• 제목/요약/키워드: 부채꼴

Search Result 65, Processing Time 0.029 seconds

Species Diversity and Leaf Form of Ginkgoaleans from the Mesozoic and Cenozoic Strata in Korea (우리나라의 중생대와 신생대 지층에서 산출된 은행류의 종의 다양성과 엽형)

  • Kim, Jong-Heon
    • Journal of the Korean earth science society
    • /
    • v.30 no.1
    • /
    • pp.1-9
    • /
    • 2009
  • This paper conducted the general review of the 6 genera and 22 species of ginkgoaleans known from the Mesozoic and Cenozoic strata of Korea based on the recent palaeontological knowledge. Species diversity and leaf form of the Mesozoic and Cenozoic ginkgoaleans were discussed. Results showed that 4 genera 8 species from the Mesozoic strata and 1 genus and 1 species from the Cenozoic strata were recognized respectively. Laminae of the Mesozoic type of ginkgoaleans were mostly split into narrow lobes, but those of the Cenozoic type were characterized by their fan-shaped simple leaf.

Production of Hydrogen from Methane Using a 3 Phase AC Glidarc Discharge (3상 교류 부채꼴 방전을 이용한 메탄으로부터 수소 생산)

  • Kim, Seong-Cheon;Chun, Young-Nam
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.18 no.2
    • /
    • pp.132-139
    • /
    • 2007
  • Popular techniques for producing synthesis gas by converting methane include steam reforming and catalyst reforming. However, these are high temperature and high pressure processes limited by equipment, cost and difficulty of operation. Low temperature plasma is projected to be a technique that can be used to produce high concentration hydrogen from methane. It is suitable for miniaturization and for application in other technologies. In this research, the effect of changing each of the following variables was studied using an AC Glidarc system that was conceived by the research team: the gas components ratio, the gas flow rate, the catalyst reactor temperature and voltage. Glidarc plasma reformer was consisted of 3 electrodes and an AC power source. And air was added for the partial oxidation reaction of methane. The result showed that as the gas flow rate, the catalyst reactor temperature and the electric power increased, the methane conversion rate and the hydrogen concentration also increased. With $O_2/C$ ratio of 0.45, input flow rate of 4.9 l/min and power supply of 1 kW as the reference condition, the methane conversion rate, the high hydrogen selectivity and the reformer energy density were 69.2%, 36.2% and 35.2% respectively.

Design of CSS3 Polar-Coordinate Layout Module based on Fan Model (부채꼴 모델에 기반한 CSS3 극좌표계 서식 모듈의 설계)

  • Shim, Seung-Min;Lim, Soon-Bum
    • Journal of Korea Multimedia Society
    • /
    • v.22 no.2
    • /
    • pp.299-310
    • /
    • 2019
  • Most web documents are written in Cartesian coordinates, so the study of vertical arrangement of text has been well organized, while the study of circular arrangement is very early. With the recent development of circular display devices, the demand for circular arrangement of texts is increasing. Thus, we proposed a CSS3 extended specification of polar coordinate layout for the circular placement of text. First, we defined the concept of fan model for the text arrangement in polar coordinate which is corresponding to box model in Cartesian coordinate. And, we described new definition on the directions of sentence, paragraph and text orientation in polar coordinate. Based on this new definitions, we developed the extended specification consisting of three parts. A part for setting the fan model, a part for setting directions, and a part for setting typesetting properties. To verify the feasibility of the proposed specification in current web browsers, a preprocessor was developed and sample contents were examined. We compared the code length of the sample contents implemented using other JavaScript library CssWarp.js so as to verify the efficiency of the proposed specification.

An Experimental Study on the Surface Diffusivity of Room Acoustics (실내음향의 확산성에 대한 실험적 연구)

  • Park Kye-Kyun;Haan Chan-Hoon
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • spring
    • /
    • pp.313-318
    • /
    • 1999
  • 본 논문은 1997년 Haan과 Fricke이 발표한 논문1)에서 제시한 확산성의 중요성에 대한 조사에 기초하여 실제홀에서 표면확산성이 실내음향성능에 미치는 영향을 분석해 보았다. 실의 규모가 비슷하고 각기 확산성이 다근 3개의 홀을 선정하였으며, 두 개의 홀은 장방형 평면이며 한 개는 부채꼴평면을 가지고 있다. 각각의 홀에 대해서 한 개의 음원과 8개의 수음점을 설정하여 현장실험과 시뮬레이션을 수행하였고 RT와 SPL의 두 가지 음향평가요소를 사용하여 분석하였다. 분석결과 확산성이 좋을수록 잔향시간이 길어지고 음압레벨이 높아진다.

  • PDF

A Study on the Spray Cooling Characteristics of hot Flat Plates (고온평판의 분무냉각특성에 관한 연구)

  • 윤석훈
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.22 no.6
    • /
    • pp.880-887
    • /
    • 1998
  • In order to study heat transfer characteristics of spray cooling for the purpose of uniform and soft cooling of high temperature surface a series of experiments for a hot horizontal copper flat plate was performed by downflow spray water using flat spray nozzle. Cooling curves were mea-sured under the various experimental conditions of flow rates and temperatures of cooling water Surface temperature surface heat fluxes and heat transfer coefficients of horizontal upward-facing flat surface were calculated with cooling curves measured at each radial positions near the cooling surface by TDMA method. Generally heat transfer characteristics for spray cooling is simi-lar to boiling phenomenon of pool boiling. The minimum heat flux(MHF) appear at the surface temperature of about ${\Delta}Tsat=250^{\circ}C$ and the critical heat flux(CHF) appear at about ${\Delta}Tsat=250^{\circ}C$.

