• Title/Summary/Keyword: 부식

Search Result 5,481, Processing Time 0.055 seconds

Evaluate the Concrete mix by Type Accelerated Corrosion Test and Chloride Penetration Analysis with Artificial Seawater Cyclic Wet and Dry Condition (인공해수 건습반복조건에 따른 콘크리트배합별 부식촉진시험법과 염화물 침투해석평가)

  • Park, Sang-Soon;Kim, Min-Wook
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.1 no.3
    • /
    • pp.211-218
    • /
    • 2013
  • Cyclic wet and dry conditions in the marine environment structures corrosion is known to be the fastest rising. For that reason, accelerated corrosion test methods for the reproduction of tidal environment has been actively conducted. However, many studies have estimated threshold value for steel corrosion or concentrated in chloride penetration analysis. In this study, cyclic wet and dry conditions to reproduce the structure of the environment in accelerated corrosion and chloride penetration test analysis was performed. Corrosion was determined by the result of reinforcement corrosion monitoring based on galvanic potential measurement and half-cell potential method. Accelerated corrosion test results for each formulation was different corrosion periods, the order OPC> FA> BS> High-strength concrete. FEM durability interpretation program DuCOM was conducted under the same conditions as in accelerated corrosion test. The experimental RCPT tests demonstrated the validity of the result.

Changes in Corrosion Progress and Ultimate load of Tendon Under 20% and 40% of Ultimate Loading Conditions (파괴하중의 20% 및 40% 인장조건에서 텐던 부식 진행 및 파괴하중 변화)

  • Ryu, Hwa-Sung;An, Gi Hong;Hwang, Chul-Sung;Kwon, Seung-Jun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.4
    • /
    • pp.47-52
    • /
    • 2017
  • PSC (Prestressed Concrete) structures have been used widely for its engineering advantage with using total concrete area as effective compressive section. However tendon inside is exposed to such a high tensile stress that and more attentions should be paid for corrosion control. This work is for changing corrosion current and ultimate strength in tendon with increasing prestressing force in a constant corrosive condition. With increasing prestressing force, corrosion current, corrosion amount, and ultimate load are changed linearly. When prestressing force increases from 20.0 % to 40.0 %, corrosion current increases to 124.4 % and 168.0 % and ultimate load decreases to 87.8 % and 78.4 %, respectively. With inducing constant electrical potential, increasing corrosion current and reduction of strength are evaluated to be linearly related with increasing prestressing load.

A Study of Accelerated Corrosion Test and Chloride Penetration Analysis with Artificial Seawater Immersion Condition (인공해수 침지조건에 따른 부식촉진시험과 염화물침투해석에 대한 연구)

  • Park, Sang-Soon;Jeong, Ji-Won
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.1
    • /
    • pp.93-100
    • /
    • 2014
  • Steel reinforcement buried in concrete structure in submerged zone does not easily become corroded due to lack of dissolved oxygen. For that reason, accelerated corrosion test in submerged state is performed with an electrochemical method, which is not suitable for actual corrosion mechanism and makes it difficult to find relevance with long-term behavior. In this study, accelerated corrosion test was performed with the temperature and chloride concentration as main variables in order to establish a method for accelerated corrosion test in submerged zone. Corrosion was determined by the result of reinforcement corrosion monitoring based on galvanic potential measurement and half-cell potential method. The accelerated corrosion test result showed that temperature had the most dominant influence. To determine the chloride content, chloride concentration by depth in the test sample was measured. With the same conditions, chloride penetration interpretation was performed by DuCOM, a FEM durability interpretation program. Also, a test was performed to measure dissolved oxygen according to soaking conditions of artificial seawater, which was used for verifying the validity of the accelerated corrosion test result.

Effects of the Multi-Defects on Detecting Signals in Magnetic Flux Leakage System (자기누설탐상시스템에서 밀집된 다수의 결함이 탐상 신호에 미치는 영향)

  • Seo, Kang;Jeong, Hyun-Won;Park, Gwan-Soo;Lee, Min-Ho;Choi, Doo-Hyun;Lee, Seung-Hyun;Um, Chang-Gun;Shin, Pan-Seok;Kim, Chul;Rho, Yong-Woo;Yoo, Hui-Ryong;Cho, Sung-Ho;Kim, Dong-Kyu
    • Proceedings of the KIEE Conference
    • /
    • 2005.10c
    • /
    • pp.70-73
    • /
    • 2005
  • 자기누설탐상시스템은 지하에 매설된 가스관에서 발생되는 부식이나 크랙 또는 기계적 변형을 탐지하기 위한 방법으로 비파괴검사 방법의 하나이다. 가스관은 Nd자석에 의해 착자가 되고, 가스관에 부식이 발생했을 경우 가스관의 단면적이 작아지게 되어 자기누설이 발생하며, 발생된 자기누설을 홀센서로 검출하여 부식의 유무, 크기, 모양 등을 판별하게 된다. 가스관에는 한 개의 독립적인 부식도 있지만, 다수의 부식이 밀집되어 나타나기도 한다. 다수의 부식이 밀집되었을 경우 부식간의 거리에 따라 하나의 부식으로 판정되기도 하며, 그에 따라 부식의 깊이를 판정하는데 있어 정확성이 저감된다. 따라서 본 논문에서는 다수의 부식이 밀집되어 발생할 경우 자기적 영향을 분석하고, 깊이 판정에 있어 정확성을 높이기 위한 연구를 수행하였다. 이를 위해서 실제 결함을 제작하여 실험하고, 해석하여 비교하였으며 밀집된 다수의 부식에 의한 자기적 영향에 대하여 고찰하였다.

