• Title/Summary/Keyword: 봉합 나사못

Search Result 39, Processing Time 0.034 seconds

Clinical Results of Arthroscopic Bankart Repair with Absorbable Knot-tying and Absorbable Knotless Suture Anchors (견관절 전방 불안정증에서 관절경적 방카트르 봉합술 시 흡수성 매듭 봉합 나사못과 흡수성 비 매듭 봉합 나사못을 이용한 임상적 치료결과 비교)

  • Kim, Seong-Jun;Lu, Yao-Jia;Oh, Kyung-Soo;Bahng, Seung-Chul;Park, Jin-Young
    • Journal of the Korean Arthroscopy Society
    • /
    • v.17 no.1
    • /
    • pp.50-55
    • /
    • 2013
  • Purpose: The purpose of this study was to compare the clinical results of absorbable knot-tying and absorbable knotless suture anchors in arthroscopic Bankart repair. Materials and Methods: This study compared the patients who underwent arthroscopic Bankart repairs using absorbable knottying suture anchors (59 patients: KT Group), and absorbable knotless suture anchors (52 patients: KL Group). Preoperative and postoperative evaluations were performed by Rowe scores, patient satisfaction score, visual analogue scale (VAS), American shoulder and elbow surgeons (ASES) score, range of motion (ROM), and re-dislocation rate. Results: Postoperative VAS, Rowe scores, ASES score were significantly not different between the 2 groups (VAS: p=0.250, Rowe score: p=0.412, ASES: p=0.052). Mean postoperative VAS was 0.5 in KT Group and 0.8 in KL Group (p=0.250), and limited ROM was noted only in one patient in KL Group. Mean Rowe score was 94.3 in KT Group and 96.3 in KL Group (p=0.412), and mean ASES score was 97.3 in KT Group and 94.0 in KL Group (p=0.052). Re-dislocation rate were no different between the 2 groups. Conclusion: There were no differences in clinical outcomes and re-dislocation rate between Knot-Tying and Knotless repairs.

  • PDF

Arthroscopic Treatment of Metallic Suture Anchor Failures after Bankart Repair (Bankart 수술 후 발생한 금속 봉합 나사못 합병증의 관절경적 치료)

  • Shin, Sang-Jin;Jung, Jae-Hoon;Kim, Sung-Jae;Yoo, Jae-Doo
    • Journal of the Korean Arthroscopy Society
    • /
    • v.10 no.1
    • /
    • pp.70-76
    • /
    • 2006
  • Purpose: This study presents 5 patients who had metallic anchor protrusion on glenoid after Bankart repair in anterior shoulder instability and reviewed the cause, clinical feature and arthroscopic removal technique. Method and Materials: 5 male with average age of 22 years (range 19 to 25 years) were included. 4 patients had arthroscopic Bankart repair and 1 patient had open repair for anterior shoulder instability. They had protruded metallic suture anchors on glenoid and the protruded suture anchors were removed arthroscopically using larger suture anchor empty inserter. Results: 4 patients had painful clicking sound with motion of abduction and external rotation and 1 patient showed shoulder instability. The ROM showed normal except mild degrees loss of external rotation. The position of protruded metallic anchor was 2, 3 and 5 O'clock in three patients and 4 O'clock in 2 patients. In 2 patients, the metallic suture anchor was malpositioned about 5mm off on the medial side from the anterior glenoid edge. All had Outerbrige classification Grade II-III chondral damage on humeral head and 1 patient showed glenoid cartilage destruction. None had shoulder instability after 2 years of follow-up. Constant score was 65 preoperatively and 89 postoperatively. ASES score was 67 preoperatively and 88 postoperatively. Conclusion: Symptoms of protruded suture anchor are not combined with instability. Most of symptoms were revealed from the rehabilitation period and confused with postoperative pain. Prompt diagnosis and early arthroscopic removal or impaction of protruded metallic suture anchor is recommended because of serious glenohumeral cartilage destruction. This is easy and simple and reproducible method to remove protruded metallic suture anchor arthroscopically.

  • PDF

Outcomes after Arthroscopic Repair of Anterior Shoulder Instability after Metal Anchor to Biodegradable Anchor Fixation (견관절 전방 불안정성에 대한 관절경 치료 결과: 금속 나사못 및 흡수성 나사못 고정의 결과 비교)

