• Title/Summary/Keyword: 부하용량

Search Result 702, Processing Time 0.034 seconds

Analysis of the Risk of Heat Generation due to Bolt Loosening in Terminal Block Connector Parts (볼트풀림에 의한 터미널 블록의 접속부 발열 위험성 분석)

  • Yeon, Yeong-Mo;Kim, Seung-Hee
    • Fire Science and Engineering
    • /
    • v.34 no.3
    • /
    • pp.67-75
    • /
    • 2020
  • In this study, the risk of heat generation due to normal and overload currents that vary with the abnormal loosening angle of wire-connecting bolts were identified. The risks were analyzed based on the thermal characteristics to minimize the carbonization accidents of terminal blocks inside distribution panels typically used in industrial sites. We applied a method for measuring the heating temperature and temperature variations in the terminal blocks in real-time by installing a resistance temperature detector sensor board in the terminal block. The experimental results showed that the terminal block model with a low-rated current exhibited a higher heating temperature, thus, confirming the need to select the terminal block capacity based on load currents. Additionally, the higher the rated current of the terminal block with a high-rated current and the higher the degree of loosening, the faster the carbonization point. Such heating temperature monitoring enabled real-time thermal temperature measurement and a step-by-step risk level setting through thermal analysis. The results of the measurement and analysis of carbonization risks can provide a theoretical basis for further research regarding the risk of fire due to carbonization. Furthermore, the deterioration measurement method using the temperature sensor board developed in this study is widely applicable to prevent fires caused by poor electrical contact as well as risk-level management.

Pretreatment Condition in the Full Scale Dissolved Air Flotation Process Using a DAF Pump (DAF 펌프를 이용한 실규모 용존공기부상 공정의 전처리 조건)

  • Lee, Chang-Han;An, Dae-Myung;Kim, Seong-Soo;Cho, Seok-Ho;Ahn, Kab-Hwan
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.1
    • /
    • pp.58-63
    • /
    • 2009
  • Dissolved air flotation (DAF) process is generally considered more effective than sedimentation process in raw water containing algae, humus materials, and low density particles. This study presents the treatment efficiencies by the coagulation and flocculation conditions at a drinking water treatment plant using a laboratory tester and the full scale DAF pump system. The full scale DAF pump system (F-DAF) in this study had a capacity of 5,000 $m^3$/d and a hydraulic surface loading of 10 m/hr. F-DAF in D drinking water treatment plant was continuously operated to determine the operational performance and pretreatment (mixing and coagulation) conditions. Results in the laboratory experiment showed that the optimum coagulant (PSO-M) doses required to 2.7~4.5 mL/$m^3$/NTU with raw water turbidity from 13.8 NTU to 56.3 NTU. F-DAF in the optimum coagulant dosage could be operated in effluent turbidity of 1 NTU or below for a month.

Real-time Control of Biological Animal Wastewater Treatment Process and Stability of Control Parameters (생물학적 축산폐수 처리공정의 자동제어 방법 및 제어 인자의 안정성)

  • Kim, W.Y.;Jung, J.H.;Ra, C.S.
    • Journal of Animal Science and Technology
    • /
    • v.46 no.2
    • /
    • pp.251-260
    • /
    • 2004
  • The feasibility and stability of ORP, pH(mV) and DO as a real-time control parameter for SBR process were evaluated in this study. During operation, NBP(nitrogen break point) and NKP(nitrate knee point), which reveal the biological and chemical changes of pollutants, were clearly observed on ORP and pH(mV)-time profiles, and those control points were easily detected by tracking the moving slope changes(MSC). However, when balance of aeration rate to loading rate, or to OUR(oxygen uptake rate), was not optimally maintained, either false NBP was occurred on ORP and DO curves before the appearance of real NBP or specific NBP feature was disappeared on ORP curve. Under that condition, however, very distinct NBP was found on pH(mV)-time profile, and stable detection of that point was feasible by tracking MSC. These results might mean that pH(mV) is superior real-time control parameter for aerobic process than ORP and DO. Meanwhile, as a real-time control parameter for anoxic process, ORP was very stable and more useful parameter than others. Based on these results, a stable real-time control of process can be achieved by using the ORP and pH(mv) parameters in combination rather than using separately. A complete removal of pollutants could be always ensured with this real-time control technology, despite the variations of wastewater and operation condition, as well as an optimization of treatment time and capacity could be feasible.

