• Title/Summary/Keyword: 볼 접합부

Search Result 81, Processing Time 0.027 seconds

Effect of Reflow Number and Surface Finish on the High Speed Shear Properties of Sn-Ag-Cu Lead-free Solder Bump (리플로우 횟수와 표면처리에 따른 Sn-Ag-Cu계 무연 솔더 범프의 고속전단 특성평가)

  • Jang, Im-Nam;Park, Jai-Hyun;Ahn, Yong-Sik
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.16 no.3
    • /
    • pp.11-17
    • /
    • 2009
  • The drop impact reliability comes to be important for evaluation of the life time of mobile electronic products such as cellular phone. The drop impact reliability of solder joint is generally affected by the kinds of pad and reflow number, therefore, the reliability evaluation is needed. Drop impact test proposed by JEDEC has been used as a standard method, however, which requires high cost and long time. The drop impact reliability can be indirectly evaluated by using high speed shear test of solder joints. Solder joints formed on 3 kinds of surface finishes OSP (Organic Solderability Preservation), ENIG (Electroless Nickel Immersion Gold) and ENEPIG (Electroless Nickel Electroless Palladium Immersion Gold) was investigated. The shear strength was analysed with the morphology change of intermetallic compound (IMC) layer according to reflow number. The layer thickness of IMC was increased with the increase of reflow number, which resulted in the decrease of the high speed shear strength and impact energy. The order of the high speed shear strength and impact energy was ENEPIG > ENIG > OSP after the 1st reflow, and ENEPIG > OSP > ENIG after 8th reflow.

  • PDF

The Role of Colonoscopy in Children with Hematochezia (소아 선혈변에서 대장 내시경 검사의 역할)

  • We, Ju-Hee;Park, Hyun-Suk;Park, Jae-Hong
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.14 no.2
    • /
    • pp.155-160
    • /
    • 2011
  • Purpose: This study was performed to evaluate the role of colonoscopy in children with hematochezia. Methods: We retrospectively reviewed the medical records of 277 children who underwent colonoscopy because of hematochezia between January, 2003 and July, 2010. Results: The mean age of the patients was $6.0{\pm}4.4$ (7 days~17.8 years) years. The male to female ratio was 2.2:1. The duration between the 1st episode of hematochezia and colonoscopy was $4.9{\pm}12.1$ months. Characteristics of hematochezia included red stool (65.1%), blood on wipe (12.8%), bloody toilet (11.9%), and blood dripping (10.2%). The most proximal region of colonoscopic approach was terminal ileum (84.5%), cecum (9.5%), hepatic flexure (2.8%), and splenic flexure (3.2%). Eighty five patients (30.6%) had no specific abnormal findings. Major causes of hematochezia were polyp (26.4%), food protein induced proctocolitis (6.9%), infectious colitis (5.4%), lymphofolliculitis (5.7%), non specific colitis (5.7%), and vascular ectasia (5.1%). The hemorrhagic sites included the rectum (24.0%), rectosigmoid junction (18.1%), sigmoid colon (13.5%), ascending colon (14.2%), transverse colon (11.3%), descending colon (7.8%), cecum (8.1%), and terminal ileum (3.1%). The recurrence rate of hematochezia after colonoscopy was 19.1%. Colonoscopy was performed in 262 patients (94.6%) with conscious sedation. Endoscopic hemostasis was performed in 5 patients. Complications of colonoscopy or sedation were not found. Conclusion: The causes and lesional localization of pediatric hematochezia were diverse. Colonoscopy has an important role in the diagnosis and treatment of hematochezia in children. Total colonoscopy is recommended to detect the cause of hematochezia.

A Study on the Microstructure Formation of Sn Solder Bumps by Organic Additives and Current Density (유기첨가제 및 전류밀도에 의한 Sn 솔더 범프의 미세조직 형성 연구)

