• 제목/요약/키워드: 부착상태

검색결과 965건 처리시간 0.026초

Effect of Water-Containing Conditions on Concrete Substrates on Defects of Polyurethane-based Waterproofing Materials (콘크리트 바탕면의 함수조건이 폴리 우레탄계 방수재 하자에 미치는 영향)

  • Lee, Gun-Cheol;Kim, Jae-Yeob;Kim, Young-Min;Hong, Sung-Rok;Kim, Young-Sam;Shin, Hong-Chol
    • Journal of the Korea Institute of Building Construction
    • /
    • 제23권1호
    • /
    • pp.1-9
    • /
    • 2023
  • This study is to analyze the cause of the defects in polyurethane waterproofing, a material commonly used on the roof of buildings, and to determine if it has a relation with the curing conditions of humidity and temperature and the moisture content of the base structure. As a result, it was confirmed that the waterproofing coating did not adhere when the moisture content of the base plate was 10% or more. When the temperature and humidity conditions were 20℃ and 80%RH, none of the properties deteriorate but when the temperature was 40℃, 60%RH, air bubbles were formed on the surface, and at 40℃ and 80%RH, the basic properties of the dry coating film were less than the KS F 3211 performance standard.

Structural Capacity of RC Beam Retrofitted by CFS with Bond Loss (탄소섬유로 휨보강된 RC 보의 부착 손실에 대한 거동 특성)

  • Seo, Soo-Yeon;Yun, Hyun-Do;Choi, Ki-Bong
    • Journal of the Korea Concrete Institute
    • /
    • 제19권6호
    • /
    • pp.795-802
    • /
    • 2007
  • Recently, various strengthening methods using carbon fiber sheets (CFS) have been developed for the rehabilitation of structures and applied to the concrete member. However, still research need arises in order to verify the structural capacity of RC member which experienced bond loss between concrete and CFS after strengthening. This is because previous research has focused on the development of design process and evaluation of structural capacity only for retrofit. The appearance of this loss may be initiated at just after retrofit construction. And it will be more serious when the layer number of CFS increases. In order to minimize above mistake in retrofit design using CFS, more exact evaluation process to predict the bond loss of CFS is required. The objective of this research is to study the variation of flexural structural capacity of beam which has experienced bond loss after strengthening using CFS. Experimental and analytical study are performed and evaluation of the previous formula is conducted. Test result showed that the significant strength deterioration was not found until the bond loss of 20%. Overall structural behavior of the beams can be predicted by nonlinear sectional analysis.

Seasonal Changes of the Phytoplankton and the Periphyton Community at the Suer Stream in Kwangyang (전남 광양의 수어천 수역에 있어서 식물플랑크톤과 부착조류 군집의 계절적 변화)

  • Yoon, Sook-Kyung;Lee, Kyung
    • Korean Journal of Ecology and Environment
    • /
    • 제33권1호통권89호
    • /
    • pp.38-50
    • /
    • 2000
  • Seasonal changes of the phytoplankton and the periphyton community were investigated from August 1998 to April 1999 at five stations at the Suer stream in Kwangyang. A total of 112 species of phytoplankton were identified. Of those, the diatoms were present at all stations but the green algae, the bluegreen algae, and the dioflagellates were present at Station 4 and Station 5 more frequently than the other stations. The phytoplankton standing crops varied from 10,100 cells/1 at Station 4 in April 1999 to 1,489,100 cells/1 at Station 4 in October 1998. The seasonal variation patterns of phytoplankton standing crops were different among stations as well as the pattern of presence. The dominant species were as follows: Achnanthes minutissima, Aulacoseira distans v. alpigena, Cocconeis placentula v. lineata, Cymbella minuta, C. silesiaca, Fragilaria arcus v. recta, Peridinium cinctum, Rhizosofenia longiseta, Synedra rumpens and filamentous algae. Of those, Achnanthes minutissima, Rhizosolenia longiseta, Synedra rumpens and filamentous algae showed the highest rate of occupation in the phytoplankton standing crops during the investigated periods. A total of 99 species of periphyton were identified. Among those, the diatoms of the periphyton community were observed frequently rather than those of the phytoplankton community. The ecological indicator values showed ${\bate}$-mesosaprobous in saprobity and was close to eutraphentic in trophic state. There were no considerable differences between the ecological indicator values by planktonic diatoms and periphytic diatoms.