Present Status of Hydrogen Refueling Station in KIER (KIER 수소충전소 구축 현황)

  • Seo, Dong-Joo;Seo, Yu-Taek;Seo, Yong-Seog;Park, Sang-Ho;Roh, Hyun-Seog;Jeong, Jin-Hyeok;Yoon, Wang-Lai
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.21-24
    • /
    • 2006
  • 수소의 소규모 분산 생산 기술은 본격 적 인 수소 인프라가 도입되기 전에 연료전지 자동차의 수소 충전용이나 분산 발전형 연료전지의 수소 공급을 위해 필요하다. 생산 용량은 수소 기준으로 $20{\sim}100 Nm^3/hr$ 정도로 현재로선 천연가스의 수증기 개 질법이 가장 경제적인 공정으로 알려져 있다. 소규모 생산에 따른 열효율 저하를 줄이 기 위해 단위 공정들이 통합된 컴팩트 개질 시스템의 개발이 필요하다. 연료전지 자동차용 수소 인프라 조기 구축을 위하여 수소충전소 구축과 국산화 천연가스 수증기 개질기 개발을 병행하여 진행하였다. 수소 충전소 구축 부분은 충전소 부지 확보, 건물 건축, 각종 유틸리 티 설치의 토목 부분과 천연가스 개질형 수소 제조 유닛 설치, 수소 압축, 저장, 디스펜싱 시스템 설치를 포함하고 있으며 고압 설비에 대한 인허가 대응 및 안전대책 작업도 진행하였다. 구축된 수소충전소는 향후 연료전지 자동차 연계 실증 프로그램에 활용할 수 있다. 국산화 핵심 기술 개발을 위하여 열 및 시스템 통합 설계에 의 해 천연가스 수증기 개질기를 제작하고 내부 열교환 구조에 따른 개질기의 성능을 평가하였다. 개발된 개질기는 개질온도 $720^{\circ}C$, 수증기 대 카본 비 2.7의 운전조건에서 $23Nm^3/h$ 이상의 수소 생산이 가능하였으며 73% 이상의 개질 효율을 나타내었다. 개발된 천연가스 수증기 개질기는 향후 수소 정제용 PSA(Pressure Swing Adsorption) 시스템과 연계하여 수소충전소 국산화 엔지니어링 설계 패키지 개발의 핵심 기 술로 사용할 계획이다.시간 정도 운전한 후 시스템을 정지하였다 메탄 전환율과 일산화 탄소 농도, 열효율을 모니터링 하고 있으며, 현재까지 초기 성능을 그대로 유지하고 있다. 앞으로 일일시동-정지 운전 시험을 지속하면서 초기 시동 특성 및 부하 변동에 따른 응답 특성 개선, 그리고 연료전지와의 연계 운전을 실시할 예정이다 한다. 단위 전지 운전 온도 $130^{\circ}C$, 상대습도 37%의 운전 조건에서도 상당히 우수한 전지 성능을 보임에 따라 고온/저가습 조건에서 상용 Nafion 112 막보다 우수한 막 특성을 나타냄을 확인하였다.소/배후방사능비는 각각 $2.18{\pm}0.03,\;2.56{\pm}0.11,\;3.08{\pm}0.18,\;3.77{\pm}0.17,\;4.70{\pm}0.45$ 그리고 $5.59{\pm}0.40$이었고, $^{67}Ga$-citrate의 경우 2시간, 24시간, 48시간에 $3.06{\pm}0.84,\;4.12{\pm}0.54\;4.55{\pm}0.74 $이었다. 결론 : Transferrin에 $^{99m}Tc$을 이용한 방사성표지가 성공적으로 이루어졌고, $^{99m}Tc$-transferrin의 표지효율은 8시간까지 95% 이상의 안정된 방사성표지효율을 보였다. $^{99m}Tc$-transferrin을 이용한 감염영상을 성공적으로 얻을 수 있었으며, $^{67}Ga$-citrate 영상과 비교하여 더 빠른 시간 안에 우수한 영상을 얻을 수 있었다. 그러므로 $^{