  • Kim, Sang-Hyeok;Kim, Seong-Jin;Shin, Han-Kyun;Heo, Cheol-Ho;Moon, Seongjae;Lee, Hyo-Jong
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.28 no.1
    • /
    • pp.47-54
    • /
    • 2021
  • For the bonding of smaller PCB solder bumps of less than 100 microns, an experiment was performed to make up a tin plating solution and find plating conditions in order to produce a bump pattern through tin electroplating, replacing the previous PCB solder bumps process by microballs. After SR patterning, a Cu seed layer was formed, and then, through DFR patterning, a pattern in which Sn can be selectively plated only within the SR pattern was formed on the PCB substrate. The tin plating solution was made based on methanesulfonic acid, and hydroquinone was used as an antioxidant to prevent oxidation of divalent tin ions. Triton X-100 was used as a surfactant, and gelatin was used as a grain refiner. By measuring the electrochemical polarization curve, the characteristics of organic additives in Triton X-100 and gelatin were compared. It was confirmed that the addition of Triton X-100 suppressed hydrogen generation up to -1 V vs. NHE, whereas gelatin inhibited hydrogen generation up to -0.7 V vs. NHE. As the current density increased, there was a general tendency that the grain size became finer, and it was observed that it became finer when gelatin was added.

Modeling Residual Water in the Gas Diffusion Layer of a Polymer Electrolyte Membrane Fuel Cell and Analyzing Performance Changes (고분자 전해질막 연료전지의 기체확산층 내부 잔류수 모델링 및 성능변화해석)

  • Jiwon Jang;Junbom Kim
    • Applied Chemistry for Engineering
    • /
    • v.35 no.1
    • /
    • pp.16-22
    • /
    • 2024
  • Polymer electrolyte membrane fuel cells have the advantage of low operating temperatures and fast startup and response characteristics compared to others. Simulation studies are actively researched because their cost and time benefits. In this study, the resistance of water residual in the gas diffusion layer (GDL) of the unit cell was added to the existing equation to compare the actual data with the model data. The experiments were conducted with a 25 cm2 unit cell, and the samples were separated into stopping times of 0, 10, and 60 minutes following primary impedance measurement, activation, and polarization curve data acquisition. This gives 0, 10, and 60 minutes for the residual water in the GDL to evaporate. Without the rest period, the magnitude of the performance improvement was not significantly different at the same potential and flow rate, but the rest period did improve the performance of the membrane electrode assembly when measuring impedance. By changing the magnitude of the resistance reduction to an overvoltage, the voltage difference between the fuel cell model with and without residual water was compared, and the error rate in the high current density region, which is dominated by concentration losses, was reduced.

Efficacy of Transcervical Fallopian Tube Catheterization in Infertility Patients with Fallopian Tube Occlusion (난관 폐쇄에 기인한 불임 환자에서 난관 개통술의 효용성)

  • Park, Chan-Woo;Cha, Sun-Hwa;Yang, Kwang-Moon;Han, Ae-Ra;Yoo, Ji-Hee;Song, In-Ok;Kim, Hye-OK;Kang, Inn-Soo;Koong, Mi-Kyoung;Lee, Kyung-Sang
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.37 no.4
    • /
    • pp.321-327
    • /
    • 2010
  • Objective: To evaluate the significance and efficacy of trans-cervical fallopian tube catheterization (TFTC) in diagnosis and optimal treatment modality for tubal blockage. Methods: The retrospective study was performed in those underwent TFTC from January 2005 to December 2009. A total of 342 fallopian tubes in 215 patients which showed tubal blockage in hysterosalpingography (HSG), were subjected to TFTC. Recanalization rate (RR) was compared according to portion of tubal blockage; proximal, isthmic and distal portion and blockage type; tapering, concave, and convex type. Results: In total, RR was 72.5% (248/342 tube). According to the portion of tubal blockage, RR was 83.8% in proximal, 45.6% in isthmic and 100% in distal portion. RR was 92.3% in tapering, 80.2% in concave and 25.5% in convex type, respectively. There were 98 pregnancies in 156 patients after successful recanalization, which shows 62.7% pregnancy rate. Conclusio: TFTC were capable of recanalizing tubal blockage in 248 of 342 tubes in 156 of 215 patients (72.5%). The RR was increased with proximal portion and tapering type tubal blockage.

When do we use the Recycling Autograft in Limb Salvage Surgery? (사지구제술에서 언제 재활용 자가골 이식술이 유용한가?)

