• Title/Summary/Keyword: 부식진행

Search Result 381, Processing Time 0.031 seconds

Occurrence and Cenesis of Perlite from the Beomgockri Group in Janggi Area (장기지역 범곡리층군에 부존되는 진주암의 산출상태와 생성관계)

  • Noh Jin Hwan;Hong Jin-Sung
    • Journal of the Mineralogical Society of Korea
    • /
    • v.18 no.4 s.46
    • /
    • pp.277-288
    • /
    • 2005
  • Perlite, a hydrated volcanic glass, occurs mainly as a bed-like body, and is distributed intermittently along the unconformity surface between the Beomgockri Group and its lower formations, viz. Janggi Group. The perlite is intimately associated with surrounding pumiceous welded tuff and rhyodacites in space and time. Compared to the typical perlite, the perlite is rather silica-poor and impure, and thus, includes lots of phenocrysts and rock fragments. Nearly the perlite is compositionally rather close to a pitchstone than a perlite in water contents. Petrographic comparison between perlite and associated volcanic to volcaniclastic rocks indicates that pumiceous welded tuff and rhyodacite seem to be Protolith of the Perlite. A Zr/$TiO_{2}$-Nb/Y diagram and field occurrence of perlite and their protolithic rocks also conforms the above interpretation. Kn addition, remnant vesicles in perlite strongly reflect that the precursor of perlitic glass appeared to be pumice fragment as well as volcanic glass. The perlite was diagenetically formed by way of a pervasive water-rock interaction at the deposition of the Manghaesan Formation in lacustrine environment. During perlitization, $SiO_{2}$ and alkali tend to be consistently depleted. Preexisting system of the Beomgockri Group based on the perlite formation should be corrected, because the perlite was formed diagenetically without lateral persistence in its occurrence.

Characteristics of $CO_{2}$ Absorption and Degradation of Aqueous Alkanolamine Solutions in $CO_{2}$ and $CO_{2}-O_{2}$ System ($CO_{2}$$CO_{2}-O_{2}$ 시스템에서 알카놀아민류 흡수제를 이용한 $CO_{2}$ 흡수 및 흡수제 열화 특성)

  • Choi, Won-Joon;Lee, Jong-Seop;Han, Keun-Hee;Min, Byoung-Moo
    • Korean Chemical Engineering Research
    • /
    • v.49 no.2
    • /
    • pp.256-262
    • /
    • 2011
  • Amine can undergo irreversible reactions by $O_{2}$ and high temperature in amine scrubbing process and these phenomena are called "degradation". Degradation causes not only a loss of valuable amine, but also operational problems such as foaming, corrosion and fouling. In this study, using various chemical absorbents(MEA; monoethanolamine, AMP; 2-amino-2-methyl-1-propanol, DAM; 1,8-diamino-p-menthane), we examined the following variable. I) loading ratio of $CO_{2}$ at $50^{\circ}C$ and $120^{\circ}C$, ii) concentration variation and initial degradation rate constant of absorbent in $CO_{2}$ and $CO_{2}/O_{2}$ system, and iii) effect of degradation by $O_{2}$. The $CO_{2}$ loading of 20 wt% DAM was 400% and 270% higher than that of 20 wt% MEA and AMP at 50, respectively and was the largest the difference of $CO_{2}$ loading between absorption $(50^{\circ}C)$ and regeneration $(120^{\circ}C)$ condition. The initial degradation rate constant of 20 wt% DAM was $2.254{\times}10^{-4}cycle^{-1}$ which was slower than that of MEA $(2.761{\times}10^{-4}cycle^{-1})$ and AMP $(2.461{\times}10^{-4}cycle^{-1})$ in $CO_{2}$ system. Also, it was increased 30% by $O_{2}$ that effects on the degradation by $O_{2}$ was less than 100% increased. these degradation reactions was able to identify by formation of new peak in GC and FT-IR spectrum analysis.