  • Choi, Chang-Hyuk;Kim, Shin-Kun;Han, Bo-Ram
    • Clinics in Shoulder and Elbow
    • /
    • v.11 no.2
    • /
    • pp.158-164
    • /
    • 2008
  • Purpose: We compared the results of arthroscopic Bankart repair using metal and biodegradable anchor fixation. Materials & Methods: We reviewed 26 patients with anterior shoulder instability treated by arthroscopic Bankart repair from October, 2006, to March, 2007, 15 patients with metal anchors and 11 patients with biodegradable anchors. The average age was 27.4 years old (range: 17~55) and mean follow-up was 14 months (range: 12~17 months). Functional outcome was evaluated using the Korean Shoulder Score for Instability (KSSI), Rowe's Bankart Grading scale (RBGS), ASES score, and UCLA scores. Results: In the metal-anchor group, the improvements of mean KSSI, ASES, UCLA score, and RBGS were 20.6, 24.0, 4.0, and 45.5, respectively. In the biodegradable anchor group, improvements of mean KSSI, ASES, UCLA score, and RBGS were 21.0, 23.6, 4.6, and 48.9. The improvements in final outcomes were not significantly different (p>.05). One metal problem and one traumatic redislocation occurred in the metal group. Conclusion: Both techniques produced satisfactory outcomes in the treatment of traumatic anterior instability. The biodegradable anchor group could also avoid problems with metal anchors.

Arthroscopic Repair of Type II SLAP lesion with Bio-knotless Anchor (제 2형 SLAP 병변에 대하여 흡수성 봉합 나사못을 이용한 관절경적 봉합 수술의 임상적 결과)

  • Yum, Jae-Kwang;Chung, Hyung-Jin;Ra, Ho-Jong
    • Clinics in Shoulder and Elbow
    • /
    • v.10 no.1
    • /
    • pp.73-77
    • /
    • 2007
  • Purpose: This study reports the clinical results of the arthroscopic repair of type II SLAP lesion with bio-knotless anchor. Materials and Methods: 25 cases of 25 patients (20 male, 5 female) were included in this study. The average age was 44.5 years old. Preoperative ASES score was average 44. Arthroscopic SLAP repair with 1 or 2 bio-knotless anchors were performed in all cases. The average follow up period was 15 months. Results: The ASES score improved to average 92.7 at last follow up period and 23 cases had full range of motion of the shoulder. 2 case had mild limited range of motion of the shoulder without any problem in normal activity. Conclusion: Arthroscopic repair with bio-knotless anchor in type II SLAP lesion is one of the good methods because of the good clinical results.

Anchor Hole Augmentation with Bone Cement in Arthroscopic Rotator Cuff Repair (관절경적 회전근 개 봉합술에서 골 시멘트를 이용한 봉합 나사 구멍 보강술)

  • Lee, Ho-Min;Tae, Suk-Kee;Park, Jeong-Min
    • Clinics in Shoulder and Elbow
    • /
    • v.13 no.2
    • /
    • pp.237-243
    • /
    • 2010
  • Purpose: In arthroscopic rotator cuff repair, the crucial step is secure fixation of Anchor to bone. However, osteoporosis of the tuberosity is frequently encountered in old patients, and can cause insecure fixation of anchors. The Aim of our study was to introduce a technique for anchor hole augmentation with bone cement when fixation failure of an anchor occurs, and to investigate the outcome. Materials and methods: Among 223 rotator cuff repairs performed between 2005 and 2009, anchor hole augmentation with polymethylmethacrylate was performed in 15 cases (all females; mean age of 65 years: range 49~77). Bone cement was injected into the anchor hole in a thick fluid state and the procedure was repeated to make a pot-like cement mantle. The anchor was inserted into the cement mantle while the cement hardened. The outcome was investigated, on average, at 16 months (6~32). Results: Radiographs showed cystic changes of the tuberosity. On follow-up radiographs and MRI, a change in the cement mantle was not noted. The final average UCLA score was 31 (28~35); 6 had excellent, 8 good and 1 fair results (p=0.008). Age-sex matched Constants score was 90 (74~98) (p=0.008). Conclusion: Anchor hole augmentation with bone cement is useful when fixation failure of an anchor is encountered due to bone atrophy. Anchor hole augmentation with bone cement does not negatively influence the outcome.

Subclavian Portal Approach for Isolated Subscapularis Tendon Tear - Technical Note - (견갑하 건 단독 파열에 대한 쇄골하 삽입구를 이용한 봉합술 - 술기보고 -)

  • Choi, Chang-Hyuk;Kim, Shin-Kun;Chang, Il-Woong;Kim, Se-Sik
    • Clinics in Shoulder and Elbow
    • /
    • v.12 no.2
    • /
    • pp.221-225
    • /
    • 2009
  • Purpose: For an isolated tear of the subscapularis tendon, the presented technique using a subclavian portal provides both a good angle for anchor placement and sufficient space for managing the upper portion of a subscapularis tendon tear. Materials and Methods: The conventional method needs 2 additional portals for traction, debriding the footprint and anchor fixation for repair. The presented technique requires only an anterior portal for suture management and a subclavian portal without cannula for suture anchoring and placement of suture hooks. Results: The two suture limbs of the anchor can be placed on the subscapularis tendon by the switching technique and these limbs are repaired sequentially. Conclusion: This technique is simple and reproducible and it can be applied to partial tears and minimally retracted subscapularis tears.

