• Title/Summary/Keyword: 부피법

Search Result 507, Processing Time 0.034 seconds

Studies on Bread-Baking Properties of Naked Barley Flour and Naked Barley-Wheat Flour Blends - I. Variations of loaf volume of naked barley bread and mixed naked barley-wheat bread prepared by lactic acid method - (쌀보리 및 쌀보리-밀 복합분(複合粉)의 제빵 적성에 관한 연구 - 제 1 보 : 젖산 발효법에 의(依)한 쌀보리 가루 및 복합분(複合粉) 빵의부피(loaf volume)의 변화(變化) -)

  • Rhee, Chul;Bae, Song-Hwan;Yang, Han-Chul
    • Korean Journal of Food Science and Technology
    • /
    • v.14 no.4
    • /
    • pp.370-374
    • /
    • 1982
  • Bread-baking properies of naked barley flour and naked barley-wheat flour blends were investigated, and changes of loaf volume of naked barley bread prepared by straight method and by lactic acid method were observed. Specific loaf volume of naked barley flour bread made by straight method was only 1.11 ml/g bread, while that of barley bread made by lactic acid method was more than 1.50 ml/g bread. No significant increase of loaf volume was noted in mixed naked barley-wheat bread. The increase of loaf volume of barley bread appeared to be due to total titratable acidity of barley dough. Loaf volume of what bread made by lactic acid method decreased sharply as the total titratable acidity of wheat flour dough increased.

  • PDF

Improvement of Accuracy for Determination of Hydrogen Storage of Sieverts Apparatus (부피법을 이용한 수소 저장 성능 평가 장치의 수소 저장량 측정법 개선)

  • Cho, Won-Chul;Han, Sang-Sub;Park, Chu-Sik
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.19 no.1
    • /
    • pp.64-70
    • /
    • 2008
  • This paper briefly discusses the main sources of errors and their solutions for measuring hydrogen uptake from gas phase by the Sieverts technique. Correction of volumetric errors of apparatus, density of hydrogen storage material, estimation of temperature gradient are investigated. Systematic errors and the change of density of the host material according to the pressure have been the subject of much controversy in recent years. We considered the standard ball calibration, temperature gradient distribution, pretreatment of hydrogen storage materials to minimize errors. We could lessen the miscalculations after applying those methods to Equilibrium pressure-composition isotherm data.

Rheological Behaviors of Concentrated Silica Particle Suspensionsprepared by Sol-Gel Method (솔젤법으로 제조된 고농도 실리카 입자 분산계의 유변학적 거동)

  • 양승만
    • The Korean Journal of Rheology
    • /
    • v.10 no.1
    • /
    • pp.24-30
    • /
    • 1998
  • 솔젤법을 이용하여 단분산의 실리카 입자를 제조하고 농도변화에 따른 실리카 분산 액의 유변학적 거동을 해석하였다. 단분산 실리카 입자의 제조는 솔젤법을 이용한 액상반으 으로 제조하였고 입자의 안정화를 위하여 입자표면에 실란커플링제를 코팅하여 유기용매에 서 안정성을 갖도록 하였다. 분산액의 농도에 따른 유변학적 거동을 조사하기 위하여 부피 분율( )이 0.05인 희박 분산계로부터 =0.55의 고농도 분산계를 제조하였다. 솔젤법을 통하 여 단분산 실리카 입자를 성공적으로 제조하였으며 실란커플링제인 ${\gamma}$-methacryloxypropyl triethoxysilane로 입자의 표면을 화학적 방법으로 처리하여 유기용매 상에서 알킬기의 작용 에 의한 hard-sphere'특성을 나타내도록 하였으며 동시에 분산안정성을 유지할수 있었다. 입자 분산계는 =0.25이하의 부피농도에서는 분산용매와 같은 뉴톤거동을 보여주었으며 이 이이상의 농도에서는 비뉴톤거동인 전단담화(shear thinning)현상과 high shear limiting viscosity를 나타내었다. 이결과는 Krieger-Dougherty 식을 따름이 확인되었으며 부피분율 =0.50정도까지도 이식이 잘적용됨을 확인하였다. 부피분율 =0.50 이상의 고농도 입자 분산계 는 급격한 점도의 증가와 함께 전단담화와 전단탁화(shear thickening)현상이 모두 관찰되었 다. 특히 전단탁화를 일으키는 특헝전단변형률(cr)이하의 전단변형률에서는 안정되고 빠른 점성반응(viscous response)을 보여주었으나 특성 전단변형률 부근과 이상의 전단변형률 영 역에서는 매우 불안한 거동이 보여짐을 확인하였다. 그러나 이러한 점도 거동은 가역적이며 전단변형률을 증가시킬때와 감소시킬 때의 유변학적 거동이 거의 일치하였다.

