• Title/Summary/Keyword: 분광필터

Search Result 76, Processing Time 0.023 seconds

Equi-spaced multichannel stabilization with a reference frequency from ($^13C_2H_2$) molecules and optical fiber fabry-perot filter (아세칠렌가스($^13C_2H_2$)분자의 흡수선을 이용한 기준 광신호 및 광섬유 파브리-페로 필터에 의한 등간격 다중채널의 안정화)

  • 이현재;류갑열;이동호;박창수
    • Korean Journal of Optics and Photonics
    • /
    • v.8 no.1
    • /
    • pp.68-72
    • /
    • 1997
  • Using one of the absorption lines of $^{13}C_2H_2$ molecules near the zero dispersion wavelength(1549.49nm) of dispersion shifted fiber, we stabilized center frequency of an optical fiber Fabry-Perot filter. The free spectral range of the filter is 100 GHz for 100 GHz channel allocation. For equi-spaced three channel multiplexing, channel locking of three DFB-LDs to transmission peaks of the fiber Fabry-Perot filter was tried. To investigate the effect of dithering current applied to each DFB-LD, the change of DFB-LD linewidth was measured.

  • PDF

Theoretical Calculation on Alpha Track Density by Using an Electrostatic Ion Spectrometer (정전기분광분석방법에 의한 알파입자비적밀도의 이론적 계산연구)

  • Yoon, Suk-Chul;Ha, Chung-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.18 no.1
    • /
    • pp.25-35
    • /
    • 1993
  • To develop a technique of theoretical alpha track density calculation for comparison with measured track density, an electrostatic ion spectrometer was specially designed and fabricated. The mobility spectrum of first radon daughter(Po-218) in the range of $0.07{\sim}5.0cm^2/V\;s$ from the radon chamber was measured using-the electrostatic ion spectrometer. Measurement was taken in a radon chamber operated using dry particle free air passed through silica gel, activated charcoal and molecular sieve filters. The mobility of a new-born Po-218 ion measured by the electrostatic ion spectrometer was determined to be $1.92cm^2/V\;s$. A comparison of the theoretical and measured alpha track densities was completed and uncertainties concerning the shape of the spectrum were analyzed. It was found that the discrepancies in track densities are primarily Que to the neglect of wall loss of ions in the theoretical track density calculation.

  • PDF

The comparison of spatial/spectral distortion on the hybrid pansharpened images by the spatial correlation methods (공간 상관도 기법에 따른 하이브리드 융합영상의 공간/분광 왜곡 평가)

  • Choi, Jae-Wan;Kim, Dae-Sung;Kim, Yong-Ii
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.29 no.2
    • /
    • pp.175-181
    • /
    • 2011
  • In remote sensing, it has been a difficult task to obtain a multispectral image with high spatial resolution because of the technical limitation of satellite sensors. In order to solve these problems, various pansharpening algorithms have been tried and proposed. However, most pansharpened images created by various approaches tend to distort the spectral characteristics of the original multispectral image or decrease the visual sharpness of the panchromatic image. To minimize the spectral distortion of pansharpened image while preserving spatial information of the panchromatic image, a hybrid pansharpening algorithm based on the spatial correlation was proposed. In this paper, we analyzed the spatial and spectral distortion of the hybrid pansharpened images generated by the various spatial correlation methods. In the experiments, we proved that the method by using Laplacian filtering was more efficient than other high frequency extraction algorithms in the viewpoint of spectral distortion and spatial sharpness.

Measurement and Assessment of Absolute Quantification from in Vitro Canine Brain Metabolites Using 500 MHz Proton Nuclear Magnetic Resonance Spectroscopy: Preliminary Results (개의 뇌 조직로부터 추출한 대사물질의 절대농도 측정 및 평가: 500 MHz 고자장 핵자기공명분광법을 이용한 예비연구결과)

