• Title/Summary/Keyword: 부착물

Search Result 1,540, Processing Time 0.032 seconds

A Study on the Performance of Mechanical Pressurizing Equipment(MPE) for Improving Bond Strength of Repair Materials for Concrete Box Structures (콘크리트 박스 구조물용 보수재의 부착강도 향상을 위한 기계식 가압장비(MPE) 성능에 관한 연구)

  • Yu, Hyeong-Sik;Jung, Jee-Seung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.6 no.1
    • /
    • pp.477-483
    • /
    • 2020
  • The rehabilitation methods used in existing concrete box structures rely on the method of attaching the repair material to the section of the structure with a spray equipment. In the case of ceiling or wall parts, the adhesion force to the repair material may be reduced by the gravity and dead load after construction. In subway structures, vibration causes a problem that reduces the initial adhesion. Supplementary measures are needed as the quality of repair varies depending on the worker's proficiency and construction environment. In this study, mechanical pressurization equipment was developed that can apply a certain pressure after construction of a repairwork to solve problems such as reduction of adhesion of repair materials by gravity and variation of repair quality by labor work. To find out the effect of the pressurized equipment, a chamber similar to the field conditions was constructed to measure the attachment strength different from the pressurized condition, the section, and the environmental conditions. The pressurization differed from the other parts, but the adhesion strength of up to 70% was increased.

Spectral Element Analysis for the Electro-Mechanical Admittance of a Piezoelectric Wafer Bonded on a Plate (판구조물에 부착된 압전소자의 전기역학적 어드미턴스 스펙트럼 요소 해석)

  • Kim, Eun-Jin;Shon, Sohn;Park, Hyun-Woo
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2009.04a
    • /
    • pp.239-242
    • /
    • 2009
  • 구조물의 표면에 부착된 압전소자(이하 PZT)의 전기역학적 어드미턴스(Electro-mechanical admittance)는 PZT와 구조물의 상호작용에 의해 발생하는 PZT의 압전효과와 유전성(dielectric)이 결합되어 발생되는 신호이다. 고주파수 대역에서 PZT의 전기역학적 어드미턴스는 구조물의 국부손상에 민감하게 반응하는 것으로 알려져 있다. 실험에서 측정된 PZT의 전기역학적 어드미턴스 분석에 널리 쓰이는 Liang 모델은 구조물을 단자유도계로 단순화하여 구조물의 동적특성이 전기역학적 어드미턴스에 미치는 영향을 정확하게 나타내기 어렵다. 유한요소법을 통해 PZT와 구조물의 상호작용을 해석하면 이러한 문제점을 해결할 수 있다. 그러나 고주파 대역에서 정확한 해석을 위해서는 유한요소망을 조밀하게 구성해야 하므로 많은 계산비용이 수반된다. 이 연구에서는 유한요소법과 비교하여 월등히 적은 계산비용으로 고주파 대역의 동적 응답을 매우 정확하게 모사할 수 있는 스펙트럼 요소법(Spectral Element Method ; 이하 SEM)을 통해 판구조물에 부착된 PZT의 전기-역학적 어드미턴스를 해석한다. 수치 예제 및 실험 예제를 통하여 내민보에 부착된 PZT에서 발생하는 전기-역학적 어드미턴스를 취득하고 이를 SEM해석 결과와 비교한다.

  • PDF

An Experimental Study on Concrete Bond Behavior According to Grid Spacing of CFRP Grid Reinforcement (격자형 CFRP 보강재의 격자간격에 따른 콘크리트 부착거동에 대한 실험적 연구)

  • Noh, Chi-Hoon;Jang, Nag-Seop;Oh, Hongseob
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.6
    • /
    • pp.73-81
    • /
    • 2022
  • Recently, as the service life of structures increased, the load-carrying capacity of deteriorated reinforced concrete, where corrosion of reinforcing bars occurs due to various causes, is frequently decreased. In order to address this problem, many studies on the bond characteristic of FRP (Fiber Reinforced Polymer) bars with corrosion resistance, light weight and high tensile strength have been conducted, however there are not many studies on the bond characteristic of grid-typed CFRP embedded in concrete. Therefore, in order to evaluate the bond characteristics of grid-typed CFRP and its usability as a substitute for steel rebar, a pull-out test is performed using the longitudinal bond length and transverse grid length of the grid-typed CFRP as variables. Through the pull-out test, the bond load-slip curve of the grid-typed CFRP is derived, and the bond behavior is analyzed. The total bond load equation is proposed as the sum of the bond force of the longitudinal bond length and the shear force of the grid in the transverse direction. Also, expressing the area of the bond load-slip curve as total work, the change in dissipated energy with respect to the slip is analyzed to examine the effect of the tranverse grid on the bond force.

