• Title/Summary/Keyword: 부하 전력 모니터링

Search Result 103, Processing Time 0.025 seconds

A Study on the Analysis of Electric Energy Pattern Based on Improved Real Time NIALM (개선된 실시간 NIALM 기반의 전기 에너지 패턴 분석에 관한 연구)

  • Jeong, Han-Sang;Sung, Kyung-Sang;Oh, Hae-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.4
    • /
    • pp.34-42
    • /
    • 2017
  • Since existing nonintrusive appliance load monitoring (NIALM) studies assume that voltage fluctuations are negligible for load identification, and do not affect the identification results, the power factor or harmonic signals associated with voltage are generally not considered parameters for load identification, which limits the application of NIALM in the Smart Home sector. Experiments in this paper indicate that the parameters related to voltage and the characteristics of harmonics should be used to improve the accuracy and reliability of the load monitoring system. Therefore, in this paper, we propose an improved NIALM method that can efficiently analyze the types of household appliances and electrical energy usage in a home network environment. The proposed method is able to analyze the energy usage pattern by analyzing operation characteristics inherent to household appliances using harmonic characteristics of some household appliances as recognition parameters. Through the proposed method, we expect to be able to provide services to the smart grid electric power demand management market and increase the energy efficiency of home appliances actually operating in a home network.

Operating Characteristic Analysis of Optic Temperature Sensor for Overheat Detection in Panel Board (분전함에서 이상발열 감지를 위한 광온도센서의 동작특성 분석)

  • Moon, Hyun-Wook;Kim, Dong-Woo;Gil, Hyung-Jun;Kim, Dong-Ook;Lee, Ki-Yeon;Kim, Hyang-Kon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.10
    • /
    • pp.100-106
    • /
    • 2009
  • In this study, methods of overheat detection at the coupling or wire in electrical facility are investigated, operating characteristic about the optic temperature sensor for continuous on-line temperature monitoring in diagnostics system of electrical facility is analyzed. Heating sources in the experiment for operating characteristics of optic temperature sensor use black body and hot plate, output voltage of optic temperature sensor in accordance with temperature variation is analyzed. Overheat generation due to poor contact at the circuit breaker in panel board detects using a thermocouple, infrared thermal camera and optic temperature sensor, and experiment results are analyzed. The effect of optic temperature sensor is the same that of other methods. These results expect to use basic research material for adjusting field of electrical diagnostics system using RFID type optic temperature sensor in the near future.

An Auto-Switching Dual-Input Energy Harvesting Circuit (자동 스위칭 기능을 갖는 이중입력 에너지 하베스팅 회로)

  • Park, Yeon-kyoung;Kim, Mi-rae;Lee, Seung-hee;Yang, Min-Jae;Yoon, Eun-jung;Yu, Chong-gun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.10a
    • /
    • pp.577-580
    • /
    • 2014
  • In this paper an auto-switching dual-input energy harvesting circuit is proposed. Since the maximum power points of a thermoelectric generator(TEG) output and a vibration device(PEG) output is 1/2 of their open-circuit voltage, an identical MPPT controller can be used for both energy sources. The proposed circuit monitors the outputs of the TEG and PEG, and chooses the energy source generating a higher output using an auto-switching controller, and then harvests the maximum power from the selected device using a MPPT controller. The harvested energy is boosted through a charge pump and stored in a storage capacitor. The stored energy is provided to a load through a PMU(Power Management Unit). The proposed circuit is designed in a $0.35{\mu}m$ CMOS process and its functionality has been verified through extensive simulations. The designed chip occupies $1.4mm{\times}1.2mm$ including pads.

  • PDF

Dual Fuel Generator Modeling and Simulation for Development of PMS HILS (PMS HILS 구축을 위한 Dual Fuel Generator 모델링 및 시뮬레이션)

  • Hwang, Joon-Tae;Hong, Suk-Yoon;Kwon, Hyun-Wung;Lee, Kwang-Kook;Song, Jee-Hun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.3
    • /
    • pp.613-619
    • /
    • 2017
  • In this paper, DF(Dual Fuel) Generator modeling, which uses both conventional diesel fuel and LNG fuel, has been performed and monitoring system has been developed based on MATLAB/SIMULINK for the development of PMS(Power Management System) HILS(Hardware In the Loop Simulation). The principal components modeling of DF Generator are DF engine which provides the mechanical power and synchronous generator which convert the mechanical power into electrical power. Submodels, such as throttle body, intake manifold, torque generation and mass of LNG and diesel Quantity are used to perform DF engine. Also, governor is used for load sharing between paralleled DF generators to share a total load that exceeds the capacity of a single generator. To verify modeling of DF Generator designated ship lumped load Simulation is carried out. A validity of DF Generator has been verified by comparison between simulation results and estimated result from the designated lumped load.

