• Title/Summary/Keyword: 부력 수

Search Result 215, Processing Time 0.031 seconds

Lateral Load Test on the Bar-type Anti-buoyancy Anchors in the Weathered Rock (풍화암에 시공된 Bar Type 부력앵커의 수평재하시험)

  • Park, Chan-Duk;Lee, Kyu-Hwan;Ryu, Nam-Jae;Lee, Song
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.8 no.4
    • /
    • pp.165-174
    • /
    • 2004
  • This study is about a horizontal load test of buoyance anchor installed in the section where underground water level happens in the depth of 5m under the ground when the ground is excavated, because the section as a excavation section of high speed railway ${\bigcirc}{\bigcirc}$ station is near a rivers and because the section always has a reservoir of full water level on the left. Therefore, in this study we will appraise the long-term stability of the structure permanently being taken buoyance by the underground water level, through the spot test of the buoyance anchor installed in the section where underground water level happens. For that, Bar Type anchor is used, which can get enough pulling-out force by a method to resist buoyance by using friction force against the ground by high strength steel rod or steel wire. Anti-buoyance anchor is installed on the bottom slab of underground structure being taken horizontal force by the braking and accelerating of high speed train. And, It is aimed to analyze and grasp the review result of stability for the horizontal force that happens at the parking and stopping of high speed train, by executing horizontal load test for the grasping of the movements characteristic of buoyance anchor.

A study on the evaluation method of blow-out and segment lining buoyancy stability of a slurry shield TBM (쉴드TBM 이수분출 및 세그먼트라이닝 부력 안정성 평가방법 연구)

  • Jang, Yoon-Ho;Kim, Hong-Joo;Shin, Young-Wan;Chung, Hyuk-Sang
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.24 no.5
    • /
    • pp.375-393
    • /
    • 2022
  • This study was deal with blow-out and buoyancy stability evaluation method for slurry shield TBM. When applying a slurry shield TBM for the construction of a shallow tunnel under river or sea, the stability of slurry blow-out and segment lining buoyancy should be evaluated. However, there is a problem in that the currently applied theoretical formula is somewhat complicated, making it inconvenient to calculate in practice. In this study, some simple charts were proposed to easily evaluate the stability of slurry blow-out and segment lining buoyancy. In addition, the buoyancy safety factor of segment lining using the strength reduction method was evaluated and compared with the buoyancy safety factor based on the theoretical formula. The buoyancy safety factor by the theoretical formula was evaluated to be rather small, and it was confirmed that it was on the safe side. The simplified charts for the evaluation of slurry blow-out and buoyancy stability presented in this study are expected to be usefully utilized in the planning and design of undersea tunnels.

Near-Field Hydrodynamic Analysis of the Submerged Thermal Discharge Using CFD Model (CFD 모델을 이용한 수중방류 온배수의 근역 동수역학 해석)

  • Hwang, In-Tae;Kim, Deok-Ho
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.23 no.6
    • /
    • pp.466-473
    • /
    • 2011
  • The buoyancy and initial momentum fluxes make near-field dominated by buoyant jet when thermal discharge releases underwater. In order to estimate prediction capabilities of those near-field phenomena, non-hydrostatic RANS applied CFD(Computational Fluid Dynamic) model was used. Condition of model was composed based on past laboratory experiments. Numerical simulations carried out for the horizontal buoyant jet in the stagnant flow and vertical buoyant jet into crossflow. The results of simulation are compared with the terms of trajectory and dilution rate of laboratory experiments and analytic model(CorJET) results. CFD model showed a good agreement with them. CFD model can be appropriate for assessment of submerged thermal discharge effect because CFD model can resolve the limitations of near-field analytic model and far-field quasi 3D hydrodynamic model. The accuracy and capability of the CFD model is reviewed in this study. If the computational efficiency get improved, CFD model can be widely applied for simulation of transport and diffusion of submerged thermal discharge.