Improvement of Damage Localization Performance for CFRP-debonding defects using Piezo-electric Sensors (압전센서 기반 CFRP 부착면 탈락 손상영역 탐색성능 향상)

  • Kim, Ju-Won;Lee, Chang-Gil;Lee, Dong-Hwan;Chang, Ha-Joo;Park, Seung-Hee
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2011.04a
    • /
    • pp.311-314
    • /
    • 2011
  • 최근 콘크리트 구조물의 안전성강화를 위해 탄소섬유 강화 플라스틱(CFRP) 보강 공법이 널리 사용되고 있지만 잘 알려진 바와 같이 CFRP 보강재와 콘크리트 표면사이의 부착면 탈락은 보강재 자체의 손상보다 발생할 확률이 높고 이러한 부착면 탈락은 보강의 효과를 무의미하게 만들기 때문에 구조물 전체의 파괴로 직결될 수 있다. 이에 본 연구에서는 CFRP 부착면 탈락손상을 실시간으로 검색하기 위해 압전센서를 사용하는 구조물 건전성 평가 기술을 적용하였다. 이의 검증을 위해 CFRP로 보강된 콘크리트 보를 제작하였고 3단계로 증가하는 부착면 탈락 손상을 발생시켰다. 손상 증가 단계마다 CFRP 표면에 배열된 압전센서로부터 임피던스와 유도초음파 신호를 계측하였고 손상에 따른 신호변화를 정량화하기 위해 손상지수인 RMSD를 계산하였다. 더 구체적인 부착면 탈락 손상위치 탐색을 위해서 두 가지 계측 기법으로부터 구해진 RMSD 값를 중첩시키는 Superposed RMSD 가 제안되었다. 구해진 Superposed RMSD 값을 사용하여 커브 피팅이 수행되었고 도출된 커브의 최고값에 해당하는 위치값을 찾아 실제 손상위치와 비교함으로써 제안된 기법의 가능성을 검증해 보았다.

  • PDF

Adhesive Shear Strength of Carbon Fiber Sheet (탄소섬유시트의 전단부착강도에 관한 연구)

  • Kim, Yoon-Chil
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.12 no.1
    • /
    • pp.109-116
    • /
    • 2008
  • In order to test the adhesive capacity of carbon fiber sheet, a static loading method for bending-behavior-type beam specimens, cut in half was developed and test was conducted with compressive strength of concrete set as the test parameter. The tests were performed to prescribe adhesive shear strength based upon the result of shear failure as well as verification of testing method. First of all, the test method proved to be reliable in determining the adhesive shear strength. The test result also exhibited two types of variations in adhesive shear strength. Among two types of variations, average and minimum values for adhesive shear strength, relatively stable results, 3.41MPa and 2.11MPa, respectively. Particularity in the adhesive shear strength with respect to compressive shear strength was not found.

Bond Models for GFRP Rebar Embedded in Concrete (GFRP 보강근과 콘크리트 사이의 부착모델에 관한 고찰)

  • You, Young-Jun;Park, Ji-Sun;Park, Young-Hwan;Kim, Hyeong-Yeol
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.10 no.3
    • /
    • pp.143-151
    • /
    • 2006
  • This paper presents the comparison of the goodness-of-fit test of analytical bond models between concrete and steel or GFRP reinforcements. Bond test specimens were prepared in accordance with the CSA codes and the rebars used in the test were steel and two types of commercial GFRP rebar products. Using the test data, a bond model was proposed, and comparison of goodness-of-fit test for existing bond models and proposed bond model was carried out by the least squares method. The result indicates that the proposed bond model has better goodness-of-fit test than the existing ones.

칫솔

  • An, Jeong-Mi
    • The Journal of the Korean dental association
    • /
    • v.37 no.10 s.365
    • /
    • pp.766-771
    • /
    • 1999
  • 칫솔은 치면에 부착된 프라그 등의 부착물을 물리적으로 제거하기에 가장 합리적이고 간편하게 사용할 수 있도록 설계된 구강청소용구이다. 가장 흔하지만 무심코 지나치기 쉬운 칫솔 칫솔의 역사와 칫솔의 종류, 1300억에 이르는 칫솔시장을 분석해 본다.

