• Title/Summary/Keyword: 부착상태

Search Result 965, Processing Time 0.021 seconds

A Study on Bond Strength of Cement-Based Filler and Flexural Strength of RC Beam Strengthened with GFRP by Filler Thickness (시멘트계 충진제의 접착 성능 및 보강 두께에 따른 GFRP 보강 RC보의 휨 성능에 대한 연구)

  • Choi, Ha-Jin;Choi, Young-Woong;Park, Jong-Chul;Jung, Si-Young;Choi, Oan-Chul
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.5
    • /
    • pp.144-152
    • /
    • 2010
  • In this study, cement-based filler is used as an adhesive instead of organic adhesive, epoxy because there were problems under wet condition. First, the bond strength of cement-based filler was measured and the result was satisfied with KS F 4716. However, in case of wet condition, bond strength of epoxy adhesive decreased $0.73N/mm^2$ in 7 days and $0.84N/mm^2$ in 14 days from pilot test. This implies that there would be a problem on reinforced concrete structure in wet condition, such as tunnel and sewage box. In the second experiment, the flexural strength of RC beams with GFRP using different thickness of cement-based filler was investigated, and the result was indicated 113%, 66%, 75% increase in 10mm, 20mm, 30mm thickness, respectively. From the result, it was known that 10mm filler thickness produces stable bond performance.

Bond Performance of GFRP Rebar to Concrete at High Temperature (콘크리트의 내부 온도에 따른 GFRP Rebar의 부착특성에 관한 연구)

  • Sim, Jong-Sung;Moon, Doo-Yong;Kang, Tea-Sung;Kim, Yong-Jae;Kim, Hyun-Joong
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2010.05a
    • /
    • pp.49-50
    • /
    • 2010
  • This study focuses on the bond performance of ribbed type of GFRP rebar to concrete at high temperature and discusses the results of pullout test. Pullout tests of ribbed type of GFRP rebars embedded in concrete were conducted to obtain an accurate bond stress-slip curves and also to closely observe the state of the surface of pulled-out rebars at failure. The effect of temperature on the bond strength is mainly discussed in this paper. Relatively high bond strength was seen in the control specimen which is exposed to room temperature. But, as the internal temperature increases, the bond strength decreases.

  • PDF

The Relationship between Life Style and Periodontal Health Status (생활습관과 치주건강상태의 관련성)

  • Ryu, Hae-Gyum;Lee, Jung-Hwa
    • Journal of dental hygiene science
    • /
    • v.13 no.4
    • /
    • pp.418-425
    • /
    • 2013
  • This study was investigated in order to provide basic data for prevention of periodontal disease and maintenance through proper lifestyle by finding the relevance of periodontal health with lifestyle habits. Data were collected from total of 326 subjects in their forties and fifties by using questionnaire and examination of periodontal health status. Results were analyzed by using IBM SPSS Statistics 19.0. The smoking status were statistically significant to gingival index (p<0.01), pocket depth (p<0.001), and clinical attachment loss (p<0.001). Smoking amount per day were statistically significant to gingival index (p<0.05), pocket depth (p<0.01), and clinical attachment loss (p<0.001). Duration of smoking were statistically significant to gingival index (p<0.05), pocket depth (p<0.01), and clinical attachment loss (p<0.001). Drinking cycle were statistically significant to gingival index (p<0.05), and clinical attachment loss (p<0.05). It is investigated that smoking (p<0.05) influence on clinical attachment loss. Dental care institute needs to make patients be aware of the fact that excessive smoking and drinking affect the periodontal health status for prevention of periodontal disease and maintenance of oral health. Therefore systematic educational programs to stop smoking and drinking should be prepared.

Real Time Bridge Condition Monitoring Using Wireless Sensor Network (무선 네트워크를 이용한 실시간 교량 상태 계측)

  • Chae, Myung-Jin;Yoo, Hyun-Seok;Kim, Jeong-Ryeol;Park, Jae-Woo;Cho, Moon-Young
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2006.11a
    • /
    • pp.194-197
    • /
    • 2006
  • 교량의 고성능화, 고효율화 및 센서기술의 발전에 따라서 최근의 장대교량의 경우 교량에 각종 센서를 부착하여 상태를 실시간으로 교량의 상태를 계측하는 시스템이 개발되어 사용되고 있다. 하지만, 기존의 센서와 데이터 로거를 이용한 계측시스템은 높은 설치비가 요구되며 센서 설치비의 50%이상이 통신케이블에 관련된 비용이다. 본 논문에서는 설치비용 절감과 저렴한 유지관리비용 및 센서의 추가 및 교체가 손쉬운 무선기반의 계측시스템 개발에 관하여 논하고자 한다. 교량의 부재에 부착되어있는 센서들 사이 근거리 무선통신은 ZigBee를 이용한 무선통신네트워크를 구성하였으며, 교량과 교량관리소 사이의 장거리 통신에는 국내 휴대전화에 사용되고 있는 CDMA 통신망을 이용하여 데이터를 전송하는 방식을 취하고 있다.