  • Kim, Jae-Do;Jang, Jae-Ho;Cho, Yool;Kim, Ji-Youn;Chung, So-Hak
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.14 no.2
    • /
    • pp.95-105
    • /
    • 2008
  • Purpose: To identify which is the best procedure in recycling autograft according to the resection & reconstruction type and recycling methods, and so when the recycling autograft is used in limb salvage surgery. Materials and Methods: We have treated fifty-eight patients (34 male, 24 female; age range 5 to 74 years, mean age 36.5 years), who had the malignant musculoskeletal tumors, with recycling autograft (47 patients with extracoporeal irradiation, 11 patients with pasteurization) from December 1995 to February 2006. The resection and reconstruction type was 3 cases with fragmentary, 8 intercalary, 23 rAPC (recycling-Autograft-Prosthesis composite), 18 osteoarticular, 5 total joint and 1 soft tissue (achilles tendon). The result was evaluated by the radiologic union at junctional site, the functional score by musculoskeletal tumor society score and complications according to the resection & reconstruction type and recycling methods. Results: The junctional union was obtained at 15.0 months in extracoporeal irradiation and 12.6 months in pasteurization. Also the mean radiologic union was shown at 6.0 months in fragmentary, 12.8 months in intercalary, 10 months in rAPC, 23.3 months in osteoarticular and 15.6 months in total joint. The functional score was 65.5% in fragmentary, 60.8% in intercalary, 62.8% in APC (except pelvis), 66.0% in osteoarticular and 66.6% in total joint. We have experienced 1 infection, 1 prutrusio acetabuli in pasteurization (18.1%) and other 22 complications (3 deep infections, 8 nonunions, 2 fractures, 2 epiphyseal problems, 5 joint instabilities, 2 local recurrence) in extracoporeal irradiation (46.8%). Also we have experienced 3 complications (3 nonunions) in intercalary (37.5%), 9 complications (4 nonunions, 1 deep infection, 1 periprosthetic fracture, 1 epiphyseal problem, 1 local recurrence, 1 protrusio acetabuli) in rAPC (50.0%), 6 complications (2 deep infections, 2 nonunions, 1 epiphyseal problem, 1 pathologic fracture) in osteoarticular (33.3%), 5 complications (5 joint instabilities) in total joint (100%) and 1 complication(1 local recurrence) in soft tissue (100%). Conclusion: In our experience, according to the resection & reconstruction type fragmentary and intercalary may have several advantages such as good radiologic and functional result and low rate of complication. And it seems that rAPC was available in case which have no sufficient residual bone stock. Also the pasteurization may have more advantages than that of the extracorporeal irradiation.

  • PDF

Effects of Surface Offcut Angle of GaAs Substrate on Dislocation Density of InGaP Epilayers (GaAs기판의 표면 Offcut각도가 InGaP 에피막의 전위밀도에 미치는 영향)

  • 이종원;박경수;이종식
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.9 no.3
    • /
    • pp.49-56
    • /
    • 2002
  • In this study, the InGaP epilayers were grown on the exact and the $2^{\circ}$, $6^{\circ}$, $10^{\circ}$ of cut GaAs substrates by metal-organic vapor phase epitaxy, and the effects of interfacial elastic strains determined by the substrate offcut angle upon the resulting dislocation density of epilayer were investigated for the first time. The elastic strains were obtained from lattice mismatch and lattice misfit by TXRD, and the dislocation densities from epilayer x-ray FWHM. For the offcut angle range used in this study, the elastic strain was maximum and x-ray FWHM minimum at offcut angle $6^{\circ}$. From 11K PL measurements, PL wavelength was found to decrease with an increase of offcut angle. PL intensity was maximum at offcut angle $6^{\circ}$. TEM results showed that the electron diffraction pattern was of typical zincblende structure, and that the dislocation density was minimum for substrate offcut angle $6^{\circ}$. The results obtained in this study, along with the device fabrication process and beam characteristics, clearly demonstrated that the optimum substrate offcut angle for the InGaP/GaAs heterostructures is $6^{\circ}$.

  • PDF

Evaluation of Structural Performance of RC Beam with Different Depths to Lap Splice Detail of SD700 Headed Bar (SD700 확대머리 철근의 겹침이음 상세를 적용한 단차가 있는 RC 보의 구조성능 평가)

  • Lee, Ji-Hyeong;Kim, Seung-Hun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.6
    • /
    • pp.262-269
    • /
    • 2021
  • This paper conducts an evaluation of the structural performance of the lap splice detail of SD700 headed bar experiment for developing an RC beam with different depths joint details. The experiment variable is lap splice length, yield strength, and end anchorage of main reinforcements. For all specimens, a headed bar was applied to the main reinforcement of the beam with low depth (B2), and the beam with high depth (B1) was applied to the main reinforcement with two splice methods: straight headed bar and 90° hooked-headed bar. The experimental results were that specimens of applying SD500 and SD600 had the results of flexural fracture at the lap splice location, which maximum load was similar. For specimens of appling SD500, the 90° hooked-headed bar of B1, suppressed horizontal cracks in the lap splice section compared to the straight headed bar. Specimens of applying an SD 700 headed bar had the results of brittle anchorage failure. In addition, maximum load was increased with the lap splice length increasing. For specimens of applying SD700 headed bar, test for test maximum load/theoretical load for test development length/design development length were estimated to be 1.30~1.48 for the ACI 318-19 equation, and 1.14~1.30 for the KDS-2021 equation. Thus, ACI 318-19 equation had conservatively greater safety factors as estimated development lengththened.