  • PDF

Assessment of the Resistance Performance of Hull Appendages Attached to Fishing Vessels Using CFD (CFD에 의한 어선 선체 부가물의 저항성능 평가)

  • Park, Dong-Woo
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.24 no.2
    • /
    • pp.267-274
    • /
    • 2018
  • A variety of appendages are attached to coastal and offshore fishing boats to improve stability during navigation or fishing operations (stability performance and roll reduction). These appendages are generally classified into three types, which are shown in Fig. 1. The numerical calculations were conducted for the following eight cases: one case of a bare hull, three cases where a single appendage attached, three cases of a pair of appendages attached, and one case where all three appendages were attached. Table 1 presents the main dimensions of the bare hull and Table 2 describes the main dimensions of the three appendages. The fluid dynamic performance with regard to the three hull appendages was evaluated via CFD for the following cases: each of the appendages attached independently, a pair of appendages attached, and all three appendages attached simultaneously. The No. 1 appendage showed that pressure resistance was proportionally greater than friction resistances. Both Nos. 2 and 3 appendages showed comparable levels of pressure and friction resistances. The correlation between appendages was minimal in the case of pairs and Comparing the cases of the No. 2 appendage attached and all appendages attached, at 11 kn, the EHP showed an difference of 9 %.

Estimation of Water Purification Ability with Applying Porous Concrete to Weir and Riverbed Materials (다공성 콘크리트의 보 및 하상재료 적용에 따른 하천 수질정화 능력 평가)

  • Choi, I-Song;Kim, Jin-Hong;Choi, Gye-Woon;Oh, Jong-Min
    • Journal of Korea Water Resources Association
    • /
    • v.36 no.6
    • /
    • pp.1013-1023
    • /
    • 2003
  • This study was performed to improve water quality of stream by applying hydraulic structures (weir and river bed material) made of porous concrete. The physical and chemical characteristics of porous concrete were measured to estimate application possibility of it in hydraulic structures and it was considered as a proper material for the hydraulic structures. In the results of comparison for the component of matters attached on the hydraulic structures made of porous and ordinary concrete, DW (dry weight) amount attached on porous concrete was 1.6 times higher than that on ordinary concrete under the condition of the same flow rate but influence by flow rate (difference of 10 times) was not shown. Therefore, we could understand that the material of media was more important in DW amount than flow rate. The rate of AFDM (ash free dry mass) to DW also was more at porous concrete than at ordinary concrete. Especially, the high rates of nitrogen and phosphorous in matters attached on porous concrete verify that they were removed by assimilation, adsorption and metabolism of periphyton. The removal percentage of SS, BOD, COD, T-N and T-P by hydraulic structures applying porous concrete compared with ordinary concrete was increased by 34.6%, 36.9%, 33.9%, 18.3% and 21.6%, respectively. Therefore, applying porous concrete to hydraulic structure is expected to contribute to improvement of stream water quality.

Insulation Characteristics of Contaminated Polymeric Insulators in the Field Condition (옥외용 폴리머 절연물의 표면 오손에 따른 절연특성 연구)

  • Lee, Byung-Sung;Park, Chul-Bae;Park, Yung-Woo;Chun, Sung-Nam
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.2019-2020
    • /
    • 2008
  • 옥외에서 폴리머 애자의 사용량이 급격하게 증가하는 이유는 자기제 애자에 비해 경량이면서 오손특성이 우수하다는 장점 때문이다. 약 10년 전 국내 배전선로에 설치된 EPDM(Ethylene propylene diene monomer) 재질의 폴리머 현수애자의 섬락고장이 있었다. 폴리머 애자는 재질 특성상 사용시간에 따라 표면 열화가 진행되고, 표면의 절연저항이 감소하여 누설전류가 증가하게 된다. 표면 섬락고장을 유발하는 누설전류는 절연물 표면 상태에 많은 영향을 받는다. 본 연구에서는 폴리머애자 표면에 부착된 오손물이 전기적 특성에 미치는 영향을 분석하였다. 표면에 부착된 미세한 오손물은 발수성을 급격히 저하시켰으며, 장시간 수분에 노출될 경우 상용전압에서 표면 방전의 원인이 되었다. 결과적으로 부착된 오손물은 누설전류와 절연내력에 영향을 주어 절연 특성을 저하시키게 된다.

  • PDF