  • PDF

Suggestion of Flexural Strengthening Ratio of NSM Strengthened Concrete Railroad Bridge based on Probability and Reliability (확률.신뢰도에 기초한 표면매립보강(NSM) 콘크리트 철도교의 휨보강비 산정)

  • Oh, Hong-Seob;Sim, Jong-Sung;Ju, Min-Kwan;Lee, Ki-Hong;Park, Ji-Soo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 한국콘크리트학회 2008년도 추계 학술발표회 제20권2호
    • /
    • pp.121-124
    • /
    • 2008
  • The purpose of this study is to evaluate the critical strengthening ratio of concrete railroad bridge strengthened with NSM using CFRP plate. The railroad bridge is usually under vibration and impact in service state. Therefore, it is important that the effective strengthening performance must be exhibited under the service loading is acted. To widely apply the NSM method for the concrete railroad bridge in field, it needs that reasonable strengthening parameter such as strengthening ratio has to be investigated and evaluated when the strengthening design is conducted. In this study, to suggest more reasonable strengthening ratio, material and geometrical uncertainty was considered and applied by Monte Carlo Simulation (MSC) technique. Lastly, the critical strengthening ratio of concrete railroad bridge strengthened with NSM using CFRP plate was evaluated by using the limit state function with the target reliability index.

  • PDF

An Experimental Study on the Shear Strength of Chemical Anchors Embedded into Non Cracking Plain Concrete (비균열 무근콘크리트에 매입된 케미컬 앵커의 전단내력에 관한 실험적 연구)

  • Seo, Seong-Yeon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • 제21권4호
    • /
    • pp.21-29
    • /
    • 2017
  • The use of post installed anchors with adhesive type has lately been increasing when it is necessary to repair, reinforce, or remodel structures. This method provides flexibility and simplicity for construction of structural members that require adhering or fixing. Meanwhile, strength evaluation of anchors with expansion type among post installed anchors systems has nearly reached setting up stage like design code through continual experimental studies for the last ten years, but analyses or experimental studies on anchor system with adhesive type are not yet sufficient. Accordingly, the designers and builders of korea depend on foreign design codes since there are no exact domestic design code they could credit. In this study, the objectives are investigating the effects on adhesive strength of anchors embedded into plain concrete by shear experiments of anchors with variables such as edge distance, anchor interval, and load direction and supplying basic data for enactment of domestic design code.

Implant overdenture treatment using Locator attachment system on edentulous patient (무치악 환자에서 로케이터 부착장치를 이용한 임플란트 피개의치 수복 증례)

  • Kim, Soo-Yeop;Shin, Soo-Yeon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • 제30권2호
    • /
    • pp.176-183
    • /
    • 2014
  • Severely absorbed edentulous ridge cannot bear mechanical stress, causes undesired transformation of oral environment and makes patients difficult to adapt to dentures. Nowadays implant overdenture can be a treatment of choice in order to relieve patients' discomfort and improve stability and retention of the denture. Placement of implant on maxilla is difficult because of its bone quality and anatomic structure. It also has wide supportive tissue and convenience of border sealing, which provides sufficient support and stabilization with conventional complete denture. Mandible, on the other hand, is difficult to obtain sufficient support, retention and stabilization with conventional complete denture. Therefore, implant overdenture is recommended on mandible. Locator attachment has been improved for convenience of use and male parts of various retention enabled it to replace ball type attachment clinically. In this study, we restored maxillary arch with conventional denture, and mandibular arch with implant and tissue-supported overdenture and Locator attachment system.

An Experimental Study on the Bond Strength of Polymer-Modified Mortars (폴리머 시멘트 모르타르의 부착강도에 대한 실험적 연구)

  • Park, Hun-Il;Song, Ki-Min;Park, Sang-Sun;Sin, Hong-Chul;Sin, Ju-Jae;Kim, Young-Kun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 한국콘크리트학회 2008년도 춘계 학술발표회 제20권1호
    • /
    • pp.629-632
    • /
    • 2008
  • In the concrete repairing industry, it's very significant to apply adequate repair materials and construction method in order to extend service life of deteriorated concrete structure efficiently. also, adequate diagnosis of deteriorated structure's status should be involved. This paper describes an investigation of bond strength of polymer modified mortar applied both old deteriorated concrete surface substrate and well cured new concretes. The purpose of this investigation is comparing how much the tensile bond strength on construction site is different from laboratory test results. in the results of investigation, most of sample tested in laboratory is in compliance with KS F 4042's specification. and most of results of construction site are not in compliance with the specification cause of low tensile strength of concrete's surface.