Development of a Failure Probability Model based on Operation Data of Thermal Piping Network in District Heating System (지역난방 열배관망 운영데이터 기반의 파손확률 모델 개발)

  • Kim, Hyoung Seok;Kim, Gye Beom;Kim, Lae Hyun
    • Korean Chemical Engineering Research
    • /
    • v.55 no.3
    • /
    • pp.322-331
    • /
    • 2017
  • District heating was first introduced in Korea in 1985. As the service life of the underground thermal piping network has increased for more than 30 years, the maintenance of the underground thermal pipe has become an important issue. A variety of complex technologies are required for periodic inspection and operation management for the maintenance of the aged thermal piping network. Especially, it is required to develop a model that can be used for decision making in order to derive optimal maintenance and replacement point from the economic viewpoint in the field. In this study, the analysis was carried out based on the repair history and accident data at the operation of the thermal pipe network of five districts in the Korea District Heating Corporation. A failure probability model was developed by introducing statistical techniques of qualitative analysis and binomial logistic regression analysis. As a result of qualitative analysis of maintenance history and accident data, the most important cause of pipeline damage was construction erosion, corrosion of pipe and bad material accounted for about 82%. In the statistical model analysis, by setting the separation point of the classification to 0.25, the accuracy of the thermal pipe breakage and non-breakage classification improved to 73.5%. In order to establish the failure probability model, the fitness of the model was verified through the Hosmer and Lemeshow test, the independent test of the independent variables, and the Chi-Square test of the model. According to the results of analysis of the risk of thermal pipe network damage, the highest probability of failure was analyzed as the thermal pipeline constructed by the F construction company in the reducer pipe of less than 250mm, which is more than 10 years on the Seoul area motorway in winter. The results of this study can be used to prioritize maintenance, preventive inspection, and replacement of thermal piping systems. In addition, it will be possible to reduce the frequency of thermal pipeline damage and to use it more aggressively to manage thermal piping network by establishing and coping with accident prevention plan in advance such as inspection and maintenance.

Effect of Sodiun Hypochlorite Pretreatment, Light Intensity and Depth of Soil Covering on Germination of Cattail(Typha spp.) Seeds (Sodium Hypochlorite 처리와 광도 및 복토 깊이의 차이가 부들의 종자 발아에 미치는 영향)

  • Kim Young-Ju;Heo Jin-Ah;Hwang Yong-Soo;Ku Ja-Hyeong
    • Asian Journal of Turfgrass Science
    • /
    • v.19 no.2
    • /
    • pp.115-123
    • /
    • 2005
  • The effect of sodium hypochlorite treatment on the germination of cattail (Typha spp.) seeds was investigated in growth chambers maintained on a 14-h photoperiod with various temperatures and light intensities. Germination rates of seeds were, in general, enhanced by the increase of light intensity and temperature regardless of cattail species. Seeds of T. oreientalis had 4.3, 13.0 and $7.3\%$ germination at temperatures of 20, 25 and $30^{circ}$C, respectively, under light intensity of 7.5${\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$. T. angustata showed higher germination rate, thus, 10.7, 22.7 and $50.7\%$ under same temperature and light environment. Under high light intensity of 79.5${\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$, the germination rates of T. oreintalis and T angustata were $78.3\%$ and $88.7\%$ at $30^{circ}$C, respectively. Scarification of seeds with NaOC1 ($4\%$, available chlorine) increased germination rate in both species, especially even at low temperature of $20^{circ}$C. Germination speed was also enhanced by NaOC1 treatment. High light intensity further increased the germination rate. When NaOC1 treated seeds were sowed on the soil surface in plastic house, the seedling emergence was nearly $100\%$. Untreated seeds of T. oreintalis and T. angustara showed 40 and $50\%$, respectively, in germination under same condition. However, when the depth of soil covering was over 1.0 cm, seedling emergence was retarded more than 1 month. On the process of seedling development, emergence of mesocoty1 occurred firstly and after than primary root and first leaf were developed on the end of elongated mesocotyl. These results suggest that the promotion of seed germination by NaOC1 pretreament may be induced from the increase of light absorptivity as well as water permeability through scarifying and bleaching the seed coat.