  • PDF

A Quantitative Method for Human Face Volume Using 3D Optical Measurement (3D 측정 기기를 이용한 얼굴의 부피 정량법 연구)

  • Park, Shin-Young;Nam,, Gae-Won;Kim, Seung-Hun;Lee, Hea-Kang;Ahn, Sung-Yeon;Moon, Seong-Joon;Kim, Han-Kon
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.34 no.4
    • /
    • pp.333-338
    • /
    • 2008
  • The evaluation for the visage volume was performed with human and dummy face using PRIMOS $body^{(R)}$. Three researchers measured the dummy face attached different volume of clay (6.6 mL, 13.2 mL, and 19.8 mL). It is identified that the high correlation between measured values and real volume ($R^2=0.99$). The percent (%) of relative standard deviation (RSD) of the data was shown below 10%. In Gage R&R analysis, the percent of contribution, the percent of study variation and distinct categories values were 0.78%, 8.85%, and 15% respectively. Therefore this method was regarded as the good standard condition in aspect of reproducibility and repetitiveness of data. The face volume variation was measured by PRIMOS $body^{(R)}$ on the face in participated 10 healthy Korean women volunteers. Subjects used the product once a day for two weeks as night sleeping pack. After application of the test products, the 3D image data of face were taken 1 and 2 weeks later. We found the face volume was significantly decreased after using products. In conclusion, this novel non-invasive technique was useful in measuring and visualizing alterations in face volume as a consequence of certain treatments. This system will provide a rapid and precise analysis of 3D topographical information for face.

Thermal Analysis of LaNi5 Hydride by Volumetric Method (부피법 자동장치를 이용한 LaNi5 수소화합물의 열분석 장치개발)

  • HAN, JEONG-SEB;KIM, SUNJUNG
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.29 no.1
    • /
    • pp.25-31
    • /
    • 2018
  • To apply Sievert's type apparatus to thermal analysis of hydrogen absorption materials, the dehydrogenation of $LaNi_5$ system was investigated. As the initial wt% of hydrogen was increased from 0.44 to 1.24 wt%, the peak temperature of evolution rate shifted to higher temperature. However, with the initial wt% of hydrogen higher than 0.95 wt%, the peak temperature of evolution rate did not change. As the heating rate was increased, the peak temperature increased; the peak temperatures for heating rates 0.5, 1.0 and 1.5 K/min were 262.2, 264.1, and 265.9 K respectively. The Sievert's type automatic apparatus can be successively applied to the thermal analysis of $LaNi_5$ hydride.

Effects of Various Intracranial Volume Measurements on Hippocampal Volumetry and Modulated Voxel-based Morphometry (두개강의 용적측정법이 해마의 용적측정술과 화소기반 형태계측술에 미치는 영향)

  • Tae, Woo-Suk;Kim, Sam-Soo;Lee, Kang-Uk;Nam, Eui-Cheol
    • Investigative Magnetic Resonance Imaging
    • /
    • v.13 no.1
    • /
    • pp.63-73
    • /
    • 2009
  • Purpose : To investigate the effects of various intracranial volume (ICV) measurement methods on the sensitivity of hippocampal volumetry and modulated voxel-based morphometry (mVBM) in female patients with major depressive disorder (MDD). Materials and Methods : T1 magnetic resonance imaging (MRI) data for 41 female subjects (21 MDD patients, 20 normal subjects) were analyzed. Hippocampal volumes were measured manually, and ICV was measured manually and automatically using the FreeSurfer package. Gray and white matter volumes were measured separately. Results : Manual ICV normalization provided the greatest sensitivity in hippocampal volumetry and mVBM, followed by FreeSurfer ICV, GWMV, and GMV. Manual and FreeSurfer ICVs were similar in normal subjects (p = 0.696), but distinct in MDD patients (p = 0.000002). Manual ICV-corrected total gray matter volume (p = 0.0015) and Manual ICV-corrected bilateral hippocampal volumes (right, p = 0.014; left, p = 0.004) were decreased significantly in MDD patients, but the differences of hippocampal volumes corrected by FreeSurfer ICV, GWMV, or GMV were not significant between two groups (p > 0.05). Only manual ICV-corrected mVBM analysis was significant after correction for multiple comparisons. Conclusion : The method of ICV measurement greatly affects the sensitivity of hippocampal volumetry and mVBM. Manual ICV normalization showed the ability to detect differences between women with and without MDD for both methods.

