case of flow condition was the smallest than the other temperatures. Therefore in order to increase anti-fouling effect by Cu cation, the optimum annealing temperature in static condition of sea water is $700^{\circ}C$, however non- heat treated specimen in the case of flow condition may be desirable.

The Effect of Age Heat-treatment to the Electro-Chemical Corrosion Behavior on Ti-6Al-4V (Ti-6Al-4V재의 전기화학적부식 거동에 미치는 시효열처리의 영향)

  • 백신영
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.24 no.6
    • /
    • pp.70-77
    • /
    • 2000
  • In this paper, the effect of solution and age heat treatment to the corrosion behavior for the Ti-6Al-4V alloy were studied by cyclic polarization methods. Ti-6Al-4V was solution heat treated at $1,066^{\circ}C$ and $966^{\circ}C$ for 5 hours, and followed by age heat treated at $650^{\circ}C$, $600^{\circ}C$ and $550^{\circ}C$ with 1, 2, 4, 8 and 16 hours under vacuum environment. Test solution was 3.5% NaCl with temperature $25^{\circ}C$. The obtained results were as follows: 1. Base metal was exhibited higher electrical charge than that of solution and aged material. With decrease of solution-treatment temperature from 1066 to $966^{\circ}C$, the electrical charge was increased due to softening of micro structure. 2. The corrosion resistance of specimen that solution treated at $966^{\circ}C$ for 5 hours and age heat treated at 650, 660 and $550^{\circ}C$ were increased with increase of aging time to 4, 8 and 16 hours respectively, and then decreased. 3. In case of 316L stainless steel, measured charge and corrosion potential was 0.0627 coulomb and -614 mV respectively. Corrosion resistance of Ti-6Al-4V was higher than that of 316L.

  • PDF

Electrochemical Corrosion Characteristics of AISI-type 316 L Stainless Steel in Anode-Gas Environment of MCFC (용융탄산염 연료전지의 Anode가스 분위기에서 AISI-type 316L stainless steel의 전기화학적 부식 특성)

  • Lee, Kab-Soo;Lim, Tae-Hoon;Hong, Seong-Ahn;Kim, Hwa-Yong
    • Journal of the Korean Electrochemical Society
    • /
    • v.5 no.2
    • /
    • pp.62-67
    • /
    • 2002
  • The corrosion of the metallic cell components is blown to be one of the major reason f3r the performance degradation and subsequently the life-time limitation of the MCFC. To elucidate the corrosion phenomena, a corrosion study with the AISI-type 316L stainless steel, the most widely used separator material, in 621Li/38K carbonate eutectic melt was carried out. Corrosion phenomena in an MCFC were observed to differ from one location to another due to different environmental condition. The stability of passive film was found to be responsible fur the variations in corrosion phenomena. According to the potentiodynamic analysis, the passive film formed in anode-gas environment was less stable than in cathode-gas environment. The potentiostatic method combined with XRD analysis in addition to the cyclicvoltammetry was conducted to get an insight on variety corrosion reaction of AISI-type 316L stainless steel in a carbonate melt.

Immunohistochemical study on the distribution of ion channels in rat trigeminal sensory nucleus (흰쥐 삼차신경 감각핵에 존재하는 이온통로의 분포에 관한 면역조직화학적 연구)

  • Park, Ho-Young;Choi, Gi-Woon;Choi, Ho-Young
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.3
    • /
    • pp.215-231
    • /
    • 2002
  • 삼차신경절의 뉴론이 구강악안면영역에서의 촉각, 압각, 온도각 및 통각 등 다양한 감각을 중추신경계로 전달하는 역할을 하는 것은 주지의 사실이다. 이러한 신경전달에 있어서 이온통로는 감각정보를 전달하는데 핵심적인 역할을 수행한다. 이 중 소디움 통로는 활동전위의 발생에 중요하며, 칼슘 통로는 시냅스 전도에 있어서 필수적인 역할을 수행하고, 포타슘 통로는 안정막전압의 유지 및 재분극에 관여한다. 최근에 여러 가지의 이온통로들의 뇌조직내의 분포에 관한 연구가 시작되고 있는데 삼차신경의 일차구심뉴론이 종지하는 삼차신경핵 즉 삼차신경 척수감각핵, 삼차신경 주감각핵, 삼차신경 중뇌핵 및 삼차신경 운동핵에 존재하는 이온통로에 관한 연구는 매우 희소하여 본 연구에서는 횐쥐의 삼차신경 핵에 존재하는 소디움, 칼슘 및 포타슘 이온통로들을 면역조직화학적 방법으로 조사하여 다음과 같은 결과를 얻었다. (1) 소디움 통로는 삼차신경 척수감각핵, 삼차신경 주감각핵 및 삼차신경 운동핵 모두에서 강하게 염색되었다. (2) 칼슘 통로는 삼차신경 척수감각핵에서는 N-type 통로가 중등도로 염색되었으며 , P/Q-type 통로는 약하게 염색되었으나 R-type 통로는 거의 염색되지 않았다. 삼차신경 주감각핵에서는 P/Q-type 통로가 매우 약하게 염색되었다. (3) 포타슘 통로는 삼차신경 척수감각핵과 삼차신경 주감각핵에서 inwardly rectifying 포타슘 통로(Kir 2.1)가 중등도로 염색되었고, voltage-gated 포타슘 통로(Kv 4.2)가 약하게 염색되었으며, BKCa는 그 염색 정도가 매우 약하게 나타났다. 이상의 결과를 종합해 볼 때 삼차신경 감각핵에는 소디움 통로의 분포가 가장 많았으며, 칼슘통로에서는 N-type이, 포타슘 통로 중에는 inwardly rectifying 통로(Kir 2.1)가 가장 많이 분포함을 관찰할 수 있었다.