부력식 수위계의 관측 특성

  • Lee, Bu-Yong;Park, Ji-Chang;Jang, Seong-Won;Han, Jin-Su
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2006.11a
    • /
    • pp.209-210
    • /
    • 2006
  • 장비의 설치 후 수위 값에 대한 보정 없이 1년간 관측한 결과 20 미터 측정 구간에 대해서 최대 20 cm의 오차가 발생하여 약 1%의 오차가 있었으며, 그 후 오차는 줄어들어 약 ${\pm}2\;cm$이내의 값을 유지하는 매우 안정된 일변화 경향을 나타내었다. 이는 측정 오차 0.1%에 해당하는 매우 안정된 관측 자료이다. 개선된 부력식 수위계는 관측에 있어서 1년간 야외에서 안정된 값을 나타내어 댐에서의 수위와 지하수 수위 측정에 활용 가능성을 볼 수 있다.

  • PDF

Minimum Dilution of Vertical Multijet Discharging into Stagnant Water (정지수체로 방류된 연직다중\ulcorner㈏\ulcorner최소희석률)

  • Kim, Hong-Sik;Seo, Il-Won;Yu, Dae-Yeong;Seo, Yong-Won
    • Journal of Korea Water Resources Association
    • /
    • v.32 no.2
    • /
    • pp.153-162
    • /
    • 1999
  • In this study, mixing and dilution characteristics of vertical multijet discharged by multiport diffuser into stagnant water are investigated. The results obtained from the experiment of multiport diffuser performed in the three dimensional flume are as follows. As far as merging process of multiport diffuser is concerned, merging starts at about z/l = 3 although merging length is dependent upon stability condition and thereafter lateral temperature distribution becomes gradually uniform which is typical distribution of plane jet. Analyses of experimental data for minimum dilution show that characteristics of minimum dilution are described based on three regions which are jet region where momentum is dominated, intermediate region, and plume region where buoyancy is dominated. Minimum dilution coefficient in plume region of multiport diffuser obtained in this study is 15% higher than that of plane diffuser. This is because individual jet of multiport diffuser entrains more ambient water before merging is occurred, and therefore dilution increases.

  • PDF

Design and Control of a Biomimetic Fish Robot (생체 모방 로봇 물고기의 설계와 제어에 관한 연구)

  • Kim, Young-Jin;Kim, Seung-Jae;Yang, Kyung-Sun;Lee, Jeong-Min;Yim, Chung-Hyuk;Kim, Dong-Hwan
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.1
    • /
    • pp.1-7
    • /
    • 2012
  • This paper introduces the mechanical design, fabrication, and control of a biomimetic fish robot whose driving motions resemble a real fish's flexibility and movement. This robot uses two motors create flexible movement like that of a fish. Several schemes, such as neutral buoyancy, fast underwater swimming, and direction changes, are introduced. The tail of the fish robot is made of a polymer material for flexible movement. The interior of the tail contains a joint and a wire. A sine wave command was applied to the tail to produce motion resembling a real fish swimming, and a buoy control device was installed. The up and down motion of the robot fish was controlled using this device.

Tension Test on the Bar-type Anti-buoyancy Anchors in the Weathered Rock (풍화암에 시공된 Bar Type 부력저항 앵커의 인장 시험)

  • Park, Chan-Duk;Lee, Kyu-Hwan;Ryu, Nam-Jae;Lee, Song
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.8 no.1
    • /
    • pp.175-181
    • /
    • 2004
  • This study is about a section where underground water level occurs at the underground 5m depth by the excavation of the ground, as a stream is adjacent to a excavation section of High Speed Railway ${\bigcirc}{\bigcirc}$ Station construction sections and a reservoir being always full of water is located at the left side of the construction section. Therefore this test is executed for the design and construction of buoyance anchors able to permanently prevent buoyance by the underground water level at working and for the stable construction and permanent smooth maintenance of structures. In this test, bar type anchors are divided according to their length and standard to execute test-anchor test, and In spot test, 9 test-anchors test, proof test to construction process, suitability test and acceptance test are executed 4 times to 9 test-anchors by dividing anchors according to the length of permanent anchor, the outer diameter of bar and boring diameter. Standard motion characteristic centering on load transmission and break mechanism of bar-type anchors for the prevention of buoyance will be showed in the thesis.