  • Woo, Dong-Cheol;Bang, Eun-Jung;Choi, Chi-Bong;Lee, Sung-Ho;Kim, Sang-Soo;Rhim, Hyang-Shuk;Kim, Hwi-Yool;Choe, Bo-Young
    • Investigative Magnetic Resonance Imaging
    • /
    • v.12 no.2
    • /
    • pp.100-106
    • /
    • 2008
  • The purpose of this study was to confirm the exactitude of in vitro nuclear magnetic resonance spectroscopy(NMRS) and to complement the defect of in vivo NMRS. It has been difficult to understand the metabolism of a cerebellum using in vivo NMRS owing to the generated inhomogeneity of magnetic fields (B0 and B1 field) by the complexity of the cerebellum structure. Thus, this study tried to more exactly analyze the metabolism of a canine cerebellum using the cell extraction and high resolution NMRS. In order to conduct the absolute metabolic quantification in a canine cerebellum, the spectrum of our phantom included in various brain metabolites (i.e., NAA, Cr, Cho, Ins, Lac, GABA, Glu, Gln, Tau and Ala) was obtained. The canine cerebellum tissue was extracted using the methanol-chloroform water extraction (M/C extraction) and one group was filtered and the other group was not under extract processing. Finally, NMRS of a phantom solution and two extract solution (90% D2O) was progressed using a 500MHz (11.4 T) NMR machine. Filtering a solution of the tissue extract increased the signal to noise ratio (SNR). The metabolic concentrations of a canine cerebellum were more close to rat’s metabolic concentration than human’s metabolic concentration. The present study demonstrates the absolute quantification technique in vitro high resolution NMRS with tissue extraction as the method to accurately measure metabolite concentration.

  • PDF

Spectral Resolution Enhancement of Acousto-Optic Tunable Filter(AOTF) using Incident Angle Variation (음향광학변조필터의 입사각 변화를 이용한 분해능 향상 방법)

  • You, Jang-Woo;Ahn, Jeong-Ho;Kim, Dae-suk;Kwak, Yoon-Keun;Kim, Soo-Hyun;Lee, Yun-Woo;Whang, In-Duk
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.607-612
    • /
    • 2004
  • Spectral resolution enhancement method of Acousto-Optic Tunable Filter (AOTF) using incident light angle variation is described. AOTF is a small, mechanically rigid, high speed and spectral resolution light tunable filter. The basic theory of AOTF and its experimental verification is described. AOTF can generate two opposite polarized light simultaneously which wavelength can be changed by incident angle variation. We focused on the common region of two filtered light at the specific incident angle. This region can be used to enhance the spectral resolution of AOTF.

  • PDF

Estimation of the Spectral Reflectance based on the Multispectral Imaging System (다중 스펙트럼 영상 시스템 기반의 스펙트럼 반사율 추정)

  • Yoo, Hyunjin;Kim, Duck Bong;Lee, Kwan H.
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2010.04a
    • /
    • pp.546-549
    • /
    • 2010
  • RGB 영상의 색 재현성과 조건등색 등의 한계를 개선하기 위해 다중스펙트럼 영상을 활용하는 연구가 활발히 진행되고 있다. 다중스펙트럼 영상을 측정하기 위해서 흑백카메라와 3 개 이상의 컬러 필터들을 이용한다. 본 연구에서는 LCTF 를 사용하여 400nm 에서 720nm 까지 10nm 단위로 33 개의 필터를 사용한다. 이러한 다중스펙트럼 영상 측정 시스템의 특성화를 수행하기 위해 컬러체커뿐만 아니라 광원정보까지 이용하며, 사물의 스펙트럼 반사율도 추정한다. 따라서 분광방사계 보다 빠르게 영상 기반으로 스펙트럼 반사율을 측정할 수 있다. 다양한 광원 조건에서 특성화를 수행하며, 매번 레퍼런스 차트를 측정할 필요 없이 간단히 광원만 측정해도 되는 것을 보인다. 또한 전경영상에서 원하는 영역을 광원환경이 다른 배경 영상에 합성할 때, 자연스러운 사물의 색 변환이 가능하여 보다 실제에 가까운 합성 영상을 생성한다.

