Effect Analysis of Load Shedding Using Wavelet Singular Value Decomposition (부하 탈락 시 Wavelet Transform과 Singular Value Decomposition을 이용한 특성 분석)

  • Gwon, Gi-Hyeon;Kim, Won-Ki;Han, Jun;Kim, Chul-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.51-52
    • /
    • 2011
  • 본 논문에서는 WT(Wavelet Transform)와 SVD(Singular Value Decomposition)기법을 결합한 WSVD(Wavelet Singular Value Decomposition)를 사용하여, 송전계통에서 부하 탈락 시 나타나는 특성 및 외란검출의 유효성을 분석하였다. WSVD 방식을 이용한 외란검출을 모의하기 위해 EMTP-RV를 이용하여 부산 및 경남 일부지역 345kV급 송전계통을 모델링하였고, 이 계통에서 부하 탈락을 모의하였다. WSVD의 계산은 MATLAB을 통해 수행하였으며, 이 결과를 바탕으로 전력계통에서 부하 탈략량의 변화에 따른 특징을 분석하였다

  • PDF

Performance Counter Analysis for Effective Adaptive Load Balancing (효과적인 Adaptive Load Balancing을 위한 성능 지표 분석)

  • Lim, Yoo-Jin;Lee, Won-Q;Han, Young-Tae;Lee, Dong-Hoon;Choi, Eun-Mi
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2002.11a
    • /
    • pp.143-146
    • /
    • 2002
  • 웹 서비스를 제공하는 분산 서버 시스템에서 각 서버의 부하 상태를 파악하여 처리해야 할 부하를 조절하여 주면 서버의 부하가 균등하게 되어 더 나은 성능을 얻을 수 있게 된다. 서버의 부하 상태는 시스템의 자원에 영향을 미치는 여러 가지 요소에 의하여 분석을 할 수 있다. 본 논문에서는 다양한 스트레스 테스트를 통하여 서버의 자원의 고갈을 나타내는 주요 성능 지표들을 변화 상태를 분석하였다. 고려된 성능지표로는 Available Memory 양, Page Read 수, Processor Utilization, Processor Queue Length, 네트웍으로 전달된 Transmitted Bytes, 연결된 Connection 개수이다. 실제로 이중 하나의 요소를 적용시켜서 ALBM (Adaptive Load Balancing Mechanism)을 실행을 하였을 때 일반 LVS Round Robin 보다 성능이 좋은 결과를 낳았다.

  • PDF

Special-Days Load Handling Method using Neural Networks and Regression Models (신경회로망과 회귀모형을 이용한 특수일 부하 처리 기법)

  • 고희석;이세훈;이충식
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.2
    • /
    • pp.98-103
    • /
    • 2002
  • In case of power demand forecasting, the most important problems are to deal with the load of special-days. Accordingly, this paper presents the method that forecasting long (the Lunar New Year, the Full Moon Festival) and short(the Planting Trees Day, the Memorial Day, etc) special-days peak load using neural networks and regression models. long and short special-days peak load forecast by neural networks models uses pattern conversion ratio and four-order orthogonal polynomials regression models. There are using that special-days peak load data during ten years(1985∼1994). In the result of special-days peak load forecasting, forecasting % error shows good results as about 1 ∼2[%] both neural networks models and four-order orthogonal polynomials regression models. Besides, from the result of analysis of adjusted coefficient of determination and F-test, the significance of the are convinced four-order orthogonal polynomials regression models. When the neural networks models are compared with the four-order orthogonal polynomials regression models at a view of the results of special-days peak load forecasting, the neural networks models which uses pattern conversion ratio are more effective on forecasting long special-days peak load. On the other hand, in case of forecasting short special-days peak load, both are valid.

COD Pollutants Load Estimation Schemes in Lake Shihwa and Incheon Coastal Zone (시화호 및 인천연안의 COD 오염부하량 추정기법)

  • Cho Hong-Yeon;Cho Bum-Jun
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.18 no.3
    • /
    • pp.262-267
    • /
    • 2006
  • For the concentration management in COD parameters, it requires the measurement and estimation of the COD pollutants load (hereinafter PL) in the watershed. The estimation method of the PL, however, is provided only based on the BOD parameters. The development of COD PL estimation schemes is expected to execute total PL management in coastal zone and needs to more observation and much time. This study provides COD PL estimation schemes using statistical information about ratio analysis with COD & BOD concentration of rivers and drainages of an industrial complex in Lake Shiwha and Incheon Coastal Zone watershed. The COD PL is computed with ease by multiplying the conversion factor, which is calculated as the sum of the average and 1 to 3 (safety factors) times standard deviation. The conversion factor of Lake Shihwa and Incheon Coastal Zone is estimated as 1.7, 2.3 and 2.9 with respect to the safety factor 1, 2, and 3, respectively.