The Tracking Photovoltaic System by One sensor Type (One sensor방식의 추적식 PV System)

  • Ko, Jae-Hong;Park, Jeong-Min
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.10
    • /
    • pp.4733-4739
    • /
    • 2012
  • While traditional two-axis tracking systems with double sensors had been using two sensors to control azimuth and elevation angle of the sun so that a solar cell module would make a normal line with the sun, this paper proposed a new two-axis system that can achieve the same performance with only one sensor in it. It is Two-axis tracking system that control azimuth and elevation to control to be reduced for solar cell module as proposed tracking system uses 1 sensors and the sun always forms normal. Two-axis tracking system of one sensor method that propose in paper that could reduce electric power consumption and sees than fixed type preventing action and the most efficient driving and needless drive could confirm that generation efficiency of about 23 [%] increases. To heighten efficiency of solar cell doing to receive more sunlights chasing the sun, done tracking device have proceeded a lot of studies in large size way. Therefore, is expected that will do big part in the sun tracking supply through utility study about persistent generation efficiency constructing monitoring system of the sun tracking of this paper.

International Standardization and Implementation of Home Energy Saving System for Smart Grid (스마트 그리드를 위한 홈 에너지 절감 시스템의 IEC 국제표준화 및 구현)

  • Choi, Kwang-Soon;Lee, Sang-Won;Park, Young-Choong;Jung, Kwang-Mo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37C no.12
    • /
    • pp.1222-1229
    • /
    • 2012
  • For the reduction of electric energy consumption and its efficient use at homes or buildings, a new work item proposal for new architecture and functional requirements of Energy Saving System (ESS) was proposed to IEC TC 100 and accepted as a new project, IEC PT 62654 in 2009. Recently, the final ballot for publication passed without negative votes and IEC TS 62654 was finally published in August 2012. For the verification of this standard, Prototype of ESS system composed of an ESS server, ESS clients, and portable ESS terminal were especially implemented in parallel with the standardization. Electric Power Control and Management (EPCM) protocol for the communication between ESS server and clients was also implemented, which supports self-configuration of ESS network, power consumption monitoring, remote power control, and additional functions for intelligent energy saving services.

Development of DAP(Dose Area Product) for Radiation Evaluation of Medical and Industrial X-ray generator (의료 및 산업용 X-선 발생장치의 선량평가를 위한 면적선량계(DAP) 개발)

  • Kwak, Dong-Hoon;Lee, Sang-Heon;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.22 no.2
    • /
    • pp.495-498
    • /
    • 2018
  • In this paper, we propose an DAP system for dose evaluation of medical and industrial X-ray generator. Based on the DAP measurement technique using the Ion-Chamber, the proposed system can clearly measure the exposure radiation dose generated by the diagnostic X-ray apparatus. The hardware part of the DAP measures the amount of charge in the air that is captured by an X-ray. The high-speed processing algorithm part for cumulative radiation dose measurement through microcurrent measures the amount of charge captured by X-ray at a low implementation cost (power) with no input loss. The wired/wireless transmission/reception protocol part synchronized with the operation of the X-ray generator improves communication speed. The PC-based control program part for interlocking and aging measures the amount of X-ray generated in real time and enables measurement graphs and numerical value monitoring through PC GUI. As a result of evaluating the performance of the proposed system in an accredited testing laboratory, the measured values using DAP increased linearly in each energy band (30, 60, 100, 150 kV). In addition, since the standard deviation of the measured value at the point of 4 division was ${\pm}1.25%$, it was confirmed that the DAP showed uniform measurements regardless of location. It was confirmed that the normal operation was not less than ${\pm}4.2%$ of the international standard.

A Study on the Estimation of Energy Expenditure and falls measurement system for the elderly (고령자를 위한 에너지 소비 추정 및 낙상 측정 시스템에 관한 연구)

  • Lim, Chae-Young;Jeon, Ki-Man;Ko, Kwang-Cheol;Koh, Kwang-Nak;Kim, Kyung-Ho
    • Journal of the Korea Society of Computer and Information
    • /
    • v.17 no.4
    • /
    • pp.1-9
    • /
    • 2012
  • As we are turnning into the aged society, accidents by falling down are increasing in the aged people's group. In this paper, we design the system with the 3-Axis acceleration sensor which is composed by a single chip. The body activity signal is measured with the signal detector and RF communicator in this proposed system and the and falling by the entering signal pattern analysis with 3-Axis acceleration sensor. For the RF communication, we are using nRF24L01p and 8bits ATmega uC for the processor. The error of energy expenditure estimation between motor driven treadmill and proposed a body activity module was 7.8% respectively. Human activities and falling is monitored according to analyze and judge the critical value of the Signal Vector. as falled down if they don't turn off the alarm after specific period and the aged person's after falling down activities are their position and more.