  • PDF

Evaluation of Anti-Corrosion Performance of FRP Hybrid Bar with Notch in GGBFS Concrete (GGBFS 콘크리트에 매립된 Notch를 가진 FRP Hybrid Bar의 부식저항성 평가)

  • Oh, Kyeong-Seok;Park, Ki-Tae;Kwon, Seung-Jun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • 제20권4호
    • /
    • pp.51-58
    • /
    • 2016
  • Concrete structure is a construction material with durability and cost-benefit, however the corrosion in embedded steel causes a critical problem in structural safety. This paper presents an evaluation of chloride resistance and pull-off performance with various corrosion level. For the work, OPC(Ordinary Portland Cement) concrete and GGBFS(Ground Granulated Blast Furnace Slag) concrete are prepared with normal steel. Artificially notch induced FRP Hybrid Bar is also prepared and embedded in OPC concrete and accelerated corrosion test is performed. Through the test, FRP Hybrid Bar with notch is evaluated to have insignificant effect on pull-off capacity when corroded steel shows only 21% level of pull-off capacity. Furthermore GGBFS concrete with normal steel shows over 70% level of pull-off capacity due to reduced corrosion currency.

Active Warehouse Condition Management System based on RFID/USN Security (보안을 고려한 RFID/USN 기반의 능동형 창고 상태 관리 시스템)

  • John, Young-Jun;Choi, Yong-Sik;Park, Sang-Hyun;Han, Soo;Shin, Seung-Ho
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 한국정보과학회 2006년도 가을 학술발표논문집 Vol.33 No.2 (D)
    • /
    • pp.122-127
    • /
    • 2006
  • RFID/USN 은 유비쿼터스 사회의 중요한 기반 인프라로서 고려되고 있다. 또한 다양한 연구를 통해 실용적인 접목이 시도 되고 있다. 특히 물류 시스템에서 물류의 입출 재고와 상태 관리를 위한 연구가 진행 중에 있으며 이는 물품 보관 단위인 파렛트(Pallet) 에 RFID 태그를 부착하여 입/출고시의 물품을 식별하고, Zigbee 무선 통신기능을 가진 센서 모듈에 의해 물품의 환경 상태 정보를 파악하는 형태로 이루어진다. 본 논문은 RFID/ USN 기반의 창고 상태 관리 시스템에서 상태정보 습득 과정의 보안적용을 위한 시스템을 구성을 주된 목적으로 한다. 부가적으로 상태정보 습득에 사용되는 이동형 단말장치의 기능에 대해서 제안한다. 창고 내에 배치되는 RFID 와 센서노드간의 적용 관계 또한 정의한다. 결과적으로 본 논문은 의사판단의 주체인 현장 관리자에 적절한 제어 정보의 제공과 센서의 동작을 제어하기 위한 RFID tag 보안 접근, 그리고 센서 노드 자체의 생존성 이라는 세 가지 관점의 절충점을 찾기 위한 시도로서 설계하였다.

  • PDF

FFT and AR Coefficient Analysis of Vibration Signal in Mold Transformer (몰드변압기 진동신호의 FFT 및 시계열 계수 분석)

  • 정용기;정종욱;김재철;곽희로
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • 제12권4호
    • /
    • pp.136-145
    • /
    • 1998
  • This paper describes the FFT and coefficient analysis of vibration signals for preventive diagnosis of a mold transformer at normal and abnormal state. Varying applied voltage, loading current and temperature as control variables for he experiment, measurement variables such as magnitude of vibration signals, frequency spectrum and time series coefficient were analyzed. The vibration signals by variation of control variables were measured by acceleration sensor adhered on the surface of winding and core, and measurement variables were calculated using dat acquisition system. After analyzing the normal state, the structural distortion was also simulated. The vibration signals at abnormal state were measured by the same control variables variation as the normal state. As a result, vibration signals between normal and abnormal state could be distinguished by comparison of the perpendicular and horizontal vibration signal.

  • PDF