  • PDF

Experimental study on cooling performance characteristics of hybrid refrigeration system in a heavy duty vehicle (상용차 하이브리드 냉방시스템 냉방 성능 특성 연구)

  • Lee, Ho-Seong;Jeon, Hanbyeol;Kim, Jung-Il;Lee, Moo-Yeon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.1
    • /
    • pp.419-425
    • /
    • 2019
  • The objective of this study was to investigate the cooling performance characteristics of a hybrid refrigeration system in a heavy duty vehicle. The tested hybrid refrigeration system had additionally an electric compressor besides the present mechanical compressor for selective use according to the operating conditions. The applied electric compressor was a scroll type and with 18.0 cc displacement. In order to analyze the performance characteristics of the hybrid refrigeration system with respect to the cooling capacity and Coefficient of Performance (COP), other components, including two different types of compressors, were installed and tested under various operating conditions such as compressor speed and air flow rate of the evaporator. When the electric compressor was operated at 4,500 rev/min, the cooling capacity was about 4.0kW and COP was 3.5. When the mechanical compressor was operated, whereas the cooling capacity was higher than the electric controlled compressor, COP was lower due to the larger displacement and higher power consumption. To analyze the hybrid system operating characteristics due to reasonable cooling capacity with electric compressor operation, the mechanical compressor and electric compressor were operated by turns every 10 minutes under certain system operating conditions. Because surge pressure occurred when both compressors were switched on, the operating strategy required some time to balance the system pressure.

Improvement of charging efficiency of AGM lead acid battery through formation pattern research (Formation pattern 연구를 통한 AGM 연축전지의 충전 효율 향상)

  • Kim, Sung Joon;Son, Jeong Hun;Kim, Bong-Gu;Jung, Yeon Gil
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.31 no.1
    • /
    • pp.55-62
    • /
    • 2021
  • In order to improve fuel economy and reduce CO2, HEV adopts ISG system as a standard. This ISG system increased the electric load that the battery had to bear, and the number of starting increased rapidly. AGM Lead Acid batteries have been developed and used, but the charging time is about three times longer as the electrolyte amount control during formation must be maintained at a higher level compared to conventional lead-acid batteries. In this study, we tried to shorten the charging time by increasing the charging efficiency through the optimization of the formation pattern. In order to optimize the Formation Pattern, 10 charging steps and 6 discharging steps were applied to 16 multi steps, and the charging current for each step was controlled, and the test was conducted under 4 conditions (21 hr, 24 hr, 27 hr, 30 hr). As a result of simultaneous application of multi-step and discharge step, it was verified that minimizing the current loss and eliminating the sudden polarization during charging contributes to the improvement of charging efficiency. As a result, it showed excellent results in reducing the charging time by about 30 % with improved charging efficiency compared to the previous one.

Influence of Liquid Pig Manure on Rice Growth and Nutrient Movement in Paddy Soil under Different Drainage Conditions (배수조건이 다른 논에서 돈분뇨 액비시용이 벼 생육 및 양분이동에 미치는 영향)

  • Kim, Jong-Gu;Lee, Kyeong-Bo;Lee, Deog-Bae;Lee, Sang-Bok;Na, Seoung-Yong
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.37 no.2
    • /
    • pp.97-103
    • /
    • 2004
  • This study was performed to assess the influences of liquid pig manure (LPM) on the rice growth and nutrient behavior in soil under two different drainage comditions. Soils of paddy field were Jeonbuk and Gangseo series, and drainage conditions of the soils were imperfectly drained and moderate well drained, respectively, Application of LPM was based on nitrogen, and the treatments included 110 (LPM-N100%), 165 (LPM-N150%) and $220(LPM-N200%)kg\;N\;ha^{-1}$. In the LPM-N150% treatment, rice growth and yield were similar to the control treatment of conventional chemical fertilizer application. Rice yield of moderately well drainedfield were 3-11% higher than that of imperfectly drained field. Loss of nitrogen through $NH_3$ gas after application of LPM was higher in no plowing than in rotary plowing field. Losses of $NO_3-N$, $NH_4-N$, $SO_4$, Ca and K through runoff water were increased as the amount of LPM application increased. Losses of $NO_3-N$ and K through infiltration were higher in LPM-150% and LPM-N200% treatments compared to the chemical fertilizer treatment. Contents of $NO_3-N$ in infiltration water measured from trasplanting to tillering stage was higher at the moderately well drained condition than imperfectly drained condition. Contents of $P_2O_5$ and K in soil were accumulated by application of LPM compared to the chemical fertilizer plot.