Deterioration Diagnosis and Source Area of Rock Properties at the West Stone Pagoda, Gameunsaji Temple Site, Korea (감은사지 서탑의 풍화훼손도 진단 및 석재의 산지추정)

  • Lee Chan Hee;Lee Myeong Seong;Suh Mancheol;Choi Seok-Won;Kim Man Gap
    • Economic and Environmental Geology
    • /
    • v.37 no.5
    • /
    • pp.569-583
    • /
    • 2004
  • The rock properties of the West pagoda in the Gameunsaji temple site are composed mainly of dark grey porphyritic granodiorite with medium grained equigranular texture and developed with small numerous dioritic xenoliths. These xenoliths occurred with small holes due to different weathering processes. As a weathering results, the rock properties of this pagoda occur wholly softened to physical hardness because of a complex result of petrological, meteorological and biological causes. Southeastern part of the pagoda deteriorated seriously that the surface of rock blocks showed partially exfoliations, fractures, open cavities in course of granular decomposition of minerals, sea water spray and crystallization of salt from the eastern coast. The Joint between blocks has small or large fracture cross each other, contaminated and corrupted for inserting with concrete, cement mortar, rock fragments and iron plates, and partially accelerated coloration and fractures. There are serious contamination materials of algae, fungus, lichen and bryophytes on the margin and the surface on the roof stone of the pagoda, so it'll require conservation treatment biochemically for releasing vegetation inhabiting on the surface and the discontinuous plane of the blocks because of adding the weathering activity of stones and growing weeds naturally by soil processing on the fissure zone. Consisting rock for the conservation and restoration of the pagoda would be careful choice of new rock properties and epoxy to reinforce for the deterioration surfaces. For the attenuation of secondary contamination and surface humidity, the possible conservation treatments are needed.

Parameter Sensitivity Analysis for Spatial and Temporal Temperature Simulation in the Hapcheon Dam Reservoir (합천댐 저수지에서의 시공간적 수온모의를 위한 매개변수 민감도 분석)

  • Kim, Boram;Kang, Boosik
    • Journal of Korea Water Resources Association
    • /
    • v.46 no.12
    • /
    • pp.1181-1191
    • /
    • 2013
  • This study have implemented finding the optimal water temperature parameter set for Hapcheon dam reservoir using CE-QUAL-W2 model. In particular the sensitivity analysis was carried out for four water temperature parameters of wind sheltering coefficient (WSC), radiation heat coefficient (BETA), light extinction coefficient (EXH2O), heat exchange coefficient at the channel bed (CBHE). Firstly, WSC, BETA, EXH2O shows relatively high sensitivity in common during April to September, and CBHE does during August to November. Secondly, as a result of identifying depth range of parameter influence, BETA and EXH2O show 0~9 m and 8~14 m which is thermocline layer close to water surface, CBHE is deep layer 12 m away from bottom. Finally, applying annual or monthly optimal parameter sets indicates that the bias between two sets does not show much differences for WSC and CBHE parameters, but BETA and EXH2O parameters show $0.20^{\circ}C$ and $0.51^{\circ}C$ of monthly average biases for two parameter sets. In particular the bias reveals to be $0.4^{\circ}C$ and $1.09^{\circ}C$ during May and August that confirms the necessity of use of monthly parameters during that season. It is claimed that the current operational custom use of annual parameters in calibration of reservoir water quality model requires the improvement of using monthly parameters.

Uplift Capacity of Wood Pile for Greenhouse Foundation (온실 기초용 나무말뚝의 인발저항력 검토)

  • Yun, Sung Wook;Choi, Man Kwon;Lee, Si Young;Yu, Chan;Yoon, Yong Cheol
    • Journal of Bio-Environment Control
    • /
    • v.24 no.2
    • /
    • pp.123-127
    • /
    • 2015
  • Wood piles are rarely used in the construction of a greenhouse in Korea, but they are relatively more often used in other countries, such as the Netherlands. There are several advantages associated with wood piles: they are more cost-effective, less time-consuming, and more ecofriendly than the steel pipes (SPs) and pre-stressed highstrength (PHC) piles. However, one of the limiting conditions is that they have to be installed below the groundwater level to prevent decay. Since the groundwater levels are generally high in the reclaimed lands in Korea, wood piles are expected to be used often as reinforcements for foundations of greenhouses in these areas. In this study, we measured the uplift capacities of wood piles through in-situ uplift capacity tests with an aim to provide basic design data for wood pile foundations. In order to test their applicability, we then compared these experimentally measured ultimate uplift capacities with the ones calculated through some of the existing theoretical equations. The wood piles used in the loading tests were made of softwood (pine wood), and the tests were performed using piles with different diameters (∅25cm and ∅30cm) and embedded depths (1m, 3m, and 5m). The test results revealed that the uplift capacity of the wood piles showed a clear linearly increasing tendency in proportion to the embedded depth, with the ultimate uplift capacities for the diameters 25cm and 30cm being 9.38 and 10.56tf, respectively, at the embedded depth of 5m; thus demonstrating uplift capacities of ${\geq}9tf$. The comparison between the actually measured values of the uplift capacity and the ones calculated through equations revealed that the latter, which were obtained using the ${\alpha}$ method, were generally in an approximate agreement with the in-situ measured values.