Thermophoresis of highly absorbing, emitting particles suspended in a mixed convection flow system (혼합 대류 유동시스템에 부유된 고흡수 방사하는 입자의 열 확산)

  • Yoa, S. J.
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.14 no.3
    • /
    • pp.115-125
    • /
    • 1992
  • 혼합 대류 이상 유동 시스템에 부유된 슈트와 미분탄과 같은 고흡수, 방사하는 입자의 열확산적 입자이동에 대한 복사 및 부력효과를 수치적으로 검토하였다. 기체 및 입자유동의 지배방정식 들은 Euler 관점의 two-fluid model의 근간에서 수행되었으며, 에너지 보존식의 비선형 복사 생 성항은 P-1 근사방법에 의해 계산되었다. 혼합 대류 유동에서의 입자의 열확산 현상은 복사 열 전달과 커플링되며, 복사효과의 증가는 부력효과를 상대적으로 감소시켜 부력효과에 의한 입자 부착율을 완화시켰다. 복사효과가 무시될 때 Grashof 수의 증가에 따라 입자의 확산효과는 감 소되었으며, 복사효과가 함께 작용될 때 입자 부착율은 증가됨을 보였다.

  • PDF

Vertical Buoyant Jet in Tidal Water-Stagnant Environment (조석(潮汐)의 영향을 받는 수역(水域)에서 연직상향부력(鉛直上向浮力)? -정지수역(靜止水域)-)

  • Yoon, Tae Hoon;Cha, Young Kee;Kim, Chang Wan
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.6 no.2
    • /
    • pp.93-101
    • /
    • 1986
  • The behavior of a plane buoyant jet discharged vertically upward into a stagnant uniform environment is analyzed by continuity, momentum transport equation by numerical scheme. The governing equations are solved by finite difference method employing stream function and vorticity transport and Prandtl's turbulent model. Results for centerline velocities and temperatures, temperature distribution and flow pattern in receiving environment due to buoyant jet in the range of discharge densimetric Froude number of 4 to 32 show good agreement with published data. Spreading rate and dispersion ratio, which are required in integral type analysis of whole range of buoyant jet and have not been obtained yet, are derived in terms of discharge densimetric Froude number and vertical distance from source.

  • PDF

An Analysis iff the Mutural Relation between Sinkhole and 'Permanent under Draingage System' as A Measure of Non Floating (씽크홀(SINKHOLE)과 부력방지 대책인 '영구배수 공법'과의 상관관계)

  • Kwon, Hoi ku
    • Proceedings of the Korean Society of Disaster Information Conference
    • /
    • 2017.11a
    • /
    • pp.257-259
    • /
    • 2017
  • 최근에 국내에서 입법된 "지하안전관리에 관한 특별법"의 지하안전영향평가 등에서 지하매설물 및 굴착공사 관리의 중요성을 강조하고 있지만, 아직까지는 지하를 개발함에 있어 지반의 안전과 관련된 사항은 미흡한 실정으로 도심지 지반침하( Sinkhole) 현상이 매년 증가하고 있다. 그리고 지반침하(Sinkhole)는 발생이 될 경우 인명피해는 물론 도로나 주변 건물들에 막대한 피해를 줄 수 있는 소지가 충분한 대상으로 사료됨에도 불구하고 이러한 현상을 건설현장에서 심각하게 받아들이는 분위기는 어느 곳에서도 감지되지 않는다. 다만 정부부처나 공공기관에서 국회차원의 지대한 관심에 부응하여 이에 대해 광범위한 연구와 조사에 막대한 예산을 투입하여 다방면에서 진행되고 있는 것으로 파악되고 있다. 또한 이러한 연구결과의 자료를 근거로 하여 지반침하 사고의 주요 원인을 조사해본 결과 상하수도관 손상과 무리한 인접굴착공사 및 대부분의 대형건축공사 현장에 채택되고 있는 부력방지 대책의 일환인 영구배수공법의 무분별한 적용을 들 수 있었다. 이러한 상황에서 그 중 비용과 난이도를 고려현장에서 용이하게 저감할 수 있는 방법인 영구배수공법을 선정하여 영구배수공법의 이론적 고찰과 공학적 타당성(구조체 부상방지 안전성 검토기준)을 연구하여 무분별한 영구배수공법 적용으로 지반침하(Sinkhole)가 발생하는 것을 막아 인명피해와 도로나 구조물의 안전성을 확보하고 나아가 영구배수공법 적용으로 항구적 발생하는 천문학적인 유지관리비의 절감이 목적이다.

  • PDF