Efficacy of Low-dose Hydrocortisone Infusion for Patients with Severe Community-acquired Pneumonia Who Invasive Mechanical Ventilation (기계 환기가 요구된 중증 지역사회 획득 폐렴에서 저용량 하이드로코르티손 주입의 효과)

  • Kim, Ho Cheol;Lee, Seung Jun;Ham, Hyoun Seok;Cho, Yu Ji;Jeong, Yi Yeong;Lee, Jong Deok;Hwang, Young Sil
    • Tuberculosis and Respiratory Diseases
    • /
    • v.60 no.4
    • /
    • pp.419-425
    • /
    • 2006
  • Background : Severe community-acquired pneumonia (CAP) can develop into respiratory failure that requires mechanical ventilation (MV), which is associated with a higher rate of mortality. It was recently reported that a hydrocortisone infusion in severe CAP patients was associated with a significant reduction in the length of the hospital stay and mortality. This study evaluated efficacy of a hydrocortisone infusion for patients with severe CAP requiring MV. Methods : From February 2005 to July 2005, 13 patients (M : F = 10 : 3, mean age: $68.6{\pm}14.1years$), who were diagnosed with severe CAP and required MV, were enrolled in this study. Hydrocortisone was administered as an intravenous 200mg loading bolus, which was followed by an infusion at a rate of 10mg/hour for 7 days. The control group was comprised of patients with severe CAP requiring MV but in whom corticosteroid was not used before study period. The clinical and physiologic parameters on or by day 8 and the outcome in the hydrocortisone infusion group were compared with those in the control group. Results : 1) There was no significant difference in age, gender ratio, SAPS II, SOFA score, temperature, leukocyte count, PaO2/FiO2 (P/F) ratio, the number of patients with P/F ratio < 200, chest radiograph score, lung injury score and catecholamine-dependent septic shock between the hydrocortisone infusion group and control group at day 1. 2) At day 8, the proportion of patients with an improvement in the P/F ratio ${\geq}100$ and the chest radiograph score was significantly higher in the hydrocortisone infusion group than in the control group (61.5% vs. 15.4%, 76.9% vs. 23.1%, p< 0.05). However, there was no significant difference in the other clinical and physiologic parameters. 3). There was no significant difference in the duration of the MV, ICU stay, hospital stay and 10th and 30th day mortality between the two groups. Conclusion : Hydrocortisone infusion for patients with severe CAP requiring invasive mechanical ventilation may be effective in improving the level of oxygenation and the chest radiograph score.

Study on LiFePO4 Composite Cathode Materials to Enhance Thermal Stability of Hybrid Capacitor (하이브리드 커패시터의 열안정성 개선을 위한 LiFePO4 복합양극 소재에 관한 연구)

  • Kwon, Tae-Soon;Park, Ji-Hyun;Kang, Seok-Won;Jeong, Rag-Gyo;Han, Sang-Jin
    • Korean Chemical Engineering Research
    • /
    • v.55 no.2
    • /
    • pp.242-246
    • /
    • 2017
  • The application of composite cathode materials including $LiFePO_4$ (lithium iron phosphate) of olivine crystal structure, which has high thermal stability, were investigated as alternatives for hybrid battery-capacitors with a $LiMn_2O_4$ (spinel crystal structure) cathode, which exhibits decreased performance at high temperatures due to Mn-dissolution. However, these composite cathode materials have been shown to have a reduction in capacity by conducting life cycle experiments in which a $LiFePO_4$/activated carbon cell was charged and discharged between 1.0 V and 2.3 V at two temperatures, $25^{\circ}C$ and $60^{\circ}C$, which caused a degradation of the anode due to the lowered voltage in the anode. To avoid the degradation of the anode, composite cathodes of $LiFePO_4/LiMn_2O_4$ (50:50 wt%), $LiFePO_4$/activated carbon (50:50 wt%) and $LiNi_{1/3}Co_{1/3}Mn_{1/3}O_2$ (50:50 wt%) were prepared and the life cycle experiments were conducted on these cells. The composite cathode including $LiNi_{1/3}Co_{1/3}Mn_{1/3}O_2$ of layered crystal structure showed stable voltage behavior. The discharge capacity retention ratio of $LiNi_{1/3}Co_{1/3}Mn_{1/3}O_2$ was about twice as high as that of a $LiFePO_4/LiMn_2O_4$ cell at thermal stability experiment for a duration of 1,000 hours charged at 2.3 V and a temperature of $80^{\circ}C$.