Optimization of Supercritical Water Oxidation(SCWO) Process for Decomposing Nitromethane (Nitromethane 분해를 위한 초임계수 산화(SCWO) 공정 최적화)

  • Han, Joo Hee;Jeong, Chang Mo;Do, Seung Hoe;Han, Kee Do;Sin, Yeong Ho
    • Korean Chemical Engineering Research
    • /
    • v.44 no.6
    • /
    • pp.659-668
    • /
    • 2006
  • The optimization of supercritical water oxidation (SCWO) process for decomposing nitromethane was studied by means of a design of experiments. The optimum operating region for the SCWO process to minimize COD and T-N of treated water was obtained in a lab scale unit. The authors had compared the results from a SCWO pilot plant with those from a lab scale system to explore the problems of scale-up of SCWO process. The COD and T-N in treated waters were selected as key process output variables (KPOV) for optimization, and the reaction temperature (Temp) and the mole ratio of nitromethane to ammonium hydroxide (NAR) were selected as key process input variables (KPIV) through the preliminary tests. The central composite design as a statistical design of experiments was applied to the optimization, and the experimental results were analyzed by means of the response surface method. From the main effects analysis, it was declared that COD of treated water steeply decreased with increasing Temp but slightly decreased with an increase in NAR, and T-N decreased with increasing both Temp and NAR. At lower Temp as $420{\sim}430^{\circ}C$, the T-N steeply decreased with an increase in NAR, however its variation was negligible at higher Temp above $450^{\circ}C$. The regression equations for COD and T-N were obtained as quadratic models with coded Temp and NAR, and they were confirmed with coefficient of determination ($r^2$) and normality of standardized residuals. The optimum operating region was defined as Temp $450-460^{\circ}C$ and NAR 1.03-1.08 by the intersection area of COD < 2 mg/L and T-N < 40 mg/L with regression equations and considering corrosion prevention. To confirm the optimization results and investigate the scale-up problems of SCWO process, the nitromethane was decomposed in a pilot plant. The experimental results from a SCWO pilot plant were compared with regression equations of COD and T-N, respectively. The results of COD and T-N from a pilot plant could be predicted well with regression equations which were derived in a lab scale SCWO system, although the errors of pilot plant data were larger than lab ones. The predictabilities were confirmed by the parity plots and the normality analyses of standardized residuals.

Comparison of adhesive strength of resinous teeth splinting materials according to enamel surface treatment (법랑질 표면 처리방법에 따른 레진계 치아 고정재료의 접착강도 비교)