  • PDF

A Study on the High Temperature Region Heat Transfer Coefficients for the Spray Cooling of Hot Flat Plates (평판 분무냉각 시의 고온역 열전달계수에 관한 연구)

  • Yoon, D.H.;Oh, C.;Yoon, S.H.
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.24 no.5
    • /
    • pp.25-32
    • /
    • 2000
  • In this paper, experiments investigating the high-temperature region heat transfer coefficients for the spray cooling of hot flat plates were performed by down spray water using flat spray nozzles. The heat transfer surface is made of copper and is 100mm in length and 40mm in width and 15mm in thickness. The experimental condition of spray are as follows: temperatures of the water droplets are T=20~$80^{\circ}C$ and droplets volume fluxes are D=0.001565~0.010438$m^3/m^2s$. Next, correlating equations for the heat transfer characteristics of spray cooling in the high temperature region are developed from the effects of droplets volume flux and the surface temperature of heat transfer plate.

  • PDF

High Resolution Computerized Tomography System Using the Microfocus X-Ray for Inspection of Small Specimens (소형 물체의 검사를 위한 고해상도 미세 초점 X선 단층 촬영 시스템)

  • Kim, Young-Joo;Koo, Ja-Yong;Lee, Seung-S.;Kim, Whan-W.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.18 no.3
    • /
    • pp.181-190
    • /
    • 1998
  • A computerized tomography system was developed using the X-ray source that has diameter of 5 micrometer. The system is used for the nondestructive testing of specimens with diameter below 20 mm. The convolution back projection algorithm was adopted for the reconstruction of cross sectional image, and the shape of the X-ray beam was let parallel beam or fan beam to compare each resultant image. Our CT system was constructed to operate based on the personal computer. The sectional images of the fabricated specimens were reconstructed and analyzed. The reconstructed images well coincided with real images taken with optical microscope and gave us enough reports on the defects in the ceramic specimen. The resolution of the system regarded as about $20{\sim}30$ micrometers.

  • PDF

The Yield-Line Analysis of Reinforced Concrete Slabs Subjected to Loads of Hydrostatical Type (정수압(靜水壓) 형태(形態)의 하중(荷重)을 받는 철근(鐵筋)콘크리트 슬래브의 강복선해석(降伏線解析))

  • Oh, Jue Won;Lee, Kyu Wan
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.4 no.4
    • /
    • pp.37-48
    • /
    • 1984
  • The yield-line analysis is used for earring out the limit analysis of reinforced concrete slabs which are for example like those of vertical walls of tanks subjected to the loads of hydrostatical type. It is considered both isotropic and orthotropic reinforcement using the coefficient of orthotropy with different edge conditions. The yield-line analysis is carried out by using the vertical work method and four collapse mechanisms including the fan mechanisms which is more realistic than over diagonal mechanisms is considered. It is found that the fan mechanisms are more complicated than ever simple diagonal mechanisms which have used for the orthotropically reinforced concrete slabs subjected to hydrostatic pressures. Especially Horton's study is extended in this study, and they are formulated to the constrained multi-variables nonlinear optimization problems, which are solved by the Rosen-Brock Hillclimb Procedure Program and are more critical.

  • PDF

Dose Distributions in a Shielded Vaginal Cylinder using a HDR Co-60 Source (고선량 Co-60 선원이용시 차폐된 질 원주기구의 영향)

  • 김진기;김정수;김형진;권형철;강정구
    • Progress in Medical Physics
    • /
    • v.8 no.1
    • /
    • pp.37-45
    • /
    • 1997
  • The present work is determine to the dose distribution reduced by the insertion of a shielded into a vaginal cylinder around a $\^$60/CO source in brachytherapy, and to the source calibration. It was investigated by measuring the relative dose around a 2.5cm diameter shielded vaginal cylinder in a polystyrene phantom by use of a ionization chamber. Measurements were made with the cylinder unshielded and 0.55cm thick 90$^{\circ}C$ lead shields inserted. Also, the dose distribution compared measurement value with calculation value according to the device manufacturer and the multiple-divided dose tables. A reduction in dose was observed on the unshielded side of the cylinder which increased with distance from the source and it does 4.4% within 1cm from the surface of the cylinder. On the shielded side of the cylinder, the dose at the surface is reduced to about 20.4% of its value without the shield. The effective attenuation factor entered for the 90$^{\circ}C$ lead shielded cylinder was average 0.2 in a $\^$60/CO moving source. In comparision with the dose calculation mathods, the multiple-divided dose tables are difference less than ${\pm}$4.1% with measured data in a $\^$60/Co source.

  • PDF

Disk Sector Antenna fed by CPW for UWB Communications (UWB 통신용 CPW 급전 디스크 섹터 안테나)

  • Lim, Jung-Hyun;Lee, Min-Soo;Yang, Doo-Yeong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.2
    • /
    • pp.303-312
    • /
    • 2009
  • In this paper, we design and fabricate a disk sector antenna fed by CPW fur UWB communications. Also, we insert a rectangular slit on the arc-edge of the disk sector antenna. Then, the antenna has the directivity of E-면. In order to design the antenna, the input impedance is matched with the feed line of $50{\Omega}$ as varying the physical antenna parameters, which are the radius, the flare angle of disk sector, the length of ground, and the length of ground comer near by feed tine. Dimension of the antenna designed for UWB communication is $72mm{\times}26mm$ and bandwidth through computer simulation is $3{\sim}13GHz$. From the measured results, the bandwidth is $1.98{\sim}11GHz$. Return loss and gain of the fabricated antenna are -50.38dB, 1.34dBi at 3.5GHz, -12.27dB, 3.35dBi at 5.5GHz, -23.2dB, 3.8dBi at 8GHz and -16.17dB, 5.2dBi at 10GHz, respectively.