Inhibitory Effects of Amitriptyline, Sertraline and Chlorpromazine on the Thrombin-induced Aggregation of Platelets (Thrombin성 혈소판응집에 대한 Amitriptyline, Sertraline 및 Chlorpromazine의 억제작용)

  • Choi, Sang-Hyun;Lee, Young-Jae;Shin, Kyung-Ho;Chun, Yeon-Sook;Chun, Boe-Gwun
    • The Korean Journal of Pharmacology
    • /
    • v.31 no.3
    • /
    • pp.299-311
    • /
    • 1995
  • Platelets resemble monoaminergic neurons in several respects, i.e. the uptake of 5-HT and its inhibition, the subcellular storage and release of 5-HT, and the metabolism of aromatic amines brought about by monoamine oxidase. And the 5-HT content of rabbit platelets is well known to be about 40 times higher than that of human platelets. Therefore, this study was carried out to investigate the influences of amitriptyline (AMT) and sertraline (SRT) on the aggregation, contents of signaling second messengers, and protein phosphorylations of rabbit platelets in response to thrombin, 0.25 unit/ml, comparing with those of chlorpromazine (CPZ). Thrombin-induced aggregation was inhibited by SRT $(IC50:4.37{\times}10^{-5}\;M)$, CPZ $(IC50:5.76{\times}10^{-5}\;M)$, and AMT $(IC50:1.15{\times}10^{-4}\;M)$, respectively, and the aggregation by A23187 $(1.0\;{\mu}M)$ or PMA (320 nM) was also inhibited by SRT, CPZ, and AMT. AMT, SRT, and CPZ had little affects on basal contents of platelet $TXB_2$ and $PGE_2$, but all of them inhibited the thrombin-induced increase of $TXB_2$. Thrombin did not change the platelet contents of cAMP and cGMP. CPZ, AMT, and SRT produced the slight decrease of basal cAMP content, and their effects were not affected by thrombin-treatment. But SRT and AMT moderately increased the basal cGMP content, and the cGMP content of thrombin-stimulated platelets was gradually increased by the pretreatment with SRT, AMT, and CPZ. Particularly, the SRT-dependent increase of the cGMP content was notable. Platelet $Ins(1,4,5)P_3$ content was rapidly increased up to a plateau within 10 sec after thrombin-stimulation, AMT, SRT, and CPZ increased the basal $Ins(1,4,5)P_3$ content, and the thrombin-dependent increase was enhanced by pretreatment with CPZ and AMT, but was blunted by SRT. Platelet $[Ca^{2+}]_i$, was rapidly increased up to a peak level within 20 sec after thrombin-stimulation. The increase of $[Ca^{2+}]_i$ was sisnificantly inhibited by AMT, SRT, and CPZ. Thrombin- or PMA-induced phosphorylations of platelet $41{\sim}43\;kDa$ and 20 kDa proteins were significantly inhibited by AMT, SRT, and CPZ. These results suggest that the antiplatelet activities of AMT and CPZ may be considerably attributed to the inhibition of protein kinase C activity, and the activity of SRT may be associated with the inhibitory effect on the thrombin-induced increase of $Ins(1,4,5)P_3$ and the increasing effect on the cGMP content of ptatelets. Therefore, it seems to be evident that AMT and SRT may produce their antidepressant activity, at least, partly through the inhibition of protein kinase C activity or the increase of resting $Ins(1,4,5)P_3$, content and in case of SRT, to a lesser extent, via the increase of cGMP in the brain.