  • PDF

College Students' Misconception about the Volume Change of Solution during Acid/Base Titration: Partial Molar Volume of Salt (산·염기 적정에서 용액의 부피 변화에 대한 대학생들의 오개념 연구)

  • Jang, Nak Han
    • Journal of Science Education
    • /
    • v.33 no.2
    • /
    • pp.317-320
    • /
    • 2009
  • I investigated Korean college students' conception about the volume change of solution when they detected the equivalence point during acid/base titration experiment using method of volume measurement. According to this study, most college students had a misconception that the volume increment was due to the formation of water by neutralization during acid/base titration. However, this is not enough to explain the volume change, neglecting contribution of a salt in solution. I calculated the partial molar volume of NaCl formed to explain the volume increment of solution during HCl/NaOH neutralization. Comparing the result of experiment with the calculation of partial molar volume, I elucidated that the main effect of volume increment was due to the partial molar volume of NaCl formed during HCl/NaOH neutralization. Here I propose to introduce college students to the concept of partial molar volume of the salt formed to reduce misconception about the volume change of solution during acid/base neutralization.

  • PDF

Effect of Racetrack Pit Depth and Bulk Stress on Far and Near-side Magnetic Flux Leakage at Ferromagnetic Pipeline (강자성 배관 외.내부 벽의 racetrack형 결함깊이와 부피응력이 누설자속에 미치는 영향)

  • Ryu, K.S.;Park, Y.T.;Son, D.;Atherton, D.L.;Clapham, L.
    • Journal of the Korean Magnetics Society
    • /
    • v.13 no.2
    • /
    • pp.70-75
    • /
    • 2003
  • Non-linear anisotropic materials were used to simulate the effects of bulk tensile stress in 3D finite element analysis (FEA). FEA was used to calculate the effects of near and far-side racetrack pit depth and simulated bulk tensile stress on magnetic flux leakage (MFL) signals. The axial and radial MFL signals were depended on near and far-side racetrack pit depth and on the bulk stress, but the circumferential MFL signal was not depended on them. The axial and radial MFL signals increased with greater pit depth and applied bulk stress, but the circumferential MFL signal was scarcely changed.

Study on the Free Volume in Polymer by Positron Annihilation Lifetime Spectroscopy (PALS) (양전자소멸 수명시간 측정을 통한 폴리머소재의 자유부피에 관한 연구)

  • Kim, Yongmin;Shin, Jungki;Kwon, Junhyun
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.6
    • /
    • pp.489-493
    • /
    • 2012
  • Positron Annihilation Lifetime Spectroscopy is a non-destructive technique to study voids and defects in solids by the measurement of gammas from electron-positron annihilation. In this study, we measured the lifetime of CR, EPDM, NBR, all of which are widely used polymer in various fields. A conventional fast-fast coincidence system in KAERI(Korea Atomic Energy Research Institute) has been used to measure the lifetime spectra, Three lifetime components were analyzed from each lifetime spectra. According to Tao-Eldrup model equation, the size and fraction of free-volume were calculated. Mean radius and free volume fraction of CR, EPDM NBR are $0.1217nm^3$(1.9103%), $0.14780nm^3$(5.3147%), $0.1216nm^3$(2.6381%), respectively. Through these measurements, we identified the feasibility of the PAL system for polymer analysis.

The Study of the Hydrogen Absorption and Desorption Reactions of Mg under Near Constant Pressure Using the Sievert's Type Automatic Apparatus (부피법 자동장치를 이용한 유사 일정 압력에서 Mg의 수소 흡수 및 방출 반응에 대한 연구)

  • HAN, JEONG-SEB;KIM, SUNJUNG
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.30 no.1
    • /
    • pp.8-13
    • /
    • 2019
  • In order to apply the Sievert's type automatic apparatus to thermal analysis of hydrogen absorbing materials, the Sievert's type automatic apparatus was modified in my laboratory. In this study, an experiment was conducted to see if hydrogen absorption and desorption reactions are possible under near constant pressure (${\pm}0.05atm$) using this device. The hydrogenation and dehydrogenation of the Mg-H system was investigated. And the program was also modified for the kinetics. It was found that it is possible to measure the hydrogen absorption rate under near constant pressure of Mg by using the modified Sievert's type automatic apparatus at 573 K and 598 K. And using this system, the hydrogen desorption rate of Mg hydride under near constant pressure at 623 K was also measurable. However, since the hydrogen desorption rate of Mg hydride is fast at 648 K, the hydrogen desorption reaction did not proceed within a constant pressure range of $0.15{\pm}0.05atm$.