  • PDF

Experimental Verification on the Structural Safety of Cantilever Beam Connected with Post-installed Adhesive Anchor Bolts (부착식 후설치 앵커로 연결된 내민보의 구조 안전성에 대한 실험적 평가)

  • Oh, Hong-Seob;Park, Sung-Rak
    • Journal of the Korea Concrete Institute
    • /
    • v.23 no.4
    • /
    • pp.529-536
    • /
    • 2011
  • Recently, there has been a growing interest in expanded sidewalks for existing bridges. The cantilever beam system applied to expanded sidewalks for existing bridges are connected with the concrete structure by adhesive anchor bolts. However, the extended sidewalks are currently constructed without standardized regulations, which lead to excessive design of the beam spacing and installation and the construction difficulties due to the excessive over-weight. Moreover, there is only limited analysis and experiment data on the post-installed adhesive anchor bolts, so the excessive number of bolts is used for the connection. This paper deals with a method to increase the effectiveness of beam sections and anchor bolts geometry for expanded sidewalk of existing bridge. The study results showed that the failure of cantilever beam connected by adhesive anchor bolts was dominated by bond failure of interface between concrete and bolt. Also, the results indicated the possibilities of improving serviceability as well as safety of the sidewalks by changing of beam section and prestressing the bolts.

Properties of Mortar Adhered to the Recycled Coarse Aggregate in Cement Paste (시멘트풀 속에서의 순환굵은골재 부착모르타르의 성상변화에 관한 연구)

  • Moon, Dae-Joong;Choi, Jae-Jin
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.6 no.1
    • /
    • pp.95-102
    • /
    • 2011
  • Vicker's hardness and pore size distribution of mortar adhered to the recycled coarse aggregate were tested according to the strength level of original concrete of recycled coarse aggregate to find the change of mortar adhered to the recycled coarse aggregate in cement paste. The strength levels of original concrete of recycled coarse aggregate were 25.5MPa, 41.7MPa and 60.1MPa and the aggregates were used at the state of saturated surface dry condition and oven dry condition. The results of this experimentation indicated that the mean value of Vicker's hardness was increased according to age and strength of original concrete of recycled aggregate. Porosity of $100nm{\sim}10{\mu}m$ size was reduced and porosity of 6nm~100nm size was increased in cement paste.

  • PDF

Hysteretic Damage Model for Reinforced Concrete Joints Considering Bond-Slip (부착-슬립을 고려한 철근콘크리트 접합부의 이력 손상 모델 개발)

  • Kim, Do-Yeon;Choi, In-Kil
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.4A
    • /
    • pp.517-528
    • /
    • 2008
  • This paper presents a hysteretic damage model for reinforced concrete (RC) joints that explicitly accounts for the bond-slip between the reinforcing bars and the surrounding concrete. A frame element whose displacement fields for the concrete and the reinforcing bars are different to permit slip is developed. From the fiber section concept, compatibility equations for concrete, rebar, and bond are defined. Modification of the hysteretic stress-strain curve of steel is conducted for partial unloading and reloading conditions. Local bond stress-slip relations for monotonic loads are updated at each slip reversal according to the damage factor. The numerical applications of the reinforcing bar embedded in the confined concrete block, the RC column anchored in the foundation, and the RC beam-column subassemblage validate the model accuracy and show how including the effects of bond-slip leads to a good assessment of the amount of energy dissipation during loading histories.