A Suture Bridge Transosseous-Equivalent Technique for Bankart Lesions with Deficient Bony Stability - Technical Note - (골안정성 결손을 가진 Bankart 병변에 대한 경 골-유사 교량형 봉합술식 - 술기 보고 -)

  • Choi, Chang-Hyuk;Kim, Shin-Kun;Chang, Il-Woong;Chae, Sung-Bum
    • Journal of the Korean Arthroscopy Society
    • /
    • v.13 no.2
    • /
    • pp.179-182
    • /
    • 2009
  • Purpose: Point fixation at the margin of the glenoid is a limitation of conventional arthroscopic stabilization using suture anchors, and does not afford sufficient footprint healing, especially in glenoid bone deficiency. So, we introduce an arthroscopic suture bridge transosseous-equivalent technique for bony Bankart lesions to avoid the technical disadvantage of point contact with anchor fixation and to improve mechanical stability through cross compression of the labrum. Surgical approach: The technique was adapted from the transosseous-equivalent rotator cuff repair technique using suture bridges, which improved the pressurized contact area and mean pressure between the tendon and footprint. After preparation of the glenoid bed by removal, reshaping, or mobilization of the bony lesion, two anchors (3.0 mm Biofastak, $Arthrex^{(R)}$, Naples, FL) were inserted into the superior and inferior portion of the bony Bankart lesion. Using a suture hook, medial mattress sutures were applied around the capsulolabral portion of the IGHL complex to obtain sufficient depth of glenoid coverage. A 3.5 mm pushloc anchor ($Arthrex^{(R)}$, Naples, FL) hole was made in the articular edge of the anterior glenoid rim. distal, suture bridge was applied, and proximal was inserted to mobilize the labrum in the proximal direction. This avoided the technical disadvantage of point contact with anchor fixation and decreased the level of gap formation through cross-compression of the labrum.

  • PDF

Osteolysis-Related Bioabsorbable Suture Anchor Fixation in a Medial Collateral Ligament Avulsion Fracture during Total Knee Arthroplasty (슬관절 인공관절 치환술 중 발생한 내측 측부 인대 견열 골절에 대해 생흡수성 봉합 나사못을 이용한 고정 후 발생한 골용해)

  • Huh, Jung-Wook;Park, Man-Jun;Hong, Seong-Hwak;Park, Joon-Hyung
    • Journal of the Korean Orthopaedic Association
    • /
    • v.55 no.6
    • /
    • pp.545-549
    • /
    • 2020
  • Although rare, the treatment options for a medial collateral avulsion fracture during total knee arthroplasty (TKA) range from conservative management using a cast and orthosis to internal fixation using metal screws. Bioabsorbable suture anchors have been used to replace metal fixators with distinct advantages, such as biocompatibility, radiolucency, and unnecessary second removal surgery, but complications, such as osteolysis, have been reported. This paper reports a potential risk of an extensive osteolysis-related suture anchor fixation of a medial collateral ligament (MCL) avulsion fracture during TKA in conjunction with a literature review.

Clinical & Radiologic Result of Arthroscopic Bankart Repair Using Knotless Suture Anchor (비매듭 금속 봉합 나사못을 이용한 관절경적 방카트 복원술: 임상적 및 방사선학적 결과의 비교)

  • Oh, Jung-Hwan;Lee, Sang-Hoon;Park, Hong-Keun;Jeon, Suk-Ha;Park, Joon-Suk;Kim, Cheol-Ki;Park, Jin-Young
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.7 no.2
    • /
    • pp.135-141
    • /
    • 2008
  • Purpose: To study the clinical and radiologic results with arthroscopic Bankart repair using knotless metal suture anchor. Materials and Methods: From February 2001 to January 2005, 68 patients, who underwent arthroscopic Bankart repair using knotless suture anchor and were followed up more than 12 months, were evaluated. A mean follow-up period was 34 months. All shoulders were evaluated by Rowe scoring system, range of motion of the shoulder, pain degree of VAS, and This was compared by radiologic findings after surgery. Results: The Rowe scoring system was 43.30 preoperatively, which improved to 95.55 postoperatively. At last follow-up, there was no significance difference between operated shoulder and non-operated shoulder in range of motion. The degree of VAS was measured from 3.3 preoperatively to 0.5 postoperatively. The radiolucent line was shown around suture anchor in 15 shoulders. 2 shoulders of 15 shoulders were reoperated due to redislocation and anchor arthropathy. In Odds ratio, this group (15 patients) had more 2.6 times the subjective instability than other group (53 patients). Conclusion: Arthroscopic Bankart repair using knotless anchor suture is very effective operative technique. But we have to be careful because the radiolucent line around anchor showed up during a follow -up period may indicate poor prognosis.

  • PDF