Development of monitor color measurement device for color management system (CMS 구현을 위한 모니터 색 측정 장비 개발)

  • 박철호;김홍석;박승옥
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2003.02a
    • /
    • pp.116-117
    • /
    • 2003
  • 현재 입·출력 장치 간의 색 불일치 문제를 해결하기 위한 방안으로 각 장치의 색 특성 정보를 담고있는 ICC 프로파일을 기반으로 한 CMS(색 관리 시스템)가 개발이 되고 있다. 정확한 색 관리가 이루어지기 위해서는 무엇보다 출력물의 평가 기준이 되는 모니터의 올바른 보정이 이루어져야 하는데, 이에 따른 방안으로 색 측정장비를 통한 소프트웨어적 보정 방법이 사용되고 있다. 색 측정장비는 분광 방식의 Spectrometer 타입과 필터식의 Colorimeter 타입으로 구분이 된다. (중략)

  • PDF

A Study on the Edge Detection for Road Information based on the IKONOS (IKONOS 영상에서 도로정보추출을 위한 경계검출에 관한 연구)

  • Choi, Hyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.3
    • /
    • pp.593-598
    • /
    • 2006
  • High-resolution satellite imagery has many benefits, compared to aerial photo in the wide area as well as multi-spectral character. So, it can be used well for constructing GIS data when making digital map. This study analysed the possibilities that road information derived automatically from IKONOS can be used for making ITS system or updating digital map of the urban areas where change frequently and producing satellite image map. In this study, Sobel was applied for road edge dectection after low pass filtering. As the results, it's possible for low pass filtering and high pass filtering to be used as the basic data for ITS construction when extracting edge roads and constructs according to the characteristic of high-resolution satellite imagery.

마젤란 은하내 외계행성 탐색

  • Lee, Jae-U;Kim, Seung-Ri;Lee, Chung-Uk;Park, Byeong-Gon;Jeong, Seon-Ju;Ryu, Yun-Hyeon;Gu, Jae-Rim
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.2
    • /
    • pp.120.1-120.1
    • /
    • 2011
  • 현대 천문학의 주요한 이슈 중 하나인 외계행성은 570개 이상 발견되었는데, 이들 모두 우리 은하내 외계행성들이다. 우리는 KMTNet 광시야 관측시스템을 이용하여 마젤란 은하내 외계행성을 Transit 방법으로 탐색 관측하여 외부은하 최초의 외계행성을 발견하고자 한다. 이제까지 알려진 Transit 행성들의 별표면 통과시간(transit duration)은 대부분 100-300분 사이에 분포하기 때문에, 이 현상의 검출은 최대 10분의 시간분해능을 필요로 한다. 한편, KMTNet 망원경은 마젤란 은하내 21등급의 별을 I 필터에서 10분의 노출로 1%의 측정정밀도를 얻을 수 있고, 8-10미터급 대형망원경을 이용하면 태양질량의 21등급 별을 공전하는 목성형 행성들의 분광후속 관측이 가능하다. 우리는 KMTNet으로 마젤란 은하내 19-21등급에 있는 F-G형 주계열성들과 청색수평가지별들(blue horizontal branch star)을 I 필터(관측 시작, 중간, 끝 시간에는 V 필터도 사용)에서 10분의 노출로 시계열 측광 관측하면, 다수의 Transit 외계행성을 발견할 수 있을 것으로 기대한다. 이와 더불어, 수년의 장시간 관측자료로부터 RR Lyr, ${\delta}$ Sct 및 식변광성의 극대/극심시각을 정밀하게 측정하여 Timing 방법으로 항성계 주위를 공전하는 장주기 외계행성을 발견할 수 있을 뿐만 아니라, 중력렌즈(self-lensing) 현상을 보이는 외계행성도 검출가능하다.

  • PDF

Measurement of oxygen isotope ratio using tunable diode laser absorption spectroscopy (다이오드 레이저 흡수분광법을 이용한 산소 동위원소의 성분비 측정)

  • Park, Sang-Eon;Jung, Do-Young;Kim, Jae-Woo;Ko, Kwang-Hoon;Im, Kwon;Jung, Eui-Chang;Kim, Chul-Joong
    • Korean Journal of Optics and Photonics
    • /
    • v.15 no.1
    • /
    • pp.1-5
    • /
    • 2004
  • Tunable diode laser absorption spectroscopy was performed for analysis of the H$_2$$^{18}$ O/H$_2$$^{16}$ O isotope ratio of a water sample which was enriched by the membrane distillation method. In order to improve the signal-to-noise ratio, the wavelength modulation spectroscopic method was used with a lock-in amplifier. The fringe noise could be suppressed by using the FFT (Fast Fourier Transform) lowpass filter and the optimization of the modulation depth of the laser frequency. The maximum deviation of $\delta$-value was measured to be$\pm$4$\textperthousand$.