Analysis on the Characteristics of the Pollutant Load in Chinhae-Masan Bay (진해.마산만 오염부하량의 특성분석)

  • 조홍연;채장원
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.10 no.3
    • /
    • pp.132-140
    • /
    • 1998
  • The quantitative analysis on the pollutants loads (PL) has hardly been carried out and calibration-verification process of the water quality modeling has been conducted under the restricted condition because the observed PL data are not sufficient. In this study, the PLs were measured at the 22 streams and the effluents site in the Masan-Changwon watersheds. The release rates from sediment were also measured at the three points in the Bay. The PLs from the Masan and Changwon cities and from multi-port diffuser(effluents discharge) amount to 80∼90% and 20∼25% of the PL in Chinhae-Masan Bay, respectively. As the amounts of the sediment released pollutants are the same order of the PLs form the watersheds, the pollutants released from the sediment is one of the main factors that might cause the seasonal variation of the water quality, which is degraded in summer and relatively good in winter.

  • PDF

Determination of Ocean Tidal Loading Components at GPS Permanent Stations (GPS 상시관측소에서의 해양조석 부하로 인한 부하성분의 결정)

  • 윤홍식;이동하
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.21 no.4
    • /
    • pp.317-322
    • /
    • 2003
  • This paper have calculated a relative heights of an each station using the data which were observed by GPS permanent stations(Chejudo, Homigoj, Jumunjin, Marado, Palmido, Ulengdo, Youndo) established in Korea. We performed spectrum analysis with a calculated relative heights by CLEAN algorithm. Through these process, we estimated vertical displacement of earth surface by semi-dinural ocean tidal loading components, and compared them with the results which were calculated by improving ocean tide model(NA099jb) for adjacent seas around Japan and Korea. As the result of this study, we determined the ocean tidal loading components with loading effects of $M_2$ and $N_2$, and we noted that the amplitude and the phase lags of ocean tidal loading components from observed GPS data were almost equal to values calculated from ocean tide models. However, the loading components about semi-diurnal tide $S_2$, $K_2$ couldn't estimate because of periods. Also, the diurnal ocean tide loading components were not considered, because the noise level have increased during the diurnal frequency.

Development of Data Aquisition System for Electrical Power Analysis of Electrical Load equipments (전기부하설비의 전력분석을 위한 데이터 획득 시스템의 개발)

  • 이상익;전정채;유대근
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.1
    • /
    • pp.60-66
    • /
    • 2004
  • In order to analyze voltage, current electrical power, harmonic and so on of electrical load equipments, electrical power analysis by real measurement rather than mathematical modeling is necessary, and plan of countermeasure for efficient management, energy frugality and accident prevention of electrical equipments using it is possible Especially, electrical power analysis by real measurement is indispensable in order to consider countermove of harmonic occurred by nonlinear load So, in this paper, we developed DSP(Digital Signal Processor) based low price date aquisition system, and verified it's ability by performing measurement and analysis of electrical power and harmonic in the real power system.

An Analysis of Proxy effect of WWW (웹에서 프락시 서버의 유용성 분석)

  • 장우석
    • Proceedings of the Korea Society for Simulation Conference
    • /
    • 2000.04a
    • /
    • pp.113-118
    • /
    • 2000
  • 웹 사용자의 수가 증가하면서 웹서버에 대한 접속 횟수가 급격히 증가하고 있다. 이것은 망의 부하와 서버의 부하를 증가시켜 웹 사용자가 원하는 정보의 전달을 지연시킨다. 프락시 서버는 이러한 문제를 해결하는 방법으로 서버 파일의 복사본을 클라이언트 가까이 위치시켜 망과 서버의 부하를 감소시킨다. 그러나 웹사용에서 프락시 서버의 도입효과에 대한 구체적인 연구결과가 없으므로 시스템 관리자가 프락시 서버의 도입여부를 결정하기가 힘들다. 본 논문에서는 웹사용 환경에서 프락시 서버의 성능을 평가할 수 있는 모델을 제시하고 시뮬레이션을 통해 이를 분석하고 평가한다.

  • PDF

Analysis of Output Voltage Variation of a Voltage Disturbance Generator with the Variation of Load Power Factor in Voltage Sag Mode (전력변동 발생기의 전압새그 모드 동작시 부하 역률에 따른 출력 전압 변동 해석)

  • Jeong, Hye-Soo;Kim, Hak-Soo;Jung, Jae-Hun;Nho, Eui-Cheol
    • Proceedings of the KIPE Conference
    • /
    • 2015.11a
    • /
    • pp.179-180
    • /
    • 2015
  • 본 논문에서는 변압기 기반 전압변동 발생기의 외란 발생 동작 시 부하단의 전압 특성을 분석하였다. 부하 역률에 따른 전압강하의 차이를 분석하였고 역률이 0.8 지상인 경우 전압강하가 가장 크게 발생함을 실험을 통하여 확인하였다.

  • PDF

The Influence of Inductive Loads on the Power System Voltage (유도부하가 전력계통 부하모선의 전압에 미치는 영향)

  • 조양행;정재길
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.9 no.1
    • /
    • pp.37-46
    • /
    • 1995
  • Along with the recent trend of complexity and long distance transmission in power system, dynamic analysis of stability considering the load characteristics is an important subject. In this paper, the influence of the induction motor loads on the power system voltage is investigated. The influence of the inductive load ratio and the inertia of induction motor on the voltage response of the power system are examined, and in the case of the high percentage of the induction motor load, induction motors in the power system can lead to transient voltage instability even under the system condition such as switching operation. The application of static condenser(SC) to prevent the transient voltage instability is introduced.

  • PDF