Analysis of Discharge and Water Quality change of Doam Reservoir by Climate Change (기후변화에 따른 도암댐유역의 유출 및 수질변화 분석)

  • Kim, Jung-Min;Kim, Young-Do;Kang, Boo-Sik
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2012.05a
    • /
    • pp.908-908
    • /
    • 2012
  • 국내 기후 특성상 하절기에 집중되는 강우로 인해 댐의 건설을 홍수조절, 용수확보 및 전력생산 등의 목적에 있어서 불가피하다. 이와 같은 저수지와 하류하천은 댐 수문 개폐에 따라 흐름변화로 인하여 수체의 거동 및 수질 변화가 발생하며, 일반적인 하천과는 다른 특성을 지니게 된다. 또한 수심이 깊은 저수지의 경우에는 흐름방향과 더불어 수심 방향의 특성도 중요하며, 수리 및 수질 모형의 연계를 통한 3차원적인 해석을 필요로 한다. 유역 내 지상 또는 대기에서 발생한 모든 오염물질은 강우에 의해 하천과 호수와 같은 수체로 유입되며, 강우가 발생했을 때 유역의 토지피복 상태와 수리, 지형, 강우강도, 토양의 특성에 의해 하천으로 유입되는 오염물질의 농도와 부하특성이 달라진다. 비점오염물질의 축적이 가능한 호수나 저수지에서는 비점오염원의 유입이 더 큰 문제가 되며, 유량이 극히 미미한 하천의 경우에는 강우초기에 일시에 집중적으로 유입되는 초기 오염 부하량이 문제가 된다. 강우유출수의 하천 유입은 강우 현상과 밀접한 관계를 맺고 있으므로 그 제어가 쉽지 않다. 이러므로 이를 총괄하는 유역통합관리기술이 필요로 하며, 기존의 유역통합관리기술은 댐 상류유역을 중심으로 개발되고 있으며, 댐 상류유역과 저수지, 하류하천으로 구분되어 연구되어 왔다. 또한 각각의 모형이 개별적으로 적용되어 통합적인 평가시스템이 표준화되지 않은 관계로 댐 상하류 모니터링 자료가 연계된 실무 적용이 이루어지지 않고 있다. 따라서 하천 수리 수문학적 역학구조를 이해하고 그 특성에 적합하게 평가할 수 있는 표준화된 시스템이 구축되어야 한다. 또한 효과적인 유역통합관리를 위해서는 하천의 현재 뿐만 아니라 장래에 대한 예측부분도 포함되어야 한다. 본 연구에서는 댐 유역에서의 유출과 수질 변화를 모의하고 이를 이용하여 저수지 내에서의 오염물질 거동에 대해서 해석하였다. 또한 기후변화에 따른 유역, 저수지 및 하천에 미치는 영향을 고려하기 위하여 고해상도 지역기후전망 모의자료를 이용하여 수문학적 스케일로 통계적 상세화한 후 지역별 상세수문시나리오를 생산하여 미래 예측에 활용하였다. 기후변화 시나리오의 상세화를 통한 상세지역의 기후를 예측하고, 예측된 기상자료를 이용하여 유역모델을 모의하여 미래의 유출 및 수질 변화를 파악할 수 있는 기술 개발로 인해 저수지의 운영에 도움을 주고, 주수지의 치수증대 사업 등 유출의 변화에 따른 하류하천 변화를 파악할 수 있고, 기후변화에 따른 하류하천에 대한 홍수기 때 치수, 이수 및 방재에 대하여 기초자료를 제공할 수 있을 것으로 판단된다.

  • PDF

Implementation and Evaluation of the LUTS Diagnosis System Using FPGA (FPGA를 이용한 LUTS 진단 시스템 구현 및 평가)

  • Jeong, Do-Un;Chung, Wan-Young;Jeon, Gye-Rock
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.8 no.1
    • /
    • pp.6-14
    • /
    • 2007
  • The purpose of urodynamic investigation is to determine information on the function of the urinary system. One of the most frequently used measurement procedures in urodynamics is filling and voiding cystometry using invasive method. But in this method transurethral catheter is use and it makes patients uncomfortable. The aim of this study was to implement the system that could evaluate the function of urinary tract with noninvasive and comfortable method. Therefor in this study, a sensor and measuring system were implemented to measure uroflow, urophonography and noninvasive bladder pressure signal during urination for diagnosing the LUTS(lower urinary tract symptoms) using noninvasive method. The implemented system compose of the sensor parts, signal conditioning parts, system control parts using FPGA and PC monitoring program. For the evaluation of the implemented system, the simulation of system's control part was performed and the model system for the lower urinary system was designed. From the evaluation of the model system, the mean error rate of the uroflow measurement part was 1.08% and coefficient of variation was 1,48. And the mean error rate of the noninvasive bladder pressure measurement part was 2.41% and coefficient of variation was 2.81. urophongraphy signal analysis was accomplished in a time domain and frequency domain. Average RMS power was used in a time domain analysis, and MF was used in a frequency domain analysis. From the evaluation of the model system average RMS power and MF was dependent on the occlusion degree significantly and median frequency range of $60{\sim}160Hz$ was correlated with the occlusion.

  • PDF