  • PDF

Morphology and Characteristics of Corrosion of Archaeological Bronzes (출토 청동유물 부식의 형태학적 고찰 및 부식생성물의 특성 연구)

  • Lee, Eun-woo;Kim, So-jin;Han, Woo-rim;Hwang, Jin-ju;Han, Min-Su
    • Korean Journal of Heritage: History & Science
    • /
    • v.46 no.3
    • /
    • pp.4-15
    • /
    • 2013
  • The study of corrosion products generated by archaeological bronzes that have been buried for a long time can provide certain evidence that enables us to understand the natural corrosion process of bronze and helps us develop conservation and preservation methods. In the present study, the specimens taken from two bronze mirrors and three bronze swords were used to study the corrosion morphology and the related phenomena such as selective corrosion of ${\alpha}$ or ${\alpha}+{\delta}$ phases, decuprification, destannification, and secondary copper. Furthermore, corrosion development was discussed based on the ions distributed throughout the corrosion layers.

Residual life and probability of pipe breakage according to pipe corrosion (상수도관의 부식에 따른 잔존수명 및 파괴확률)

  • Lee, Jae Hyeon;Kim, Hyeong Gi;Kwon, Hyuk Jae
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.420-420
    • /
    • 2021
  • 상수도관은 시간이 경과됨에 따라 부식이 발생하고 이로 인해 관의 두께 및 강도가 감소하여 점차 상수도관의 기능을 상실하게 된다. 이러한 노후 상수도관은 누수, 적수 등 수자원에 막대한 경제적인 손실을 발생시키고 사람들에게 많은 불편을 끼친다. 현재 우리나라도 전체 상수도관 중 노후 상수도관이 많은 부분을 차지하고 있기 때문에 교체나 개선이 시급한 실정이다. 하지만 전체 상수도관을 교체하는 것은 막대한 예산이 필요하기 때문에 현실적으로 어려운 문제이다. 따라서 상수도관의 노후도 분석을 통하여 상수관망의 최적 교체 우선순위를 판단하고 교체를 실시하는 것이 필요하다. 본 연구에서는 노후도 분석에 중요한 관의 부식깊이와 잔존수명을 예측하고 신뢰성해석을 통해 파괴확률을 산정하였다. 이를 위해 Romanoff(1957)와 환경부(2002)에서 실측한 상수관의 관종에 따른 관두께 변화를 적용하여 해석하였다. 실측 자료를 통해 부식깊이, 잔존수명 예측 모델을 수립하였으며 이에 따른 관의 파괴확률을 산정하였다. Romanoff(1957)의 혼합강관과 주철관에 대한 실측 자료를 사용하여 상수관의 사용연수가 10년, 20년, 30년 경과됨에 따른 부식깊이와 관파괴확률을 산정하였다. 혼합강관의 경우 사용연수에 따른 부식깊이는 0.57mm, 0.92mm, 1.21mm으로 산정되었으며, 주철관의 경우 0.16mm, 0.24mm, 0.31mm으로 산정되었다. 또한 신뢰성모형을 직경 300mm관에 적용한 결과 최대 상수도압 15kg/cm2에서 혼합강관의 사용연수에 따른 파괴확률은 3.36%, 4.65%, 6.18%로 나타났으며 주철관은 1.36%, 2.50%, 2.68%로 나타났다. 환경부(2002)의 주철관에 대한 부식 실측 자료를 통해 상수관의 사용연수 10년, 20년, 30년 경과에 따른 부식깊이와 관파괴확률을 산정하였으며 초기 관두께 측정 자료를 통해 잔존수명도 예측하였다. 부식깊이는 1.02mm, 1.25mm, 1.41mm으로 산정되었으며, 파괴확률은 5.15%, 6.30%, 7.35%로 산정되었다. 그리고 잔존수명의 경우 부식률이 20%일 때, 잔존수명은 약 30년으로 산정되었다.