  • Lee, Ye-Rim;Kim, Soo-Yeon;Kim, Jin-Woo;Park, Se-Hee;Cho, Kyung-Mo
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.35 no.2
    • /
    • pp.72-80
    • /
    • 2019
  • Purpose: The purpose of this study is to compare and analyze the shear bond strength and fracture pattern in different enamel tooth surface treatments for resin splinting materials. Materials and Methods: G-FIX and LightFix were used as tooth splinting materials. Twenty bovine mandibular incisors were used for the preparation of the specimens. The exposed enamel surface was separated into four parts. Each tooth was treated with 37% phosphoric acid, 37% phosphoric acid + adhesive resin, 37% phosphoric acid + G-premio bond, and G-premio bond for each fraction. Shear bond strength was measured using a universal testing machine. After measuring the shear bond strength, the fractured surface of the specimen was magnified with a microscope to observe the fracture pattern. Two-way ANOVA was used to verify the interaction between the material and the surface treatment method. One-way ANOVA was used for comparison between the surface treatment methods of each material and post-hoc test was conducted with Scheffe's test. An independent t-test was conducted to compare shear bond strengths between materials in each surface treatment method. All statistics were conducted at 95% significance level. Results: G-FIX, a tooth splinting resin, showed similar shear bonding strength when additional adhesive resins were used when material was applied after only acid etching, and LightFix showed the highest shear bonding strength when additional adhesive resins were used after the acid etching. In addition, both G-FIX and LightFix showed the lowest shear bond strength when only self-etching adhesive was applied without additional acid etching. Verification of interactions observed interconnection between resins and surface treatment methods. Most of the mixed failure was observed in all counties. Conclusion: When using G-FIX and LightFix, which are tooth-splinting materials, it is considered that sufficient adhesion will be achieved even after applying only acid etching as instructed by the manufacturer.

Comparative Study on the Dancheong(丹靑) of Buddhist Temples in Jeolla Region focused on the Dancheong of the main building of Mihwangsa Buddhist Temple at Haenam(海南) (전라도지역 사찰단청(寺刹丹靑)의 비교 연구 해남 미황사(美黃寺) 대웅전(大雄殿) 단청을 중심으로)

  • Lee, Su Yee
    • Korean Journal of Heritage: History & Science
    • /
    • v.42 no.4
    • /
    • pp.152-171
    • /
    • 2009
  • The Dancheong(丹靑) of the main building of Mihwangsa Buddhist Temple(美黃寺) in Haenam(海南) is the leading work of the Jeolla Dancheong style, which was created in the 18th century and has been passed down to the early modern days, and boasts its excellence and originality. On the outside, one can only see the traces of the Dancheong due to the colors that fell off and deteriorated severely. On the inside, however, the general Dancheong pattern is accompanied by the painting of 1,000 Buddhas(千佛圖), which is hardly found in other Buddhist temples, and the Arahan painting, which is truly magnificent in technique and can pass as an independent painting. The Dancheong also has unique methodological characteristics that can't be found in other Dancheong works such as the painting and attaching technique. The Dancheong inside is estimated to have been created in 1754 considering the records of "Dalmasan Mihwangsasa Daebeopdang Jungsusangryangmun(達摩山美黃寺大法堂重修上樑文)", the calligraphical writings of "Mudeungsanindanhwakya(無等山人丹?也)"and "Geonryungshipgu(乾隆十九)" left in the Jungryang, and the style characteristics reflected in the Dancheong patterns and the painting of 1,000 Buddhas. The fact that there are no traces of re-Dancheong also supports the estimation that the Dancheong was created in the absolute age of 1754. The absolute age will be the reference of deciding the chronological years of Dancheong patterns and be helpful in examining the characteristics and changes by the periods. There were certain style characteristics in Dancheong by the periods and regions. The Dancheong of Jeolla region also had its own style, which includes the tendency of finishing with two- or three-fold green belts without giving meokdanggi to the meoricho and the huge jar decoration of huigol. Treating the baetbadak of all materials, whether it's Geumdancheong or morodancheong, with lines of certain thickness and colors is another style of Jeolla Dancheong from the 18th to the 20th century. The Dancheong of the Geukrakbojeon(極樂寶殿) of Cheoneunsa Buddhist Temple and Daewoongbojeon(大雄寶殿) of Naesosa Buddhist Temple in Jeolla is especially noteworthy in that it bears similar patterns and techniques to that of the main building of Mihwangsa Buddhist Temple in addition to the characteristics mentioned above. The Dancheong of Mihwangsa Buddhist Temple must have exerted so great influences on that of the two temples that it's called "the style of Mihwangsa Buddhist Temple."When adopting a broader point of view, it can be classified as one of the Dancheong styles of Jeolla. The common icons and techniques found in the Dancheong of Mihwangsa, Cheoneunsa, and Naesosa Buddhist Temple provide some clues about the influential relationships among painters of the days. They may have been created by the painters of the same school or the painters affected by those who created the Dancheong of Mihwangsa Buddhist Temple.