Application and conservation of 3D technology for the restoration of the original shape of military boots excavated in the DMZ (비무장지대 출토 군화의 형태 복원을 위한 3차원 디지털 기술의 적용 및 보존처리)

  • OH Seungjun;WI Koangchul
    • Korean Journal of Heritage: History & Science
    • /
    • v.56 no.2
    • /
    • pp.124-133
    • /
    • 2023
  • Preservation processing for two combat boots was executed through application of 3-dimensional digital technology and with use of preservation materials providing outstanding reversibility and stability. The aim of this was to establish a method to preserve the relics of fallen Korean War soldiers that had been excavated by the soldiers remains excavation corps of the Ministry of National Defense. It was possible to estimate the foot size of the soldiers who would have worn the combat boots via 3-dimensional digital scanning and modeling of the boots. In this process, the original form of the combat boots was restored through the use of 3D-printed structures. The original form was restored through a process of removing contaminants from the excavated relics and performing a conditioning treatment, and through use of an antique-color treatment after bonding and filling in the sections that had been ripped or deteriorated. Following the aforementioned preservation processes, it was possible to confirm that both of the combat boots had soles and top sections made of rubber, and portions of the top section and ankle section of the boots were made of synthetic rubber. As such, it was confirmed that these were similar to the Shoe Pac(M-1944, 12-inch) winter boots that had been manufactured for the purposes of waterproofing and/or protection against cold, and introduced in 1944. Such results confirmed that it is possible to discover the manufacturing techniques, materials, and uses of relics excavated through application of preservation processing, thereby illustrating the importance of the convergent research of scientific preservation processing and 3-dimensional digital technology.

Clinical Investigation about the Result of Surgically Treated Myasthenia Gravis (중증 근무력증의 수술적 치료결과에 대한 임상적 고찰)

  • 김대현;황은구;조규석;김범식;박주철
    • Journal of Chest Surgery
    • /
    • v.36 no.1
    • /
    • pp.15-20
    • /
    • 2003
  • Myasthenia gravis is a rare autoimmune disease involving acetylcholine receptor and its autoantibody on neuromuscular junction. The methods of treatment are medical treatment and surgical thymectomy. In this paper we analyzed the result of thymectomy and the factors affecting the postoperative symptom improvement. Material and method : This study obtained medical records of 37 patients who received the thymectomy for myasthenia gravis from March 1986 to December 1998. Result Out of 37 cases, 21 cases(57%) showed improvement, of which 8 cases (50%) in the group of thymoma(n=16), and 13 cases (62%) in the group of thymic hyperplasia(n=21) showed the improvement of symptoms. Postoperative complications were respiratory insufficiency due to aggravation of symptoms after operation, including tracheal intubation for ventilator support in 9 cases, pneumonia in 3 cases, pneumothorax in 2 cases and left vocal cord palsy in 1 case. There was one postoperative mortality. The relation between postoperative improvement and sex(P=0.3222), age(P=0.7642), thymic pathologic variants,(P=0.4335) and classification of thymoma(P=0.20) showed no statistically significant correlation. However, the lower grade of preoperative symptoms can predict the lower grade of postoperative symptoms significantly(P=0.0032). Follow up study to 36 postoperative survivors was performed in October 2002 based on the out-patient records and call with patients. Out of 36 cases, 33 cases(91.7%) could be investigated and 3 cases could not. Mean follow up period was 83.2 months. Out of 33 cases, 25 cases(75.8%) showed symptomatic improvement, of which 8 cases(53.3%) in the group of thymoma(n=15) and 17 cases(94.4%) in the group of thymic hyperplasia(n=18) showed the improvement of$\boxUl$ symptoms. Conclusion : In myasthenia gravis, thymectomy showed the good improvement, and more important factor affecting the improvement of symptoms was the grdae of preoperative symptoms. Also midterm and long term follow up results showed good symptomatic improvement.