  • PDF

원전 중기발생기 전열관 합금의 국부 부식 저항성에 미치는 합금 원소 및 부식 조건의 영향

  • 엄태식;박용수;김영식;정한섭;국일현
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05c
    • /
    • pp.117-122
    • /
    • 1996
  • 본 연구에서는 2개사에서 제조된 합금 600 및 합금 690 이음매 없는 관과 진공 유도 용해로 제조한 합금 690 판재에 대하여 부시 환경의 변화에 따른 특성 평가를 행하였다. 부식 평가는 양극 분극 시험을 통하여 행하였으며 부식 환경은 NaCl, HCl, NaOH(+$Na_2$SO$_4$) 용액 및 Cu$^{+}$/Cl$^{-}$ SO$_4$$^{2-}$ 용액이었다. 합금 600 및 합금 690의 양극 분극 저항성을 부식 환경에 따라 평가한 결과, 부식 용액의 종류에 따라 서로 다른 분극 거동을 보이고 있으며, 합금 690의 저항성이 합금 600의 저항성보다 우수하게 나타났다. 또한 가성 용액 중에 $Na_2$SO$_4$를 첨가할 경우 부식 속도를 가속화시키고 있다. 한편 Mo이 첨가되지 않은 합금 690M0의 경우는 Cl$^{-}$ SO$_4$$^{2-}$ 비가 증가할수록 공식 저항성이 급격히 감소하고 있으나, Mo이 첨가된 합금 690M2의 경우는 시험한 전체 비율에서 이온의 영향을 받지 않는 것으로 나타나고 있어 합금 690의 공식 저항성에 Mo이 매우 좋은 효과를 보이고 있음을 알 수 있다.

  • PDF

Research of corrosion decision on a region weld in MFL system (자기 누설 탐상 시스템에서 용접부위에서의 부식 판정에 관한 연구)

  • Jeong, Hyun-Won;Seo, Kang;Park, Gwan-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.978-980
    • /
    • 2005
  • 자기 누설 탐상(Magnetic Flux Leakage : MFL) 시스템은 비파괴 검사의 한 방법으로 검사 대상 물체를 적절히 포화시켜 부식이나 결함 부위에서의 누설 자속을 측정하여 결함의 유 무와 크기를 판단하는 방법이다. 대부분 가스관과 가스관을 연결하는 방법으로 용접을 가장 많이 사용하고 있으며 용접부위에서 부식이 가장 많이 발생하고 있다. 용접으로 인해 발생하는 자기 누설신호는 부식신호에 많은 영향을 미친다. 따라서 본 연구는 용접신호가 부식 신호에 미치는 영향을 분석하기 위해 가스관의 용접과 부식과의 거리에 따른 자기누설을 해석하고, 분석하였다. 또한 용접에 의해 왜곡된 부식신호를 보정하고, 판정을 위한 방법을 제시하였다.

  • PDF

침식부식으로 인한 원전 2차측 배관의 잔여수명 예측 시스템 개발 및 적용

  • 황경모;노희영;진태은
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.11b
    • /
    • pp.717-722
    • /
    • 1996
  • 원자력 발전소 2차측 배관에서 가장 심각한 문제로 대두되고 있는 침식부식 현상을 예측/감시하는 시스템을 개발하여 특정 원전 2차 계통의 전 부분을 망라하여 실제 평가를 수행하였으며, 이를 현장에서 초음파검사로 측정한 결과와 비교하였다. 본 시스템으로 평가한 침식부식률을 실제 측정으로 산출한 침식부식률과 비교해 본 결과, 오차 100% 이내에 포함되는 부위가 92%에 달하는 것으로 확인되었다. 본 시스템은 침식부식 이론 및 관련 변수들로부터 단상 및 2상유체 배관의 침식부식률과 ASME 코드 및 BS 코드의 허용기준에 따른 잔여수명을 예측할 수 있으며, 침식부식으로 인한 배관의 두께가 최소허용치 이하로 떨어질 경우에는 국부 배관감육평가를 수행 할 수 있는 시스템의 형태로 개발하였다.

  • PDF

월성원자력발전소 압력관 Zr-2.5Nb 합금의 수소흡수 및 부식특성 변화

  • 주기남;권상철;김영석
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1997.05b
    • /
    • pp.61-66
    • /
    • 1997
  • 월성1호기 압력관의 수소흡수 관련 자료들을 분석하였으며, 캐나다 발전소들의 결과와도 비교하였다. 압력관의 수소흡수 특성은 압력관내 위치, 사용온도, 가동이력 등에 영향을 받아 Inlet 쪽보다는 Outlet 쪽이, 사용온도가 높을수록, 또한 가동에 따른 조사량이 증가할수록 수소흡수량이 증가하였다. 한편 압력관내로의 수소흡수 거동을 규명하기 위해 Zr-2.5wt%Nb 합금의 열처리 조직 차이에 따른 수소흡수특성을 분석하였다. 수소흡수는$\alpha$-Zr 상에 비해 $\beta$-Zr, $\beta$-Nb 상에 크게 영향을 받는 것으로 보인다. 또한 합금내의 수소량 증가가 압력관 부식특성 자체에 미치는 영향을 분석하기 위하여 열처리 시편에 일정량의 수소를 charging 시킨 후 부식시험을 수행하였다. Zr-2.5wt%Nb 합금의 부식거동은 미세조직에 가장 큰 영향을 받아$\alpha$-Zr과 $\beta$-Zr 상의 시편이$\alpha$-Zr과$\beta$-Nb 상의 시편에 비해 큰 부식속도를 보였다. 또한 시편내 150ppm 이하의 수소함량은 시편의 부식거동에 별다른 영향을 없거나, 부식속도를 약간 감소시키는 것으로 추정된다.

  • PDF