분홍성게 치성게 사육 파판상의 부착규조류 천이

  • 김재우;좌종헌;정상철;이준백
    • Proceedings of the Korean Aquaculture Society Conference
    • /
    • 2003.10a
    • /
    • pp.97-97
    • /
    • 2003
  • 유용 수산생물인 전복, 소라, 성게 등 무척추동물의 종묘생산에 있어 부착 규조류는 수서 생태계의 일차 생산자로서 유생의 변태와 변태 후의 초기 먹이생물로 활용되고 있으며 최근에는 단일 부착규조류의 실내 배양을 통해 유용 수산생물 종묘의 대량 생산을 유도하고 있다. 부착규조류의 생물량 및 종 조성에 따라 이들 조식동물의 성장과 먹이 효율성에 커다란 영향을 끼친다. 이 연구는 종묘생산의 환경 조건과 동일한 현장에서 유수식 수조에 투명 플라스틱 부착파판(30$\times$40cm)을 설치하여 1997년 10월부터 1999년 4월까지 실내수조에 설치한 부착파판을 10일 간격으로 회수하여 부착된 규조류의 생물량과 환경적 특성을 조사하였다. 실험기간 동안 자연광을 55~75% 차단한 상태에서 실험을 진행하였고 수온과 염분은 각각 14.1$^{\circ}C$~28.6$^{\circ}C$와 32.5$\textperthousand$~35.3$\textperthousand$의 범위를 보였다. 실험기간 동안 부착규조류의 총 출현종수는 27종(17속 25종 2미동정종)으로 중심규조류(centric diatom)가 4종 그리고 우상규조류(pennate diatom)가 23종이었다. 현존량의 30% 이상을 점유하는 부착 규조류들은 Bacillaria paxillifera, Cocconeis scutellum, Diatoma hyalina, Navicula mollis, Nitzschia sp., Synedra tabulta 등 6종이 우점하였다. 부착규조류의 현존량은 2.5$\times$$10^3$~ 5.0$\times$$10^{5}$ cells $cm^{-2}$ 의 분포 범위로 1999년 4월에 가장 높고 1997년 10월에 가장 낮았다. Chlorophyll $\alpha$량 ($\mu\textrm{g}$ chl $\alpha$ $cm^{-2}$)은 0.02 ~ 1.72 $\mu\textrm{g}$ chi $\alpha$ $cm^{-2}$의 범위로써 부착규조류의 현존량과 유사한 분포 특성을 보였다. 유수식 실내수조에 부착된 부착규조류의 부착 형태, 우점종과 현존량은 배양 시기에 따라 종간 특이성을 보였다.다.

  • PDF

Experimental Study on Bond Strength between Carbon Fiber Sheet and Concrete (탄소섬유쉬트와 콘크리트의 부착강도 실험연구)

  • 유영찬;최기선;최근도;이한승;김긍환
    • Journal of the Korea Concrete Institute
    • /
    • v.13 no.2
    • /
    • pp.168-174
    • /
    • 2001
  • Carbon fiber sheet(CFS) has been widely used for strengthening of the concrete building structures due to its excellent physical properties such as high strength, light weight and high durability. Bond strength or behavior, on the other hands, between carbon fiber sheet and concrete is very important in strengthening the concrete member using CFS. Therefore the bond failure mechanism between CFS and concrete should be fully verified and understood. This study is to investigate the bond strength of CFS to the concrete by the direct pull-out test and the tensile-shear test. In the direct pull-out tests, the bond strength under the various environmental conditions such as curing temperature, surface condition on concrete and water content of concrete are evaluated. Also, the effective bond length, lu and the average bond stress, $\tau$y are examined in the tensile-shear tests. Based on the test results, it is concluded that the curing temperature is the most critical element for the bond strength between CFS and concrete. And, the proper value of lu and $\tau$y is recommended with 15 cm and 9.78∼ 11.88 kgf/$\textrm{cm}^2$ respectively.

Effect of Bonding Layer on Guided Wave Mode Behavior in FRP Plate Bonded on Concrete (FRP 보강판 부착 콘크리트에서 유도초음파 모드 거동에 대한 접착층의 영향)

  • Lee, Yong-Ju;Shin, Sung-Woo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.1
    • /
    • pp.34-40
    • /
    • 2012
  • In this study, effects of bonding agent, e.g. epoxy, on the behavior of fundamental guided wave modes propagated in FRP plate bonded on a concrete, are investigated. Global matrix model of multilayered FRP-epoxy-concrete system was constructed to obtain the velocity and attenuation dispersion curves of the fundamental A0 and S0 modes. Two variables, thickness and elastic modulus of epoxy layer, were considered in the dispersion analysis. It was found that both the thickness and the elastic modulus of epoxy layer greatly affect the phase velocity and attenuation of S0 mode while those are negligible for A0 mode. Based on the results, it was concluded that S0 mode is more effective than A0 mode for bonding condition assessment for FRP plate bonded concrete.